首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
This work shows the feasibility of an olfactory biosensor based on the immobilization of Saccharomyces cerevisiae yeast cells genetically modified to express the human olfactory receptor OR17-40 onto interdigitated microconductometric electrodes. This olfactory biosensor has been applied to the detection of its specific odorant (helional) with a high sensitivity (threshold 10−14 M). In contrast, no significant response was observed using a non-specific odorant (heptanal), which suggests a good selectivity. Thus, this work may represent a first step towards a new kind of bioelectronic noses based on whole yeast cells and allowing a real time monitoring of olfactory receptor activation. Presented at the joint biannual meeting of the SFB-GEIMM-GRIP, Anglet, France, 14–19 October, 2006.  相似文献   

3.
4.
Conductometric microbiosensors for the determination of trypsin were elaborated via the modification of microfabricated interdigitated gold electrodes by a cross-linked urease/BSA coating covered by a gelatin film. The resulting microelectrodes were exposed to different trypsin concentrations ranging from 100pg/mL to 1mg/mL (1mU/mL to 10,000U/mL) for selective proteolytic degradation of the gelatin film. Then, the conductometric response of the microbiosensors to urea (33muM) was recorded as a function of the trypsin concentration, the gelatin amount (8-80ng) and the incubation time (40s, 100min). The optimum incubation time for each trypsin concentration was determined leading to a detection limit of 100pg/mL (1mU/mL). In these optimized conditions, the proof of concept of this sensitive, disposable, low-cost and label-free trypsin biosensors based on a conductometric transducer was demonstrated for the first time.  相似文献   

5.
An optical waveguide array biosensor suitable for rapid detection of multiple bio-hazardous agents is presented. SpectroSens? optical microchip sensors contain multiple spatially-separated waveguide channels with integral high-precision Bragg gratings sensitive to changes in refractive-index; selective surface-functionalisation of discrete sensing channels with different antibodies as bio-recognition elements enables selective multi-analyte biological detection. Interactions between target antigens in the test sample and respective surface-immobilised antibodies result in localised changes in refractive-index; the biosensor response manifests as increases in wavelength of light reflected from specific sensing channels. Multiplexed, label-free detection of 8 different biological agents, encompassing bacterial spores, vegetative cells, viruses and proteinaceous toxins has been demonstrated in real-time. Selective detection of Bacillus atrophaeus (BG) spores, Escherichia coli cells, MS2 viruses and ovalbumin (OVA) protein (simulant bio-hazardous agents) was first demonstrated as proof-of-concept; subsequently, detection of Bacillus anthracis (BA) spores (UM23CL2 strain), Franciscella tularensis (FT) cells (live vaccine strain), Vaccinia viruses (heat-killed) and ricin toxin (bio-hazardous agents) was proven. Two optical microchip sensors, each comprising 8 sensing channels were packaged into a single disposable cartridge allowing simultaneous 16-channel data acquisition. The specific antibody deposition sequence used in this study enabled detection of either 4 simulants or 4 bio-hazardous agents using a single consumable. The final device, a culmination of the multidisciplinary convergence of the fields of biology, chemistry, optoelectronics and microfluidics, is man-portable and inherently robust. The performance characteristics of the SpectroSens? technology platform highlight its potential for exploitation as a ‘detect to warn/treat’ biodetector in security and defence operations.  相似文献   

6.
The detection limit of catecholamines can be lowered by using a carbon-based interdigitated array (IDA) microelectrode as a detector for liquid chromatography (LC). The IDA electrode is more sensitive than conventional glassy carbon electrodes due to the high current density caused by radial diffusion at each microband, and redox cycling between two microband arrays. Since the number of redox cycles increases at lower flow-rates, the carbon IDA is particularly useful for microbore LC. In an LC system with a 1-mm microbore column and a carbon IDA electrode, the peak height of dopamine (DA) and DOPAC did not decrease with decreasing flow-rate because of this redox cycling. A low detection limit of 5 fg (32 amol) and 9.6 fg (57 amol) was obtained for DA and DOPAC due to the high current density and low background noise level (0.1 pA) at the carbon IDA electrode. The total charge generated by oxidizing DA at the anodic array was more than the value calculated by assuming that all the DA molecules were oxidized.  相似文献   

7.
A novel impedimetric immunosensor for atrazine detection has been developed. The immunosensor is based on an array of interdigitated micro-electrodes (IDmicroE) and immunoreagents specifically developed to detect this pesticide. Immunochemical determination of atrazine is possible without the use of any label. An atrazine-haptenized protein was covalently immobilized on the surface of the interdigitated mu-electrodes area (interdigits space) previously activated with (3-glycidoxypropyl)trimethoxysilane. Before, the gold electrodes were blocked using N-acetylcysteamine to prevent non-specific adsorptions. All biofunctionalization steps were characterized by chemical affinity methods and impedance spectroscopy. Immunosensors measures are made by exposing the sensor to solutions containing a mixture of the analyte and the specific antibody. With this configuration, the immunosensor detects atrazine with a limit of detection of 0.04 microg L(-1) without the use of any label. The potential of the immunosensor to analyze pesticide residues in complex sample matrices, such as red wine, has been evaluated. The results shown that after solid-phase extraction atrazine can be determined in this type of sample with a limit of detection of 0.19 microg L(-1), far below the Maximum Residue Level (MRL) established by EC for residues of this herbicide in wine.  相似文献   

8.
A surface plasmon resonance array biosensor based on spectroscopic imaging   总被引:6,自引:0,他引:6  
We have developed a multi-element transduction system which combines conventional SPR spectroscopy with one-dimensional SPR microscopy to create an effective platform for monitoring binding events on macro- or micro-patterned receptor arrays created on disposable sensor chips. This creates an effective platform for monitoring simultaneous binding events on each of the regions patterned with the receptors. This system has been specifically designed with commercially available components to allow relatively easy duplication. Furthermore, this system can use a proven, simple method to compensate for changes in the bulk index of refraction of the solution containing the analytes due to changes in temperature or solute concentration with simple modifications to the sensor chips alone. Preliminary results demonstrate how this system can be used to monitor several independent biospecific binding events simultaneously.  相似文献   

9.
This work presents the synthesis of bacteria-mediated bioimprinted films for selective bacterial detection. Marine pathogen sulfate-reducing bacteria (SRB) were chosen as the template bacteria. Chitosan (CS) doped with reduced graphene sheets (RGSs) was electrodeposited on an indium tin oxide electrode, and the resulting RGSs-CS hybrid film served as a platform for bacterial attachment. The electrodeposition conditions were optimized to obtain RGSs-CS hybrid films with excellent electrochemical performance. A layer of nonconductive CS film was deposited to embed the pathogen, and acetone was used to wash away the bacterial templates. Electrochemical impedance spectroscopy was performed to characterize the stepwise modification process and monitor the SRB population. Faradic impedance measurements revealed that the charge transfer resistance (R(ct)) increased with increased SRB concentration. A linear relationship between ΔR(ct) and the logarithm of SRB concentration was obtained within the concentration range of 1.0×10(4)cfumL(-1) to 1.0×10(8)cfumL(-1). The impedimetric sensor showed good selectivity towards SRB based on size and shape. Hence, selectivity for bacterial detection can be improved if the bioimprinting technique is combined with other bio-recognition elements.  相似文献   

10.
Individual enzyme-based biosensors involving three-electrode systems were developed for the detection of analytes comprising markers of the stage of maturity and quality in selected fruits of economic importance to tropical countries. Importantly, a common fabrication format has been developed to simplify manufacture and allow future integration of the individual sensors into a single multi-sensor array. Specifically, sensors for beta-D-glucose, total D-glucose, sucrose and ascorbic acid have been developed. Pectin, a natural polysaccharide present in plant cells, was used as a novel matrix to enhance enzyme entrapment and stabilisation in the sensors. Except for ascorbic acid, all the sensors function via the detection of enzymatically generated H2O2 at rhodinised carbon electrodes. Since ascorbic acid is electrochemically active at the working potential chosen (+350 mV vs. Ag/AgCl), it was measured directly. Enzyme sensors demonstrated expected response with respect to their substrates, typically 0-0.8 microA/20 mm2 electrode area response over analyte ranges of 0-7 mM. Interferences related to electrochemically active compounds present in fruits under study were significantly reduced by inclusion of a suitable cellulose acetate (CA) membrane or by enzymatic inactivation with ascorbate oxidase. Initial development was carried out into production of biosensor arrays. CA membranes were used to improve the linear range of the sensors, producing up to a fivefold improvement in the detection range compared to sensors without an additional diffusion barrier.  相似文献   

11.
The temperature induced melting transition of a self-complementary DNA strand covalently attached at the 5′ end to the surface of a gold interdigitated microelectrode (GIME) was monitored in a novel, label-free, manner. The structural state of the hairpin was assessed by measuring four different electronic properties of the GIME (capacitance, impedance, dissipation factor and phase angle) as a function of temperature from 25°C to 80°C. Consistent changes in all four electronic properties of the GIME were observed over this temperature range, and attributed to the transition of the attached single-stranded DNA (ssDNA) from an intramolecular, folded hairpin structure to a melted ssDNA. The melting curve of the self-complementary single strand was also measured in solution using differential scanning calorimetry (DSC) and UV absorbance spectroscopy. Temperature dependent electronic measurements on the surface and absorbance versus temperature values measured in solution experiments were analyzed assuming a two-state process. The model analysis provided estimates of the thermodynamic transition parameters of the hairpin on the surface. Two-state analyses of optical melting data and DSC measurements provided evaluations of the thermodynamic transition parameters of the hairpin in solution. Comparison of surface and solution measurements provided quantitative evaluation of the effect of the surface on the thermodynamics of the melting transition of the DNA hairpin.  相似文献   

12.
An antibody-based electrochemical biosensing platform has been developed and used for the detection of protein. In the presence of the target, an antibody pair binds to the protein simultaneously, which causes two oligo-DNAs conjugated with the antibody pair to hybridize to each other and become a big “stem–loop” structure. Subsequently, the longer oligo-DNA of the stem, with a methylene blue (MB) label at the terminal, hybridizes stably with capture DNA owing to the enhancement of base stacking. The strong redox current signal of MB is used for protein quantification. Using α-fetoprotein (AFP) as a model, the proposed method could detect AFP at a concentration as low as 2 pg ml−1 with a dynamic range of 4 orders of magnitude, which approaches traditional assays such as enzyme-linked immunosorbent assay.  相似文献   

13.
Wu S  Zhang L  Qi L  Tao S  Lan X  Liu Z  Meng C 《Biosensors & bioelectronics》2011,26(6):2864-2869
A sensitive amperometric acetylcholinesterase (AChE) biosensor was fabricated based on mesocellular silica foam (MSF), which functioned as both an enzyme immobilization matrix and a solid phase extraction (SPE) material for the preconcentration of target molecules. The hydrophilic interface, the good mechanical/chemical stability, and the suitable pore dimension of MSF provided the entrapped AChE a good environment to well maintain its bioactivity at basic condition. The AChE immobilized in MSF showed improved catalytic ability for the hydrolysis of acetylthiocholine, as evidenced by the increasing of the oxidation current of thiocholine, the enzymatic catalytic hydrolysis production of acetylthiocholine. In addition, the MSF with large surface area showed a modest adsorption capacity for monocrotophos, a model organophosphate used in this study, via the hydrogen bond or physical adsorption interaction. The combination of the SPE and the good enzyme immobilization ability in MSF significantly promoted the sensitivity of the biosensor, and the limit of detection has lowered to 0.05 ng/mL. The biosensor exhibited accuracy, good reproducibility, and acceptable stability when used for garlic samples analysis. The strategy may provide a new method to fabricate highly sensitive biosensors for the detection of ultra-trace organophosphorous pesticide infield.  相似文献   

14.
We report a microfluidic sensing platform for the detection of thyroglobulin (Tg) using competitive protein adsorption. Serum Tg is a highly specific biomarker for residual thyroid tissue, recurrence and metastases after treatment for differentiated thyroid cancer (DTC). Conventional Tg detection techniques require complicated immobilization of antibodies and need to form a sandwich assay using additional secondary antibodies to enhance the sensitivity. We present a fundamentally different sensing technique without using antibody immobilization on a microfluidic platform. We engineer two surfaces covered by two known proteins, immunoglobulin G (IgG) and fibrinogen, with different affinities onto the surfaces. The microfluidic device offers a selective protein sensing by being displaced by a target protein, Tg, on only one of the surfaces. By utilizing the competitive protein adsorption, Tg displaces a weakly bound protein, IgG; however, a strongly bound protein, fibrinogen, is not displaced by Tg. The surface plasmon resonance (SPR) sensorgrams show that five human serum proteins, albumin, haptoglobin, IgG, fibrinogen and Tg, have different adsorption strengths to the surface and the competitive adsorption of individuals controls the exchange sequence. The adsorption and exchange are evaluated by fluorescent labeling of these proteins. Tg in a protein mixture of albumin, haptoglobin, and Tg is selectively detected based on the exchange reaction. By using the technique, we obviate the need to rely on antibodies as a capture probe and their attachment to transducers.  相似文献   

15.
In this protocol, the authors report a time-resolved fluorescence biosensor based on home-made europium complexes for highly sensitive detection of small molecules using adenosine as a model analyte. The fluorophore that used is europium complexes. Its signal can be measured in a time-resolved manner that eliminates most of the unspecific fluorescent background. The amino modified aptamer probe, which is designed to specifically recognize adenosine, is combined to the aldehyde-group modified glass slide by covalent bond. Europium complex-labeled a short ssDNA, designed to segment hybridize with aptamer probe is immobilized on the glass slide by hybridization reaction. In the presence of adenosine, the aptamer part is more inclined to bounds with adenosine and triggers structure-switching of the aptamer from aptamer/ssDNA duplex to aptamer/target complex. As a result, europium complexes-labeled ssDNA is forced to dissociate from the sensor interface, resulting in time-resolved fluorescence intensity decrease. The decrement intensity is proportional to the amount of adenosine. Under optimized assay conditions, a linear range (1.0×10(-8)M to 1.0×10(-7)M) is got with low detection limit of 5.61nM. The biosensor exhibits excellent selectivity and can provide a promising potential for aptamer-based adenosine detection.  相似文献   

16.
A new transducer for biosensor applications has been developed based on a three-dimensional interdigitated electrode array (IDEA) with electrode digits separated by an insulating barrier. Binding of molecules to a chemically modified surface of the transducer induces important changes in conductivity between the electrodes. Three-dimensional sensor shows considerable improvement compared with a standard planar IDEA design. The potential of the developed device as a sensor transducer to detect immunochemical and enzymatic reactions, as well as DNA hybridization events is demonstrated. The immunosensor allows direct detection of the antibiotic sulfapyridine and shows the IC(50) parameter value of 5.6 microgL(-1) in a buffer. Immunochemical determination occurs under competitive configurations and without the use of any label. Each modified sensor is of a single use. Nevertheless, biochemical reagents can be easily cleaned off the sensor surface for its reuse. Layer-by-layer method of used to deposit polyethyleneimine and glucose oxidase showed that the sensor is also highly effective for detecting single and multilayered molecular assemblies.  相似文献   

17.
A new method of preparing fiber-optic DNA biosensor and its array for the simultaneous detection of multiple genes is described. The optical fibers were first treated with poly-1-lysine, and then were made into fiber-optic DNA biosensors by adsorbing and immobilizing the oligonucleotide probe on its end. By assembling the fiber-optic DNA biosensors in a bundle in which each fiber carried a different DNA probe, the fiber-optic DNA biosensor array was well prepared. Hybridization of fluorescent- labeled cDNA ofp53 gene,N-ras gene andRb1 gene to the DNA array was monitored by CCD camera. A good result was achieved.  相似文献   

18.
A new method of preparing fiber-optic DNA biosensor and its array for the simultaneous detection of multiple genes is described. The optical fibers were first treated with poly-l-lysine, and then were made into fiber-optic DNA biosensors by adsorbing and immobilizing the oligonucleotide probe on its end. By assembling the fiber-optic DNA biosensors in a bundle in which each fiber carried a different DNA probe, the fiber-optic DNA biosensor array was well prepared. Hybridization of fluorescent- labeled cDNA of p53 gene, N-ras gene and Rb1 gene to the DNA array was monitored by CCD camera. A good result was achieved.  相似文献   

19.
Carbohydrate-mediated host-pathogen interactions are essential to bacterial and viral pathogenesis, and represent an attractive target for the development of antiadhesives to prevent infection. We present a versatile microelectrode array-based platform to investigate carbohydrate-mediated protein and bacterial binding, with the objective of developing a generalizable method for screening inhibitors of host-microbe interactions. Microelectrode arrays are well suited for interrogating biological binding events, including proteins and whole-cells, and are amenable to electrochemical derivitization, facilitating rapid deposition of biomolecules. In this study, we achieve microelectrode functionalization with carbohydrates via controlled polymerization of pyrrole to individual microelectrodes, followed by physisorption of neoglycoconjugates to the polypyrrole-coated electrodes. Bioactivity of the immobilized carbohydrates was confirmed with carbohydrate-binding proteins (lectins) detected by both fluorescent and electrochemical means. The platform's ability to analyze whole-cell binding was demonstrated using strains of Escherichia coli and Salmonella enterica, and the dose-dependent inhibition of S. enterica by a soluble carbohydrate antiadhesive.  相似文献   

20.
Yessotoxin (YTX) is a generic name for a group of lipophilic compounds recently discovered and chemically characterized. Association measurements were done in a resonant mirror biosensor. The instrument detects changes in the refractive index and/or thickness occurring within a few hundred nanometers form the sensor surface where a molecule is attached. We used aminosilane surfaces where phosphodiesterase 3',5'-cyclic-nucleotide-specific from bovine brain (PDEs) was immobilized. Over this immobilized ligand different amounts of YTX were added and typical association curve profiles were observed. These association curves fit a pseudo-first-order kinetic equation where the apparent association rate constant (k(on)) can be calculated. The value of this constant increases with YTX concentration. From the representation of k(on) versus YTX concentration we obtained the association rate constant (k(ass)) 248+/-40 M(-1)s(-1) and the dissociation rate constant (k(diss)) 9.36 x 10(-4)+/-1.72 x 10(-4)s(-1). From these values the kinetic equilibrium dissociation constant (K(D)) for YTX-PDEs association can be calculated. The value of this last constant is 3.74 x 10(-6)+/-8.25 x 10(-8)M YTX. The PDE-YTX association was used as a method suitable for determination of the toxin concentration in a shellfish sample. The assay had sufficient sensitivity and can be used on simple shellfish extracts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号