首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to determine the vertical and lateral forces applied to the bar during a maximal and a submaximal effort bench press lifts. For this study, 10 male and 8 female recreational lifters were recruited (mean height: 1.71 ± 0.08 m; mass: 73.7 ± 13.6 kg) and were asked to perform a maximal and submaximal (80% of maximal lift) bench press. These lifts were performed with a bar instrumented to record forces applied to it, via the hands, in the vertical direction and along the long axis of the bar. To determine the position of the bar and timing of events, 3D kinematic data were recorded and analyzed for both lifts. The subjects in this study averaged a maximal lift of 63 ± 29 kg (90 ± 31% bodyweight). The peak vertical force was 115 ± 22% (percentage of load), whereas for the submaximal condition it was 113 ± 20%; these forces were statistically different between conditions; they were not when expressed as a percentage of the load (p > 0.05). During all the lifts, the lateral forces were always outward along the bar. The lateral force profile was similar to that of the vertical force, albeit at a lesser magnitude. During the lift phase, the peak lateral force was on average 26.3 ± 3.9% of the vertical force for the maximal lift and 23.7 ± 3.9% of the vertical force for the submaximal lift. Given that the amount of force applied laterally to the bar was a similar percentage of vertical force irrespective of load, it appears that the generation of lateral forces during the bench press is a result of having the muscles engaged in generating vertical force.  相似文献   

2.
The purpose of this study was to examine the differences in activation levels and times of activation for the pectoralis major and anterior deltoid when performing the concentric phase of 3 upper-body lifts. Twelve college-age men and women with various degrees of lifting experience performed 3 repetitions using the 6 repetition maximum in a barbell bench press, dumbbell bench press, and dumbbell fly while being monitored for electromyographic activity in both muscles. Motor unit activation of both muscles was not significantly different during all 3 lifts. However, dumbbell flys had significantly less relative time of activation than did barbell or dumbbell bench presses. Therefore, dumbbell flys may be better suited as an auxiliary lift, whereas barbell and dumbbell bench presses may be used interchangeably in training programs. The compatibility of the barbell and dumbbell bench presses may aid lifters in overcoming training plateaus by alternating exercises for the same muscle groups.  相似文献   

3.
Previous research has shown that individuals self-select loads for resistance training that falls below the accepted threshold for overload and do not lift to volitional fatigue. The purpose of this study was to determine the effects of a resistance training learning trial on self-selected resistance training load. A control group (5 women, 3 men) and a learning group of (4 women, 4 men) novice lifters were recruited. The control group (CG) received an orientation to selected strength machines (seated bench, leg extension, back row, biceps curl, triceps extension, shoulder press). On a subsequent training day, CG self-selected a training load, while blinded to the actual loads. The learning group (LG) received an initial orientation and also was tested for estimated 1 repetition maximum (1RM) for the seated bench press. On a subsequent day, the LG completed 2 sets of the seated bench press at 75% of estimated 1RM and were encouraged to lift until failure. On a third day, LG subjects completed a self-selected trial identical to that of the CG. Both groups were assessed for estimated 1RM for each exercise on a separate day following all trials. Comparisons between CG and LG were made using independent-means t tests and adjusted using Bonferroni's equation (p < 0.01). While subjects selected a bench press load that was 21% greater for LG (63.4 +/- 6.4% 1RM) compared to the CG (50.3 +/- 12.0%), there was no statistical significance. There were no significant differences in self-selected load for any of the other exercises. There were also no significant differences for number of repetitions or rate of perceived exertion between groups. We conclude that a learning trial of the bench press exercise to increase self-selected workload is not enough to change load self-selection.  相似文献   

4.
The purpose of this study was to measure the effects of additional eccentric loading on subsequent concentric strength. Eight subjects with some experience in weight training volunteered to perform maximal attempts in the barbell bench press using detaching hooks that allowed them to lower 105% of their concentric 1 repetition maximum (RM) and raise 100%. The detaching hooks allowed attachment of extra weight to the bar and would release from the bar at the bottom of the lift, reducing the weight lifted during the concentric phase of the lift. After determining their 1RM for the bench press, the subjects attempted to increase their performance by using a heavier eccentric load with the detaching hooks. All 8 subjects who completed the study increased their 1RMs by 5 to 15 pounds. The use of additional eccentric loading significantly (p = 0.008) increased the weight that could be lifted on the subsequent concentric phase and therefore 1RM performance. This phenomenon was a result of the enhancement of stretch-shortening cycle performance by the increased eccentric load. Athletes who are interested in developing 1RM strength in the bench press may benefit from the use of additional eccentric loading.  相似文献   

5.
Resistance exercise intensity is commonly prescribed as a percent of 1 repetition maximum (1RM). However, the relationship between percent 1RM and the number of repetitions allowed remains poorly studied, especially using free weight exercises. The purpose of this study was to determine the maximal number of repetitions that trained (T) and untrained (UT) men can perform during free weight exercises at various percentages of 1RM. Eight T and 8 UT men were tested for 1RM strength. Then, subjects performed 1 set to failure at 60, 80, and 90% of 1RM in the back squat, bench press, and arm curl in a randomized, balanced design. There was a significant (p < 0.05) intensity x exercise interaction. More repetitions were performed during the back squat than the bench press or arm curl at 60% 1RM for T and UT. At 80 and 90% 1RM, there were significant differences between the back squat and other exercises; however, differences were much less pronounced. No differences in number of repetitions performed at a given exercise intensity were noted between T and UT (except during bench press at 90% 1RM). In conclusion, the number of repetitions performed at a given percent of 1RM is influenced by the amount of muscle mass used during the exercise, as more repetitions can be performed during the back squat than either the bench press or arm curl. Training status of the individual has a minimal impact on the number of repetitions performed at relative exercise intensity.  相似文献   

6.
The purpose of our study was to examine the ability of anthropometric variables (body mass, total arm length, biacromial width) to predict bench press performance at both maximal and submaximal loads. Our methods required 36 men to visit our laboratory and submit to anthropometric measurements, followed by lifting as much weight as possible in good form one time (1 repetition maximum, 1RM) in the exercise. They made 3 more visits in which they performed 4 sets of bench presses to volitional failure at 1 of 3 (40, 55, or 75% 1RM) submaximal loads. An accelerometer (Myotest Inc., Royal Oak MI) measured peak force, velocity, and power after each submaximal load set. With stepwise multivariate regression, our 3 anthropometric variables attempted to explain significant amounts of variance for 13 bench press performance indices. For criterion measures that reached significance, separate Pearson product moment correlation coefficients further assessed if the strength of association each anthropometric variable had with the criterion was also significant. Our analyses showed that anthropometry explained significant amounts (p < 0.05) of variance for 8 criterion measures. It was concluded that body mass had strong univariate correlations with 1RM and force-related measures, total arm length was moderately associated with 1RM and criterion variables at the lightest load, whereas biacromial width had an inverse relationship with the peak number of repetitions performed per set at the 2 lighter loads. Practical applications suggest results may help coaches and practitioners identify anthropometric features that may best predict various measures of bench press prowess in athletes.  相似文献   

7.
Circuit training effectively reduces the time devoted to strength training while allowing an adequate training volume to be achieved. Nonetheless, circuit training has traditionally been performed using relatively low loads for a relatively high number of repetitions, which is not conducive to maximal muscle size and strength gain. This investigation compared physical performance parameters and cardiovascular load during heavy-resistance circuit (HRC) training to the responses during a traditional, passive rest strength training set (TS). Ten healthy subjects (age, 26 +/- 1.6 years; weight, 80.2 +/- 8.78 kg) with strength training experience volunteered for the study. Testing was performed once weekly for 3 weeks. On day 1, subjects were familiarized with the test and training exercises. On the subsequent 2 test days, subjects performed 1 of 2 strength training programs: HRC (5 sets x (bench press + leg extensions + ankle extensions); 35-second interset rest; 6 repetition maximum [6RM] loads) or TS (5 sets x bench press; 3-minute interset rest, 6RM loads). The data confirm that the maximum and average bar velocity and power and the number of repetitions performed of the bench press in the 2 conditions was the same; however, the average heart rate was significantly greater in the HRC compared to the TS condition (HRC = 129 +/- 15.6 beats x min(-1), approximately 71% maximum heart rate (HRmax), TS = 113 +/- 13.1 beats x min(-1), approximately 62% HRmax; P < 0.05). Thus, HRC sets are quantitatively similar to traditional strength training sets, but the cardiovascular load is substantially greater. HRC may be an effective training strategy for the promotion of both strength and cardiovascular adaptations.  相似文献   

8.
Some research suggests that strength improvements are greater when resistance training continues to the point at which the individual cannot perform additional repetitions (i.e., repetition failure). Performing additional forced repetitions after the point of repetition failure and thus further increasing the set volume is a common resistance training practice. However, whether short-term use of this practice increases the magnitude of strength development with resistance training is unknown and was investigated here. Twelve basketball and 10 volleyball players trained 3 sessions per week for 6 weeks, completing either 4 x 6, 8 x 3, or 12 x 3 (sets x repetitions) of bench press per training session. Compared with the 8 x 3 group, the 4 x 6 protocol involved a longer work interval and the 12 x 3 protocol involved higher training volume, so each group was purposefully designed to elicit a different number of forced repetitions per training session. Subjects were tested on 3- and 6-repetition maximum (RM) bench press (81.5 +/- 9.8 and 75.9 +/- 9.0 kg, respectively, mean +/- SD), and 40-kg Smith Machine bench press throw power (589 +/- 100 W). The 4 x 6 and 12 x 3 groups had more forced repetitions per session (p < 0.01) than did the 8 x 3 group (4.1 +/- 2.6, 3.1 +/- 3.5, and 1.2 +/- 1.8 repetitions, respectively), whereas the 12 x 3 group performed approximately 40% greater work and had 30% greater concentric time. As expected, all groups improved 3RM (4.5 kg, 95% confidence limits, 3.1- 6.0), 6RM (4.7 kg, 3.1-6.3), bench press throw peak power (57 W, 22-92), and mean power (23 W, 4-42) (all p < or = 0.02). There were no significant differences in strength or power gains between groups. In conclusion, when repetition failure was reached, neither additional forced repetitions nor additional set volume further improved the magnitude of strength gains. This finding questions the efficacy of adding additional volume by use of forced repetitions in young athletes with moderate strength training experience.  相似文献   

9.
The purpose of this study was to present an equation that accurately predicts 1 repetition maximum (RM) over a wide range of repetitions to fatigue (RTF) for 4 different machine resistance exercises in postmenopausal women. Seventy trained women (age = 57.4 +/- 3.1 years) performed maximal and submaximal repetitions on leg press, bench press, rowing, and leg adduction machines at the conclusion of a 2-year training program. Maximal repetitions were performed on each exercise in the following ranges: 3-5RM, 6-10RM, 11-15RM, and 16-20RM. Special regard was taken to maintain the identical execution of each test (i.e., range of motion, starting angle, speed of movement). One cubic polynomial (w(i) [0.988-0.0000584 r(i)(3) + 0.00190 r(i)(2) + 0.0104 r(i),] where w(i) is the load of measurement I, and r(i) is the number of repetitions) accurately predicted 1RM from RTF with mean absolute differences between actual 1RM and predicted 1RM for the 4 exercises of 1.5-3.1% and with coefficients of variation of <3.3%. Equation accuracy was independent of the exercise type or the number of RTF. Thus, this study supported the validity of RTF to adequately estimate 1RM over a wide range of repetitions and within different exercises in trained, older female subjects.  相似文献   

10.
This study examined the effects of verbal messages on bench press efficacy: the confidence to lift progressively heavier weights for 1 repetition. Thirty-two women who had not bench pressed within the previous 18 months were assigned to 1 of 2 groups and exposed to 2 sources of efficacy information. First, subjects in both groups performed 10 repetitions on a fixed movement, vertical bench press machine and completed the bench press efficacy scale. Next, each group received 1 of 2 possible verbal messages. Both messages included the speaker's strength training qualifications. In addition, one message conveyed specific performance feedback while the other contained more general information. Then efficacy was measured again. Results indicated both messages strengthened efficacy. Strength professionals who work one-on-one with novice women should: (a) make sure lifters are aware of their professional qualifications, (b) provide specific feedback, and (c) profess their beliefs in the lifters' abilities to perform the exercises.  相似文献   

11.
The purpose of this study was to determine the rate of recovery for recreational weight trainers between 2 sets of bench press to volitional exhaustion. Twenty-eight men performed 2 sets of the bench press at 75% of their previously determined 1 repetition maximum (1RM) to volitional exhaustion. Rest periods of 1, 3, or 5 minutes between sets were utilized on the 3 separate testing days. There was a significant decrease in the number of repetitions performed between the second sets at all rest periods. There were no significant differences in work performed (repetitions x weight) during the second set with the 3- and 5-minute rest periods, but the total work with a 1-minute rest period (1,389.1 +/- 529.9) was significantly less than both the 3- (1,494.9 +/- 451.0) and 5-minute (1,711.4 +/- 478.0) rest period. The data indicated that subjects were unable to fully recover between the first and second sets of maximal resistance exercise, regardless of the rest period. However, subjects were able to maintain a performance level of 8-12 repetitions and sustain the total work performed per set with as little as 3 minutes rest between sets.  相似文献   

12.
The purpose of this study was to investigate the importance of training leading to repetition failure in the performance of 2 different tests: 6 repetition maximum (6RM) bench press strength and 40-kg bench throw power in elite junior athletes. Subjects were 26 elite junior male basketball players (n = 12; age = 18.6 +/- 0.3 years; height = 202.0 +/- 11.6 cm; mass = 97.0 +/- 12.9 kg; mean +/- SD) and soccer players (n = 14; age = 17.4 +/- 0.5 years; height = 179.0 +/- 7.0 cm; mass = 75.0 +/- 7.1 kg) with a history of greater than 6 months' strength training. Subjects were initially tested twice for 6RM bench press mass and 40-kg Smith machine bench throw power output (in watts) to establish retest reliability. Subjects then undertook bench press training with 3 sessions per week for 6 weeks, using equal volume programs (24 repetitions x 80-105% 6RM in 13 minutes 20 seconds). Subjects were assigned to one of two experimental groups designed either to elicit repetition failure with 4 sets of 6 repetitions every 260 seconds (RF(4 x 6)) or allow all repetitions to be completed with 8 sets of 3 repetitions every 113 seconds (NF(8 x 3)). The RF(4 x 6) treatment elicited substantial increases in strength (7.3 +/- 2.4 kg, +9.5%, p < 0.001) and power (40.8 +/- 24.1 W, +10.6%, p < 0.001), while the NF(8 x 3) group elicited 3.6 +/- 3.0 kg (+5.0%, p < 0.005) and 25 +/- 19.0 W increases (+6.8%, p < 0.001). The improvements in the RF(4 x 6) group were greater than those in the repetition rest group for both strength (p < 0.005) and power (p < 0.05). Bench press training that leads to repetition failure induces greater strength gains than nonfailure training in the bench press exercise for elite junior team sport athletes.  相似文献   

13.
This study examined ratings of perceived exertion (RPE) and electromyography (EMG) during resistance exercise in recreational and novice lifters. Fourteen novice (age = 21.5 +/- 1.5 years) and 14 recreationally trained (age = 21.9 +/- 2.2 years) women volunteered to perform the bench press exercise at 60 and 80% of their 1 repetition maximum (1RM). RPE and EMG were measured during both intensities. Statistical analyses revealed that active muscle RPE increased as resistance exercise intensity increased from 60% 1RM to 80% 1RM (12.32 +/- 1.81 vs. 15.14 +/- 1.74). Integrated EMG also increased as resistance exercise intensity increased from 60% 1RM to 80% 1RM (in the pectoralis major; 98.62 +/- 17.54 vs. 127.98 +/- 29.02). No significant differences in RPE or EMG were found between novice and recreational lifters. These results indicate that RPE is related to the relative exercise intensity lifted as well as muscle activity during resistance exercise for both recreational and novice lifters. These results support the use of RPE as a method of resistance exercise intensity estimation for both types of lifters.  相似文献   

14.
This crossover study was conducted to investigate the effects of a 1-set and 3-set strength training program. The subjects were untrained men and women who were randomly signed into 1 of 3 groups: 10 subjects trained during the first 9 weeks (training period 1) with 1 set and 8-12 repetitions per set. After the break (9 weeks), they trained with 3 sets and 8-12 repetitions in training period 2. Twelve subjects started with the 3-set program and continued with the 1-set regime after the break. The control group (n = 7) did not train. The subjects were tested on 1 repetition maximum (1RM) for the biceps curl, leg press (unilateral: left and right), and bench press. Analysis of the data was done in a sampled manner for each strength training program (1-set and 3-set). The 1-set (n = 22) and 3-set (n = 22) programs led to significantly (p < 0.05) improved 1RM performances in every exercise. The relative improvements (%) for the 1RM were significantly higher during the 3-set program for the biceps curl and the bench press compared with the 1-set program. The control group exhibited no changes in any of the tested parameters over the course of this study. The design of this study allowed insight into the effects of different strength training volume without any genetical variations. The same subjects improved their 1RM during the 3-set program by 2.3 kg (biceps curl; corresponding effect size = 0.24), 8.9 kg (leg press right; 0.30), 10.9 kg (leg press left; 0.28), and 2.5 kg (bench press; 0.09) more than during the 1-set program. Depending on the goals of each trainee, these differences between the effects of different strength training volumes indicate that it may be worth spending more time on working out with a 3-set strength training regime.  相似文献   

15.
During the concentric movement of the bench press, there is an initial high-power push after chest contact, immediately followed by a characteristic area of low power, the so-called "sticking region." During high-intensity lifting, a decline in power can result in a failed lift attempt. The purpose of this study was to determine the validity of an optical encoder to measure power and then employ this device to determine power changes during the initial acceleration and sticking region during fatiguing repeated bench press training. Twelve subjects performed a free weight bench press, a Smith Machine back squat, and a Smith Machine 40-kg bench press throw for power validation measures. All barbell movements were simultaneously monitored using cinematography and an optical encoder. Eccentric and concentric mean and peak power were calculated using time and position data derived from each method. Validity of power measures between the video (criterion) and optical encoder scores were evaluated by standard error of the estimate (SEE) and coefficient of variation (CV). Seven subjects then performed 4 sets of 6 free weight bench press repetitions progressively increasing from 85 to 95% of their 6 repetition maximum, with each repetition continually monitored by an optical encoder. The SEE for power ranged from 3.6 to 14.4 W (CV, 1.0-3.0%; correlation, 0.97-1.00). During the free weight bench press training, peak power declined by approximately 55% (p < 0.01) during the initial acceleration phase of the final 2 repetitions of the final set. Although decreases in power of the sticking point were significant (p < 0.01), as early as repetition 5 (-40%) they reached critically low levels in the final 2 repetitions (>-95%). In conclusion, the optical encoder provided valid measures of kinetics during free weight resistance training movements. The decline in power during the initial acceleration phase appears a factor in a failed lift attempt at the sticking point.  相似文献   

16.
The purpose of this study was to investigate the effectiveness of 4 weeks of low-intensity resistance training with blood-flow occlusion on upper and lower body muscular hypertrophy and muscular strength in National Collegiate Athletic Association Division IA football players. There were 32 subjects (average age 19.2 ± 1.8 years) who were randomized to an occlusion group or control group. The athletes performed 4 sets of bench press and squat in the following manner with or without occlusion: 30 repetitions of 20% predetermined 1 repetition maximum (1RM), followed by 3 sets of 20 repetitions at 20% 1RM. Each set was separated by 45 seconds. The training duration was 3 times per week, after the completion of regular off-season strength training. Data collected included health history, resting blood pressure, pretraining and posttraining bench press and squat 1RM, upper and lower chest girths, upper and lower arm girths, thigh girth, height, and body mass. The increases in bench press and squat 1RM (7.0 and 8.0%, respectively), upper and lower chest girths (3 and 3%, respectively), and left upper arm girth were significantly greater in the experiment group (p < 0.05). Occlusion training could provide additional benefits to traditional strength training to improve muscular hypertrophy and muscular strength in collegiate athletes.  相似文献   

17.
Twelve experienced male weight lifters performed a rebound bench press and a purely concentric bench press lift. Data were obtained pertaining to 1) the benefits to concentric motion derived from a prior stretch and 2) the movement frequency adopted during performance of the stretch-shorten cycle (SSC) portion of the rebound bench press lift. The subjects also performed a series of quasi-static muscular actions in a position specific to the bench press movement. A brief perturbation was applied to the bar while these isometric efforts were maintained, and the resulting damped oscillations provided data pertaining to each subject's series elastic component (SEC) stiffness and natural frequency of oscillation. A significant correlation (r = -0.718, P less than 0.01) between maximal SEC stiffness and augmentation to concentric motion derived from prior stretch was observed. Subjects were also observed to perform the SSC portion of the rebound bench press movement to coincide with the natural frequency of oscillation of their SEC. These results are interpreted as demonstrating that the optimal stiffness in a rebound bench press lift was a resonant-compliant SEC.  相似文献   

18.
The purpose of this study was to determine if explosive upper-body performance could be improved when it was preceded by conditioning contraction protocols that incorporate resistance exercise. Providing that performance was enhanced, it was also the intention to determine the optimal conditioning contraction load for enhancing performance. Eight recreationally trained men completed 4 experimental sessions. Each session consisted of a warm-up, 3 bench press throws (pre), a conditioning protocol, and 3 bench press throws (post). The different conditioning protocols consisted of 5 bench press repetitions using 100, 75, or 50% of 5 repetition maximum (5RM) strength. The fourth protocol, in which no repetitions were completed, acted as a control. Participants performed each conditioning protocol on a different day, and the order in which the protocols were performed was randomized. Average power, assessed during the bench press throws, was determined for the starting segment and the end segment (point of bar release) for each throw. Comparisons in average power, for each segment of the bench press 1RM, were made between the pre- and postconditioning protocol bench press throws. None of the conditioning protocols had an effect on bench press throw performance in either of the 2 segments of the movement. The results suggest there is no performance advantage when explosive upper-body movement is preceded by resistance exercise of varying loads. Alternatively, the performance of a set of resistance exercise did not compromise explosive upper-body performance. Considering this, training methods that combine both resistance exercise and plyometric-like exercise may offer a practical and time-efficient training system.  相似文献   

19.
The purpose of the current study was to compare the effect of 3 different rest intervals on multiple sets of the bench press exercise performed with heavy vs. light loads. Sixteen resistance-trained men performed 2 testing sessions each week for 3 weeks. During the first testing session each week, 5 consecutive sets of the bench press were performed with 80% of 1 repetition maximum (1RM) and with a 1-, 2-, or 3-minute rest interval between sets. During the second testing session each week the same procedures were repeated with 50% of 1RM. The total repetitions completed and the sustainability of repetitions were compared between rest conditions and between loads. For each load, resting 3 minutes between sets resulted in significantly greater total repetitions vs. resting 2 minutes (p = 0.000) or 1 minute (p = 0.000) between sets. However, the sustainability of repetitions was not significantly different between loads (p = 0.849). These results can be applied to weekly bench press workouts that undulate between heavy (i.e., 80% 1RM) and light (i.e., 50% 1RM) intensities. When the training goal is maximal strength development, 3 minutes of rest should be taken between sets to avoid significant declines in repetitions. The ability to sustain repetitions while keeping the intensity constant may result in a higher training volume and consequently greater gains in muscular strength.  相似文献   

20.
The purpose of this investigation was to compare the effects of single-set strength training and 3-set strength training during the early phase of adaptation in 18 untrained male subjects (age, 20-30 years). After initial testing, subjects were randomly assigned to either the 3L-1U group (n = 8), which trained 3 sets in leg exercises and 1 set in upper-body exercises, or the 1L-3U group (n = 10), which trained 1 set in leg exercises and 3 sets in upper-body exercises. Testing was conducted at the beginning and at the end of the study and consisted of 2 maximal isometric tests (knee extension and bench press) and 6 maximal dynamic tests (1 repetition maximum [1RM] tests). Subjects trained 3 days per week for 6 weeks. After warm-up, subjects performed 3 leg exercises and 4 upper-body exercises. In both groups, each set consisted of 7 repetitions (reps) with the load supposed to induce muscular failure after the seventh rep (7RM load). After 6 weeks of training, 1RM performance in all training exercises was significantly increased (10-26%, p < 0.01) in both groups. The relative increase in 1RM load in the 3 leg exercises was significantly greater in the 3L-1U group than in the 1L-3U group (21% vs. 14%, p = 0.01). However, the relative increase in 1RM load in the 3 upper-body exercises was similar in the 3L-1U group (16%) and the 1L-3U group (14%). These results show a superior adaptation to 3-set strength training, compared with 1-set strength training, in leg exercises but not in upper-body exercises during the early phase of adaptation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号