首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A quartz crystal microbalance (QCM) DNA sensor, based on the nanoparticle amplification method, was developed for detection of Escherichia coli O157:H7. A thiolated single-stranded DNA (ssDNA) probe specific to E. coli O157:H7 eaeA gene was immobilized onto the QCM sensor surface through self-assembly. The hybridization was induced by exposing the ssDNA probe to the complementary target DNA, and resulted in the mass change and therefore frequency change of the QCM. Streptavidin conjugated Fe(3)O(4) nanoparticles (average diameter=145 nm) were used as "mass enhancers" to amplify the frequency change. Synthesized biotinylated oligonucleotides as well as E. coli O157:H7 eaeA gene fragments (151 bases) amplified using asymmetric PCR with biotin labeled primers were tested. As low as 10(-12)M synthesized oligonucleotides and 2.67 x 10(2) colony forming unit (CFU)/ml E. coli O157:H7 cells can be detected by the sensor. Linear correlation between frequency change and logarithmic number of bacterial cell concentration was found for E. coli O157:H7 from 2.67 x 10(2) to 2.67 x 10(6)CFU/ml.  相似文献   

2.
As a potential pandemic threat to human health, there has been an urgent need for rapid detection of the highly pathogenic avian influenza (AI) H5N1 virus. In this study, magnetic nanobeads amplification based quartz crystal microbalance (QCM) immunosensor was developed as a new method and application for AI H5N1 virus detection. Polyclonal antibodies against AI H5N1 virus surface antigen HA (Hemagglutinin) were immobilized on the gold surface of the QCM crystal through self-assembled monolayer (SAM) of 16-mercaptohexadecanoic acid (MHDA). Target H5N1 viruses were then captured by the immobilized antibodies, resulting in a change in the frequency. Magnetic nanobeads (diameter, 30nm) coated with anti-H5 antibodies were used for further amplification of the binding reaction between antibody and antigen (virus). Both bindings of target H5N1 viruses and magnetic nanobeads onto the crystal surface were further confirmed by environmental scanning electron microscopy (ESEM). The QCM immunosensor could detect the H5N1 virus at a titer higher than 0.0128 HA unit within 2h. The nanobeads amplification resulted in much better detection signal for target virus with lower titers. The response of the antibody-antigen (virus) interaction was shown to be virus titer-dependent, and a linear correlation between the logarithmic number of H5N1 virus titers and frequency shift was found from 0.128 to 12.8 HA unit. No significant interference was observed from non-target subtypes such as AI subtypes H3N2, H2N2, and H4N8. The immunosensor was evaluated using chicken tracheal swab samples. This research demonstrated that the magnetic nanobeads amplification based QCM immunosensor has a great potential to be an alternative method for rapid, sensitive, and specific detection of AI virus H5N1 in agricultural, food, environmental and clinical samples.  相似文献   

3.
A sensitive bacteria enrichment and detection system for viable Escherichia coli O157:H7 was developed using a piezoelectric biosensor-quartz crystal microbalance (QCM) with antibody-functionalized gold nanoparticles (AuNPs) used as detection verifiers and amplifiers. In the circulating-flow QCM system, capture antibodies for E. coli O157:H7 were first immobilized onto the QCM chip. The sample containing E. coli O157:H7 was circulated through the system in the presence of 10ml of brain heart infusion (BHI) broth for 18h. The cells of E. coli O157:H7 specifically captured and enriched on the chip surface of the QCM were identified by QCM frequency changes. Listeria monocytogenes and Salmonella Typhimurium were used as negative controls. After bacterial enrichment, detection antibody-functionalized AuNPs were added to enhance the changes in detection signal. The use of BHI enrichment further enhanced the sensitivity of the developed system, achieving a detection limit of 0-1log CFU/ml or g. The real-time monitoring method for viable E. coli O157:H7 developed in this study can be used to enrich and detect viable cells simultaneously within 24h. The unique advantages of the system developed offer great potential in the microbial analysis of food samples in routine settings.  相似文献   

4.
摘要:【目的】结合纳米技术建立检测大肠杆菌(Escherichia coli)O157︰H7高灵敏检测技术。【方法】采用化学共沉淀法制备出核心粒径约为10 nm的免疫纳米磁颗粒,柠檬酸钠还原法制备粒径约为20 nm的免疫胶体金。压电免疫传感器通过金黄色葡萄球菌蛋白A(Protein A from Staphylococcus aureus SPA)法将抗体固定于石英晶振上,两种免疫纳米颗粒借助不同的抗体连接于传感器上对检测频率信号进行放大。【结果】SPA在石英晶振上的最佳固定浓度和时间为1.2 mg/mL和40 min,抗体的最佳固定浓度和时间为1.0 mg/mL和60 min。压电免疫传感器通过两种免疫纳米颗粒的放大作用,使其对大肠杆菌O157︰H7的检测限从104 cfu/mL提高到101 cfu/mL。【结论】免疫纳米颗粒强化对压电免疫传感器的检测频率信号具有很好的放大效应,可以明显提高其检测灵敏度。  相似文献   

5.
In this paper, we describe a novel method for detecting Escherichia coli (E. coli) O157:H7 by using a quartz crystal microbalance (QCM) immunosensor based on beacon immunomagnetic nanoparticles (BIMPs), streptavidin-gold, and growth solution. E. coli O157-BIMPs were magnetic nanoparticles loaded with polyclonal anti-E. coli O157:H7 antibody (target antibody, T-Ab) and biotin-IgG (beacon antibody, B-Ab) at an optimized ratio of 1:60 (T-Ab:B-Ab). E. coli O157:H7 was captured and separated by E. coli O157-BIMPs in a sample, and the streptavidin-gold was subsequently conjugated to E. coli O157-BIMPs by using a biotin-avidin system. Finally, the gold particles on E. coli O157-BIMPs were enlarged in growth solution, and the compounds containing E. coli O157:H7, E. coli O157-BIMPs, and enlarged gold particles were collected using a magnetic plate. The QCM immunosensor was fabricated with protein A from Staphylococcus aureus and monoclonal anti-E. coli O157:H7 antibody. The compounds decreased the immunosensor's resonant frequency. E. coli O157-BIMPs and enlarged gold particles were used as "mass enhancers" to amplify the frequency change. The frequency shift was correlated to the bacterial concentration. The detection limit was 23 CFU/ml in phosphate-buffered saline and 53 CFU/ml in milk. This method could successfully detect E. coli O157:H7 with high specificity and stability. The entire procedure for the detection of E. coli O157:H7 took only 4 h.  相似文献   

6.
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were 相似文献   

7.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

8.
A functionalized microwire sensor based on dielectrophoresis (DEP) and antigen-antibody reaction was initially developed for sensitive and selective detection of E. coli O157:H7. The dynamics of gold-tungsten microwires were manipulated using an automated X-Y-Z stage and the sensing process included antibody immobilization and bacterial detection, and cell quantification. Antibodies were first immobilized on surface of the microwire to improve sensing specificity, and then coupled with DEP for capture of E. coli cells in a mixture of E. coli cells and non-conductive polystyrene beads. Afterward, fluorescein-conjugated secondary antibodies were applied to the wire for quantification of captured bacteria. Field Emission Scanning Electron Microscope (FESEM) figures and fluorescence intensities of bacteria on the wire validated the sensing mechanism. The entire immobilization and detection procedure could be completed within 30 min with simple operations. Performance of the microwire sensor was not significantly affected when conducted in orange juice. In addition, the detection limit of this sensor was about 5 bacterial cells per microwire in 1000 CFU/mL bacterial suspensions when the electric field generated at 3 MHz and 20 peak to peak voltage (V(pp)), and only targeted E. coli cells were concentrated and captured.  相似文献   

9.
A time-resolved fluorescence technique was developed to detect Escherichia coli O157:H7 in ground beef burger. After a 4.5 h enrichment period, streptavidin coated magnetic beads conjugated with biotin-labeled anti E. coli O157:H7 were used to capture the bacteria. The bacteria were, at the same time, also labeled by a nonfluorescent, europium (Eu)-tagged anti-E. coli O157:H7 antibody. The sandwiched bacterial complexes were then concentrated using a magnetic particle concentrator and washed to remove other solution components. Upon addition of an enhancement buffer, the Eu-labels were then released from the antibodies and chelated to nitrilo-triacetic acid (NTA) and trioctylphosphine oxide (TOPO) to form highly fluorescent Eu-(2-NTA)3(TOPO)2–3 micellar complexes. Delayed fluorescence associated with these complexes was measured and its intensity was used to estimate the original bacterial concentration spiked in hamburger. This approach was applied to detect E. coli O157:H7 spiked in hamburgers. The results indicated this method is able to detect 1 CFU/g of the bacteria after a brief enrichment for four and half hours at 37C. Specificity studies indicated that the approach exhibited no or limited cross reactivity to Salmonella typhimurium, E. coli K-12 or Shigella dysenteriae spiked in hamburgers. Thus, the developed approach may be used as a rapid screening procedure for E. coli O157 bacteria in foods.  相似文献   

10.
AIMS: Escherichia coli O157 is considered to be one of most important human pathogens of animal origin which causes serious clinical complications. One of the most common methods to isolate E. coli O157 is the immunomagnetic separation (IMS) technique which employs specific antibodies coupled to magnetic beads to bind and extract cells from enrichment broths followed by plating onto sorbitol MacConkey agar supplemented with cefixime and potassium tellurite (CT-SMAC) plates. The aim of this study was to determine strain variation by pulsed-field gel electrophoresis (PFGE) among E. coli O157 on IMS/CT-SMAC plates. METHODS AND RESULTS: Every suspect colony of E. coli O157 was tested following isolation by the IMS/CT-SMAC technique. From 124 colonies detected; six XbaI-PFGE profiles were identified. CONCLUSIONS: Our results demonstrate that mixed populations of E. coli O157 with distinguishable PFGE profiles that are simultaneously present in bovine faeces can be isolated with IMS/CT-SMAC technique. SIGNIFICANCE AND IMPACT OF THE STUDY: If the aim of the study was to analyse diversity of PFGE profiles of E. coli O157 in a faecal sample following isolation by the IMS/CT-SMAC technique, at least five colonies per sample should be analysed to detect different PFGE subtypes if present.  相似文献   

11.
A high density microelectrode array biosensor was developed for the detection of Escherichia coli O157:H7. The biosensor was fabricated from (100) silicon with a 2 microm layer of thermal oxide as an insulating layer, an active area of 9.6 mm2 and consists of an interdigitated gold electrode array. The sensor surface was functionalised for bacterial detection using heterobifunctional crosslinkers and immobilised polyclonal antibodies to create a biological sensing surface. Bacteria suspended in solution became attached to the immobilised antibodies when the biosensor was tested in liquid samples. The change in impedance caused by the bacteria was measured over a frequency range of 100 Hz-10 M Hz. The biosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The biosensor was able to discriminate between cellular concentrations of 10(4)-10(7)CFU/mL and has applications in detecting pathogens in food samples.  相似文献   

12.
A new in situ DNA amplification technique for microscopic detection of bacteria carrying a specific gene is described. Loop-mediated isothermal amplification (LAMP) was used to detect stxA(2) in Escherichia coli O157:H7 cells. The mild permeabilization conditions and low isothermal temperature used in the in situ LAMP method caused less cell damage than in situ PCR. It allowed use of fluorescent antibody labeling in the bacterial mixture after the DNA amplification for identification of E. coli O157:H7 cells with an stxA(2) gene. Higher-contrast images were obtained with this method than with in situ PCR.  相似文献   

13.
The use of commercial anti- Escherichia coli O157-labelled magnetic beads was investigated to improve detection of E. coli O157 by immunomagnetic separation (IMS) from a range of environments on a dairy farm. Immunomagnetic separation proved effective for separation of target cells from laboratory mixtures and during stress in sterile and non-sterile pond water. The IMS procedure was possible with a range of samples (water, faeces, slurry, grass and soil). Non-specific binding of non-target bacterial cells proved problematic in a number of sample types. However, indigenous E. coli O157 cells were detected from samples with a high faecal load, and only with use of IMS. Data on the probable survival and spread of the organism around the farm environment are also discussed.  相似文献   

14.
A modified procedure for magnetic capture of antibody-conjugated bacteria for light addressable potentiometric sensor (LAPS) detection using the Threshold System was developed. Streptavidin coated magnetic beads, partially labeled with biotinylated anti Escherichia coli O157 antibodies, were used to capture Escherichia coli O157:H7. Captured bacteria were further labeled with fluorescein-conjugated anti -E. coli O157:H7 antibodies and urease-labeled. anti-fluorescein antibody. Magnetically concentrated bacteria-containing complexes were then immobilized through streptavidin-biotin interactions on 0.45 μ biotinylated nitro-cellulose membranes assembled as sample sticks for the Threshold instrument. The rate of pH change associated with the production of NH3 by the urease in urea-containing solution was measured by a LAPS incorporated in the Threshold instrument. This approach allowed us to detect 103 to 104 CPU of cultured E. coli O157:H7 in PBS solutions. Furthermore, detectable LAPS signals of the sample sticks remained relatively constant for at least 24 h at 4C. The developed approach was applied to detect the E. coli in beef hamburger spiked with the bacteria. After a 5 to 6-h enrichment at 37C, as low as 1 CFU/g of E. coli O157:H7 in beef hamburger could be detected.  相似文献   

15.
A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated by common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The sensor is able to detect active growth of Escherichia coli cells within 1 h which is significantly faster than any conventional plating method which requires at least 24 h. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of active bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing by adding antibiotics to the nutritive layer.  相似文献   

16.
AIMS: To develop methods to assess the efficiency of immunomagnetic separation (IMS). METHODS AND RESULTS: The capturing efficiency of biosorbents for Escherichia coli O157:H7, constructed using streptavidin-coated magnetic beads and biotinylated antibodies, was tested using both in vivo and ATP bioluminescence. Both methods were suitable for the enumeration of bacteria captured by the biosorbents. The level of both ATP and in vivo bioluminescence depended on the media used, but was unaffected by the magnetic beads. The capture efficiency depended on time and sample volume, but did not depend on the length of spacer arm of the biotinylation agent. For cell concentrations of 相似文献   

17.
The aim of this study was to develop a simple and rapid method for purification of ultrapure supercoiled plasmid DNA with high yields from bacterial cultures. Nanosized superparamagnetic nanoparticles (Fe3O4) were prepared by chemical precipitation method using Fe2+, Fe3+ salt, and ammonium hydroxide under a nitrogen atmosphere. The surface of Fe3O4 nanoparticles was modified by coating with the multivalent cationic agent, polyethylenimine (PEI). The nanoparticles were characterized by transmission electron microscopy, X-ray diffraction, Fourier transformation infrared spectroscopy and superconducting quantum interference device magnetometer. The PEI-modified magnetic nanobeads were employed to simplify the purification of plasmid DNA from bacterial cells. We demonstrated a useful plasmid, pRSETB-EGFP, encoding the green fluorescent protein with T7 promoter, was amplified in DE3 strain of Escherichia coli. The loaded nanobeads are recovered by magnetically driven separation and regenerated by exposure to the elution buffer with optimal ionic strength (1.25 M) and pH (9.0). Up to approximately 35 microg of high-purity (A260/A280 ratio=1.87) plasmid DNA was isolated from 3ml of overnight bacterial culture. EGFP expression was detected by fluorescent microscopy in the transformed E. coli cells, indicating the biological activities of DNA fragments were retained after purified from magnetic nanobeads. The protocol, starting from the preparation of bacterial lysate and ending with purified plasmids takes less than 10 min. Thus, the separation and purification qualities of PEI-modified magnetic nanobeads as well as its ease of use surpass those of conventional anion-exchange resins.  相似文献   

18.
A circulating-flow piezoelectric biosensor, based on an Au nanoparticle amplification and verification method, was used for real-time detection of a foodborne pathogen, Escherichia coli O157:H7. A synthesized thiolated probe (Probe 1; 30-mer) specific to E. coli O157:H7 eaeA gene was immobilized onto the piezoelectric biosensor surface. Hybridization was induced by exposing the immobilized probe to the E. coli O157:H7 eaeA gene fragment (104-bp) amplified by PCR, resulting in a mass change and a consequent frequency shift of the piezoelectric biosensor. A second thiolated probe (Probe 2), complementary to the target sequence, was conjugated to the Au nanoparticles and used as a "mass enhancer" and "sequence verifier" to amplify the frequency change of the piezoelectric biosensor. The PCR products amplified from concentrations of 1.2 x 10(2) CFU/ml of E. coli O157:H7 were detectable by the piezoelectric biosensor. A linear correlation was found when the E. coli O157:H7 detected from 10(2) to 10(6) CFU/ml. The piezoelectric biosensor was able to detect targets from real food samples.  相似文献   

19.
A piezoelectric immunosensor was developed for rapid detection of Escherichia coli O157:H7. It was based on the immobilization of affinity-purified antibodies onto a monolayer of 16-mercaptohexadecanoic acid (MHDA), a long-chain carboxylic acid-terminating alkanethiol, self-assembled on an AT-cut quartz crystal's Au electrode surface with N-hydroxysuccinimide (NHS) ester as a reactive intermediate. The binding of target bacteria onto the immobilized antibodies decreased the sensor's resonant frequency, and the frequency shift was correlated to the bacterial concentration. The stepwise assembly of the immunosensor was characterized by means of both quartz crystal microbalance (QCM) and cyclic voltammetry techniques. Three analytical procedures, namely immersion, dip-and-dry and flow-through methods, were investigated. The immunosensor could detect the target bacteria in a range of 10(3)-10(8)CFU/ml within 30-50 min, and the sensor-to-sensor reproducibility obtained at 10(3) and 10(5) colony-forming units (CFU)/ml was 18 and 11% R.S.D., respectively. The proposed sensor was comparable to Protein A-based piezoelectric immunosensor in terms of the amount of immobilized antibodies and detection sensitivity.  相似文献   

20.
Current methods for the detection of pathogens in food and water samples generally require a preenrichment step that allows selective enrichment of the test organism. The objective of this research was to eliminate an enrichment step to allow detection of bacteria directly in food and water samples in 30 min. A high-flow-rate, fluidized bed to capture and concentrate large (bacteria and spores) and small (protein) molecules was developed. This format, ImmunoFlow, is volume independent and uses large beads (greater than 3 mm in diameter) when capturing bacteria to prevent sample clogging when testing food samples. Detection of bound targets was done using existing enzyme-linked immunosorbent assay (ELISA) protocols. Four antibodies (anti-Escherichia coli O157:H7, -Bacillus globigii, -bovine serum albumin [BSA], and -ovalbumin [OVA]) were covalently coupled to various glass and ceramic beads. Very small amounts of BSA (<1 ng) and OVA (0.2 to 4.0 microg) were detected. Various industrial and environmental samples were used to observe the effect of the sample composition on the capture of anti-B. globigii and anti-E. coli O157:H7 modified beads. The lower limit of detection for both E. coli O157:H7 and B. globigii was 1 spore/cell independent of the sample size. The activity of anti-B. globigii modified beads declined after 3 days. Anti-E. coli O157:H7 modified beads declined in their capture ability after 2 days in various storage buffers. Storage temperature (4 and 25 degrees C) did not influence the stability. The ImmunoFlow technology is capable of capturing bacteria and spores directly from samples, with subsequent detection in an ELISA format in 30 min.  相似文献   