首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The development of new high throughput methods based on different materials with chemical modifications for protein profiling of complex mixtures leads towards biomarkers; used particularly for early diagnosis of a disease. In this work, diamond-like carbon (DLC) is developed and optimized for serum protein profiling by matrix-assisted laser/desorption ionization mass spectrometry (MALDI-MS). This study is carried out in connection with a material-based approach, termed as material-enhanced laser desorption ionization mass spectrometry. DLC is selected as carrier surface which provides large surface to volume ratio and offers high sensitivity. DLC has a dual role of working as MALDI target while acting as an interface for protein profiling by specifically binding peptides and proteins out of serum samples. Serum constituents are bound through immobilized metal ion affinity chromatography (IMAC) functionality, created through glycidyl methacrylate polymerization under ultraviolet light followed by further derivatization with iminodiacetic acid and copper ion loading. Scanning electron microscopy highlights the morphological characteristics of DLC surface. It could be demonstrated that IMAC functionalized DLC coatings represent a powerful material in trapping biomolecules for their further analysis by MALDI-MS resulting in improved sensitivity, specificity and capacity in comparison to other protein-profiling methods.  相似文献   

2.
Functional protein microarrays   总被引:3,自引:0,他引:3  
Microarrays of immobilized functional proteins have the potential to increase dramatically the throughput of proteomic analysis. Micro-immunoassays, in which biological samples are exposed to arrays of immobilized antibodies, can be used for protein expression profiling. In addition, protein function can be elucidated by performing binding and enzymatic assays on arrays of biologically active proteins.  相似文献   

3.
Characterization of the extracellular protein interactome has lagged far behind that of intracellular proteins, where mass spectrometry and yeast two-hybrid technologies have excelled. Improved methods for identifying receptor-ligand and extracellular matrix protein interactions will greatly accelerate biological discovery in cell signaling and cellular communication. These technologies must be able to identify low-affinity binding events that are often observed between membrane-bound coreceptor molecules during cell-cell or cell-extracellular matrix contact. Here we demonstrate that functional protein microarrays are particularly well-suited for high-throughput screening of extracellular protein interactions. To evaluate the performance of the platform, we screened a set of 89 immunoglobulin (Ig)-type receptors against a highly diverse extracellular protein microarray with 686 genes represented. To enhance detection of low-affinity interactions, we developed a rapid method to assemble bait Fc fusion proteins into multivalent complexes using protein A microbeads. Based on these screens, we developed a statistical methodology for hit calling and identification of nonspecific interactions on protein microarrays. We found that the Ig receptor interactions identified using our methodology are highly specific and display minimal off-target binding, resulting in a 70% true-positive to false-positive hit ratio. We anticipate that these methods will be useful for a wide variety of functional protein microarray users.  相似文献   

4.
Nonspecific interactions between immobilized biomolecules and interfering proteins significantly impede biosensor development and commercialization. Advances in bioinformatics and computer technology have facilitated a greater understanding of biological interactions. We employed two different protein–protein docking programs to simulate the nonspecific interaction between ampicillin antibody and potential interfering proteins (human serum albumin and ovalbumin). To evaluate the contact and probability of association with the active site of the antibody, different amino acid chains from human serum albumin (HSA) and ovalbumin (OVA) were modeled in the simulation. In addition, a well-known specific immune complex, lysozyme and lysozyme antibody, was simulated for comparison. The results demonstrated that the cluster density of nonspecific interactions was smaller than the specific interaction between lysozyme and antibody, and that the dock scores were scattered. However, the active site of ampicillin antibody was prone to nonspecific protein interactions. The strength of interaction was different for specific binding and nonspecific binding. These results provide a platform for detecting the probability of nonspecific interactions and for improving methods of biosensor detection construction with reduced nonspecific adsorption.  相似文献   

5.
Echan LA  Tang HY  Ali-Khan N  Lee K  Speicher DW 《Proteomics》2005,5(13):3292-3303
Systematic detection of low-abundance proteins in human blood that may be putative disease biomarkers is complicated by an extremely wide range of protein abundances. Hence, depletion of major proteins is one potential strategy for enhancing detection sensitivity in serum or plasma. This study compared a recently commercialized HPLC column containing antibodies to six of the most abundant blood proteins ("Top-6 depletion") with either older Cibacron blue/Protein A or G depletion methods or no depletion. In addition, a prototype spin column version of the HPLC column and an alternative prototype two antibody spin column were evaluated. The HPLC polyclonal antibody column and its spin column version are very promising methods for substantially simplifying human serum or plasma samples. These columns show the lowest nonspecific binding of the depletion methods tested. In contrast other affinity methods, particularly dye-based resins, yielded many proteins in the bound fractions in addition to the targeted proteins. Depletion of six abundant proteins removed about 85% of the total protein from human serum or plasma, and this enabled 10- to 20-fold higher amounts of depleted serum or plasma samples to be applied to 2-D gels or alternative protein profiling methods such as protein array pixelation. However, the number of new spots detected on 2-D gels was modest, and most newly visualized spots were minor forms of relatively abundant proteins. The inability to detect low-abundance proteins near expected 2-D staining limits was probably due to both the highly heterogeneous nature of most plasma or serum proteins and masking of many low-abundance proteins by the next series of most abundant proteins. Hence, non2-D methods such as protein array pixelation are more promising strategies for detecting lower abundance proteins after depleting the six abundant proteins.  相似文献   

6.
Recent advances in -omic profiling technologies have ushered in an era where we no longer want to merely measure the presence or absence of a biomolecule of interest, but instead hope to understand its function and interactions within larger signaling networks. Here, we review several emerging proteomic technologies capable of detecting protein interaction networks in live cells and their integration to draft holistic maps of proteins that respond to diverse stimuli, including bioactive small molecules. Moreover, we provide a conceptual framework to combine so-called ‘top-down’ and ‘bottom-up’ interaction profiling methods and ensuing proteomic profiles to directly identify binding targets of small molecule ligands, as well as for unbiased discovery of proteins and pathways that may be directly bound or influenced by those first responders. The integrated, interaction-based profiling methods discussed here have the potential to provide a unique and dynamic view into cellular signaling networks for both basic and translational biological studies.  相似文献   

7.
Complementary metal oxide semiconductor (CMOS) microelectronic chips fulfill important functions in the field of biomedical research, ranging from the generation of high complexity DNA and protein arrays to the detection of specific interactions thereupon. Nevertheless, the issue of merging pure CMOS technology with a chemically stable surface modification which further resists interfering nonspecific protein adsorption has not been addressed yet. We present a novel surface coating for CMOS microchips based on poly(ethylene glycol)methacrylate graft polymer films, which in addition provides high loadings of functional groups for the linkage of probe molecules. The coated microchips were compatible with the harshest conditions emerging in microarray generating methods, thoroughly retaining structural integrity and microelectronic functionality. Nonspecific adsorption of proteins on the chip's surface was completely obviated even with complex serum protein mixtures. We could demonstrate the background-free antibody staining of immobilized probe molecules without using any blocking agents, encouraging further integration of CMOS technology in proteome research.  相似文献   

8.
A procedure has been developed for protein identification using mass spectrometry (MS) that incorporates sample cleanup, preconcentration, and protein digestion in a single-stage system. The procedure involves the adsorption of a protein, or protein mixture, from solution onto a hydrophobic resin that is contained within a microcolumn. Sample loading is accomplished by flowing the protein solution through the microcolumn, where the protein adsorbs to the hydrophobic surface. The protein is digested while still bound to the hydrophobic surface by flowing a buffered trypsin solution through the column bed. The peptide fragments are subsequently eluted for detection by MALDI or ESI-MS. The procedure is demonstrated using dilute protein samples containing high concentrations of salt, urea, and modest amount of sodium dodecyl sulfate relative to protein. Peptide fragments are also detected by MS from a 500 nM bacteriorhodopsin solution digested in a microcolumn. In this case, a combined cyanogen bromide/trypsin digestion was performed in-column. The procedure is applied to the MALDI-MS/MS identification of proteins present in an individual fraction collected by ion exchange HPLC separation of E. coli total cell extract. An additional application is illustrated in the analysis of a human plasma fraction. A total of 14 proteins, which were present in the sample at sub-micromolar concentrations, were identified from ESI-MS/MS. The microcolumn digestion procedure represents the next step toward a system for fully automated protein analysis through capture and digestion of the adsorbed protein on hydrophobic surfaces.  相似文献   

9.
Biological regulatory systems require the specific organization of proteins into multicomponent complexes. Two hybrid systems have been used to identify novel components of signaling networks based on interactions with defined partner proteins. An important issue in the use of two-hybrid systems has been the degree to which interacting proteins distinguish their biological partner from evolutionarily conserved related proteins and the degree to which observed interactions are specific. We adapted the basic two-hybrid strategy to create a novel dual bait system designed to allow single-step screening of libraries for proteins that interact with protein 1 of interest, fused to DNA binding domain A (LexA), but do not interact with protein 2, fused to DNA binding domain B (lambda cI). Using the selective interactions of Ras and Krev-1(Rap1A) with Raf, RalGDS, and Krit1 as a model, we systematically compared LexA- and cI-fused baits and reporters. The LexA and cI baitr reporter systems are well matched for level of bait expression and sensitivity range for interaction detection and allow effective isolation of specifically interacting protein pairs against a nonspecific background. These reagents should prove useful to refine the selectivity of library screens, to reduce the isolation of false positives in such screens, and to perform directed analyses of sequence elements governing the interaction of a single protein with multiple partners.  相似文献   

10.
The low molecular weight plasma proteome and its biological relevance are not well defined; therefore, experiments were conducted to directly sequence and identify peptides observed in plasma and serum protein profiles. Protein fractionation, matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) profiling, and liquid-chromatography coupled to MALDI tandem mass spectrometry (MS/MS) sequencing were used to analyze the low molecular weight proteome of heparinized plasma. Four fractionation techniques using functionally derivatized 96-well plates were used to extract peptides from plasma. Tandem TOF was successful for identifying peptides up to m/z 5500 with no prior knowledge of the sequence and was also used to verify the sequence assignments for larger ion signals. The peptides (n>250) sequenced in these profiles came from a surprisingly small number of proteins (n approximately 20), which were all common to plasma, including fibrinogen, complement components, antiproteases, and carrier proteins. The cleavage patterns were consistent with those of known plasma proteases, including initial cleavages by thrombin, plasmin and complement proteins, followed by aminopeptidase and carboxypeptidase activity. On the basis of these data, we discuss limitations in biomarker discovery in the low molecular weight plasma or serum proteome using crude fractionation coupled to MALDI-MS profiling.  相似文献   

11.
Protein microchips: use for immunoassay and enzymatic reactions   总被引:34,自引:0,他引:34  
Different proteins such as antibodies, antigens, and enzymes were immobilized within the 100 x 100 x 20-microm gel pads of protein microchips. A modified polyacrylamide gel has been developed to accommodate proteins of a size up to 400,000 daltons. Electrophoresis in the microchip reaction chamber speeded up antigen-antibody interactions within the gel. Protein microchips were used in immunoassays for detection of antigens or antibodies, as well as to carry out enzymatic reactions and to measure their kinetics in the absence or presence of an inhibitor. A protein microchip can be used several times in different immunoassays and enzymatic kinetic measurements.  相似文献   

12.
The detection of biomarkers in biological fluids has been advanced by the introduction of mass spectrometry screening methods such as matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS), which enables the detection of the presence and the molecular mass of proteins in unfractionated mixtures. The generation of reproducible mass spectra over the course of an experiment is vital in obtaining data in which differences in protein profiles between diseased and healthy states can be assessed correctly. We have developed a protocol to automate the collection of protein profiling data from a large number of samples using MALDI-TOFMS, and we used these samples to characterize the technical reproducibility of the method. This protocol has been used for the analysis of proteins found in bronchoalveolar lavage fluid samples from mice with the ultimate goal of enabling the discovery of differential expression patterns predictive of the development of chronic obstructive pulmonary disease. Samples were purified using magnetic bead-based technology and analyzed on an AnchorChip target plate. Our results demonstrate that the number of peaks detected reproducibly decreases significantly as sample size increases, which motivates the need for technical replicates to be explicitly included in the analysis of MALDI-TOF-based protein profiling studies.  相似文献   

13.
The budding yeast Saccharomyces cerevisiae is a major model organism for important biological processes such as mitotic growth and meiotic development, it can be a human pathogen, and it is widely used in the food-, and biotechnology industries. Consequently, the genomes of numerous strains have been sequenced and a very large amount of RNA profiling data is available. Moreover, it has recently become possible to quantitatively analyze the entire yeast proteome; however, efficient and cost-effective high-throughput protein profiling remains a challenge. We report here a new approach to direct and label-free large-scale yeast protein identification using a tandem buffer system for protein extraction, two-step protein prefractionation and enzymatic digestion, and detection of peptides by iterative mass spectrometry. Our profiling study of diploid cells undergoing rapid mitotic growth identified 86% of the known proteins and its output was found to be widely concordant with genome-wide mRNA concentrations and DNA variations between yeast strains. This paves the way for comprehensive and straightforward yeast proteome profiling across a wide variety of experimental conditions.  相似文献   

14.
Complexes formation between two model proteins (catalase and chymotrypsin) and polyelectrolytes (polyvinyl sulphonate and polyacrilic acid) and a non-charged flexible chain polymer (PCF) as polyethylene propylene oxide (molecular mass 8400) was studied by a spectroscopy technique combination: UV absorption, fluorescence emission and circular dichroism. All the polymers increase the protein surface hydrophobicity (S(0)) parameter value as a proof of the modification of the protein surface exposed to the solvent. Chymotrypsin showed an increase in its biological activity in polymer presence, which suggests a change in the superficial microenvironment. The decrease in the biological activity of catalase might be due to a competition between the polymer and the substrate. This result agrees with the polymer effect on the catalase superficial hydrophobic area. It was found that, when flexible chain polymers increase protein stability and the enzymatic activity they could be used to isolate this enzyme without inducing loss of protein enzymatic activity. Our findings suggest that the interactions are dependent on the protein physico-chemical parameters such as: isoelectric pH, hydrophobic surface area, etc.  相似文献   

15.
The simian virus 40 A protein (T antigen) recognized and bound to the consensus sequence 5'-GAGGC-3' in DNA from many sources. Sequence-specific binding to single pentanucleotides in randomly chosen DNA predominated over binding to nonspecific sequences. The asymmetric orientation of protein bound to nonorigin recognition sequences also resembled that of protein bound to the origin region of simian virus 40 DNA. Sequence variations in the DNA adjacent to single pentanucleotides influenced binding affinities even though methylation interference and protection studies did not reveal specific interactions outside of pentanucleotides. Thus, potential locations of A protein bound to any DNA can be predicted although the determinants of binding affinity are not yet understood. Sequence-specific binding of A protein to cellular DNA would provide a mechanism for specific alterations of host gene expression that facilitate viral function.  相似文献   

16.
We have developed a new target plate for matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). This target plate enables direct electric transfer of analytes from the 1-dimensional gel electrophoresis (1-DE) gel to the target plate in one step. Incorporated with a one-step direct transfer technique, this novel 1-DE/MALDI-MS (1-DE/MS) system eliminates staining, extracting, loading, and many other time-consuming intermediate processes, thereby greatly reducing analysis time while providing high throughput proteome analysis. Furthermore, in peptidome analysis, during the 1-DE step this system separates or removes the high molecular weight plasma proteins in blood and the various low molecular weight substances in tissue extracts, which interfere with mass spectrometry. This system can therefore be used for peptide profiling of any biological sample without special pretreatment. In view of these advantages, the 1-DE/MS system will greatly improve the usefulness of current peptidomic modalities in the discovery and validation of biomarker molecules in various body fluids and tissue extracts, permitting early detection, diagnosis, and treatment of diseases.  相似文献   

17.
M Sanzo  B Stevens  M J Tsai  B W O'Malley 《Biochemistry》1984,23(26):6491-6498
We have fractionated oviduct tissue extracts by using a combination of ion-exchange and DNA-Sephadex chromatography. By comparing the electrophoretic patterns of proteins eluted from competing specific and nonspecific DNA columns, we isolated a fraction which bound with specificity to columns containing the chicken middle repetitive sequence "CR1". This fraction showed a clear preference for binding to separate, cloned CR1 fragments derived from either the 5' or the 3' transition region of the ovalbumin gene domain when examined by using nitrocellulose filter binding assays. To localize the protein binding site, a CR1 clone was digested with various restriction enzymes, and the resulting fragments were examined for preferential protein binding. Results suggest that the binding site lies within a 39-nucleotide sequence which is highly conserved among different CR1 elements. This finding represents the first isolation of a protein which demonstrates a preference for binding to a middle repetitive sequence and suggests that this interaction may have a biological role. The DNA column competition adsorption method should have general application to the isolation of other gene-regulating proteins possessing DNA sequence preference.  相似文献   

18.
This report describes the development of a method to detect the waterborne pathogen Aeromonas using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The genus Aeromonas is one of several medically significant genera that have gained prominence due to their evolving taxonomy and controversial role in human diseases. In this study, MALDI-MS was applied to the characterization of seventeen species of Aeromonas. These seventeen species were represented by thirty-two strains, which included type, reference and clinical isolates. Intact cells from each strain were used to generate a reproducible library of protein mass spectral fingerprints or m/z signatures. Under the test conditions used, peak lists of the mass ions observed in each species revealed that three mass ions were conserved among all the seventeen species tested. These common mass ions having an average m/z of 6301, 12,160 or 12,254, and 13,450, can be potentially used as genus-specific biomarkers to identify Aeromonas in unknown samples. A dendrogram generated using the m/z signatures of all the strains tested indicated that the mass spectral data contained sufficient information to distinguish between genera, species, and strains. There are several advantages of using MALDI-MS based protein mass spectral fingerprinting of whole cells for the identification of microorganisms as well as for their differentiation at the sub-species level: (1) the capability to detect proteins, (2) high throughput, and (3) relatively simple sample preparation techniques. The accuracy and speed with which data can be obtained makes MALDI-MS a powerful tool especially suited for environmental monitoring and detection of biological hazards.  相似文献   

19.
Protein precipitation is one of the most widely used methods for antigen detection and purification in biological research. We developed a reproducible aptamer-mediated magnetic protein precipitation method that is able to efficiently capture, purify and isolate the target proteins. We discovered DNA aptamers having individually high affinity and specificity against human epidermal growth factor receptor (EGFR) and human insulin receptor (INSR). Using aptamers and magnetic beads, we showed it is highly efficient technique to enrich endogenous proteins complex and is applicable to identify physiologically relevant protein–protein interactions with minimized nonspecific binding of proteins. The results presented here indicate that aptamers would be applicable as a useful and cost-effective tool to identify the presence of the particular target protein with their specific protein partners.  相似文献   

20.
A new method is described for isolating and identifying proteins participating in protein-protein interactions in a complex mixture. The method uses a cyanogen bromide-activated Sepharose matrix to isolate proteins that are non-covalently bound to other proteins. Because the proteins are accessible to chemical manipulation, mass spectrometric identification of the proteins can yield information on specific classes of interacting proteins, such as calcium-dependent or substrate-dependent protein interactions. This permits selection of a subpopulation of proteins from a complex mixture on the basis of specified interaction criteria. The new method has the advantage of screening the entire proteome simultaneously, unlike the two-hybrid system or phage display, which can only detect proteins binding to a single bait protein at a time. The method was tested by selecting rat brain extract for proteins exhibiting calcium-dependent protein interactions. Of 12 proteins identified by mass spectrometry, eight were either known calcium-binding proteins or proteins with known calcium-dependent protein interactions, indicating that the method is capable of enriching a subpopulation of proteins from a complex mixture on the basis of a specific class of protein interactions. Because only naturally occurring interactions of proteins in their native state are observed, this method will have wide applicability to studies of protein interactions in tissue samples and autopsy specimens, for screening for perturbations of protein-protein interactions by signaling molecules, pharmacological agents or toxins, and screening for differences between cancerous and untransformed cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号