首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The co-immobilization of glucose oxidase (GOD) and hexokinase/glucose-6-phosphate dehydrogenase (HEX) in the silica hybrid sol-gel film for development of amperometric biosensors was investigated. The silica hybrid film fabricated by hydrolysis of the mixture of tetraethyl orthosilicate and 3-(trimethoxysiyl)propyl methacrylate possessed a three-dimension vesicle structure and good uniformity and conformability, and was ready for enzyme immobilization. The electrochemical and spectroscopic measurements showed that the silica hybrid sol-gel provided excellent matrice for the enzyme immobilization and that the immobilized enzyme retained its bioactivity effectively. The immobilized GOD could catalyze the oxidation of glucose, which could be used to determine glucose at +1.0 V without help of any mediator. The competition between GOD and HEX for the substrate glucose involving ATP as a co-substrate led to a decrease of the glucose response, which allowed us to develop an ATP sensor with a good stability. The fabricated silica hybrid sol-gel matrice offered a stage for further study of immobilization and electrochemistry of proteins.  相似文献   

2.
We report the design, construction, and testing of a contact lens with an integrated amperometric glucose sensor, proposing the possibility of in situ human health monitoring simply by wearing a contact lens. The glucose sensor was constructed by creating microstructures on a polymer substrate, which was subsequently shaped into a contact lens. Titania sol-gel film was applied to immobilize glucose oxidase, and Nafion? was used to decrease several potential interferences (ascorbic acid, lactate, and urea) present in the tear film. The sensor exhibits a fast response (20s), a high sensitivity (240 μA cm(-2) mM(-1)) and a good reproducibility after testing a number of sensors. It shows good linearity for the typical range of glucose concentrations in the tear film (0.1-0.6 mM), and acceptable accuracy in the presence of interfering agents. The sensor can attain a minimum detection of less than 0.01 mM glucose.  相似文献   

3.
We report on the utilization of a novel nanoscaled cobalt phthalocyanine (NanoCoPc)-glucose oxidase (GOD) biocomposite colloid to create a highly responsive glucose biosensor. The biocomposite colloid is constructed under enzyme-friendly conditions by adsorbing GOD molecules on CoPc nanoparticles via electrostatic interactions. The glucose biosensor can be easily achieved by casting the biocomposite colloid on a pyrolytic graphite electrode (PGE) without any auxiliary matter. It has been found that GOD can be firmly immobilized on PGE surface and maintain its bioactivity after conjugating with NanoCoPc. NanoCoPc displays intrinsic electrocatalytic ability to the oxidation of the product of enzymatic reaction H2O2 and shows a higher catalytic activity than that of bulk CoPc. Under optimal conditions, the biosensor shows a wide linear response to glucose in the range of 0.02-18 mM, with a fast response (5s), high sensitivity (7.71 microA cm(-2) mM(-1)), as well as good thermostability and long-term life. The detection limit was 5 microM at 3 sigma. The general interferences coexisted in blood except ascorbic acid and L-cysteine do not affect glucose determination, and further coating Nafion film on the surface of the biosensor can effectively eliminate the interference from ascorbic acid and L-cysteine. The biosensor with Nafion film has been used for the determination of glucose in serum with an acceptable accuracy.  相似文献   

4.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a colloidal gold modified carbon paste electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -(449+/-1) mV in 0.1 M pH 5.0 phosphate buffer solution. The response showed a surface-controlled electrode process with an electron transfer rate constant of (38.9+/-5.3)/s determined in the scan rate range from 10 to 100 mV/s. GOD adsorbed on gold colloid nanoparticles maintained its bioactivity and stability. The immobilized GOD could electrocatalyze the reduction of dissolved oxygen and resulted in a great increase of the reduction peak current. Upon the addition of glucose, the reduction peak current decreased, which could be used for glucose detection with a high sensitivity (8.4 microA/mM), a linear range from 0.04 to 0.28 mM and a detection limit of 0.01 mM at a signal-to-noise ratio of 3sigma. The sensor could exclude the interference of commonly coexisted uric and ascorbic acid.  相似文献   

5.
Due to their unique physicochemical properties, doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, selecting glucose oxidase (GOD) as a model enzyme, we investigated the direct electrochemistry of GOD based on the B-doped carbon nanotubes/glassy carbon (BCNTs/GC) electrode with cyclic voltammetry. A pair of well-defined, quasi-reversible redox peaks of the immobilized GOD was observed at the BCNTs based enzyme electrode in 0.1M phosphate buffer solution (pH 6.98) by direct electron transfer between the protein and the electrode. As a new platform in glucose analysis, the new glucose biosensor based on the BCNTs/GC electrode has a sensitivity of 111.57 microA mM(-1)cm(-2), a linear range from 0.05 to 0.3mM and a detection limit of 0.01mM (S/N=3). Furthermore, the BCNTs modified electrode exhibits good stability and excellent anti-interferent ability to the commonly co-existed uric acid and ascorbic acid. These indicate that boron-doped carbon nanotubes are the good candidate material for the direct electrochemistry of the redox-active enzyme and the construction of the related enzyme biosensors.  相似文献   

6.
Yin B  Yuan R  Chai Y  Chen S  Cao S  Xu Y  Fu P 《Biotechnology letters》2008,30(2):317-322
A glucose biosensor based on layer-by-layer (LBL) self-assembling of chitosan and glucose oxidase (GOD) on a Prussian blue film was developed. First, Prussian blue was deposited on a cleaned gold electrode then chitosan and GOD were assembled alternately to construct a multilayer film. The resulting amperometric glucose biosensor exhibited a fast response time (within 10 s) and a linear calibration range from 6 μM to 1.6 mM with a detection limit of 3.1 μM glucose (s/n = 3). With the low operating potential, the biosensor showed little interference to the possible interferents, including ascorbic acid, acetaminophen and uric acid, indicating an excellent selectivity.  相似文献   

7.
A miniaturized glucose biosensor in which glucose oxidase (GOD) and poly(p-phenylenediamine) (poly-PPD) were coimmobilized at the surface of a platinum microdisk electrode was developed and used successfully for amperometric determination of glucose. The performance of sensors prepared at different monomer concentrations and polymerization potentials with different media was investigated in detail. It was found that similarly to poly(o-phenylenediamine) (poly-OPD), (poly-PPD) noticeably eliminated the electrochemical interference of ascorbic acid, uric acid, and l-cysteine. The amperometric response of glucose with the biosensor under optimal conditions exhibited a linear relationship in the range of 5.0 x 10(-5) to 3.0 x 10(-3) M with correlation coefficient 0.9995. According to the Michaelis-Menten equation, the apparent Michaelis constant for glucose and the maximum steady-state current density of the poly-PPD/GOD-modified microelectrode were 3.94 mM and 607.5 microA cm(-2), respectively. The current density of the sensor responding to glucose in the linear range can reach 160 microA cm(-2) mM(-1), which is far greater than that obtained using poly-OPD and poly(phenol) film. In addition, the stability of the sensor was examined over a 2-month period.  相似文献   

8.
A novel amperometric phenol sensor was constructed by immobilizing tyrosinase in a titania sol-gel matrix. The tyrosinase entrapped sol-gel film was obtained with a vapor deposition method, which simplified the traditional sol-gel process and avoided the shrinkage and cracking of conventional sol-gel-derived glasses. This matrix provided a microenvironment for retaining the native structure and activity of the entrapped enzyme and a very low mass transport barrier to the enzyme substrates. Phenol could be oxidized by dissolving oxygen in presence of immobilized tyrosinase to form a detectable product, which was determined at -150 mV without any mediator. The phenol sensor exhibited a fast response (less than 5 s) and sensitivity as high as 103 microA/mM, which resulted from the porous structure and high enzyme loading of the sol-gel matrix. The linear range for phenol determination was from 1.2x10(-7) to 2.6x10(-4) M with a detection limit of 1.0x10(-7) M. The apparent Michaelis-Menten constant of the encapsulated tyrosinase was calculated to be (0.29+/-0.02) mM. The stability of the biosensor was also evaluated.  相似文献   

9.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

10.
Glucose oxidase (GOD) was genetically modified by adding a poly-lysine chain at the C-terminal with a peptide linker inserted between the enzyme and poly-lysine chain. The poly-lysine chain was added in order to anchor more electron transfer mediator, ferrocenecarboxylic acid, to GOD for the purpose of improving sensitivity and stability of glucose biosensors. The modified GOD had similar K(m) and K(cat) to those of the wild type enzyme. After interacted with the electron transfer mediator, the modified enzyme retained 90.01% of its native activity, while the commercial GOD and the wild type GOD (Aspergillus niger) retained only 22.43 and 22.17%, respectively. Screen-printed electrodes coated with the modified GOD, wild type yeast-derived GOD or the commercial GOD were tested in glucose solution of different concentrations. Experimental results showed that the biosensor based on the modified GOD gave the largest signal among the three. In addition, the linear range of the biosensor prepared by the modified GOD could extend to 45 mM, while they were about 20 mM for the biosensors based on the wild type yeast-derived enzyme and the commercial enzyme.  相似文献   

11.
A new type of chemically modified electrode based ring-disk electrode as the dual electrochemical detector (DECD) for high-performance liquid chromatography (HPLC) to simultaneously determine the monoamine neurotransmitters and glucose is described. The ring electrode was modified with an ion-exchange polymer-overoxidized polypyrrole (OPPy) and the disk electrode was modified with nano Au colloid and glucose oxidase (GOD). The electrochemical behaviors of dopamine (DA) and ascorbic acid (AA) at the OPPy chemically modified electrode (CME) were investigated by differential pulse voltammetry (DPV). It was found that the CME could permeate dopamine cations and repelled the ascorbate anions, which could be used to determine the monoamine neurotransmitters and avoid the interference of AA. The electrochemical behavior of glucose at the Nafion/GOD-Au colloid/GC CME was investigated by amperometry and flow injection analysis (FIA). It was found that the sensitivity of the CME increased apparently in determination of glucose. In order to obtain better separation and current responses of the analytes in HPLC-DECD, several operational parameters have been investigated. Under the optimum conditions, the method showed good stability and reproducibility. The application of this method coupled with microdialysis sampling for in vivo simultaneous determination of monoamine neurotransmitters and glucose in rat brain was satisfactory.  相似文献   

12.
Li J  Lin X 《Biosensors & bioelectronics》2007,22(12):2898-2905
Novel Pt nanoclusters embedded polypyrrole nanowires (PPy-Pt) composite was electrosynthesized on a glassy carbon electrode, denoted as PPy-Pt/GCE. A glucose biosensor was further fabricated based on immobilization of glucose oxidase (GOD) in an electropolymerized non-conducting poly(o-aminophenol) (POAP) film that was deposited on the PPy-Pt/GCE. The morphologies of the PPy nanowires and PPy-Pt nanocomposite were characterized by field emission scanning electron microscope (FE-SEM). Effect of experimental conditions involving the cycle numbers for POAP deposition and Pt nanoclusters deposition, applied potential used in glucose determination, temperature and pH value of the detection solution were investigated for optimization. The biosensor exhibited an excellent current response to glucose over a wide linear range from 1.5 × 10−6 to 1.3 × 10−2 M (r = 0.9982) with a detection limit of 4.5 × 10−7 M (s/n = 3). Based on the combination of permselectivity of the POAP and the PPy films, the sensor had good anti-interference ability to ascorbic acid (AA), uric acid (UA) and acetaminophen. The apparent Michaelis–Menten constant (Km) and the maximum current density (Im) were estimated to be 23.9 mM and 378 μA/cm2, respectively. In addition, the biosensor had also good sensitivity, stability and reproducibility.  相似文献   

13.
The present communication demonstrates a relatively green preparative route toward Au nanoplates in aqueous solution at room temperature with the use of tannic acid (TA), which is an environmentally friendly, soluble polyphenol, as a reducing agent. Such Au nanoplates exhibit notable catalytic performance toward the oxidation and reduction of H(2)O(2). A glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) into chitosan-Au nanoplate composites film on the surface of glassy carbon electrode (GCE). This sensor exhibits good response to glucose, and the linear response range is estimated to be from 2 to 20 mM (R=0.999) at 0.65 V and from 2 to 10 mM (R=0.993) at -0.2 V, respectively. The sensitivity of the sensor determined from the slopes is 49.5 μA mM(-1)cm(-2) at 0.65 V.  相似文献   

14.
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.  相似文献   

15.
One-step construction of Pt nanoparticles-chitosan composite film (PtNPs-CS) was firstly proposed as a novel immobilization matrix for the enzymes to fabricate glucose biosensor. This novel interface embedded in situ PtNPs in CS hydrogel was developed by one-step electrochemical deposition in solution containing CS and chloroplatinic acid (H(2)PtCl(6)). Several techniques, including scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry were employed to characterize the assembly process and performance of the biosensor. Under the optimized experimental conditions, the resulting biosensor exhibited excellent linear behavior in the concentration range from 1.2 μM to 4.0 mM for the quantitative analysis of glucose with a limit of detection of 0.4 μM at a signal-to-noise ratio of 3. The apparent Michaelis-Menten constant (K(M)(app)) was evaluated to be 2.4 mM, showing good affinity. The proposed biosensor offered good amperometric responses to glucose due to the nanostructured sensing film provided plenty of active sites for the immobilization of glucose oxidase (GOD).  相似文献   

16.
The in-vivo behaviour of microfabricated GOD (glucose oxidase)/H2O2 glucose sensor implanted subcutaneously in normal anaesthetized rats has been studied. The sensor consists of a planar, three-electrode microcell, an enzyme membrane (glucose oxidase and bovine serum albumin cross-linked with glutaraldehyde) and an outer diffusion limiting polyurethane membrane. The sensor behaviour during hyperglycaemic (13.8 mM and 11.2 mM), euglycaemic (7.8 mM) and hypoglycaemic (3.5 mM) plateau levels was determined. The values of the in-vivo sensitivity (0.64 +/- 0.05 nA/mM) and background current (1.25 +/- 0.4 nA) were determined using a two-point calibration method and then used to calculate apparent subcutaneous glucose concentrations. The results show the presence of a good correlation between all the plasma glucose levels (G) and the apparent subcutaneous tissue concentrations (G'), with G' = 0.997.G - 0.066, r = 0.9782.  相似文献   

17.
A flow-injection analysis (FIA) system based on fibre optic detection of oxygen consumption using immobilized glucose oxidase (GOD) and lactate oxidase (LOD) is described for the on-line monitoring of glucose and lactate concentrations in animal cell cultures. The consumption of oxygen was determined via dynamic quenching by molecular oxygen of the fluorescence of an indicator. GOD and LOD were immobilized on controlled pore glass (CPG) in enzyme reactors which were directly linked to a specially designed fibre optic flow-through cell covering the oxygen optrode. The system is linear for 0-30 mM glucose, with an r.s.d. of 5% at 30 mM (five measurements) and for 0-30 mM lactate, with an r.s.d. of 5% at 30 mM (five measurements). The enzyme reactors used were stable for more than 4 weeks in continuous operation, and it was possible to analyse up to 20 samples per hour. The system has been successfully applied to the on-line monitoring of glucose and lactate concentrations of an animal cell culture designed for the production of recombinant human antithrombine III (AT-III). Results of the on-line measurement obtained by the FIA system were compared with the off-line results obtained by a glucose and lactate analyser from Yellow Springs Instrument Company (YSI).  相似文献   

18.
A novel amperometric glucose biosensor based on the nine layers of multilayer films composed of multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide cross-linking reaction, respectively. A cleaned Pt electrode was immersed in PAA, MWCNTs, cysteamine and GNp, respectively, followed by the adsorption of GOD, assembling the one layer of multilayer films on the surface of Pt electrode (GOD/GNp/MWCNTs/Pt electrode). Repeating the above process could assemble different layers of multilayer films on the Pt electrode. PBS washing was applied at the end of each assembly deposition for dissociating the weak adsorption. Film assembling and characterization were studied by transmission electron microscopy and quartz crystal microbalance, and properties of the resulting glucose biosensors were measured by electrochemical measurements. The marked electrocatalytic activity of Pt electrode based on multilayer films toward H2O2 produced during GOD enzymatic reactions with glucose permitted effective low-potential amperometric measurement of glucose. Taking the sensitivity and selectivity into consideration, the applied potential of 0.35 V versus Ag/AgCl was chosen for the oxidation detection of H2O2 in this work. Among the resulting glucose biosensors, the biosensor based on nine layers of multilayer films was best. It showed a wide linear range of 0.1–10 mM glucose, with a remarkable sensitivity of 2.527 μA/mM, a detection limit of 6.7 μM estimated at a signal-to-noise ratio of 3 and fast response time (within 7 s). Moreover, it exhibited good reproducibility, long-term stability and the negligible interferences of ascorbic acid, uric acid and acetaminophen. The study can provide a feasible approach on developing new kinds of oxidase-based amperometric biosensors, and can be used as an illustration for constructing various hybrid structures.  相似文献   

19.
High activity of glucose oxidase (GOD) enzyme (immobilized in porous silica particles) is desirable for a better glucose biosensor. In this work, effect of pore diameter of two porous hosts on enzyme immobilization, activity and glucose sensing was compared. The hosts were amine functionalized: (i) microporous silica (NH2-MS) and (ii) mesoporous silica (NH2-SBA-15). Based on whether the dimension of GOD is either larger or smaller than the pore diameter, GOD was immobilized on either external or internal surface of NH2-MS and NH2-SBA-15, with loadings of 512.5 and 634 mg/g, respectively. However, GOD in NH2-SBA-15 gave a higher normalized absolute activity (NAA), which led to an amperometric sensor with a larger linear range of 0.4–13.0 mM glucose. In comparison, GOD in NH2-MS had a lower NAA and a smaller linear range of 0.4–3.1 mM. In fact, the present GOD-NH2-SBA-15 electrode based sensor was better than other MS and SBA-15 based electrodes reported in literature. Thus, achieving only a high GOD loading (as in NH2-MS) does not necessarily give a good sensor performance. Instead, a host with a relatively larger pore than enzyme, together with optimized electrode composition ensures the sensor to be functional in both hyper- and hypoglycemic range.  相似文献   

20.
The structure and biosensor characteristics of complex between glucose oxidase (GOD) and plasma-polymerized nanothin film (PPF), in which the thickness is several nanometers, were investigated by atomic force microscopy (AFM) and electrochemical measurement. The GOD molecules were densely adsorbed onto the PPF surface treated by nitrogen plasma and the individual GOD molecules were observed. Subsequently, the GOD densely packed array on the PPF surface was subsequently treated by plasma polymerization (overcoating). AFM image showed that the thicker film gave the smoother surface, indicating that the GOD adsorbed on the surface was embedded more deeply in PPF. The amperometric biosensor characteristics of the GOD-PPF complex on a platinum electrode showed the current increment due to the enzymatic reaction with glucose addition, indicating that enzyme activity was retained although the enzyme has been exposed to the plasma gas related to diffusion of the substrate. This means that under mild exposure to organic plasma, the enzyme does not become seriously dysfunctional. Amperometric biosensor characteristics were strongly affected by monomer and thickness of PPF overcoating related with the diffusion of the substrate (glucose). Considering that the film deposition was performed using microfabrication-compatible organic plasma, our new method for protein architecture has a great potential of enabling high throughput production of bioelectronic devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号