首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
本文概述了当前生物传感器的研究特点以及发展DNA生物传感器的迫切性;从不同角度阐述了DNA生物传感器的概念和研究内容;着重讨论了DNA生物传感器的研究现状和发展趋势。文中分别对DNA光生物传感器和DNA压电晶体生物传感器的基本原理、特点、研究进展及存在的问题进行了分析与说明。进而,对我国DNA生物传感器研究存在的差距和发展前景进行了简要论述。  相似文献   

2.
表面等离子共振(surface plasmon resonance,SPR)技术旨在检测物体表面附近折射率的变化,其特点是无标记、实时、灵敏和快速,该技术多用于研究分子的相互作用,包括动力学、效率常数和大分子构象变化等。电化学(electrochemical,EC)技术是一项用于定性定量研究电子转移、物质氧化还原、界面吸附等过程的成熟技术,具有简单、低成本和设备小型化的优点。现有的DNA杂交技术,例如光学、电化学或压电转导技术,主要关注于提高DNA杂交检测系统的选择性和灵敏度。传统的SPR在DNA分析方面,由于无法测量折射率的极小变化而在超灵敏检测中的应用受到限制。因此,随着纳米材料的研发和联用技术的飞速发展,SPR与EC联用的生物传感器研究越来越成为人们关注的热点。近年来,关于SPR和EC联用在DNA检测方面的综述鲜有报道。对SPR和EC检测DNA的技术原理、联用方法、应用进展等方面作出了简要的介绍,以期为表面等离子共振和电化学联用的DNA传感器相关研究提供参考。  相似文献   

3.
We have investigated the sensitivity of ex situ (analysis under air condition) and in situ (analysis under liquid condition) spectral SPR sensors, which were self-constructed with fiber optic spectrometers. The sensitivity of SPR sensors was analyzed in the wavelength range of 550-780 nm by the interactions of streptavidin and biotinylated IgG, and the sensitivity was dependent on the wavelength of measurements. The sensitivity of an ex situ SPR sensor operated at the long wavelength range from 712 nm was approximately 2.6 times higher than that at the short wavelength range from 571 nm. In addition, the sensitivity of an ex situ spectral SPR sensor was about twice as high as that of an in situ spectral SPR sensor for the same resonance wavelength range. This was interpreted in that the difference in sensitivity between two SPR sensors was significantly caused by the evanescent field intensity at the metal/dielectric interface. Thus, it was suggested that ex situ spectral SPR sensors operated at the long wavelength range are sensitive biosensors for the high-throughput analysis of protein interactions on protein arrays.  相似文献   

4.
In this study, we theoretically investigate the sensing potential of 2D nano- and micro-ribbon grating structuration on the surface of Kretschmann-based surface plasmon resonance (SPR) biosensors when they are employed for detection of biomolecular binding events. Numerical simulations were carried out by employing a model based on the hybridization of two classical methods, the Fourier modal method and the finite element method. Our calculations confirm the importance of light manipulation by means of structuration of the plasmonic thin film surfaces on the nano- and micro-scales. Not only does it highlight the geometric parameters that allow the sensitivity enhancement compared with the response of the conventional SPR biosensor based on a flat surface but also describes the transition from the regime where the propagating surface plasmon mode dominates to the regime where the localized surface plasmon mode dominates. An exhaustive mapping of the biosensing potential of the 2D nano- and micro-structured biosensors surface is presented, varying the structural parameters related to the ribbon grating dimensions, i.e., the widths and thicknesses. The nano- and micro-structuration also leads to the creation of regions on biosensor chips that are characterized by strongly enhanced electromagnetic (EM) fields. New opportunities for further improving the sensitivity are offered if localization of biomolecules can be carried out in these regions of high EM fields. The continuum of nano- and micro-ribbon structured biosensors described in this study should prove a valuable tool for developing sensitive and reliable 2D-structured plasmonic biosensors.  相似文献   

5.
The detection performance of conventional surface plasmon resonance (SPR) biosensors is limited to a 1 pg/mm(2) surface coverage of biomolecules, and consequently, such sensors struggle to detect the interaction of small molecules in low concentrations. The present study is attempted to propose the use of a novel SPR biosensor with Au nanoclusters embedded in a dielectric film to achieve a 10-fold improvement in the resolution performance. A co-sputtering method utilizing a multi-target sputtering system is used to fabricate the present dielectric films (SiO(2)) with embedded Au nanoclusters. It is shown that the sensitivity of the developed SPR biosensor can be improved by adjusting the size and volume fraction of the embedded Au nanoclusters in order to control the surface plasmon effect. The present gas detection and DNA hybridization experimental results confirm that the proposed Au nanocluster-enhanced SPR biosensor provides the potential to achieve an ultrahigh-resolution detection performance of approximately 0.1 pg/mm(2) surface coverage of biomolecules.  相似文献   

6.
Surface plasmon resonance (SPR), a label-free, real time optical detection principle, has been investigated for its potential to detect and quantitate macromolecular ligand-ligate interactions. As model systems, the interactions of the HIV-1 envelope glycoprotein, gp120, and the monoclonal antibody L-71, with a soluble form of the T-cell receptor CD4 (sCD4), were investigated. In an effort to demonstrate potential analytical applications of this technology, operational characteristics of the SPR instrumentation (BIAcore, Pharmacia) including stability of the sensing surface and reproducibility in the measurement of such macromolecular interactions were investigated. In addition, the ability to detect and quantitate sCD4 directly from unfractionated cell culture supernatants, such as Streptomyces lividans, was investigated. The results demonstrate that SPR has potential in quantitating macromolecular interactions in both purified and crude samples and that the reproducibility in, and sensitivity of, such determinations is comparable to other techniques.  相似文献   

7.

The 2D material tin selenide monolayer (SnSe) has attracted a lot of attention due to its excellent optoelectronic properties. This study focuses on the investigation of the potential improvement of the response of surface plasmon resonance (SPR) sensors by coating the gold layer with SnSe allotrope (α, δ, ε) monolayers. Using an optimization algorithm along with the transfer matrix method (TMM), we determined the optimal thickness of the gold layer as a function of the number of monolayers added to significantly increase the sensor’s response in terms of reflectivity and phase. With respect to reflectivity, sensitivity increased by 20% in comparison with the optimal bare gold structure, whilst with respect to phase, sensitivity was approximately two orders of magnitude greater than the bare gold structure. Our results demonstrate that SPR sensors modified with SnSe monolayers could be used in diagnostic applications where both high sensitivity and small concentration of analyte are required.

  相似文献   

8.
A large majority of surface plasmon resonance (SPR) sensors reported in the literature are designed to operate in the visible electromagnetic spectrum. However, the near-infrared, particularly at the telecommunications wavelength of 1550 nm, is also especially attractive for SPR sensing applications. In fact, SPR sensors operating in this region benefit from narrower resonance and deeper field penetration. In this paper, we report a theoretical and experimental study of an SPR sensor operating at a fixed wavelength of 1550 nm. The influence of the choice of metals and the interrogation methods on the sensitivity of the resulting SPR sensor is investigated. Two types of sensor chips (simple gold (Au) and bimetallic silver/Au structure) and three interrogation methods (monitoring of the position of the reflectivity minimum, the position of the centroid, and the intensity evolution of the reflectivity) are examined. We show that a refractive index resolution of 2.7?×?10?6 refractive index unit can be easily obtained, and with further optimization of the measurement system, the ultimate limit of detection is expected to be even lowered. Therefore, the approach discussed here already shows a promising potential for highly sensitive SPR sensors.  相似文献   

9.
Owing to its large surface-to-volume ratio and good biocompatibility, graphene has been identified as a highly promising candidate as the sensing layer for fiber optic sensors. In this paper, a graphene/Au-enhanced plastic clad silica (PCS) fiber optic surface plasmon resonance (SPR) sensor is presented. A sheet of graphene is employed as a sensing layer coated around the Au film on the PCS fiber surface. The PCS fiber is chosen to overcome the shortcomings of the structured microfibers and construct a more stable and reliable device. It is demonstrated that the introduction of graphene can enhance the intensity of the confined electric field surrounding the sensing layer, which results in a stronger light-matter interaction and thereby the improved sensitivity. The sensitivity of graphene-based fiber optic SPR sensor exhibits more than two times larger than that of the conventional gold film SPR fiber optic sensor. Furthermore, the dynamic response analyses reveal that the graphene/Au fiber optic SPR sensor exhibits a fast response (5 s response time) and excellent reusability (3.5% fluctuation) to the protein biomolecules. Such a graphene/Au fiber optic SPR sensor with high sensitivity and fast response shows a great promise for the future biochemical application.  相似文献   

10.
One critical aspect for the development of label-free immunosensors is the employment of highly uniform and repeatable antibody immobilization techniques. In this study, we investigated the use of two different silane molecules (3-glycidyloxypropyl)trimethoxysilane (GPS), and (3-mercaptopropyl)trimethoxysilane (MTS) for the immobilization of fluorescently labeled IgG antibodies on planar ZnO surfaces. The chemical modification of the surfaces was investigated using water contact angle measurements, AFM, and fluorescence microscopy. The results of the water contact angle measurements indicate increased surface hydrophobicity after treatment with GPS and MTS as compared to the control. Surface modification was further verified through AFM measurements which demonstrate an increased surface roughness and particle height after treatment with antibodies. The results of the fluorescence studies indicate that the immobilization protocol employing MTS produced 21% higher fluorescence on average with greater uniformity than the GPS-based protocol, which indicates a higher overall density in antibody coverage on the surface of the ZnO. Acoustic sensor tests were employed to confirm the functionality of sensors treated with the MTS protocol. The results indicate that the immobilization protocol imparts sensitivity and specificity to the ZnO-based devices.  相似文献   

11.
Conventional techniques for the detection of biomolecular interactions can be limited by the need for exogenous labels, time- and labor-intensive protocols, as well as by poor sensitivity levels. A refractometer instrument has been reconfigured to detect biomolecular interactions through changes in surface plasmon resonance (SPR). The binding kinetics and affinity values of anti-NY-ESO-1 monoclonal antibody, ES121, to the cancer-testis antigen NY-ESO-1 were determined according to the surface heterogeneity model and resulted in K(D) values of 1.3x10(-9) and 2.1x10(-10) M. The reconfigured instrument was then used to measure the interaction between tumor antigens and serum antibodies against these antigens in preselected cancer patient sera samples. The tumor antigens assayed included NY-ESO-1, SSX2 and p53, all used as recombinant proteins containing polyhistidine tags. These results demonstrated that the instrument is capable of detecting the binding of serum antibodies from cancer patient sera to immobilized tumor antigens, consistent with those observed previously in ELISA-based experiments. These results demonstrate the potential of SPR technology for the rapid diagnosis and monitoring immune responses.  相似文献   

12.
In this study we evaluate the strengths and weaknesses of surface plasmon resonance (SPR) spectroscopy and quartz crystal microbalance (QCM) technique for studying DNA assembly and hybridization reactions. Specifically, we apply in parallel an SPR instrument and a 5 MHz QCM device with dissipation monitoring (QCM-D) to monitor the assembly of biotinylated DNA (biotin-DNA) on a streptavidin-modified surface and the subsequent target DNA hybridization. Through the parallel measurements, we demonstrate that SPR is more suitable for quantitative analysis of DNA binding amount, which is essential for interfacial DNA probe density control and for the analysis of its effect on hybridization efficiency and kinetics. Although the QCM is not quantitative to the same extent as SPR (QCM measures the total mass of the bound DNA molecules together with the associated water), the dissipation factor of the QCM provides a qualitative measure of the viscoelastic properties of DNA films and the conformation of the bound DNA molecules. The complexity in mass measurement does not impair QCM's potential for a kinetic evaluation of the hybridization processes. For quantification of target DNA, the biotin-DNA modified SPR and QCM sensors are exposed to target DNA with increasing concentration. The plots of SPR/QCM signals versus target DNA concentration show that water entrapment between DNA strands make the QCM sensitivity for the hybridization assay well comparable with that of the SPR, although the intrinsic mass sensitivity of the 5 MHz QCM is approximately 20 times lower.  相似文献   

13.
Functionalization of a gold surface is usually accomplished by covalent binding via self-assembled monolayers (SAMs) on the gold surface, followed by attachment of flexible polymeric linker layers such as dextran hydrogels. However, these techniques require multiple steps and also have nonspecific interactions and steric problems. In this study, a self-assembled carboxylated terthiophene monolayer was formed onto a gold surface to create a sensitive and stable surface plasmon resonance (SPR) biosensing system. Compared with a commercial carboxymethyl dextran chip (CM5), the terthiophene SAM surface provided more than six times more antibody-binding signals and nearly three times the SPR assay sensitivity for progesterone (P4).  相似文献   

14.
In this study, we prepared metallic corrugated structures for use as highly sensitive plasmonic sensors. Relying on the direct nanoimprint-in-metal method, fabrication of this metallic corrugated structure was readily achieved in a single step. The metallic corrugated structures were capable of sensing both surface plasmon resonance (SPR) wavelengths and index-matching effects. The corrugated Au films exhibited high sensitivity (ca. 800 nm/RIU), comparable with or even higher than those of other reported SPR-based sensors. Because of the unique index-matching effect, refractometric sensing could also be performed by measuring the transmission intensity of the Au/substrate SPR mode-conveniently, without a spectrometer. In the last, we demonstrated the corrugated Au film was capable of sensing biomolecules, revealing the ability of the structure to be a highly sensitive biosensor.  相似文献   

15.
Mark A. Hink 《Protoplasma》2014,251(2):307-316
Originally developed for the field of physical chemistry, fluorescence fluctuation spectroscopy (FFS) has evolved to a family of methods to quantify concentrations, diffusion rates and interactions of fluorescently labelled molecules. The possibility to measure at the nanomolar concentration level and to combine these techniques with microscopy allow to study biological processes with high sensitivity in the living cell. In this review, the basic principles, challenges and recent developments of the most common FFS methods are being discussed and illustrated by intracellular applications.  相似文献   

16.
In this paper, a new simple approach for sensitivity optimization in surface plasmon resonance (SPR) chemosensors based on colorimetric ligands is presented. A new design of SPR sensor with tunable analytical wavelength (lambda(SPR)) was constructed for this purpose, to perform studies on the ligand absorbance spectra related sensitivity enhancement. Unlike commercial SPR sensors which operate at one lambda(SPR), the new device can be used for sensitivity analysis at selected lambda(SPR) in the range 550-750 nm, offering the possibility to identify the highest sensitivity lambda(SPR) in regard to the spectral changes of the selected ligand. Measurements can be easily done in ligand bulk solutions without immobilization steps. Sensitivity enhancement analysis and optimization of lambda(SPR) on chromogenic reagents with hypsochromic shift in their absorption spectra are demonstrated in this contribution. Optimal selection of analytical wavelength, set at the absorbance peak of chromogenic reagent Eriochrome Black T (EBT) was observed to result in up to two times increased SPR sensitivity to Cd(2+) compared to wavelengths selected in other parts of the ligand absorbance spectra, with a limit of detection (LOD) 0.2 ppm. The sensitivity enhancement at optimal lambda(SPR) was observed to be related to increased refractive index (n), drop in extinction coefficient (alpha) and simultaneous hypsochromic shift of the EBT absorbance spectra causing the lambda(SPR) to match the absorbance peak shoulder.  相似文献   

17.
Surface plasmon resonance-based immunoassays   总被引:8,自引:0,他引:8  
Surface plasmon resonance (SPR) has been successfully incorporated into an immunosensor format for the simple, rapid, and nonlabeled assay of various biochemical analytes. Proteins, complex conjugates, toxins, allergens, drugs, and pesticides can be determined directly using either natural antibodies or synthetic receptors with high sensitivity and selectivity as the sensing element. Immunosensors are capable of real-time monitoring of the antigen-antibody reaction. A wide range of molecules can be detected with lower limits ranging between 10(-9) and 10(-13) mol/L. Several successful commercial developments of SPR immunosensors are available and their web pages are rich in technical information. This review highlights many recent developments in SPR-based immunoassay, functionalizations of the gold surface, novel receptors in molecular recognition, and advanced techniques for sensitivity enhancement. Furthermore, it describes the challenge of current problems and provides some insights toward the future technologies.  相似文献   

18.
Plasmonics - Long-range surface plasmon resonance (LRSPR)-based sensors exhibit high sensitivity as compared to the conventional SPR sensors due to low losses. A high refractive index prism and low...  相似文献   

19.
A self-assembled 3D hydrogel-nanoparticle composite integrated surface plasmon resonance (SPR) sensor is reported here. The novel assembled substrate was developed by means of a surface mediated radical co-polymerization process to obtain a highly sensitive hydrogel-based thin film that possesses specific binding sites for target analytes. Initially, amino group modified gold nanoparticles (AuNPs) were covalently linked to acrylic acid monomer. Following this, N-isopropylacrylamide (NIPAAm) and AuNPs linked acrylic acid (AAc) monomers were randomly co-polymerized by the "grafting from" method in the presence of initiator and crosslinker onto the sensing surface. Surface characterization techniques were utilized to evaluate the thickness and composition of the hydrogel-nanoparticle film. The sensing platform was employed to study the binding kinetics and conformational changes of the ArsA ATPase as a consequence of binding trivalent arsenicals under a variety of conditions. ArsA, the catalytic subunit of the ArsAB arsenite (As(III)) translocating ATPase, is one of the five proteins encoded by the arsenical resistance (ars) operon of plasmid R773 in cells of Escherichia coli, that confers resistance to trivalent and pentavalent salts of the metalloid arsenic. SPR measurements indicate that the 3D hydrogel-nanoparticle coated sensors exhibited a higher sensitivity than that of the 2D AuNPs decorated sensors. Binding of As(III) to ArsA is greatly facilitated by the presence of magnesium ion and ATP.  相似文献   

20.
The refractive index resolution of a surface plasmon resonance (SPR) sensor has been significantly improved these years; however, higher sensing performance is always desired. In this work, we propose a line-monitoring, long-range SPR sensor whose resolution is much better than conventional SPR sensors. Also, in contrast to mono-channel detection, multichannel detection, using line-monitoring technique, can detect multiple channels concurrently. In this way, this system achieves a refractive index resolution of 4.0?×?10??7 refractive index units and can monitor multiple molecular interactions simultaneously. Finally, a model experiment detecting the Escherichia coli bacteria has demonstrated the potential for biomedical applications of this system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号