首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and selective reversed-phase liquid chromatographic assay for itraconazole and hydroxyitraconazole in human plasma has been developed and validated. Itraconazole and hydroxyitraconazole were extracted from the matrix using solid-phase extraction on a strong cation-exchange sorbent. All compounds were detected using fluorescence at 265 and 363 nm for excitation and emission, respectively. The assay has been validated over the range 10-1,000 ng/ml for both compounds, 10 ng/ml being the lower limit of quantification. Accuracies ranged from 104 to 113% for itraconazole and from 91 to 103% for hydroxyitraconazole. The intra-assay precisions were all below 9% for itraconazole and below 8% for hydroxyitraconazole. The selectivity has been evaluated with respect to all registered anti-human immunodeficiency virus (HIV) drugs and other potential co-medications and a few of their metabolites, commonly used by HIV-infected individuals. Both itraconazole and hydroxyitraconazole were stable under relevant conditions for HIV-inactivation and storage of samples. The applicability of the assay was demonstrated for samples collected from a treated HIV-infected patient.  相似文献   

2.
A highly sensitive and specific LC-MS/MS method has been developed for simultaneous estimation of itraconazole (ITZ) and hydroxyitraconazole (OH-ITZ) with 500 microL of human plasma using fluconazole as an internal standard (IS). The API-4000 LC-MS/MS was operated under the multiple reaction-monitoring mode (MRM) using the electrospray ionization technique. Solid phase extraction process was used to extract ITZ, OH-ITZ and IS from human plasma. The total run time was 3.0 min and the elution of ITZ, OH-ITZ and IS occurred at 2.08 min, 1.85 min and 1.29 min, respectively; this was achieved with a mobile phase consisting of 0.2% (v/v) ammonia solution:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a HyPurity C(18) (50 mm x 4.6 mm, 5 microm) column. The developed method was validated in human plasma with a lower limit of quantitation of 0.50 ng/mL for both ITZ and OH-ITZ. A linear response function was established for the range of concentrations 0.5-263 ng/mL (r>0.998) for both ITZ and OH-ITZ. The intra- and inter-day precision values for ITZ and OH-ITZ met the acceptance as per FDA guidelines. ITZ and OH-ITZ were stable in the battery of stability studies, viz., bench-top, auto-sampler, dry extract and freeze/thaw cycles. The developed assay method was applied to an oral bioequivalence study in humans.  相似文献   

3.
4.
A simple, sensitive and reliable method was developed to determine simultaneously the concentrations of thienorphine and its metabolite thienorphine glucuronide conjugate in rat plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The metabolite was identified by MS: thienorphine glucuronide conjugate. Sample preparation involved protein precipitation with methanol. Analytes were separated on Finnigan BetaBasic-18 column (150 mm x 2.1mm i.d., 5 microm) using methanol: water: formic acid (56:44:0.1, v/v/v) as mobile phase at a flow rate of 0.2 ml/min. The method had a linear calibration curve over the concentration range of 0.1-50 ng/ml for thienorphine and 2-1000 ng/ml for thienorphine glucuronide conjugate, respectively. LOQ of thienorphine and thienorphine glucuronide conjugate was 0.1 and 2 ng/ml, respectively. The intra- and inter-batch precisions were less than 12% and their recoveries were greater than 80%. Pharmacokinetic data of thienorphine and its metabolite thienorphine glucuronide conjugate obtained with this method following a single oral dose of 3mg/kg thienorphine to rats were also reported for the first time.  相似文献   

5.
We have developed a sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantification of midazolam (MDZ) and its major metabolite, 1'-hydroxymidazolam (1'-OHM) in a small volume (200 microl) of human plasma. Midazolam, 1'-OHM and 1'-chlordiazepoxide (internal standard) were extracted from alkalinised (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with 1-chlorobutane. The chromatographic separation was performed on a reversed-phase HyPURITY Elite C18 (5 microm particle size; 100 mm x 2.1mm i.d.) analytical column using an acidic (pH 2.8) mobile phase (water-acetonitrile; 75:25% (v/v) containing formic acid (0.1%, v/v)) delivered at a flow-rate of 200 microl/min. The mass spectrometer was operated in the positive ion mode at the protonated-molecular ions [M+l]+ of parent drug and metabolite. Calibration curves in spiked plasma were linear (r2 > or = 0.99) from 15 to 600 ng/ml (MDZ) and 5-200 ng/ml (1'-OHM). The limits of detection and quantification were 2 and 5 ng/ml, respectively, for both MDZ and 1'-OHM. The mean relative recoveries at 40 and 600 ng/ml (MDZ) were 79.4+/-3.1% (n = 6) and 84.2+/-4.7% (n = 8), respectively; for 1'-OHM at 30 and 200 ng/ml the values were 89.9+/-7.2% (n = 6) and 86.9+/-5.6% (n = 8), respectively. The intra-assay and inter-assay coefficients of variation (CVs) for MDZ were less than 8%, and for 1'-OHM were less than 13%. There was no interference from other commonly used antimalarials, antipyretic drugs and antibiotics. The method was successfully applied to a pharmacokinetic study of MDZ and 1'-OHM in children with severe malaria and convulsions following administration of MDZ either intravenously (i.v.) or intramuscularly (i.m.).  相似文献   

6.
This paper describes sensitive and reliable determination of midazolam (MDZ) and its major metabolite 1'-hydroxymidazolam (1-OHMDZ) in human plasma by liquid chromatography-mass spectrometry (LC-MS) with a sonic spray ionization (SSI) interface. MDZ, 1-OHMDZ and diazepam as an internal standard were extracted from 1ml of alkalinized plasma using n-hexane-chloroform (70:30, v/v). The extract was injected into an analytical column (YMC-Pak Pro C(18), 50mmx2.0mmi.d.). The mobile phase for separation consisted of 10mM ammonium acetate and methanol (50:50, v/v) and was delivered at a flow-rate of 0.2ml/min. The drift voltage was 100V. The sampling aperture was heated at 120 degrees C and the shield temperature was 260 degrees C. The total time for chromatographic separation was less than 16min. The validated concentration ranges of this method were 0.25-50ng/ml for both MDZ and 1-OHMDZ. Mean recoveries were 93.6% for MDZ and 86.6% for 1-OHMDZ. Intra- and inter-day coefficient variations were less than 6.5 and 5.5% for MDZ, and 6.1 and 5.7% for 1-OHMDZ at 0.3, 4, 20 and 40ng/ml. The limits of quantification were 0.25ng/ml for both MDZ and 1-OHMDZ. This method was sensitive and reliable enough for pharmacokinetic studies on healthy volunteers, and was applied for the measurement of CYP3A activity in humans after an intravenous (1mg) and a single-oral administration (2mg) of subtherapeutic MDZ dose.  相似文献   

7.
A stereoselective high-performance liquid chromatographic method for the determination of the enantiomers of ketamine and its active metabolite, norketamine, in human plasma is described. The compounds were extracted from plasma by liquid–liquid extraction three times in a combination of cyclohexane with 2.5 M NaOH, 1 mM HCl and 1 M carbonate buffer. Stereoselective separation was achieved on a Chiralcel OD column with a mobile phase of n-hexane–2-propanol (98:2, v/v). The detection wavelength was 215 nm. The lower limits of the determination of the method were 5 ng/ml for ketamine and 10 ng/ml for norketamine. The intra- and inter-day coefficients of variation ranged from 2.9 to 9.8% and from 3.4 to 10.7% for all compounds, respectively. The method was sensitive and sufficiently reproducible for stereoselective monitoring of ketamine and norketamine in human plasma during pharmacokinetic studies after the administration of ketamine for analgesia.  相似文献   

8.
A high-performance liquid chromatographic method is described for the determination of citalopram [1-(3-(dimethylaminopropyl)-1-(4-fluorophenyl)-5-phthalancarbonitrile] and its two main metabolites (the methylamino and amino derivatives). The compounds were extracted from alkaline plasma with diethyl ether. The combined ether layers were evaporated after addition of 50 μl of 0.1 N HCl. The residual extracts were purified with diethyl ether and 20 μl were injected into a Spherisorb ODS 5-μm column with acetonitrile–0.6% phosphate buffer pH 3 (55:45, v/v) as the mobile phase. Using a fluorescence detector the detection limits are 1 ng/ml of plasma for citalopram and the methylamino metabolite and 0.5 ng/ml for the amino metabolite.  相似文献   

9.
A novel, highly sensitive method was developed for simultaneous determination of tramadol and its main active metabolite O-demethyltramadol (ODMT) in rat plasma. The method involves a single-step extraction procedure and a specific determination by high-performance liquid chromatography with electrochemical detection, using an ethoxy analogue of tramadol (L-233) as internal standard. The dual-electrode detector was operated in the oxidation-screening mode. Absolute recoveries of tramadol and ODMT were about 80%. Calibration curves were linear over a concentration range of 10–1000 ng/ml for ODMT and 10–10 000 ng/ml for tramadol with intra- and inter-day coefficients of variation not exceeding 10% and 15%, respectively. The limit of quantification for tramadol and ODMT was lower than 15 ng/ml and 10 ng/ml using 100 μl of plasma, respectively. The described method allows an adequate characterization of the plasma vs. time profiles for both compounds.  相似文献   

10.
We describe a liquid chromatography-electrospray ionisation tandem mass spectrometry method for the qualitative and quantitative determination of the secoiridoid oleuropein and its bioactive metabolite hydroxytyrosol in rat plasma and urine. Samples were prepared by liquid-liquid extraction using ethyl acetate with a recovery for both compounds of about 100% in plasma and about 60% in urine. The chromatographic separation was performed with a RP-ODS column using a water-acetonitrile linear gradient. The calibration curve was linear for both biophenols over the range 2.5-1000 ng/ml (LOD 1.25 ng/ml) for plasma and 5-1000 ng/ml (LOD 2.5 ng/ml) for urine. Plasma concentrations of oleuropein and hydroxytyrosol were measured after oral administration of a single dose (100 mg/kg) of oleuropein. Analysis of treated rat plasma showed the presence of unmodified oleuropein, reaching a peak value of 200 ng/ml within 2 h, with a small amount of hydroxytyrosol, whereas in urine, both compounds were mainly found as glucuronides.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method using a mobile phase of acetonitrile-methanol-trifluoroacetic acid-water (16.1:7.2:0.1:76.6, v/v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher RP-18 column with UV (254 nm) detection has been developed for the separation of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma. No interferences due to endogenous compounds or common antimalarial drugs were noticed. The limit of detection for sulfadoxine and N-acetyl sulfadoxine was 0.01 microg ml(-1) with a signal-to-noise ratio of 5:1 while the limit of quantification was 2.5 microg ml(-1). Intra-day mean relative standard deviations (RSD's) for sulfadoxine and N-acetyl sulfadoxine were 2.6 and 2.8%, respectively, while mean inter-day RSD's for sulfadoxine and N-acetyl sulfadoxine were 2.4 and 2.8%, respectively. Extraction recoveries averaged 90.6% for sulfadoxine and 86.9% for N-acetyl sulfadoxine. The method was applied for the assay of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma from Plasmodium falciparum malaria patients. Mean plasma sulfadoxine concentrations on day 2 (51 h) from samples collected from sensitive and resistant P. falciparum patients treated with three tablets of Fansidar were 62.8 and 60.5 microg ml(-1), respectively. Mean ratio of N-acetyl sulfadoxine to sulfadoxine was 9.1% for responders and 13.9% for non-responders which revealed that higher amounts of the metabolite N-acetyl sulfadoxine were present in non-responders. The method described should find an application in the therapeutic monitoring of malaria patients.  相似文献   

12.
The combination of two sensitive, selective and reproducible reversed phase liquid chromatographic (RP-HPLC) methods was developed for the determination of artesunate (AS), its active metabolite dihydroartemisinin (DHA) and mefloquine (MQ) in human plasma. Solid phase extraction (SPE) of the plasma samples was carried out on Supelclean LC-18 extraction cartridges. Chromatographic separation of AS, DHA and the internal standard, artemisinin (QHS) was obtained on a Hypersil C4 column with mobile phase consisting of acetonitrile-0.05 M acetic acid adjusted to pH 5.2 with 1.0M NaOH (42:58, v/v) at the flow rate of 1.50 ml/min. The analytes were detected using an electrochemical detector operating in the reductive mode. Chromatography of MQ and the internal standard, chlorpromazine hydrochloride (CPM) was carried out on an Inertsil C8-3 column using methanol-acetonitrile-0.05 M potassium dihydrogen phosphate adjusted to pH 3.9 with 0.5% orthophosphoric acid (50:8:42, v/v/v) at a flow rate of 1.00 ml/min with ultraviolet detection at 284 nm. The mean recoveries of AS and DHA over a concentration range of 30-750 ng/0.5 ml plasma and MQ over a concentration of 75-1500 ng/0.5 ml plasma were above 80% and the accuracy ranged from 91.1 to 103.5%. The within-day coefficients of variation were 1.0-1.4% for AS, 0.4-3.4% for DHA and 0.7-1.5% for MQ. The day-to-day coefficients of variation were 1.3-7.6%, 1.8-7.8% and 2.0-3.4%, respectively. Both the lower limit of quantifications for AS and DHA were at 10 ng/0.5 ml and the lower limit of quantification for MQ was at 25 ng/0.5 ml. The limit of detections were 4 ng/0.5 ml for AS and DHA and 15 ng/0.5 ml for MQ. The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

13.
A rapid and specific HPLC method has been developed and validated for simultaneous determination of clobazam, the anticonvulsant agent, and its major metabolite in human plasma. The sample preparation was a liquid-liquid extraction with tuloene yielding almost near 100% recoveries of two compounds. Chromatographic separation was achieved with a Chromolith Performance RP-18e 100 mm x 4.6mm column, using a mixture of a phosphate buffer (pH 3.5; 10mM)-acetonitrile (70:30, v/v), in isocratic mode at 2 ml/min at a detection wave-length of 228 nm. The calibration curves were linear (r(2)>0.998) in the concentration range of 5-450 ng ml(-1). The lower limit of quantification was 5 ng ml(-1) for two compounds studied. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 0.89-9.1% and 2.1-10.1% R.S.D., respectively. The developed procedure was applied to assess the pharmacokinetics of clobazam and its major metabolite following administration of a single 10mg oral dose of clobazam to healthy volunteers.  相似文献   

14.
A rapid and sensitive high-performance liquid chromatographic method for the determination of the novel ergoline derivatives sergolexole (compound I), its acid metabolite (compound II) and cis-n-(2-hydroxycyclopentyl)-6-methyl-1-(1-methylethyl) ergoline-8-carboxamide (LY215840, compound III) in human plasma is reported. The compounds were extracted from plasma by automated solid-phase extraction and analysed on a reversed-phase C8 column with fluorescence detection. The limit of quantification for all compounds was 10 ng/ml and the response was linear over the range 10–1000 ng/ml. Validation studies showed the method to be both repeatable and reproducible with no interference from human plasma. The method has been used to support pharmacokinetic studies and has proved to be robust and effective.  相似文献   

15.
A sensitive and specific method for the determination of the active primary amine metabolite of sibutramine, N-di-desmethylsibutramine (BTS 54,505), in human plasma was developed, based on high-performance liquid chromatography (HPLC)-electrospray ionization tandem mass spectrometry (MS-MS). The samples were extracted from plasma with methyl tert.-butyl ether, followed by separation and evaporation after addition of the internal standard, propranolol, and basification with sodium hydroxide. The residue was reconstituted in mobile phase and injected into the HPLC-MS-MS system. Chromatography was performed on an ODS MS column with a mobile phase consisting of acetonitrile (containing 0.1% trifluoroacetic acid, v/v)-0.1% trifluoroacetic acid (55:45, v/v) at a flow-rate of 0.3 ml/min. Multiple reaction monitoring using precursor-->product ion combinations at m/z 252.00-->125.00 and 260.00-->115.70 was applied to determine BTS 54,505 and propranolol, respectively. Linearity was confirmed in the concentration range 0.328-32.8 ng/ml in human plasma and the imprecision of this assay was less than 19.90% over the entire concentration range. The method is sufficiently sensitive and repeatable to be used in pharmacokinetic studies.  相似文献   

16.
Quantitative analysis of therapeutic compounds and their metabolites in biological matrix (such as plasma, serum or urine) nowadays requires sensitive and selective methods to allow the determination of concentrations in the ng/ml range. A new on-line LC–MS–MS method using atmospheric pressure chemical ionisation (APCI) as interface for the simultaneous determination of nifedipine (NIF) and its metabolite in human plasma, dehydronifedipine (DNIF) has been developed. The compounds were extracted from plasma using solid-phase extraction (SPE) on disposable extraction cartridges (DECs). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with phenyl modified silica was first conditioned with methanol and water. The washing step was performed with water. Finally, the analytes were successively eluted with methanol and water. The liquid chromatographic (LC) separation of NIF and DNIF was achieved on a RP-18 stationary phase (4 μm). The mobile phase consisted of methanol–50 mM ammonium acetate solution (50:50, v/v). The LC was then coupled to tandem mass spectrometry with an APCI interface in the positive ion mode.

The method developed was validated. The absolute recoveries evaluated over the whole concentration range were 95±2% and 95±4% for NIF and DNIF, respectively. The method was found to be linear in the 0.5–100 ng/ml concentration range for the two analytes (r2=0.999 for both NIF and DNIF). The mean R.S.D. values for repeatability and intermediate precision were 2.9 and 3.0% for NIF and 2.2–4.7% for the metabolite.The method developed was successfully used to investigate the plasma concentration of NIF and DNIF in the pharmacokinetic studies.  相似文献   


17.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

18.
A rapid, selective and sensitive HPLC–tandem mass spectrometry method was developed and validated for simultaneous determination of flupirtine and its active metabolite D-13223 in human plasma. The analytes and internal standard diphenhydramine were extracted from plasma samples by liquid–liquid extraction, and chromatographed on a C18 column. The mobile phase consisted of acetonitrile–water–formic acid (60:40:1, v/v/v), at a flow rate of 0.5 ml/min. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via atmospheric pressure chemical ionization (APCI). The method has a limit of quantitation of 10 ng/ml for flupirtine and 2 ng/ml for D-13223, using 0.5-ml plasma sample. The linear calibration curves were obtained in the concentration range of 10.0–1500.0 ng/ml for flupirtine and 2.0–300.0 ng/ml for D-13223. The intra- and inter-run precision (RSD), calculated from quality control (QC) samples was less than 7.2% for flupirtine and D-13223. The accuracy as determined from QC samples was less than 5% for the analytes. The overall extraction recoveries of flupirtine and D-13223 were determined to be about 66% and 78% on average, respectively. The method was applied for the evaluation of the pharmacokinetics of flupirtine and active metabolite D-13223 in volunteers following peroral administration.  相似文献   

19.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

20.
A simple and sensitive column-switching high-performance liquid chromatographic (HPLC) method with fluorescence detection is described for the quantification of perospirone, a serotonin and dopamine antagonist, and its metabolite ID-15036 in human plasma. The test compounds were extracted from 2 ml of plasma using chloroform-hexane (30:70, v/v) and the extract was injected into a column I (TSK-PW precolumn, 10 micro m, 35 x 4.6 mm I.D.) for clean-up and column II (C(18) STR ODS-II analytical column, 5 micro m, 150 x 4.6 mm I.D.) for separation. The peak was detected using a fluorescence detector set at Ex 315 nm and Em 405 nm, and the total time for a chromatographic separation was approximately 30 min. The method was validated for the concentration range from 0.1 to 100 ng/ml. Mean recoveries were 97% for perospirone and 96% for ID-15036. Intra- and inter-day relative standard deviations were less than 2.8 and 5.3% for perospirone and 2.4 and 4.4% for ID-15036, respectively, at the concentration range from 0.3 to 30 ng/ml. This method shows good specificity with respect to commonly prescribed psychotropic drugs, and it could be successfully applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号