首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new amperometric microbial biosensor based on Saccharomyces cerevisiae NRRL-12632 cells, which had been induced for lysine oxidase enzyme and immobilized in gelatin by a cross-linking agent was developed for the sensitive determination of L-lysine amino acid. To construct the microbial biosensor S. cerevisiae cells were activated and cultured in a suitable culture medium. By using gelatine (8.43 mg cm(-2)) and glutaraldehyde (0.25%), cells obtained in the logarithmic phase of the growth curve at the end of a 14 h period were immobilized and fixed on a pretreated oxygen sensitive Teflon membrane of a dissolved oxygen probe. The assay procedure of the microbial biosensor is based on the determination of the differences of the respiration activity of the cells on the oxygenmeter in the absence and the presence of L-lysine. According to the end point measurement technique used in the experiments it was determined that the microbial biosensor response depended linearly on L-lysine concentrations between 1.0 and 10.0 microM with a 1 min response time. In optimization studies of the microbial biosensor, the most suitable microorganism quantities were found to be 0.97x10(5)CFU cm(-2). In addition phosphate buffer (pH 7.5; 50 mM) and 30 degrees C were obtained as the optimum working conditions. In characterization studies of the microbial biosensor some parameters such as substrate specificity, interference effects of some substances on the microbial biosensor responses, reproducibility of the biosensor and operational and storage stability were investigated.  相似文献   

2.
The lyophilized biomass of White rot fungi (Phanerochaete chrysosporium ME446) was immobilized in gelatine using glutaraldehyde crosslinking agent on a Pt working electrode. The fungal cells retained their laccase activity under entrapped state. The immobilized cells were used as a source of laccase to develop amperometric epinephrine biosensor. The catalytic action of the laccase in the biosensor released an epinephrinequinone as a result of redox activity, thereby causing an increase in the current. The optimal working conditions of the biosensor were carried out at pH 4.5 (50 mM acetate buffer containing 100 mM K(3)Fe(CN)(6)), and 20°C. The sensor response was linear over a range of 5-100 μM epinephrine. The detection limit of the biosensor was found to be 1.04 μM. In the optimization and characterization studies of the microbial biosensor some parameters such as effect of fungi and gelatine amount, percentage of glutaraldehyde on the biosensor response and substrate specificity were carried out. In the application studies of the biosensor, sensitive determination of epinephrine in pharmaceutical ampules was investigated.  相似文献   

3.
Different branches of industry need to use phenolic compounds (PCs) in their production, so determination of PCs sensitively, accurately, rapidly, and economically is very important. For the sensitive determination of PCs, some biosensors based on pure polyphenol oxidase, plant tissue and microorganisms were developed before. But there has been no study to develop a microbial phenolic compounds biosensor based on Lactobacillus species, which contain polyphenol oxidase enzyme. In this study, we used different forms of Lactobacillus species as enzyme sources of biosensor and compared biosensor performances of these forms for determination of PCs. For this purpose, we used lyophilized Lactobacillus cells (containing L. bulgaricus, L. acidophilus, Streptococcus thermophilus), pure L. acidophilus, pure L. bulgaricus, and L. acidophilus- and L. bulgaricus adapted to catechol in Lactobacilli MRS Broth. The most suitable form was determined and optimization studies of the biosensor were carried out by using this form. For preparing the bioactive layer of the biosensor, the Lactobacillus cells were immobilized in gelatin by using glutaraldehyde. In the study, we used catechol as a substrate. Phenolic compound determination is based on the assay of the differences on the respiration activity of the cells on the oxygen meter in the absence and the presence of catechol. The microbial biosensor response depends directly on catechol concentration between 0.5 and 5.0 mM with 18 min response time. In the optimization studies of the microbial biosensor the most suitable microorganism amount was found to be 10 mg, and also phosphate buffer (pH 8.0; 50 mM) and 37.5 °C were obtained as the optimum working conditions. In the characterization studies of the microbial biosensor some parameters such as substrate specificity on the biosensor response and operational and storage stability were examine. Furthermore, the determination of PC levels in synthetic wastewater, industrial wastewater, and milk products was investigated by using the developed biosensor under optimum conditions.  相似文献   

4.
Application of a biosensor for monitoring of ethanol   总被引:4,自引:0,他引:4  
An alcohol biosensor for the measurement of ethanol has been developed. It comprises an alcohol oxidase/chitosan immobilized eggshell membrane and a commercial oxygen sensor. Ethanol determination is based on the depletion of dissolved oxygen content upon exposure to ethanol solution. The decrease in oxygen level was monitored and related to the ethanol concentration. The biosensor response depends linearly on ethanol concentration between 60 microM and 0.80 mM with a detection limit of 30 microM (S/N=3) and 1 min response time. In the optimization studies of the enzyme biosensor the most suitable enzyme and chitosan amounts were found to be 1.0 mg and 0.30% (w/v), respectively. The phosphate buffer (pH 7.4, 25 mM) and room temperature (20-25 degrees C) were chosen as the optimum working conditions. In the characterization studies of the ethanol biosensor some parameters such as interference effects, operational and storage stability were studied in detail. The biosensor was also tested with various wine samples. The results of this newly developed biosensor were comparable to the results obtained by a gas chromatographic method.  相似文献   

5.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated.  相似文献   

6.
A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 microM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l(-1).  相似文献   

7.
A biosensor based on mushroom tissue homogenate for detecting some phenolic compounds (PCs) and usage of the biosensor for quantifying certain substances that inhibit the polyphenol oxidase activity in mushroom (Agaricus bisporus) tissue homogenate is described. The mushroom tissue homogenate was immobilized to the top of a Clark-type oxygen electrode with gelatin and glutaraldehyde. Optimization of the experimental parameters was done by buffer system, pH, buffer concentration, and temperature. Besides, the detection range of eight phenolic compounds were obtained with the help of the calibration graphs. Thermal stability, storage stability, and repeatability of the biosensor were also investigated. A linear response was observed from 20 x 10(-3) to 200 x 10(-3) mM phenol. The biosensor retained approximately 74% of its original activity after 25 days of storage at 4 degrees C. In repeatability studies, variation coefficient (C.V.) and standard deviation (S.D.) were calculated as 2.44% and +/-0.002, respectively. Inhibition studies revealed that the proposed biosensor was applicable for monitoring benzoic acid and thiourea in soft drinks and fruit juices.  相似文献   

8.
A biosensor for the specific determination of uric acid in urine was developed using urate oxidase (EC 1.7.3.3) in combination with a dissolved oxygen probe. Urate oxidase was immobilized with gelatin by means of glutaraldehyde and fixed on a pretreated teflon membrane to serve as enzyme electrode. The electrode response was maximum when 50 mM glycine buffer was used at pH 9.2 and 35 degrees C. The enzyme electrode response depends linearly on uric acid concentration between 5-40 microM with a response time of 5 min. The enzyme electrode is stable for more than 2 weeks and during this period over 35 assays were performed.  相似文献   

9.
A biosensor based on pyruvate oxidase (POX) enzyme was developed for the investigation of the effect of thiamine (vitamin B(1)) molecule on the activity of the enzyme. The biosensor was prepared with a chemical covalent immobilization method on the dissolved oxygen (DO) probe by using gelatin and cross-linking agent, glutaraldehyde. POX catalyzes the degradation of pyruvate to acetylphosphate, CO(2) and H(2)O(2) in the presence of phosphate and oxygen. Thiamine is an activator for POX enzyme and determination method of the biosensor was based on this effect of thiamine on the activity of the enzyme. The biosensor responses showed increases in the presence of thiamine. Increases in the biosensor responses were related to thiamine concentration. Thiamine determination is based on the assay of the differences on the biosensor responses on the oxygenmeter in the absence and the presence of thiamine. The biosensor response depend linearly on thiamine concentration between 0.025 and 0.5 microM with 2 min response time. In the optimization studies of the biosensor the most suitable enzyme amount was found as 2.5 U cm(-2) and also phosphate buffer (pH 7.0; 50 mM) and 35 degrees C were obtained as the optimum working conditions. In the characterization studies of the biosensor some parameters such as activator and interference effects of some substances on the biosensor response and reproducibility were carried out.  相似文献   

10.
A novel biosensor for homocysteine determination has been developed. The biosensor was fabricated with l-homocysteine desulfhydrase immobilized on the ammonium selective electrode by means of eggshell membrane. The measurement principle is based on determination of ammonia due to the enzymatic reaction in the medium by ammonium selective electrode. The effects of enzyme loading, glutaraldehyde concentration, pH, buffer concentration, temperature, dithiotreitol (DTT) concentration and ionic strength adjustment buffer (ISA) on the biosensor response were investigated in detail. The linear detection range and limit of detection (LOD) for homocysteine were found to be 0.15–1.8 mM and 55 μM, respectively. Finally, the homocysteine biosensor has been applied to plasma samples for determination of total homocysteine contents.  相似文献   

11.
In preparation for the development of a xylitol biosensor, the xylitol dehydrogenase of Candida tropicalis IFO 0618 was partially purified and characterized. The optimal pH and temperature of the xylitol dehydrogenase were pH 8.0 and 50 degrees C, respectively. Of the various alcohols tested, xylitol was the most rapidly oxidized, with sorbitol and ribitol being reduced at 65% and 58% of the xylitol rate. The enzyme was completely inactive on arabitol, xylose, glucose, glycerol, and ethanol. The enzyme's xylitol oxidation favored the use of NAD+ (7.9 U/mg) over NADP+ (0.2 U/mg) as electron acceptor, while the reverse reaction, D-xylulose reduction, favored NADPH (7.7 U/mg) over NADH (0.2 U/mg) as electron donor. The K(m) values for xylitol and NAD+ were 49.8 mM and 38.2 microM, respectively. For the generation of the xylitol biosensor, the above xylitol dehydrogenase and a diaphorase were immobilized on bromocyan-activated sephallose. The gel was then attached on a dissolved oxygen electrode. In the presence of vitamin K3, NAD+ and phosphate buffer, the biosensor recorded a linear response to xylitol concentration up to 3 mM. The reaction was stable after 15 min. When the biosensor was applied to a flow injection system, optimal operation pH and temperature were 8.0 and 30 degrees C, respectively. The strengths and limitations of the xylitol biosensor are its high affinity for NAD+, slow reaction time, narrow linear range of detection, and moderate affinity for xylitol.  相似文献   

12.
A highly stable and sensitive amperometric alcohol biosensor was developed by immobilizing alcohol oxidase (AOX) through Polyamidoamine (PAMAM) dendrimers on a cysteamine‐modified gold electrode surface. Ethanol determination is based on the consumption of dissolved oxygen content due to the enzymatic reaction. The decrease in oxygen level was monitored at ?0.7 V vs. Ag/AgCl and correlated with ethanol concentration. Optimization of variables affecting the system was performed. The optimized ethanol biosensor showed a wide linearity from 0.025 to 1.0 mM with 100 s response time and detection limit of (LOD) 0.016 mM. In the characterization studies, besides linearity some parameters such as operational and storage stability, reproducibility, repeatability, and substrate specificity were studied in detail. Stability studies showed a good preservation of the bioanalytical properties of the sensor, 67% of its initial sensitivity was kept after 1 month storage at 4°C. The analytical characteristics of the system were also evaluated for alcohol determination in flow injection analysis (FIA) mode. Finally, proposed biosensor was applied for ethanol analysis in various alcoholic beverage as well as offline monitoring of alcohol production through the yeast cultivation. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

13.
An amperometric biosensor has been developed for monitoring glutamine in the pulsed-batch cultivation of murine hybridoma cells. Glutamine oxidase was cross-linked with bovine serum albumin (BSA) via glutaraldehyde activation and deposited on a preactivated nylon membrane. Glutaminase was then immobilized on the protein layer and the resulting membrane was attached to the sensing area of a hydrogen peroxide probe (platinum vs silver/silver chloride polarized at +0.7 V). An orthogonal test was performed to optimize the activity of the membrane for glutamine with respect to the concentrations of glutamate oxidase, BSA, glutaminase and glutaraldehyde. There was an excellent linear relationship between the biosensor's response and glutamine in the range 0.1-3 mM. The determination of glutamine could be performed in 2 min and each membrane was reused for at least 300 consecutive analyses. The data obtained also agreed well with those high-performance liquid chromatography, thus validating the applicability of the biosensor.  相似文献   

14.
A hypoxanthine (Hx) biosensor based on immobilized xanthine oxidase (XO) as the bio-component was developed and studied for the rapid analysis of fish (sweet water and marine) and goat meat samples. The biosensor was standardized for the determination of Hx in the range of 0.05 to 2 mM. Crosslinking with glutaraldehyde in presence of BSA as a spacer molecule was used for the method of immobilization. One layer of gelatin (10%) was applied over the immobilized enzyme layer to reduce the leaching out of enzyme from the membrane (cellulose acetate) matrix. The optimum pH of the immobilized system was determined to be 8.5 at 25 degrees C instead 7.0-7.2 for free enzyme system. Km and Vmax values were determined for the immobilized system. The developed sensor was applied to determine the amount of Hx present in fish and meat over a period of time. The stability of the enzyme immobilized membrane was also tested over a period of 30 days.  相似文献   

15.
A monosodium glutamate (MSG) biosensor made by co-immobilized L-glutamate oxidase (L-GLOD) and L-glutamate dehydrogenase (L-GLDH) as the bio-component based on substrate recycling for highly sensitive MSG or L-glutamate determination, has been developed. Regeneration of MSG by substrate recycling provided an amplification of the sensor response. Higher signal amplification was found in the presence of ammonium ion. The sensor was standardized to determine MSG in the range of 0.02-3.0 mg/L. Linearity was obtained from 0.02 to 1.2 mg/L in presence of ammonium ion (10 mM) and NADPH (reduced nicotinamide adenine dinucleotide phosphate) (2 mM), but in absence of L-GLDH, the detection limit of MSG is confined to 0.1 mg/L. The apparent Km for MSG with L-GLOD-L-GLDH coupled reaction was 0.4451 mM but 1.9222 mM when only L-GLOD was immobilized. Cross linking with glutaraldehyde in the presence of bovine serum albumin (BSA) as a spacer molecule has been used for the method of immobilization. The response time of the sensor was 2 min. The optimum pH and temperature of the biosensor has been determined as 7+/-2 and 25+/-2 degrees C, respectively. The enzyme immobilized on the membrane was used for over 50 measurements. The standard error of the sample measurement was 4-5%. The activity of the enzyme-immobilized membrane was tested over a period of 60 days.  相似文献   

16.
Abstract

A new amperometric sensor has been fabricated for sensitive and rapid quantification of ethanol. The biosensor assembly was prepared by covalently immobilizing alcohol oxidase (AOX) from Pichia pastoris onto chemically modified surface of polyvinylchloride (PVC) beaker with glutaraldehyde as a coupling agent followed by immobilization of horseradish peroxidase (HRP), silver nanoparticles (AgNPs), chitosan (CHIT), carboxylated multi-walled carbon nanotubes (c-MWCNTs) and nafion (Nf) nanocomposite onto the surface of Au electrode (working electrode). Owing to properties such as chemical inertness, light weight, weather resistance, corrosion resistance, toughness and cost-effectiveness, PVC membrane has attracted a growing interest as a support for enzyme immobilization in the development of biosensors. The amperometric biosensor displayed optimum response within 8?s at pH 7.5 and 35°C temperature. A linear response to alcohol in the range of 0.01mM–50?mM and 0.0001?µM as a minimum limit of detection was displayed by the proposed biosensor with excellent storage stability (190?days) at 4°C. The sensitivity of the sensor was found to be 155?µA mM?1?cm?2. A good correlation (R2?=?0.99) was found between alcohol level in commercial samples as evaluated by standard ethanol assay kit and the current biosensor which validates its performance.  相似文献   

17.
A fluorescent glucose biosensor was constructed by immobilizing glucose oxidase on a bamboo inner shell membrane with glutaraldehyde as a cross-linker. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution with a concomitant increase in the fluorescence intensity of an oxygen transducer, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(Pi) ditetrakis(4-chlorophenyl)borate. The enzyme immobilization, effect of pH, temperature and ionic strength have been studied in detail. The biosensor exhibited repeatable response to a 2.0 mM glucose solution with a relative standard deviation of 3.0% (n = 10). It showed good storage stability and maintained 95% of its initial response after it had been kept at 4 degrees C for 8 months. The biosensor has a linear response range of 0.0-0.6 mM glucose with a detection limit of 58 microM (S/N = 3). Common potential interferants in samples do not pose any significant interference on the response of the glucose biosensor. It was successfully applied to the determination of glucose content in some commercial wines and medical glucose injections.  相似文献   

18.
Receptor elements for biosensors based on Hansenula polymorpha NCYC 495 ln yeast cells for ethanol assay were developed using two ways of cell immobilization, i.e., physical adsorption on a glass fiber membrane and covalent binding on a modified nitrocellulose membrane. The linear diapason of ethanol assays for a biosensor based on yeast cells adsorbed on glass fiber was 0.05–1.18; for a biosensor based on yeasts immobilized on a nitrocellulose membrane, 0.2–1.53 mM. Receptor elements based on sorbed cells possessed 2.5 times higher long-term stability. The time response was 1.5 times less for cells immobilized using DEAE-dextran and benzoquinone. The results of ethyl alcohol assays using biosensors based on cells immobilized via adsorption and covalent binding, as well as using the standard areometric method, had high correlation coefficients (0.998 and 0.997, respectively, for the two ways of immobilization). The results indicate the possibility to consider the described models of receptor elements for biosensors as prototypes for experimental samples for practical use.  相似文献   

19.
The rapid determination of waste-water quality of waste-water treatment plants in terms of pollutional strength, i.e. biochemical oxygen demand (BOD) is difficult or even impossible using the chemical determination method. The present study reports the determination of BOD within minutes using microbial BOD sensors, as compared to the 5-day determination using the conventional method. Multiple criteria establish the basis for the development of a BOD biosensor useful for rapid and reliable BOD estimation in industrial waste-waters. Of these, preparation of a suitable novel immobilized microbial membrane used in conjunction with an apt transducer is discussed. As a result, a microbial biosensor based on a formulated, synergistic, pre-tested microbial consortium has been developed for the measurement of BOD load of various industrial waste-waters. The sensor showed maximum response in terms of current difference, when a cell concentration of 2.25 x 10(10) CFU, harvested in their log phase of growth were utilized for microbial membrane construction. The sensor showed a stability of 180 days when the prepared membranes were stored at a temperature of 4 degrees C in 50 mM phosphate buffer of pH 6.8. The reusability of the immobilized membranes was up to 200 cycles without appreciable loss of their response characteristics. A linear relationship between the current change and a glucose-glutamic acid (GAA) concentration up to 60 mg l(-1) was observed (r=0.999). The lower detection limit was 1.0 mg l(-1) BOD. The sensor response was reproducible within +/-5% of the mean in a series of ten samples having 44 mg l(-1) BOD using standard a GGA solution. When used for the BOD estimation of industrial waste-waters, a relatively good agreement was found between the two methods, i.e. 5-day BOD and that measured by the developed microbial sensor.  相似文献   

20.
Cellular sensors for methanol and ethanol determination were developed using immobilized mutant cells of methylotrophic yeasts Hansenula polymorpha and Pichia pinus (able to extrude protons in the presence of alcohol) and pH-sensitive field effect transistors (pH-SFETs). The intact cells of yeasts were immobilized in Ca-alginate gel to obtain a biomembrane. The minimal detectable response was obtained to approximately 0.5 mM of methanol and ethanol, a linear dependence of biosensor's response on the logarithmic alcohol concentration was observed in the range from 5 to 100 mM for both types of alcohol. The prospects for application of biosensors to determine alcohols in the analytical practice are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号