首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Salmeterol is an inhaled bronchodilator drug used for treatment of asthma. Its concentrations in plasma are very low or undetectable by previously developed methods. The present paper describes a method for analysis of salmeterol in human plasma with 2.5 pg/mL lower limit of quantitation. Despite the basic character of the drug the method uses mixed mode anion-exchange solid phase extraction for sample preparation combined with a column switching approach to minimize matrix effects. Samples are separated and detected by LC/MS/MS. The method is easy to use, only requires 0.5 mL of plasma and was validated for use in bioanalytical applications. The method does not suffer from interference from co-administered fluticasone propionate.  相似文献   

3.
Assessment of differential protein abundance from the observed properties of detected peptides is an essential part of protein profiling based on shotgun proteomics. However, the abundance observed for shared peptides may be due to contributions from multiple proteins that are affected differently by a given treatment. Excluding shared peptides eliminates this ambiguity but may significantly decrease the number of proteins for which abundance estimates can be obtained. Peptide sharing within a family of biologically related proteins does not cause ambiguity if family members have a common response to treatment. On the basis of this concept, we have developed an approach for including shared peptides in the analysis of differential protein abundance in protein profiling. Data from a recent proteomics study of lung tissue from mice exposed to lipopolysaccharide, cigarette smoke, and a combination of these agents are used to illustrate our method. Starting from data where about half of the implicated database protein involved shared peptides, 82% of the affected proteins were grouped into families, based on FASTA annotation, with closure on peptide sharing. In many cases, a common abundance relative to control was sufficient to explain ion-current peak areas for peptides, both unique and shared, that identified biologically related proteins in a peptide-sharing closure group. On the basis of these results, we propose that peptide-sharing closure groups provide a way to include abundance data for shared peptides in quantitative protein profiling by high-throughput mass spectrometry.  相似文献   

4.
Many physiological processes show a high degree of stereoselectivity, including the metabolism of xenobiotics as catalyzed by cytochrome P450 enzymes. An analysis of these chiral discrimination effects in drug metabolism is essential for an in-depth understanding of metabolic pathways that differ between enantiomers of a given chiral drug or metabolite thereof. Achiral chromatographic separation and structural identification followed by chiral analysis of metabolites from blood specimens usually requires a time-consuming multistage analytical technique. In an effort to optimize such a complicated analytical scheme, a novel two-dimensional online achiral-chiral liquid chromatography-tandem mass spectrometry (LC/LC-MS/MS) coupling method was developed by using a peak parking technique in combination with a makeup flow system. Metabolites were separated in the first dimension using a C18 reversed-phase system. A makeup eluent of water/methanol (95/5) was split into the flow before storing the metabolites separately on chiral cartridges. Subsequently, the metabolite enantiomers were eluted backward onto the analytical chiral column and separated, and the ratio of enantiomers was determined. The method was successfully validated with respect to limit of detection, linearity, intra- and interday accuracy, and precision. In the course of a human volunteer study investigating the influence of CYP (cytochrome) 2C9 genetic polymorphism on phenprocoumon (PPC) metabolism, we used this new two-dimensional online analytical technique for the analysis of PPC metabolites in plasma. The enantiomeric forms of 4'-, 6-, and 7-hydroxy-PPC metabolites as well as two novel metabolites were identified, and the ratio of the enantiomers was calculated. We found that the enantiomeric ratio for the different metabolites in the plasma sample of each measured individual differs markedly from a nearly 100% chiral discrimination for the two new putative metabolites. This new analytical coupling method possesses general utility in the analysis of chiral discrimination effects, particularly as it relates to pharmacokinetics and dynamics, a scientific field that is rapidly becoming an area of concern and interest.  相似文献   

5.
A new liquid chromatography mass spectrometry (LC/MS) method has been developed for the qualitative and quantitative analyses of phosphatidylcholine hydroperoxides (PC-OOH) in human plasma using a synthetic hydroperoxide (1-stearoyl-2-erucoyl-PC monohydroperoxide, PC 18:0/22:1-OOH) as an internal standard. 1-Stearoyl-2-linoleoyl-PC monohydroperoxide (PC 18:0/18:2-OOH) was identified in plasma by LC/MS by comparison with an authentic standard. The calibration curves obtained for 1-palmitoyl-2-linoleoyl-PC monohydroperoxide, PC 16:0/18:2-OOH and PC 18:0/18:2-OOH were linear throughout the calibration range (0.1–1.0 pmol). The limit of detection (LOD) (S/N = 3:1) was 0.01 pmol, and the limit of quantification (LOQ) (S/N = 6:1) was 0.1 pmol for both PC 16:0/18:2-OOH and PC 18:0/18:2-OOH. Plasma concentrations of PC 16:0/18:2-OOH and PC 18:0/18:2-OOH were 89 and 32 nM, respectively, in a healthy volunteer.  相似文献   

6.
7.
Reproducible and comprehensive sample extraction and detection of metabolites with a broad range of physico-chemical properties from biological matrices can be a highly challenging process. A single LC/MS separation method was developed for a 2.1mmx100mm, 1.8mum ZORBAX SB-Aq column that was used to separate human erythrocyte metabolites extracted under sample extraction solvent conditions where the pH was neutral or had been adjusted to either, pH 2, 6 or 9. Internal standards were included and evaluated for tracking sample extraction efficiency. Through the combination of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) techniques in both positive (+) and negative (-) ion modes, a total of 2370 features (compounds and associated compound related components: isotopes, adducts and dimers) were detected across all pHs. Broader coverage of the detected metabolome was achieved by observing that (1) performing extractions at pH 2 and 9, leads to a combined 92% increase in detected features over pH 7 alone; and (2) including APCI in the analysis results in a 34% increase in detected features, across all pHs, than the total number detected by ESI. A significant dependency of extraction solvent pH on the recovery of heme and other compounds was observed in erythrocytes and underscores the need for a comprehensive sample extraction strategy and LC/MS analysis in metabolomics profiling experiments.  相似文献   

8.
Sensitive assay for determining plasma tenofovir concentrations by LC/MS/MS   总被引:1,自引:0,他引:1  
An LC/MS/MS assay for the determination of tenofovir (TNF) was developed and validated for use with the EDTA anticoagulated human plasma matrix. Heparin-treated plasma and serum matrices were also validated. After addition of adefovir as an internal standard, trifluoroacetic acid was used to produce a protein-free extract. Chromatographic separation was achieved with a Polar-RP Synergi, 2.0 mm x 150 mm, reversed-phase analytical column. The mobile phase was 3% acetonitrile/1% acetic acid, aq. Detection of TNF and the internal standard was achieved by ESI MS/MS in the positive ion mode using 288/176 and 274/162 transitions, respectively. The method was linear from 10 to 750 ng/ml with a minimum quantifiable limit of 10 ng/ml when 250 microl aliquots were analyzed. The usefulness of this LC/MS/MS method to routinely monitor plasma concentrations of TNF was demonstrated along with its ability to assist in the performance of pharmacokinetic studies.  相似文献   

9.
Purinergic Signalling - Purine metabolites have been implicated as clinically relevant biomarkers of worsening or improving Parkinson’s disease (PD) progression. However, the identification...  相似文献   

10.
We present a comprehensive, sensitive, and highly specific negative ion electrospray LC/MS method for identifying all structural classes of glucosinolates in crude plant extracts. The technique is based on the observation of simultaneous maxima in the abundances of the m/z 96 and 97 ions, generated by programmed cone voltage fragmentation, in the mass chromatogram. The abundance ratios lie in the range 1:2-1:4 ([m/z 96]/[m/z 97]). Examination of the corresponding full-scan mass spectra allows individual glucosinolates of all structural classes to be identified rapidly and with confidence. The use of linearly programmed cone voltage fragmentation enhances characteristic fragment ions without compromising the abundance of the analytically important [M - H]- ion and its associated (and analytically useful) sulfur isotope peaks. Detection limits are in the low nanogram range for full-scan, programmed cone voltage spectra. Comparison of the technique with LC/MS/MS methods (product ion, precursor ion, and constant neutral loss scans) has shown that the sensitivity and selectivity of the programmed cone voltage method is superior. Data obtained on a variety of plant extracts confirmed that the methodology was robust and reliable.  相似文献   

11.
12.
Determination of eprosartan in human plasma and urine by LC/MS/MS   总被引:1,自引:0,他引:1  
A protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of eprosartan in human plasma and urine. The solvent system also served as a protein precipitation reagent. The chromatographic separation was achieved on a CAPCELL PAK C18 column (50 mmx2.0 mm, 5 microm, Shiseido). A mobile phase was consisted of 0.5% formic acid in water and 0.5% formic acid in acetonitrile (72:28). Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API3000. The standard curves, which ranged from 5 to 2000 ng/mL in human plasma and from 0.25 to 50 microg/mL in urine, were fitted to a 1/x weighted quadratic regression model. The method proved to be accurate, specific and sensitive enough to be successfully applied to a pharmacokinetic study.  相似文献   

13.
An overview is presented of gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), the two major hyphenated techniques employed in metabolic profiling that complement direct 'fingerprinting' methods such as atmospheric pressure ionization (API) quadrupole time-of-flight MS, API Fourier transform MS, and NMR. In GC/MS, the analytes are normally derivatized prior to analysis in order to reduce their polarity and facilitate chromatographic separation. The electron ionization mass spectra obtained are reproducible and suitable for library matching, mass spectral collections being readily available. In LC/MS, derivatization and library matching are at an early stage of development and mini-reviews are provided. Chemical derivatization can dramatically increase the sensitivity and specificity of LC/MS methods for less polar compounds and provides additional structural information. The potential of derivatization for metabolic profiling in LC/MS is demonstrated by the enhanced analysis of plant extracts, including the potential to measure volatile acids such as formic acid, difficult to achieve by GC/MS. The important role of mass spectral library creation and usage in these techniques is discussed and illustrated by examples.  相似文献   

14.
Organophosphorus nerve agents (OPNA), chemically related to and derived from organophosphate insecticides, constitute a clear and present threat to both military and civilian targets. Military regimes and terrorist organizations have demonstrated the will and ability to produce mass casualties by dispersing organophosphorus nerve agents, which, in turn could terrorize populations and overwhelm healthcare systems. A high throughput, robust and sensitive analytical protocol has been developed for the quantitation of the urinary metabolites of sarin (GB), soman (GD), VX, Russian VX (RVX) and cyclohexylsarin (GF) utilizing solid phase extraction (SPE) followed by High Performance Liquid Chromatography (HPLC)-isotope dilution tandem mass spectrometry (LC/MS/MS). The method has demonstrated linearity and reproducibility (1-200 ng/mL) for all analytes and has a Limit of Quantitation (LOQ)< or =0.5 ng/mL for all analytes (S/N> or =10/1). The method was validated by performing 20 individual analyses over 10 days by five scientists with all values falling within two standard deviations of the mean.  相似文献   

15.
16.
目的:建立同时测定大鼠血浆中阿霉素和塞来昔布的液相色谱-串联质谱(LC/MS/MS)方法,研究这两种药物联合应用的药代动力学.方法:大鼠尾静脉注射阿霉素和塞来昔布,眼眶取血并抗凝,离心分离血浆,采用乙酸乙酯提取血浆中的阿霉素和塞来昔布,N2吹干乙酸乙酯,残留物用50μL甲醇溶解,取20μL用于LC/MS/MS分析.结果:用LC/MS/MS法检测大鼠血浆中阿霉素和塞来昔布的线性范围为1-800ng/mL,日内、日间精密度(RSD)均小于15%,检测血浆低、中、高三个浓度(8、50、500ng/mL)阿霉素的回收率分别为101.2%、95.1%和91.4%,检测血浆低、中、高三个浓度(8、50、500ng/mL)塞来昔布的回收率分别为105.6%、106.8%和93.7%.大鼠尾静脉注射5.8mg/kg阿霉素和3.8mg/kg塞来昔布的半衰期分别为2.3 h和3.6h,曲线下面积分别为670 ng·h·mL-1和1480ng·h·mL-1.结论:建立的方法灵敏、准确、快速,适甩于阿霉素和塞来昔布的药代动力学研究.  相似文献   

17.
Quaternary ammonium drugs (atracurium, bretylium, edrophonium, ipratropium, mivacurium, neostigmine, pancuronium and rocuronium) and herbicides (difenzoquat, diquat and paraquat) in human whole blood were analysed by LC/MS/MS with positive electrospray ionisation (ESI), following extraction with Bond Elut LRC-CBA cartridges. Internal standards were benzyldimethylphenylammonium chloride monohydrate and ethyl viologen for drug and herbicide analysis, respectively. Ion-pair chromatography used heptafluorobutyric acid (15 mM)-ammonium formate (20 mM) buffer adjusted to pH 3.30 with formic acid and a linear gradient from 5 to 90% methanol run over 18 min. Recoveries ranged from 79.7 to 105.1%, detection limits were between 3.6 and 20.4 ng/ml and the intra- and inter-day precisions were less than 18.6% at a concentration of 10 ng/ml. The method was applied to a case of accidental paraquat poisoning in which the concentration of paraquat in blood was 0.64 mg/l, which is within the range associated with fatal paraquat poisoning.  相似文献   

18.
The relationship between lipid status and metabolism, infant development and health has widely been studied, but the importance of individual glycerophospholipid species for biological functions in infants has hardly been considered. We developed a method for quantitative analyses of plasma glycerophospholipids from small sample volume. Proteins were precipitated with methanol, which eliminated further sample preparation. The supernatant was analysed by reversed-phase HPLC using a gradient of water, methanol and isopropanol as mobile phase. Electrospray ionisation in negative mode in combination with tandem mass spectrometry enabled detection of specific fatty acids as fragments of glycerophospholipid species. With this combination of chromatography and mass spectrometry, PC, lyso-PC, PE and lyso-PE species and their relevant isobaric compounds were quantified. Method validation showed a linear working range between 0.05 μmol/L and 10 μmol/L in diluted plasma samples. The intra-assay coefficients of variation (n=6) ranged from 1.1% to 13.9%. Results were comparable with data of the human metabolome database and gas chromatographic fatty acid analyses. All quantitatively important PE and PC species are covered. The method can be applied for investigating dietary effects on plasma GP composition from small plasma volumes.  相似文献   

19.
20.
As laboratories are called upon to develop novel, fast, and sensitive methods, here we present a completely automated method for the analysis of cocaine and its metabolites (benzoylecgonine, ecgonine methyl ester, ecgonine and cocaethylene) from whole blood. This method utilizes an online solid-phase extraction (SPE) with high performance liquid chromatographic separation and tandem mass spectrometric detection. Pretreatment of samples involve only protein precipitation and ultracentrifugation. An efficient online solid-phase extraction (SPE) procedure was developed using Hysphere MM anion sorbent. A gradient chromatography method with a Gemini C6-Phenyl (50mmx3.00mm i.d., 5microm) column was used for the complete separation of all components. Analysis was by positive ion mode electrospray ionization tandem mass spectrometry, using multiple reaction monitoring (MRM) to enhance the selectivity and sensitivity of the method. For the analysis, two MRM transitions are monitored for each analyte and one transition is monitored for each internal standard. With a 30-microL sample injection, linearity was analyte dependent but generally fell between 8 and 500ng/mL. The limits of detection (LODs) for the method ranged from 3 to 16ng/mL and the limits of quantitation (LOQs) ranged from 8 to 47ng/mL. The bias and precision were determined using a simple analysis of variance (ANOVA: single factor). The results demonstrate bias as <7%, and %precision as <9% for all components at each QC level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号