首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The laser scanning cytometer (LSC) is a new laboratory tool that offers increased sensitivity and specificity compared to traditional technology. By combining the properties of the advantages of flow cytometry and immunohistochemistry, LSC-based analysis allows the automated evaluation of testicular cells in general and meiosis in particular. Testicular cell smears with previous staining by propidium iodide were analyzed by LSC. The results were compared with those for flow cytometry. LSC is a new, applicable methodology for analyzing spermatogenesis schedule.  相似文献   

2.
The donor photobleaching method (T. M. Jovin and D. J. Arndt-Jovin. 1989. Annu. Rev. Biophys. Biophys. Chem. 18:271-308.) has been adapted to an ACAS 570 (laser scanning microscope) system to measure fluorescence resonance energy transfer (FRET) on individual human peripheral blood T cells. Photobleaching was completed in approximately 100 ms in our case and it followed double-exponential kinetics. The energy transfer efficiency (E) was approximately 20% between the CD4 epitopes OKT4-FITC and Leu-3a-PE as well as between OKT4E-FITC and OKT4-PE. E was approximately 8% between OKT4-FITC and Leu-4-PE (alpha CD3) and barely detectable (approximately 4%) from OKT4-FITC to Leu-5b-PE (alpha CD2). The E values obtained by the photobleaching method were highly reproducible both in repeated measurement of identical samples and in experiments with different batches of cells and were in agreement with the flow cytometric donor quenching measurements. As expected, E measured between primary and secondary layers of antibodies increased (from approximately 14% to approximately 28%) when F(ab')2 fragments were substituted for whole antibody molecules as the donor. On a T cell line we mapped the distance between the idiotypic determinant of the T cell receptor (TcR) and the Leu-4 epitope of CD3 as proximal as E = 28%, as compared to E = 4% between a framework TcR epitope and Leu-4. In the latter case, however, approximately 40% less Leu-4 was bound suggesting that the antigen binding site of TcR is in close proximity with one of the two CD3 epsilon chains, which hence are not equivalent.  相似文献   

3.
Tsukazaki Y  Numa Y  Zhao S  Kawamoto K 《Human cell》2000,13(4):221-228
There have been few reports on investigation of the cell kinetics of brain tumors using a laser scanning cytometer (LSC). We compared DNA analysis using a flow cytometer (FCM) with that by LSC using established cell lines of brain tumors, and we demonstrated the similarity of both analytical results. The DNA-index (DI) and proliferating index (PI) of various brain tumors were determined, and the results showed that these indices reflected the malignancy of the tumors. The DI values were higher for astrocytoma grade IV than for astrocytoma grade II, frequently showing an aneuploid pattern. The determination of DNA-ploidy using LSC, together with cryopathological diagnosis, was considered to be useful for deciding the area to be resected for glioma perioperatively and to be worth applying clinically.  相似文献   

4.
BACKGROUND: Fetal nucleated red blood cells (NRBC) present in the peripheral blood of pregnant women at low frequency are a potential target for noninvasive prenatal diagnostics. METHODS: CD71-enriched cells from male cord blood (CB) were stained for the gamma chain of HbF (Hb-gamma) and cytocentrifuged. Fluorescence in situ hybridization (FISH) was done for the Y chromosome. Following staining of the nucleus with TO-PRO-3, laser scanning cytometry was performed. Artificial mixtures of small volumes of male CB and blood drawn from nonpregnant females were analyzed. RESULTS: In CB, 59% of events double positive for Hb-gamma and TO-PRO-3 were identified as CB-NRBC. In contamination studies, male fetal CB-NRBC were identified perfectly on the basis of morphologic characteristics and FISH reactivity following relocation and visual assessment. Mean recovery was 8.7%. CONCLUSIONS: Laser scanning cytometry of preenriched fetal NRBC may offer a promising way for noninvasive prenatal diagnostics. This is because it provides a virtual enrichment step and the position on the slides of cells visually confirmed to correspond to fetal NRBC is known. Further experimental procedures on well-defined and located target cells may be feasible.  相似文献   

5.
We describe a custom one-photon (confocal) and two-photon all-digital (photon counting) laser scanning microscope. The confocal component uses two avalanche photodiodes (APDs) as the fluorescence detector to achieve high sensitivity and to overcome the limited photon counting rate of a single APD ( approximately 5 MHz). The confocal component is approximately nine times more efficient than our commercial confocal microscope (fluorophore fluo 4). Switching from one-photon to two-photon excitation mode (Ti:sapphire laser) is accomplished by moving a single mirror beneath the objective lens. The pulse from the Ti:sapphire laser is 109 fs in duration at the specimen plane, and average power is approximately 5 mW. Two-photon excited fluorescence is detected by a fast photomultiplier tube. With a x63 1.4 NA oil-immersion objective, the resolution of the confocal system is 0.25 microm laterally and 0.52 microm axially. For the two-photon system, the corresponding values are 0.28 and 0.82 microm. The system is advantageous when excitation intensity must be limited, when fluorescence is low, or when thick, scattering specimens are being studied (with two-photon excitation).  相似文献   

6.
A scanning electron microscope study of microvascular anastomoses.   总被引:1,自引:0,他引:1  
The abdominal aortas of 30 rats were sutured under an operating microscope. The results were studied under a scanning electron microscope at 8 different periods after operation, ranging from 3 minutes to one month. The observations are presented.  相似文献   

7.
Human cerebral arteries were obtained from autopsy, fixed under pressure, cut open, and tacked onto pieces of cork. For one artery the intima was partly teased away, exposing the media, and treated with a silver nitrate process. For another artery the adventitia was exposed. Both arteries were processed through graded ethanols and coated with gold paladium for the scanning electron microscope. The collagen fibers of the adventitia were approximately 5 mum in diameter and consisted of a bundle of microfilaments, each of which had a diameter of 800-1000 A (1 A = 10(-10) m). The collagen fibers were oriented parallel to the long axis of the artery. The muscle cells of the media had a diameter of 2-5 mum and were arranged circumferentially with a pitch of approximately 20 degrees. The collagen fibers of the media travel perpendicular to the muscle cells, and parallel to the long axis of the artery. The fibrillar components of the elastin in the intima had a diameter of approximately 700-1000 A and were arranged parallel to the long axis of the artery. It was postulated that the fibrillar part of the elastin was the elastic component of the elastin.  相似文献   

8.
A F Baradi  S N Rao 《Tissue & cell》1976,8(1):159-162
As seen in the scanning electron microscope, peritoneal mesothelial cells of the mouse diaphragm, anterior abdominal wall and intestinal serosa carry numerous microvilli. These microvilli are absent over certain areas of the cell surface and are sometimes, interlocked in meshwork patterns or coronal formation. The apical cell membranes of the mesothelium at the base of the microvilli, are invaginated by many plasmalemmal vesicles and vacuoles and carry a number of protruding spherical structures. Deep circular craters, giving the impression of stomata, are also visible.  相似文献   

9.
The relative slow scanning speed of a galvanometer commonly used in a confocal laser scanning microscopy system can dramatically limit the system performance in scanning speed and image quality, if the data collection is simply synchronized with the galvanometric scanning. Several algorithms for the optimization of the galvanometric CLSM system performance are discussed in this work, with various hardware controlling techniques for the image distortion correction such as pixel delay and interlace line switching; increasing signal-to-noise ratio with data binning; or enhancing the imaging speed with region of interest imaging. Moreover, the pixel number can be effectively increased with Acquire-On-Fly scan, which can be used for the imaging of a large field-of-view with a high resolution.  相似文献   

10.
We used scanning laser confocal microscopy to visualize sites of peroxidatic activity as detected by the diaminobenzidine (DAB) reaction. Imaging was achieved by employing the reflectance mode of this instrument. Intense reflectance was detected after DAB localization of endogenous granule-associated myeloperoxidase in neutrophils and of the exogenous tracer horseradish peroxidase in mouse oocytes. Detection of DAB reaction products with confocal reflectance microscopy will probably be an important addition to the utility of this cytochemical technique.  相似文献   

11.
12.
We describe a technique based on moment-analysis for the measurement of the average number of molecules and brightness in each pixel in fluorescence microscopy images. The average brightness of the particle is obtained from the ratio of the variance to the average intensity at each pixel. To obtain the average number of fluctuating particles, we divide the average intensity at one pixel by the brightness. This analysis can be used in a wide range of concentrations. In cells, the intensity at any given pixel may be due to bright immobile structures, dim fast diffusing particles, and to autofluorescence or scattering. The total variance is given by the variance of each of the above components in addition to the variance due to detector noise. Assuming that all sources of variance are independent, the total variance is the sum of the variances of the individual components. The variance due to the particles fluctuating in the observation volume is proportional to the square of the particle brightness while the variance of the immobile fraction, the autofluorescence, scattering, and that of the detector is proportional to the intensity of these components. Only the fluctuations that depend on the square of the brightness (the mobile particles) will have a ratio of the variance to the intensity >1. Furthermore, changing the fluorescence intensity by increasing the illumination power, distinguishes between these possible contributions. We show maps of molecular brightness and number of cell migration proteins obtained using a two-photon scanning microscope operating with a photon-counting detector. These brightness maps reveal binding dynamics at the focal adhesions with pixel resolution and provide a picture of the binding and unbinding process in which dim molecules attach to the adhesions or large molecular aggregates dissociate from adhesion.  相似文献   

13.
14.
15.
16.
《Journal of bryology》2013,35(4):531-532
Abstract

The study of the ornamentations of the spore walls of the Bryum capillare group under the scanning electron microscope has shown considerable differences between one species and another which are of taxonomic significance.  相似文献   

17.
18.
19.
Sea urchin embryos were observed with SEM during the first 2 h of reaggregation, following dissociation of the 16-cell stage. A dense meshwork, composed of elongated microvilli embedded in the hyaline layer, surrounds the egg during early development. The dissociation procedure strips off some of the meshwork layer leaving fewer and smaller microvilli on the cell surface. Shortly after reaggregation has begun, several types of cell extensions are formed, including filopodia, which anchor the cells to the substrate, and ruffles and pseudopods, which enable the cells to move. Possible factors involved in the behavior of dissociated cells are discussed with regard to (1) the source of additional membrane in the formation of new cell extensions; (2) the ability of the cells to move.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏