共查询到20条相似文献,搜索用时 15 毫秒
1.
M. A. Raggi C. Sabbioni G. Casamenti G. Gerra N. Calonghi L. Masotti 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1999,730(2):3854-211
In the present study, assays were improved for the determination of catecholamines in human plasma. High-performance liquid chromatography with electrochemical detection was employed for quantitative analysis. The influence of various parameters on chromatographic performance, such as the composition and the pH of the mobile phase, and the detection potential, was investigated. An accurate solid-phase extraction procedure, after catecholamine complexation with diphenylborate, was developed. The efficiency yield for all catecholamines was in the range 92–98%. Relative standard deviation values for repeatability and for intermediate precision were less than 2% and 3%, respectively, for all three analytes. 相似文献
2.
Mary Ann Elchisak Joanne H. Carlson 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1982,233(1):79-88
A rapid and simple method for the analysis of free and conjugated catecholamines in body tissues and fluids is described. The free catecholamines were isolated by standard alumina procedures before and after hydrolysis of the conjugated compounds to free compounds by heating the samples in perchloric acid. Free catecholamines were then separated by high-performance liquid chromatography and detected by electrochemical detection. Conjugated compound was the difference between the total and free amount in each sample. This method was utilized to measure free and conjugated norepinephrine, epinephrine, and dopamine in human urine and rat adrenal gland, and to measure free and conjugated dopamine in rat whole brain and kidney. 相似文献
3.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1991,567(1):240-247
A procedure for the determination of plasma catecholamine concentrations in critical care patients after dobutamine infusion is presented. A modified chromatographic system is required with an additional washing procedure to achieve maximum sensitivity and stable chromatographic conditions. The influence of storage time on the catecholamine concentrations of plasma samples is reported in detail. A time-dependent decrease in catecholamine concentrations of up to 12 and 39% was found within two and ten months, respectively. 相似文献
4.
Machida M Watanabe M Takechi S Kakinoki S Nomura A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,798(2):187-191
Carvedilol is a beta/alpha1-adrenoceptor blocker. A sensitive method for measuring plasma levels of carvedilol in human administrated low doses is needed since its plasma concentration is low. We measured carvedilol and carvedilol M21-aglycon using high-performance liquid chromatography (HPLC) with electrochemical detection. The amperometric detector was operated at 930 mV versus Ag/AgCl. Mean coefficients of variation (n = 5) for carvedilol and M21-aglycon were 4.0 and 7.7% (intra) and 6.1 and 6.7% (inter), respectively. The lower limit of quantification for each analyte was 0.10 ng/ml (signal-to-noise ratio = 3). This lower limit of quantification for carvedilol was sufficient for clinical use. 相似文献
5.
6.
A sensitive method for the measurement of L-dihydroxyphenylalanine in plasma and other biological fluids is described. This method employs reversed-phase high performance liquid chromatography with electrochemical detection after adsorption by alumina and elution with acidic methanol. 相似文献
7.
Graeme Nigel Mahoney Wael Al-Delaimy 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,753(2):822
We have developed an assay for nicotine in hair based on reversed-phase HPLC with electrochemical detection. The method uses a low-metal, high-purity silica reversed-phase column. We have investigated the washing, digestion and extraction procedures and discuss the important points in the HPLC method development. The assay is presented as an application in a population of exposed and non-exposed children. Analytical parameters are satisfactory with linearity, recoveries, limit of quantitation and precision all suitable for epidemiological studies involving environmental tobacco smoke exposure assessment. 相似文献
8.
Patel BA Arundell M Parker KH Yeoman MS O'Hare D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,818(2):269-276
Using the CNS of Lymnaea stagnalis a method is described for the rapid analysis of neurotransmitters and their metabolites using high performance liquid chromatography coupled with electrochemical detection. Tissue samples were homogenised in ice-cold 0.1 M perchloric acid and centrifuged. Using a C(18) microbore column the mobile phase was maintained at a flow rate of 100 microl/min and consisted of sodium citrate buffer (pH 3.2)-acetonitrile (82.5:17.5, v/v) with 2 mM decane-sulfonic acid sodium salt. The potential was set at +750 mV versus Ag|AgCl reference electrode at a sensitivity of 50 nA full scale deflection. The detection limit for serotonin was 11.86 ng ml(-1) for a 5 microl injection. Preparation of tissue samples in mobile phase reduced the response to dopamine and serotonin compared with perchloric acid. In addition it was found that the storage of tissue samples at -20 degrees C caused losses of dopamine and serotonin. As a result of optimising the sample preparation and mobile phase the total time of analysis was substantially reduced resulting in a sample preparation and assay time of 15-20 min. 相似文献
9.
G. Alberts F. Boomsma A. J. Man in 't Veld M. A. D. H. Schalekamp 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,583(2)
We report a reliable fluorimetric assay for the simultaneous determination of norepinephrine, epinephrine, dopamine and dobutamine in human plasma and urine, based on liquid—liquid extraction and derivatization with the fluorogenic agent 1,2-diphenylethylenediamine prior to chromatography. The method is sensitive (detection limit 0.3–0.8 pg injected) and reproducible (coefficients of variation 1–10%), and shows good accuracy (93–98%). The method should also be used when one only wants to measure the concentrations of the natural catecholamines, in order to avoid interference by metabolites of dobutamine and by the late-eluting dobutamine itself. 相似文献
10.
Hideto Noguchi Koji Yoshida Mika Murano Shunsuke Naruto 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1992,573(2)
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm × 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)—acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml. 相似文献
11.
12.
A method was developed for the simultaneous assay of noradrenaline and adrenaline in 2 ml of human plasma. The method involves adsorption of the catechols onto alumina, desorption, lyophilizing, reconstitution, and injection into a reverse-phase ion-pairing liquid chromatography system. Sensitivity and selectivity are introduced using direct electrochemical detection of the column eluant. 相似文献
13.
James Q. Rose William J. Jusko 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1979,162(3):273-280
A sensitive, specific, and reproducible high-performance liquid chromatographic assay for the simultaneous determination of prednisone, prednisolone and cortisol in biological fluids was developed with dexamethasone as the internal standard. Samples are extracted with methylene chloride, washed with sodium hydroxide and then water, and chromatographed on a microparticulate silica gel column with UV detection at 254 nm. Sensitivity was greater than 15 ng for all four steroids. Specificity was supported by use of dual wavelength UV detection and/or radioimmunoassay. The assay has been applied in pharmacokinetic studies and a typical plasma concentration—time profile for the three steroids is presented for one subject who received 50 mg of prednisone. 相似文献
14.
Measurement of amoxicillin in plasma and gastric samples using high-performance liquid chromatography with fluorimetric detection 总被引:1,自引:0,他引:1
Wibawa JI Fowkes D Shaw PN Barrett DA 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,774(2):141-148
A rapid, selective and sensitive HPLC assay has been developed for the routine analysis of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue which is applicable to low concentrations of amoxicillin (<1 microg mL(-1)) or small sample volumes. Amoxicillin was converted, via an internal rearrangement, to form a fluorescent product which was subsequently recovered using liquid-liquid extraction. A Kromasil ODS 3 microm (150 x 3.2 mm I.D.) column was maintained at 40 degrees C and used with a mobile phase consisting of methanol-water (55:45, v/v). Fluorimetric detection was at an lambda(ex) of 365 nm and an lambda(em) of 445 nm. The limits of quantitation for amoxicillin were 0.1 microg mL(-1) for gastric juice aspirate (500 microL), 0.5 microg mL(-1) for plasma (50 microL) and 0.075 microg g(-1) for gastric tissue (250 mg). The method was linear up to at least 15 microg mL(-1) in gastric juice aspirate, up to 200 microg mL(-1) in plasma and up to 100 microg g(-1) in gastric tissue, with inter- and intra-day RSDs being less than 19%. The assay has been applied to the measurement of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue for pharmacokinetic studies in individual rats. 相似文献
15.
A rapid and sensitive method is described for the measurement of picomole levels of the biological thiols glutathione, cysteine, penicillamine, cysteamine, and ergothioneine by a combination of high-performance liquid chromatography and electrochemical detection (ECD). The compounds were separated isocratically on a reversed-phase C18 column by ion-pair chromatography with a mobile phase containing 5 mM acetic acid and 2.5 mM sodium 1-octanesulfonate. After chromatographic separation, the eluate was combined with silver nitrate dissolved in ammonium nitrate buffer at pH 10.5. A platinum disc electrode was used at -0.1 V vs Ag/AgCl to detect the amount of silver ions that had been consumed by the reaction with thiols. For measurement of disulfide, S-sulfonation with sodium sulfite or electroreduction were used to cleave the disulfide, and the thiol anions produced were detected by HPLC-ECD as for the reduced forms. The method was used to assay thiols and disulfides in biological materials. 相似文献
16.
Nitric oxide (NO) is a lipophilic gaseous molecule synthesized by the enzymatic oxidation of L-arginine. During periods of inflammation, phagocytic cells generate copious quantities of NO and other reactive oxygen species. The combination of NO with other reactive oxygen species promotes nitration of ambient biomolecules, including protein tyrosine residues and membrane-localized gamma-tocopherol. The oxidative chemistry of NO and derived redox congeners is reviewed. Techniques are described for the determination of 3-nitro-tyrosine and 5-nitro-gamma-tocopherol in biological samples using high-performance liquid chromatography with electrochemical detection. 相似文献
17.
Measurement of total plasma cysteamine using high-performance liquid chromatography with electrochemical detection 总被引:5,自引:0,他引:5
Cysteamine is currently used to treat children with the inherited disorder nephropathic cystinosis. A method for the quantitative determination of this aminothiol in human plasma is presented. Whole plasma was reduced with sodium borohydride to convert disulfides to thiols. Cysteamine was then separated by high-performance liquid chromatography and detected electrochemically. The recovery of standard cysteamine added to plasma was 96.6 +/- 1.9%. In a patient with cystinosis, an oral dose of cysteamine was absorbed rapidly, with plasma cysteamine reaching a maximum of 56 microM 1 h after the dose. By 1.8 h the plasma cysteamine concentration had decreased to one-half the maximum value. 相似文献
18.
19.
Robert E. Weinfeld Teresita C. Macasieb 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1979,164(1):73-84
A rapid, sensitive, and specific high-performance liquid chromatographic assay was developed for the determination of trimethoprim in blood, plasma, and urine using normal-phase (adsorption) chromatography on a microparticulate silica column and UV monitoring at 280 nm. Trimethoprim is selectively extracted from the biological sample matrix at alkaline pH with chloroform, providing nearly quantitative extraction (>95%) and a sensitivity limit of 0.01 to 0.02 μg/ml blood or plasma, without interference from sulfonamides. 相似文献
20.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1997,692(1):149-156
A reversed-phase HPLC method to quantify amiprilose in human plasma is described. The method involves liquid–liquid extraction of amiprilose and the internal standard from plasma. The extracted compounds are derivatized with 1,8-naphthalic dicarboxylic acid using 2-chloro-1-methylpyridinium iodide as a coupling reagent. The derivatized products are separated on a reversed-phase column and monitored fluorimetrically using 280 nm and 340 nm as excitation and emission wavelengths, respectively. The derivatized products which exhibit two peaks on chromatogram, are shown to be the interconvertible isomers. This assay has been used in pharmacokinetic studies of amiprilose in humans. 相似文献