首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Results of a complete survey of the more than 2-million-member Pharmacopeia compound collection in a 1536-well microvolume screening assay format are reported. A complete technology platform, enabling the performance of ultra-high throughput screening in a miniaturized 1536-well assay format, has been assembled and utilized. The platform consists of tools for performing microvolume assays, including assay plates, liquid handlers, optical imagers, and data management software. A fluorogenic screening assay for inhibition of a protease enzyme target was designed and developed using this platform. The assay was used to perform a survey screen of the Pharmacopeia compound collection for active inhibitors of the target enzyme. The results from the survey demonstrate the successful implementation of the ultra-high throughout platform for routine screening purposes. Performance of the assay in the miniaturized format is equivalent to that of a standard 96-well assay, showing the same dependence on kinetic parameters and ability to measure enzyme inhibition. The survey screen identified an active class of compounds within the Pharmacopeia compound collection. These results were confirmed using a standard 96-well assay.  相似文献   

2.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

3.
CYP2C9 is a genetically polymorphic human cytochrome P450 isozyme involved in the oxidative metabolism of many drugs, including nonsteroidal anti-inflammatory compounds. Individuals genotyped heterozygous or homozygous for CYP2C9 allelic variants have demonstrated altered metabolism of some drugs primarily metabolized by CYP2C9. The ability to expand screening of CYP2C9 allelic variants to a larger set of drugs and pharmaceutical agents would contribute to a better understanding of the significance of CYP2C9 polymorphisms in the population and to predictions of possible outcomes. The authors report the development of an in vitro fluorescence-based assay employing recombinant CYP2C9 variants (CYP2C9*1, CYP2C9*2, and CYP2C9*3) and fluorogenic Vivid(R) CYP2C9 substrates to explore the effects of CYP2C9 polymorphisms on drug metabolism, using drugs primarily metabolized by CYP2C9. Several chemically diverse fluorogenic substrates (Vivid(R) CYP2C9 blue, green, and red substrates) were used as prototypic probes to obtain in vitro CYP2C9 metabolic rates and kinetic parameters, such as apparent K(m), V(max), and V(max)/K(m) ratios for each allelic variant. In addition, a diverse panel of drugs was screened as assay modifiers with CYP2C9*1, CYP2C9*2, CYP2C9*3, and the fluorogenic Vivid(R) CYP2C9 substrates. The inhibitory potential of this large group of chemically diverse drugs and compounds has been assessed on the basis of their ability to compete with Vivid(R) CYP2C9 substrates in fluorescent reporter assays, thus providing a sensitive and quick assessment of polymorphism-dependent changes in CYP2C9 metabolism.  相似文献   

4.
Mechanism-based inactivators such as bergamottin are useful chemical tools for identifying the functions of specific active-site amino acid residues in the reactions catalyzed by cytochromes P450 (CYPs or P450s), which are responsible for the metabolism of a wide variety of drugs and endogenous substrates. In clinical settings, mechanism-based inactivation of P450s involved in xenobiotic metabolism has the potential to lead to adverse drug-drug interactions, and assays to identify and characterize drug candidates as P450 inactivators are important in drug discovery and development. Here we present a quantitative high-throughput protocol for investigating cytochrome P450 mechanism-based inactivators; we use the example of CYP2B6 and bergamottin to illustrate the finer points of this protocol. This protocol details the adaptation of a 7-ethoxytrifluoromethyl coumarin O-deethylation fluorescence activity assay to a 96-well microtiter plate format and uses a plate reader to detect the fluorescence of the product. Compared with previous methods, this protocol requires less P450 and takes significantly less time while greatly increasing throughput. The protocol as written takes ~2 h to complete. The principles and procedures outlined in this protocol can be easily adapted to other inactivators, P450 isoforms, substrates and plate readers.  相似文献   

5.
Powerful directed evolution methods have been developed for tailoring proteins to our needs in industrial applications. Here, the authors report a medium-throughput assay system designed for screening mutant libraries of oxygenases capable of inserting a hydroxyl group into a C-H bond of aromatic or O-heterocyclic compounds and for exploring the substrate profile of oxygenases. The assay system is based on 4-aminoantipyrine (4-AAP), a colorimetric phenol detection reagent. By using 2 detection wavelengths (509 nm and 600 nm), the authors achieved a linear response from 50 to 800 microM phenol and standard deviations below 11% in 96-well plate assays. The monooxygenase P450 BM-3 and its F87A mutant were used as a model system for medium-throughput assay development, identification of novel substrates (e.g., phenoxytoluene, phenylallyether, and coumarone), and discovery of P450 BM-3 F87A mutants with 8-fold improvement in 3-phenoxytoluene hydroxylation activity. This activity increase was achieved by screening a saturation mutagenesis library of amino acid position Y51 using the 4-AAP protocol in the 96-well format.  相似文献   

6.
7.
8.
9.
High-throughput screening in the 1536-well format has been largely restricted to solution-based and cell-based screens. In this article, we show the feasibility of a completely automated, robust scintillation proximity assay in the 1536-well format that is suitable to identify inhibitors for a serine/threonine kinase from a compound library. The introduction of [(33)P]phosphate into a biotinylated peptide substrate mirrors the activity of the kinase. The peptide is immobilized on streptavidin-coated LEADseeker imaging beads and [(33)P]phosphate incorporation is detected with the LEADseeker imaging system of Amersham Pharmacia Biotech. To improve the liquid handling procedures for imaging bead suspensions in the low microliter range, we developed a novel trough with an integrated stirring function. A comparison of the 1536-well assay to a 384-well assay revealed a comparable assay quality with Z' factors of about 0.7 for the 384-well format and 0.6 for the 1536-well format. In an automated screen of a random compound collection, 94.4% of the inhibitory compounds could be identified with both assay formats. Dose-response curves were performed for a selection of identified kinase inhibitors and revealed similar IC(50) values for both assay formats.  相似文献   

10.
DNA helicases are responsible for the unwinding of double-stranded DNA, facilitated by the binding and hydrolysis of 5'-nucleoside triphosphates. These enzymes represent an important class of targets for the development of novel anti-infective agents particularly because opportunity exists for synergy with existing therapies targeted at other enzymes involved in DNA replication. Unwinding reactions are conventionally monitored by low throughput, gel-based radiochemical assays; to overcome the limitations of low throughput to achieve comprehensive characterization of adenosine triphosphate (ATP)-dependent unwinding by viral and bacterial helicases and the screening for unwinding inhibitors, we have developed and validated homogeneous time-resolved fluorescence energy transfer (TRET) assays. Rapid characterization and screening of DNA helicase has been performed in 96- and 384-well plate densities, and the ability to assay in 1536-well format also demonstrated. We have successfully validated and are running full high throughput runs using 384-well TRET helicase assays, culminating in the identification of a range of chemically diverse inhibitors of viral and bacterial helicases. For screening in mixtures, we used a combination of quench correction routines and confirmatory scintillation proximity (SP) assays to eliminate false-positives due to the relatively high levels of compound quenching (unlike other Ln(3+)-based assays). This strategy was successful yet emphasised the need for further improvements in helicase assays.  相似文献   

11.
Novel methods for biocatalyst screening   总被引:5,自引:0,他引:5  
There have been a number of recent advances in catalysis assays applicable for screening biocatalyst libraries in high-throughput format. These include instrumental assays such as high-performance liquid chromatography, mass spectrometry, capillary electrophoresis and IR-thermography, reagent-based assays producing spectroscopic signals (UV/VIS or fluorescence) in response to reaction progress, and assays based on fluorogenic or chromogenic substrates. These fluorogenic substrates enable the assaying of a variety of enzymes in enantioselective and stereoselective manner, including alcohol dehydrogenases, aldolases, lipases, amidases, epoxide hydrolases and phosphatases.  相似文献   

12.
A simple, optical density-based assay for inhibitors of the mevalonate-dependent pathway for isoprenoid biosynthesis was developed. The assay uses pathway-sensitized Staphylococcus aureus strains and is fully compatible with high-density screening in a 1536-well format. S. aureus strains were constructed in which genes required for mevalonate-dependent isopentenyl pyrophosphate (IPP) synthesis were regulated by an isopropyl-β-D-thiogalactopyranoside (IPTG)-inducible promoter. Inhibitors of the target enzymes displayed greater antibacterial potency in media containing low concentrations of IPTG, and therefore less induction of mevalonate pathway genes, than in media with high IPTG conditions. This differential growth phenotype was exploited to bias the cell-based screening hits toward specific inhibitors of mevalonate-dependent IPP biosynthesis. Screens were run against strains engineered for regulation of the enzymes HMG-CoA synthase (MvaS) and mevalonate kinase (mvaK1), mevalonate diphosphate decarboxylase (mvaD), and phosphomevalonate kinase (mvaK2). The latter three enzymes are regulated as an operon. These assays resulted in the discovery of potent antibacterial hits that were progressed to an active hit-to-lead program. The example presented here demonstrates that a cell sensitization strategy can be successfully applied to a 1.3-million compound high-throughput screen in a high-density 1536-well format.  相似文献   

13.
Miniaturization of high-throughput screening (HTS) assays has several obvious advantages, including increased throughput and lower cost by reduction in reagent consumption. Although absorbance assays are widely used in research laboratories, their application for HTS in a low-volume format has been met with mixed success because they are difficult to miniaturize. Challenges for the miniaturization of absorbance assays include low signal due to short path lengths and meniscus distortions in small well sizes. Here we describe a method to miniaturize absorbance assays to standard, white, low-volume 384-well and 1536-well microplates using a fluorometric plate reader for detection. The premise of this absorbance assay is based on the fluorescent properties of white microplates and the ability of a colored product to quench the fluorescence signal from the plate by absorbing either the excitation light or the emission light. This method was applied to the detection of inorganic phosphate using Quinaldine red and Malachite green dyes and to the monitoring of alkaline phosphatase hydrolysis of p-nitrophenyl phosphate. These assays can be carried out in low volumes, give robust screening statistics, and can be accomplished with a simple, inexpensive fluorometric plate reader.  相似文献   

14.
p56(lck) is a lymphocyte-specific tyrosine kinase that plays an important role in both T-cell maturation and activation. We have developed a homogeneous assay in which p56(lck) catalyzes the transfer of the gamma-phosphate group from [gamma-(33)P]ATP to a biotinylated peptide substrate. The labeled peptide is then captured on a streptavidin-coated scintillation proximity assay (SPA) bead or imaging proximity bead. The SPA is counted in a microplate scintillation counter and the imaging proximity assay is counted in a charge-coupled device-based imaging system called LEADseekertrade mark, recently launched as a homogeneous imaging system by Amersham Pharmacia Biotech. We show, via time-dependence assays and inhibitor studies, that this assay can be performed in 1536-well microplate format using imaging proximity as the method of detection. The results compare favorably with the same assay performed in 384-well microplate format using both SPA and imaging proximity as the detection methods. From this study, we conclude that a kinase assay can be performed in 384- and 1536-well format using imaging as the detection method, with significant time savings over standard scintillation counting. In addition, we show cost saving advantages of 1536- over 384-well format in terms of reagent usage, higher throughput, and waste disposal.  相似文献   

15.
Enantiomerically pure 1-(6-methoxynaphth-2-yl) and 1-(6-(dimethylamino)naphth-2-yl) carbinols are fluorogenic substrates for aldo/keto reductase (KRED) enzymes, which allow the highly sensitive and reliable determination of activity and kinetic constants of known and unknown enzymes, as well as an immediate enantioselectivity typing. Because of its simplicity in microtiter plate format, the assay qualifies for the discovery of novel KREDs of yet unknown specificity among this vast enzyme superfamily. The suitability of this approach for enzyme typing is illustrated by an exemplary screening of a large collection of short-chain dehydrogenase/reductase (SDR) enzymes arrayed from a metagenomic approach. We believe that this assay format should match well the pharmaceutical industry’s demand for acetophenone-type substrates and the continuing interest in new enzymes with broad substrate promiscuity for the synthesis of chiral, non-racemic carbinols.  相似文献   

16.
Dipeptidyl peptidase 1 (DPP1) (EC 3.4.14.1; also known as cathepsin C, cathepsin J, dipeptidyl aminopeptidase, and dipeptidyl aminotransferase) is a lysosomal cysteinyl protease of the papain family involved in the intracellular degradation of proteins. Isolated enzyme assays for DPP1 activity using a variety of synthetic substrates such as dipeptide or peptide linked to amino-methyl-coumarin (AMC) or other fluorophores are well established. There is, however, no report of a simple whole-cell-based assay for measuring lysosomal DPP1 activity other than the use of flow cytometry (fluorescence-activated cell sorting) or the use of invasive activity-based probes or the production of physiological products such as neutrophil elastase. The authors investigated a number of DPP1 fluorogenic substrates that have the potential to access the lysosome and enable the measurement of DPP1 enzyme activity in situ. They describe the development and evaluation of a simple noninvasive fluorescence assay for measuring DPP1 activity in fresh or cryopreserved human THP-1 cells using the substrate H-Gly-Phe-AFC (amino-fluoro-coumarin). This cell-based fluorescence assay can be performed in a 96-well plate format and is ideally suited for determining the cell potency of potential DPP1 enzyme inhibitors.  相似文献   

17.
Components within synthetic chemical and natural product extract libraries often interfere with fluorescence-based assays. Fluorescence interference can result when the intrinsic spectral properties of colored compounds overlap with the fluorescent probes. Typically, fluorescence-based protease assays use peptide amidomethylcoumarin derivatives as substrates. However, because many organic compounds absorb in the ultraviolet region, they can interfere with coumarin-based fluorescence assays. Red-shifted fluorescent dyes such as peptidyl rhodamine derivatives are useful because there is generally less interference from organic compounds outside the ultraviolet wavelengths. In this report, rhodamine-based fluorogenic substrates, such as bis-(Leu)(2)-Rhod110 and bis-(Ala-Pro)-Rhod110, were developed for leucine aminopeptidase and dipeptidyl aminopeptidase. Novel, tandem rhodamine substrates such as Ala-Pro-Rhod110-Leu were designed with 2 protease cleavage sites and used to assay 2 proteases in a multiplex format. General endpoint high-throughput screening (HTS) assays were also developed for leucine aminopeptidase, dipeptidyl aminopeptidase, and trypsin that incorporated both amidomethylcoumarin and rhodamine-based fluorogenic substrates into a single screening format. These dual-substrate assays allowed for the successful screening of the LOPAC trade mark collection and natural product extracts despite high levels of fluorescence interference.  相似文献   

18.
Kinases are important drug discovery targets for a wide variety of therapeutic indications; consequently, the measurement of kinase activity remains a common high-throughput screening (HTS) application. Recently, enzyme-coupled luciferase-kinase (LK) format assays have been introduced. This format measures luminescence resulting from metabolism of adenosine triphosphate (ATP) via a luciferin/luciferase-coupled reaction. In the research presented here, 1536-well format time-resolved fluorescence resonance energy transfer (TR-FRET) and LK assays were created to identify novel Rho-associated kinase II (ROCK-II) inhibitors. HTS campaigns for both assays were conducted in this miniaturized format. It was found that both assays were able to consistently reproduce the expected pharmacology of inhibitors known to be specific to ROCK-II (fasudil IC50: 283 +/- 27 nM and 336 +/- 54 nM for TR-FRET and LK assays, respectively; Y-27632 IC50: 133 +/- 7.8 nM and 150 +/- 22 nM for TR-FRET and LK assays, respectively). In addition, both assays proved robust for HTS efforts, demonstrating excellent plate Z' values during the HTS campaign (0.84 +/- 0.03; 0.72 +/- 0.05 for LK and TR-FRET campaigns, respectively). Both formats identified scaffolds of known and novel ROCK-II inhibitors with similar sensitivity. A comparison of the performance of these 2 assay formats in an HTS campaign was enabled by the existence of a subset of 25,000 compounds found in both our institutional and the Molecular Library Screening Center Network screening files. Analysis of the HTS campaign results based on this subset of common compounds showed that both formats had comparable total hit rates, hit distributions, amount of hit clusters, and format-specific artifact. It can be concluded that both assay formats are suitable for the discovery of ROCK-II inhibitors, and the choice of assay format depends on reagents and/or screening technology available.  相似文献   

19.
In response to the need for inexpensive high throughput assays for anti-cancer drug screening, a 1536-well microtiter plate based assay utilizing the Alamar Blue fluorescent dye as a measure of cellular growth was validated in 10 μL assay volume. Its robustness was assessed in a screen against a library of 2000 known bioactives; with an overall Z′ value of 0.89 for assay robustness, several known cytotoxic agents were identified including and not limited to anthracyclines, cardiac glycosides, gamboges, and quinones. To further test the sensitivity of the assay, IC50 determinations were performed in both 384-well and 1536-well formats and the obtained results show a very good correlation between the two density formats. These findings demonstrate that this newly developed assay is simple to set up, robust, highly sensitive and inexpensive. It could potentially provide a rapid way to screen established and primary tumor cell lines against large chemical libraries.  相似文献   

20.
In response to the need for inexpensive high throughput assays for anti-cancer drug screening, a 1536-well microtiter plate based assay utilizing the Alamar Blue fluorescent dye as a measure of cellular growth was validated in 10 microL assay volume. Its robustness was assessed in a screen against a library of 2000 known bioactives; with an overall Z' value of 0.89 for assay robustness, several known cytotoxic agents were identified including and not limited to anthracyclines, cardiac glycosides, gamboges, and quinones. To further test the sensitivity of the assay, IC50 determinations were performed in both 384-well and 1536-well formats and the obtained results show a very good correlation between the two density formats. These findings demonstrate that this newly developed assay is simple to set up, robust, highly sensitive and inexpensive. It could potentially provide a rapid way to screen established and primary tumor cell lines against large chemical libraries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号