首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
通过测定阈值和频谱分析,比较了正常和卡那霉素中毒后豚鼠听觉脑干反应(ABR)及频率跟随反应(FFR)的特性.正常FFR的非线性随刺激频率的减低而增加,表现为高次谐波的出现.从频谱中基频成分的峰很容易识别FFR阈值.卡那霉素作用后,高频FFR首先受到影响,波幅下降,阈值显著升高.低频FFR受到影响较小.同一动物ABR阈值尚未变化时高频FFR的基频峰值已下降,乃至消失.实验结果表明FFR对耳毒性药物中毒反应由于其包含有频率特性比ABR更灵敏,更便于定量分析.  相似文献   

2.
The ABR wave forms of 16-day-old and adult Mongolian gerbils were evoked by click stimuli presented at rates ranging from 1 to 80/sec. Wave I and wave IV thresholds were determined for each of 5 click rates. Amplitudes and latencies of waves I and IV were measured at each of 7 click rates and 3 intensity levels (15, 40 and 65 dB above threshold). Thresholds for waves I and IV in the adult gerbil and wave I in the 16 day gerbil were unaffected by changes in stimulus repetition rate. Neonatal wave IV thresholds were unaffected by click rate for rates below 25/sec but increased approximately 7 dB/decade increase in click rate when rate exceeded 25/sec. Increasing click rate produced greater reductions in ABR amplitude among neonates than adults for both waves I and IV. Decreases in amplitude due to increasing rate were independent of intensity level in both neonatal and adult subjects. Increasing rate produced similar increases in wave I latency among 16 day and adult subjects, but produced much greater increases in wave IV latency among neonates. Stimulus intensity level and click rate acted independently on wave I and wave IV latency in adult subjects and wave I latency in neonates. However, an interaction between rate and intensity was observed with respect to neonatal wave IV latency.  相似文献   

3.
Primates depend on acoustic signals and cues to avoid predators, locate food, and share information. Accordingly, the structure and function of acoustic stimuli have long been emphasized in studies of primate behavioral and cognitive ecology. Yet, few studies have addressed how well primates hear such stimuli; indeed, the auditory thresholds of most primate species are unknown. This empirical void is due in part to the logistic and economic challenges attendant on traditional behavioral testing methods. Technological advances have produced a safe and cost‐effective alternative—the auditory brainstem response (ABR) method, which can be utilized in field conditions, on virtually any animal species, and without subject training. Here we used the ABR and four methods of threshold determination to construct audiograms for two strepsirrhine primates: the ring‐tailed lemur (Lemur catta) and slow loris (Nycticebus coucang). Next, to verify the general efficacy of the ABR method, we compared our results to published behaviorally‐derived audiograms. We found that the four ABR threshold detection methods produced similar results, including relatively elevated thresholds but similarly shaped audiograms compared to those derived behaviorally. The ABR and behavioral absolute thresholds were significantly correlated, and the frequencies of best sensitivity and high‐frequency limits were comparable. However, at frequencies ≤2 kHz, ABR thresholds were especially elevated, resulting in decreased agreement with behavioral thresholds and, in Lemur, the ABR 10‐dB range starting points were more than 2 octaves higher than the behavioral points. Finally, a comparison of ABR‐ and behaviorally‐derived audiograms from various animal taxa demonstrates the widespread efficacy of the ABR for estimating frequency of best sensitivity, but otherwise suggests caution; factors such as stimulus properties and threshold definition affect results. We conclude that the ABR method is a promising technique for estimating primate hearing sensitivity, but that additional data are required to explore its efficacy for estimating low‐frequency thresholds. Am. J. Primatol. 72:217–233, 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

4.
Effects of stimulus repetition rate on the slow and fast components of the auditory brain-stem response (ABR) were investigated in 10 adult subjects with normal hearing. The ABRs were recorded with click stimuli at repetition rates of 8, 13.3, 23.8, 40 and 90.9/sec and at an intensity level of 55 dB nHL. Power spectral analysis of the averaged responses was performed. Then the responses were divided into a slow component (0–400Hz) and a fast component (400–1500 Hz) by using digital filtering technique. The magnitude of the slow component was little affected with increasing stimulus rate from 8/sec to 90.9/sec, while successive waves of the fast component, including wave V, decreased in amplitude as stimulus rate was increased. The latency of the slow component and each wave of the fast component was prolonged with increasing click rates. The shift of latency became longer in the later waves than in the earlier waves.  相似文献   

5.
The influence of heat- and cold-induced pain on tactile sensitivity, a "touch gate", was measured under conditions in which the location of the noxious stimuli was varied with respect to the tactile stimulus applied to the thenar eminence of humans. Vibrotactile thresholds were measured in the absence of pain and during administration of a painful stimulus, with the stimulus frequencies selected to activate independently the four psychophysical channels hypothesized to exist in human glabrous skin. Heat-induced pain produced by spatially co-localizing the noxious stimuli with the tactile stimuli was found, on average, to elevate threshold amplitude by 2.2 times (6.7 dB). Co-localized, cold-induced pain raised the average thresholds by about 1.5 times (3.6 dB). Heat-induced pain presented contralaterally produced no change in vibrotactile sensitivity indicating that the effect is probably not due to attentional mechanisms. Ipsilateral heat-induced pain caused an elevation in tactile thresholds even when the noxious and non-noxious stimuli were not co-localized, and the effect may seem to require that the painful stimulus be within the somatosensory region defined possibly in terms of dermatomal organization. Thus the effect is probably related to somatotopic organization and is not peripherally mediated. A brief discussion as to the possible locus of the touch gate within the nervous system is also given.  相似文献   

6.
The influence of heat- and cold-induced pain on tactile sensitivity, a "touch gate", was measured under conditions in which the location of the noxious stimuli was varied with respect to the tactile stimulus applied to the thenar eminence of humans. Vibrotactile thresholds were measured in the absence of pain and during administration of a painful stimulus, with the stimulus frequencies selected to activate independently the four psychophysical channels hypothesized to exist in human glabrous skin. Heat-induced pain produced by spatially co-localizing the noxious stimuli with the tactile stimuli was found, on average, to elevate threshold amplitude by 2.2 times (6.7 dB). Co-localized, cold-induced pain raised the average thresholds by about 1.5 times (3.6 dB). Heat-induced pain presented contralaterally produced no change in vibrotactile sensitivity indicating that the effect is probably not due to attentional mechanisms. Ipsilateral heat-induced pain caused an elevation in tactile thresholds even when the noxious and non-noxious stimuli were not co-localized, and the effect may seem to require that the painful stimulus be within the somatosensory region defined possibly in terms of dermatomal organization. Thus the effect is probably related to somatotopic organization and is not peripherally mediated. A brief discussion as to the possible locus of the touch gate within the nervous system is also given.  相似文献   

7.
Three-channel Lissajous' trajectories (3-CLTs) of the cat auditory brain-stem response (ABR) were recorded using click stimuli ranging from 10 to 70 dB impulse SPL and were analyzed using planar analysis.The number of planar segments increased from typically 4 at 10 dB to 12 at 70 dB but certain shape features of the 3-CLT (apices) were preserved across stimulus levels. As stimulus level was raised, size of individual planar segments increased. There were progressive decreases in apex latency as stimulus level was increased. The combined durations of groups of high intensity planar segments were similar to those of their low intensity forms. Shape, size and orientation of planar segments tended to change more across stimulus intensities below 40 dB than above and appear to relate to the number of planar segments at any given stimulus level.These results suggest that changes in latency seem to be primarily cochlear in origin, whereas the origin of other observed changes is uncertain. The 3-CLT ABR is sensitive to intensity, especially below 40 dB, and can thus detect changes in auditory system function in response to changes in stimulus intensity, regardless of electrode position.  相似文献   

8.
The effects of glaucoma on binocular visual sensitivity for the detection of various stimulus attributes are investigated at the fovea and in four paracentral retinal regions. The study employed a number of visual stimuli designed to isolate the processing of various stimulus attributes. We measured absolute contrast detection thresholds and functional contrast sensitivity by using Landolt ring stimuli. This psychophysical Landolt C-based contrast test of detection and gap discrimination allowed us to test parafoveally at 6 ° from fixation and foveally by employing interleaved testing locations. First-order motion perception was examined by using moving stimuli embedded in static luminance contrast noise. Red/green (RG) and yellow/blue (YB) colour thresholds were measured with the Colour Assessment and Diagnosis (CAD) test, which utilises random dynamic luminance contrast noise (± 45 %) to ensure that only colour and not luminance signals are available for target detection. Subjects were normal controls (n?=?65) and glaucoma patients with binocular visual field defects (n?=?15) classified based on their Humphrey Field Analyzer mean deviation (MD) scores. The impairment of visual function varied depending on the stimulus attribute and location tested. Progression of loss was noted for all tests as the degree of glaucoma increased. For subjects with mild glaucoma (MD ?0.01 dB to ?6.00 dB) significantly more data points fell outside the normal age-representative range for RG colour thresholds than for any other visual test, followed by motion thresholds. This was particularly the case for the parafoveal data compared with the foveal data. Thus, a multifaceted measure of binocular visual performance, incorporating RG colour and motion test at multiple locations, might provide a better index for comparison with quality of life measures in glaucoma.  相似文献   

9.
It has not been established whether the smallest perceptible change in the intensity of vibrotactile stimuli depends on the somatosensory channel mediating the sensation. This study investigated intensity difference thresholds for vibration using contact conditions (different frequencies, magnitudes, contact areas, body locations) selected so that perception would be mediated by more than one psychophysical channel. It was hypothesized that difference thresholds mediated by the non-Pacinian I (NPI) channel and the Pacinian (P) channel would differ. Using two different contactors (1-mm diameter contactor with 1-mm gap to a fixed surround; 10-mm diameter contactor with 2-mm gap to the surround) vibration was applied to the thenar eminence and the volar forearm at two frequencies (10 and 125?Hz). The up-down-transformed-response method with a three-down-one-up rule provided absolute thresholds and also difference thresholds at various levels above the absolute thresholds of 12 subjects (i.e., sensation levels, SLs) selected to activate preferentially either single channels or multiple channels. Median difference thresholds varied from 0.20 (thenar eminence with 125-Hz vibration at 10?dB SL) to 0.58 (thenar eminence with 10-Hz vibration at 20?dB SL). Median difference thresholds tended to be lower for the P channel than the NPI channel. The NPII channel may have reduced difference thresholds with the smaller contactor at 125?Hz. It is concluded that there are large and systematic variations in difference thresholds associated with the frequency, the magnitude, the area of contact, and the location of contact with vibrotactile stimuli that cannot be explained without increased understanding of the perception of supra-threshold vibrotactile stimuli.  相似文献   

10.
Although tactile spatial acuity tests are used in both neuroscience research and clinical assessment, few automated devices exist for delivering controlled spatially structured stimuli to the skin. Consequently, investigators often apply tactile stimuli manually. Manual stimulus application is time consuming, requires great care and concentration on the part of the investigator, and leaves many stimulus parameters uncontrolled. We describe here a computer-controlled tactile stimulus system, the Tactile Automated Passive-finger Stimulator (TAPS), that applies spatially structured stimuli to the skin, controlling for onset velocity, contact force, and contact duration. TAPS is a versatile, programmable system, capable of efficiently conducting a variety of psychophysical procedures. We describe the components of TAPS, and show how TAPS is used to administer a two-interval forced-choice tactile grating orientation test.Corresponding Author: Daniel Goldreich  相似文献   

11.
Auditory event-related potentials (ERPs) were assessed in young and elderly subjects when stimulus intensity (40 vs. 60 dB SL) and standard/target tone frequency (250/500 Hz and 1000/2000 Hz) were manipulated to study the effects of these variables on the P3(00) and N1, P2 and N2 components. Auditory thresholds for each stimulus type were obtained, and the stimulus intensity was adjusted to effect perceptually equal intensities across conditions for each subject. Younger subjects demonstrated larger P3 amplitudes and shorter latencies than elderly subjects. The low frequency stimuli produced larger P3 amplitude and shorter latencies than the high frequency stimuli. Low intensity stimuli yielded somewhat smaller P3 amplitudes and longer peak latencies than high intensity stimulus tones. Although additional stimulus intensity and frequency effects were obtained for the N1, P2 and N2 components, these generally differed relatively little with subject age. The findings suggest that auditory stimulus parameters contribute to P3 measures, which are different for young compared to elderly subjects.  相似文献   

12.
The firing-rate-based population model for rapidly-adapting (RA) mechanoreceptive fibers by Güçlü and Bolanowski (Güçlü B, Bolanowski SJ. 2002. Modeling population responses of rapidly-adapting mechanoreceptive fibers. Journal of Computational Neuroscience 12:201–218.) is extended by including temporal-response properties of RA fibers. This representation allows for the generation of action-potential (spike) times for each fiber when a sinusoidal, steady-state stimulus is applied onto the skin. Signal detection theory was used to predict human psychophysical thresholds. Specifically, the effects of sensorineural innervation pattern, stimulus-contactor location and selected decision rules on the model predictions were studied. The predicted thresholds were lowest when the decision rule was one spike and highest when many active fibers were required for detection. These predictions were empirically tested by measuring vibrotactile thresholds of the Non-Pacinian I (NP I) channel, which required the special techniques discussed in the preceding article. Although the model predicted thresholds to decrease distally due to the known innervation density which is higher distally, the thresholds of the NP I psychophysical channel were found to be approximately constant (20–25?dB re 1?µm peak amplitude) from the proximal site on the terminal phalanx to the most distal portion. Interestingly, the mechanical impedance of the skin was found not to be constant along the proximo-distal axis. This latter result implies that the space-invariant mechanical attenuation function used in the model may not be valid at every location on the fingertip. Because of this, the discrepancy between the model's predictions and the psychophysical results may be reconciled.  相似文献   

13.
Perception of cutaneous heating and cooling depends strongly on stimulus size. Although this dependence has been attributed solely to spatial summation, topographical variations in temperature sensitivity may also play a role. These variations, which differentially affect perception of small stimuli, may have led to overestimation of spatial summation. This possibility was investigated by measuring detection thresholds and perceived intensity for heating and cooling on the volar surface of the forearm using a multiple-thermode stimulus array. By keeping the array in place throughout each testing session we were able to measure threshold sensitivity and suprathreshold responsiveness at eight individual sites and for combinations of these sites having total stimulus areas of 0.64-5.12 cm2. When spatial summation was calculated in the traditional way by averaging the data for all stimuli of each size, the results agreed closely with previous estimates of summation for warmth and cold. When calculations were based instead on the most sensitive test site for each stimulus size, estimates of summation were reduced by about two-thirds. This outcome indicates that the spatial heterogeneity of thermal sensitivity likely contributed to estimates of spatial summation reported in earlier psychophysical studies. A schematic model of cutaneous thermoreception is presented that shows how neural summation and the density of innervation may combine to produce the psychophysical effects of increasing stimulus size (spatial enhancement).  相似文献   

14.
Psychophysical thresholds for the detection of a 300-Hz burst of vibration applied to the thenar eminence were measured for stimuli applied to the skin through 1.5 cm2 and through 0.05 cm2 contactors. Thresholds were approximately 13 dB lower when the area of the contactor was 1.5 cm2 than when it was 0.05 cm2. The difference between the thresholds measured with the large and small contactors was significantly reduced when only the lowest thresholds obtained in the testing sessions were considered. This result supports the hypothesis that one component of spatial summation in the P channel is probability summation. In addition, threshold measurements within a session were less variable when measured with the 1.5 cm2 contactor. We conclude that spatial summation in the P channel is a joint function of two processes that occur as the areal extent of the stimulus increases: probability summation in which the probability of exceeding the psychophysical detection threshold increases as the number of receptors of varying sensitivities increases, and neural integration in which neural activity originating from separate receptors is combined within the central nervous system rendering the channel more sensitive to the stimulus.  相似文献   

15.
Responses to vibrotactile stimuli were examined in men as a function of chronic exposure to either exogenous or endogenous androgens. Psychophysical techniques were used to evaluate thresholds to stimulus detection and perceived stimulus intensities in response to mild vibration applied to either the finger or the penis. Normal men were compared to the following groups: (a) untreated hypogonadal men, (b) androgen-replaced hypogonadal men, or (c) infertile men with androgen levels in the low normal range. Among the four groups, untreated hypogonadal men perceived vibrotactile stimuli as most intense and were slightly more sensitive to touch than were men with higher levels of androgen. Chronic treatment with testosterone enanthate was associated with a decline in the perceived intensity of vibrotactile stimuli in hypogonadal men. The lowest levels of sensitivity to tactile stimuli were observed in the infertile men.  相似文献   

16.
An adaptive psychophysical procedure was used to estimate the vibration detection threshold at seven spatially matched sites on the two sides of the face and at one scalp site. Repeated measurements over six testing sessions were made for stimuli vibrating at 1, 10 and 100 Hz for each of 21 neurologically healthy, young adult females. Approximately 14 stimulus trials were required to obtain each estimate of the threshold amplitude. Thresholds varied as a function of frequency ( p < 0.0001), side ( p < 0.001) and site ( p < 0.0001). Compared to stimulation at 100 Hz at which the estimates were lowest, thresholds were 3.1 times greater at 10 Hz and 5.4 times greater at 1 Hz. Thresholds were lowest on the vermilion and highest on the cheek and chin. The preauricular skin and scalp exhibited an intermediate level of sensitivity. Whereas thresholds were comparable on the two sides of the face for stimulation at 1 Hz, they averaged 1.33 times greater on the right side for stimulation at 10 and 100 Hz. Moreover, thresholds obtained during the last two sessions were 16% higher than those obtained during the first two sessions ( p < 0.02), suggesting that subjects on average became more conservative in reporting the presence of the stimulus. The sensitivity in discriminating differences in tactile function favors use of the rapidly administered testing procedure in a clinical setting.  相似文献   

17.
An adaptive psychophysical procedure was used to estimate the vibration detection threshold at seven spatially matched sites on the two sides of the face and at one scalp site. Repeated measurements over six testing sessions were made for stimuli vibrating at 1, 10 and 100 Hz for each of 21 neurologically healthy, young adult females. Approximately 14 stimulus trials were required to obtain each estimate of the threshold amplitude. Thresholds varied as a function of frequency (p < 0.0001), side (p < 0.001) and site (p < 0.0001). Compared to stimulation at 100 Hz at which the estimates were lowest, thresholds were 3.1 times greater at 10 Hz and 5.4 times greater at 1 Hz. Thresholds were lowest on the vermilion and highest on the cheek and chin. The preauricular skin and scalp exhibited an intermediate level of sensitivity. Whereas thresholds were comparable on the two sides of the face for stimulation at 1 Hz, they averaged 1.33 times greater on the right side for stimulation at 10 and 100Hz. Moreover, thresholds obtained during the last two sessions were 16% higher than those obtained during the first two sessions (p < 0.02), suggesting that subjects on average became more conservative in reporting the presence of the stimulus. The sensitivity in discriminating differences in tactile function favors use of the rapidly administered testing procedure in a clinical setting.  相似文献   

18.
The firing-rate-based population model for rapidly-adapting (RA) mechanoreceptive fibers by Gü?lü and Bolanowski is extended by including temporal-response properties of RA fibers. This representation allows for the generation of action-potential (spike) times for each fiber when a sinusoidal, steady-state stimulus is applied onto the skin. Signal detection theory was used to predict human psychophysical thresholds. Specifically, the effects of sensorineural innervation pattern, stimulus-contactor location and selected decision rules on the model predictions were studied. The predicted thresholds were lowest when the decision rule was one spike and highest when many active fibers were required for detection. These predictions were empirically tested by measuring vibrotactile thresholds of the Non-Pacinian I (NP I) channel, which required the special techniques discussed in the preceding article. Although the model predicted thresholds to decrease distally due to the known innervation density which is higher distally, the thresholds of the NP I psychophysical channel were found to be approximately constant (20-25 dB re 1 microm peak amplitude) from the proximal site on the terminal phalanx to the most distal portion. Interestingly, the mechanical impedance of the skin was found not to be constant along the proximo-distal axis. This latter result implies that the space-invariant mechanical attenuation function used in the model may not be valid at every location on the fingertip. Because of this, the discrepancy between the model's predictions and the psychophysical results may be reconciled.  相似文献   

19.
This study was designed to identify psychophysical channels responsible for the detection of hand-transmitted vibration. Perception thresholds for vibration (16, 31.5, 63 and 125 Hz sinusoidal for 600 ms) at the distal phalanx of the middle finger and the whole hand were determined with and without simultaneous masking stimuli (1/3 octave bandwidth Gaussian random vibration centered on either 16 Hz or 125 Hz for 3000 ms, varying in magnitude 0 to 30 dB above threshold). At all frequencies from 16 to 125 Hz, absolute thresholds for the hand were significantly lower than those for the finger. Changes in threshold as a function of masker level were used to estimate the thresholds of three psychophysical channels (i.e. P, NP I, and NP II channels). Increased vibrotactile sensitivity of the hand compared to the finger seems to be not entirely due to increased spatial summation via the Pacinian system (P channel); non-Pacinian system (NP I and NP II channels) also contributed to perception. Differing transmission of vibration between the hand and the finger may have also influenced the thresholds.  相似文献   

20.
This study was designed to identify psychophysical channels responsible for the detection of hand-transmitted vibration. Perception thresholds for vibration (16, 31.5, 63 and 125?Hz sinusoidal for 600?ms) at the distal phalanx of the middle finger and the whole hand were determined with and without simultaneous masking stimuli (1/3 octave bandwidth Gaussian random vibration centered on either 16?Hz or 125?Hz for 3000?ms, varying in magnitude 0 to 30?dB above threshold). At all frequencies from 16 to 125?Hz, absolute thresholds for the hand were significantly lower than those for the finger. Changes in threshold as a function of masker level were used to estimate the thresholds of three psychophysical channels (i.e. P, NP I, and NP II channels). Increased vibrotactile sensitivity of the hand compared to the finger seems to be not entirely due to increased spatial summation via the Pacinian system (P channel); non-Pacinian system (NP I and NP II channels) also contributed to perception. Differing transmission of vibration between the hand and the finger may have also influenced the thresholds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号