首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
"Macromolecules to PDMS transfer" technique relying on the direct entrapment of macromolecules spots during PDMS polymerisation is proposed as an alternative for the easy and simple PDMS surface modification. In the present work, the development of three different applications based on this procedure is presented as proof of the method potentialities. First, C-reactive protein (CRP) sandwich immunoassay using immobilised monoclonal anti-CRP antibodies was developed for sepsis diagnosis. The preserved integrity of the immobilised monoclonal immunoglobulin permitted the sensitive detection of free CRP in human sera (LOD=12.5 microg/L, detection ranging over two decades). Then, rheumatoid arthritis diagnosis through the rheumatoid factor (RF) detection based on rabbit immunoglobulins immobilisation allowed the detection of specific antibodies in human sera samples down to low RF levels (detection range 5.3-485 IU/mL). Finally, the "Macromolecules to PDMS transfer" procedure was used to easily and rapidly produce fibronectin-based cell culture arrays. The successful attachment of HeLa and BALB/3T3 cells was demonstrated with optical microscopy and specific staining of actin and vinculin.  相似文献   

2.
The mechanisms behind the degeneration of neurons in diseases such as Alzheimer's disease (AD) and amyotrophic lateral sclerosis (ALS) are not fully understood. However, oxidation of certain amino acid residues in proteins may contribute to cell injury and some of these oxidized amino acids may also be suitable as biomarkers for oxidative injury. Therefore, it is suggested that the reaction between peroxynitrite (ONOO(-)) and tyrosine in vivo can be monitored by monitoring the formation of 3-nitrotyrosine (3-NT). In this work, a newly developed gas chromatographic-mass spectrometric method was applied to human cerebrospinal fluid (CSF). The free 3-NT levels were determined in the CSF from 19 controls, 17 patients with AD and 14 patients with ALS. The levels of free 3-NT in the CSF were considerably lower than those previously reported. The majority of the patients with AD or ALS had free 3-NT levels in the same range as seen in the control individuals and only a few patients showed increased levels of free 3-NT.  相似文献   

3.
C-reactive protein (CRP), a 115 kDa pentameric protein, is one of the important cardiac biomarkers that are indicative of coronary heart events. Sensitive detection of CRP in human serum is critical for the diagnosis of coronary heart disease. This work presents a sensitive sandwich immunoassay for the detection of CRP in human serum using zinc sulfide (ZnS) nanoparticles as novel fluorescence signal transducers. In this assay, monoclonal anti-CRP antibodies are used to capture CRP in human serum, and then the captured CRPs are incubated with biotinylated monoclonal anti-CRP and Neutravidin coated ZnS nanoparticle to form sandwich immunocomplexes. Quantification of CRP occurs when zinc ions released from ZnS nanoparticle labels are mixed with zinc-ion sensitive fluorescence indicator Fluozin-3 for fluorescence generation. The developed assay presents a detection limit around 10 pM and a detection range with more than two orders of magnitude.  相似文献   

4.
We synthesized and characterized a new tagging reagent, (3R,4S)-1-(4-(aminomethyl)phenylsulfonyl)pyrrolidine-3,4-diol (APPD), for the selective fluorogenic derivatization of 3-nitrotyrosine (3-NT) residues in peptides (after reduction to 3-aminotyrosine) and affinity enrichment. The synthetic 3-NT-containing peptide, FSAY(3-NO2)LER, was employed as a model for method validation. Furthermore, this derivatization protocol was successfully tested for analysis of 3-NT-containing proteins exposed to peroxynitrite in the total protein lysate of cultured C2C12 cells. The quantitation of 3-NT content in samples was achieved through either fluorescence spectrometry or boronate affinity chromatography with detection by specific fluorescence (excitation and emission wavelengths of 360 and 510 nm, respectively); the respective limits of detection were 95 and 68 nM (19 and 13 pmol total amount) of 3-NT. Importantly, the derivatized peptides show a strong retention on a synthetic boronate affinity column, containing sulfonamide-phenylboronic acid, under mild chromatographic conditions, affording a route to separate the derivatized peptides from large amounts (milligrams) of nonderivatized peptides and to enrich them for fluorescent detection and mass spectrometry (MS) identification. Tandem MS analysis identified chemical structures of peptide 3-NT fluorescent derivatives and revealed that the fluorescent derivatives undergo efficient backbone fragmentations, permitting sequence-specific identification of protein nitration at low concentrations of 3-NT in complex protein mixtures.  相似文献   

5.
In this work, the Z-domain of protein A was autodisplayed on the surface of the Escherichia coli outer membrane as a fusion protein of AIDA-1, and then layered on a microplate in order to develop a hypersensitive immunoassay. By using microplates with controlled hydrophilicity the formation of outer membrane layer was carried out, and the driving force for the layer formation was proven to be a hydrophobic interactions. Through the orientation control of the immobilized antibodies by using autodisplayed Z-domains, the limit of detection (LOD) and the sensitivity of this new immunoassay were determined to have improved as much as 30-fold compared to the conventional ELISA. The applicability of the new immunoassay for medical diagnosis was demonstrated by the detection of C-reactive protein (CRP) which is known to be a biomarker protein for inflammatory diseases.  相似文献   

6.
Nitric oxide (NO) is involved in many physiological processes, such as blood pressure control, neurotransmission, inhibition of platelet and neutrophil adherence, and the ability to kill tumor cells and parasites. The indirect determination of NO can be made by detection of 3-nitrotyrosine (3-NT) residues. The aim of this study was to measure the concentration of 3-NT in the brain of rats experimentally infected with Trypanosoma evansi. Twenty-four were inoculated intraperitoneally with cryopreserved blood containing 1 × 106 trypomastigotes per animal. Twenty-four animals were used as negative controls and received 0.2 mL of saline by the same route. The experimental groups (group C and T) were established according to the time after infection and the degree of parasitemia as follows: four control subgroups (C3, C5, C10 and C20) with six non-inoculated animals each and four test subgroups (T3, T5, T10 and T20) with six animals infected with T. evansi in each group. The animals were anesthetized with isoflurane and subsequently euthanized at the days 3 (C3, T3), 5 (C5, T5), 10 (C10, T10) and 20 (C20, T20) post-infection (PI). The brain was removed and dissected into cerebellum, cerebral cortex, striatum and hippocampus. Concentration of 3-NT in the brain was determined by Slot blot technique. At the day 3 PI no changes were observed in the concentration of 3-NT among the groups. There was a significant reduction (p < 0.05) of 3-NT concentration in the striatum and cerebellum at the days 5 and 10 PI, respectively. At the day 20 PI a significant increase (p < 0.05) of 3-NT was observed in the cerebellum, cerebral cortex and hippocampus from the infected animals. Therefore, T. evansi infection caused changes in the concentrations of 3-NT in the central nervous system (CNS), which may be related to clinical signs and infection management.  相似文献   

7.
Escherichia coli cells with autodisplayed Z-domains have been used for immunoassays of specific target analytes. In this study, a magnetite suspension was used for the washing step in immunoassays of E. coli cells with autodisplayed Z-domains. This approach enhanced the washing conditions for these immunoassays by determining (1) the optimal concentration of the magnetite suspension, (2) the capacity of the magnetite suspension-based washing method to recover E. coli cells, and (3) the level at which the activity of autodisplayed Z-domains is maintained. In immunoassays of C-reactive protein (CRP), the immunoassay incorporating the magnetite suspension-based washing method showed a sensitivity and limit of detection considerably higher than those of the conventional centrifugation-based washing method. The results indicated that immunoassays incorporating the magnetite suspension-based washing method are effective for medical diagnoses based on CRP assay.  相似文献   

8.
To examine the relation between lifestyle factors and oxidative stress biomarkers, this study analysed plasma 3-nitrotyrosine (3-NT), urinary 8-isoprostane and 8-hydroxy-2’- deoxyguanosine (8-OHdG) of 323 healthy Japanese without any disease. Plasma 3-NT was significantly increased by excessive exercise (p=0.010), but it was not significantly different in terms of sex, age (< 40, ≧40), BMI (<18.5, 18.5–24.9, ≧25.0), smoking (non-smokers, smokers) and alcohol drinking per week (non-drinkers, <10 units, ≧10 units). Urinary 8-isoprostane was significantly associated with alcohol drinking (p <0.01) and sex (p <0.01), although it had no significant relevance to age and exercise. Moreover, urinary 8-OHdG was positively associated with age (p <0.05) and negatively associated with BMI (p <0.05) and fasting insulin (p <0.001). However, it was not related with sex, smoking, alcohol drinking and exercise. In conclusion, the present results suggest that 3-NT, 8-isoprostane and 8-OHdG seem to be useful biomarkers for early prediction of lifestyle-related disease risk at the population level.  相似文献   

9.
Neonatal infections are a major risk factor for neonatal mortality. A reliable diagnosis of early-onset sepsis (EOS) is hampered by the variable clinical presentations of the children. We hypothesized that changes in the Se or Cu status, or the biomarkers selenoprotein P (SELENOP) or ceruloplasmin (CP) alone or in combination may be informative of EOS.We generated a new human CP-specific non-competitive immunoassay (ELISA) suitable of analysing small sample volumes and validated the method with a commercial CP source. Using this novel CP assay, we analysed a case-control study of EOS (n = 19 control newborns, n = 18 suspected cases). Concentrations of Se, Cu, SELENOP, CP, interleukin-6 (IL-6), and C-reactive protein (CRP) along with the Cu/Se and CP/SELENOP ratios were evaluated by correlation analyses as biomarkers for EOS. Diagnostic value was estimated by receiver operating characteristic (ROC) curve analyses.The new CP-ELISA displayed a wide working range (0.10–6.78 mg CP/L) and low sample requirement (2 μL of serum, EDTA-, heparin- or citrate-plasma). Plasma CP correlated positively with Cu concentrations in the set of all samples (Pearson r = 0.8355, p < 0.0001). Three of the infected neonates displayed particularly high ratios of Cu/Se and CP/SELENOP, i.e., 3.8- to 6.9-fold higher than controls. Both the Cu/Se and the CP/SELENOP ratios correlated poorly with the early infection marker IL-6, but strongly and positively with the acute-phase protein CRP (Cu/Se-CRP: Spearman ϱ = 0.583, p = 0.011; CP/SELENOP-CRP: ϱ = 0.571, p = 0.013). The ROC curve analyses indicate that a combination of biomarkers for the Se and Cu status do not improve the early identification of EOS considerably.This study established a robust, highly precise, partly validated and scalable novel CP sandwich ELISA suitable for basic and clinical research, requiring minute amounts of sample. The ratio of circulating CP/SELENOP constitutes a promising new composite biomarker for detection of EOS, at least in a subset of severely diseased children.  相似文献   

10.
This paper deals with smart bimolecular recognition for instantaneous determination. In particular, we installed the fluorescence resonance energy transfer (FRET) system in phosphorylcholine (PC) group enriched nanoparticles (NPs). The most favorable characteristics were as follows: (i) the suppression of nonspecific protein adsorption by the PC group enriched surface and (ii) simple bioassay protocol relative to the conventional enzyme-linked immunosorbent assay (ELISA). In the case of immunoassays, nonspecific interaction and complex protocols are known dominant problems. To address these issues, we designed FRET-installed NPs. Agglutination of NPs is a fundamental immunoassay technique; however, it is not quantitative. By evaluating the degree of agglutination based on the fluorescence intensity, the resulting information can be used for diagnosis. Therefore, we installed the FRET system on the surface of the NPs. In this paper, C-reactive protein (CRP) and osteopontin (OPN) were the target biomarkers for instantaneous determination, and the resulting fluorescence intensity correlated well with changes in the concentrations of the target molecules. The immunoassay protocol was quite simple, involving only the mixing of FRET-installed NPs and target molecules, such as CRP and OPN antigens. We successfully evaluated the concentration of the target biomarkers, even when human serum albumin was present as an interference molecule.  相似文献   

11.
A non-competitive immunoassay was performed by sodium dodecyl sulfate–capillary gel electrophoresis with UV detection using bovine serum albumin (BSA) and monoclonal anti-BSA. BSA, anti-BSA and their immunocomplexes were well resolved under non-denaturing conditions. A linear calibration curve was obtained and can be used for the quantification of anti-BSA. The limit of detection of anti-BSA was 0.1 μM under the present conditions. Compared with capillary zone electrophoresis, we believed that this method has the potential to be used as a more general format for performing capillary electrophoresis-based immunoassay of medium- and large-sized analytes.  相似文献   

12.
Taurine (2-aminoethanesulfonic acid) is a free sulfur-containing β-amino acid which has antioxidant, antiinflammatory and detoxificant properties. In the present study, the role of endotoxemia on peroxynitrite formation via 3-nitrotyrosine (3-NT) detection, and the possible antioxidant effect of taurine in lipopolysaccharide (LPS)-treated guinea pigs were aimed. 40 adult male guinea pigs were divided into four groups; control, endotoxemia, taurine and taurine+endotoxemia. Animals were administered taurine (300 mg/kg), LPS (4 mg/kg) or taurine plus LPS intraperitoneally. After 6 h of incubation, when highest blood levels of taurine and endotoxin were attained, the animals were sacrificed and spleen samples were collected. The amounts of 3-nitrotyrosine and taurine were measured by HPLC, and reactive nitrogen oxide species (NOx) which are stable end products of nitric oxide was measured spectrophotometrically in spleen tissues. LPS administration significantly decreased the concentration of taurine whilst increased levels of 3-NT and NOx compared with control group. It was determined that taurine treatment decreased the levels of 3-nitrotyrosine and NOx in taurine+endotoxemia group. The group in which taurine was administered alone, contradiction to well-known antioxidant effect, taurine caused elevated concentration of 3-NT and NOx. This data suggest that taurine protects spleen against oxidative damage in endotoxemic conditions. However, the effect of taurine is different when it is administered alone. In conclusion, taurine may act as an antioxidant during endotoxemia, and as a prooxidant in healthy subjects at this dose.  相似文献   

13.
Diminished nitric oxide (NO) bioactivity and enhanced peroxynitrite formation have been implicated as major contributors to atherosclerotic vascular dysfunctions. Hallmark reactions of peroxynitrite include the accumulation of 3-nitrotyrosine (3-NT) in proteins and oxidation of the NO synthase (NOS) cofactor, tetrahydrobiopterin (BH(4)). The present study sought to 1) quantify the extent to which 3-NT accumulates and BH(4) becomes oxidized in organs of apolipoprotein E-deficient (ApoE(-/-)) atherosclerotic mice and 2) determine the specific contribution of inducible NOS (iNOS) to these processes. Whereas protein 3-NT and oxidized BH(4) were undetected or near the detection limit in heart, lung, and kidney of 3-wk-old ApoE(-/-) mice or ApoE(-/-) mice fed a regular chow diet for 24 wk, robust accumulation was evident after 24 wk on a Western (atherogenic) diet. Since 3-NT accumulation was diminished 3- to 20-fold in heart, lung, and liver in ApoE(-/-) mice missing iNOS, iNOS-derived species are involved in this reaction. In contrast, iNOS-derived species did not contribute to elevated protein 3-NT formation in kidney or brain. iNOS deletion also afforded marked protection against BH(4) oxidation in heart, lung, and kidney of atherogenic ApoE(-/-) mice but not in brain or liver. These findings demonstrate that iNOS-derived species are increased during atherogenesis in ApoE(-/-) mice and that these species differentially contribute to protein 3-NT accumulation and BH(4) oxidation in a tissue-selective manner. Since BH(4) oxidation can switch the predominant NOS product from NO to superoxide, we predict that progressive NOS uncoupling is likely to drive atherogenic vascular dysfunctions.  相似文献   

14.
W Lu  C Fu  Y Chen  J Lu  Y Yao  C Shen  Z Gu 《PloS one》2012,7(7):e41448
A novel photonic suspension array has been developed for multiplex immunoassay. The carriers of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers have characteristic reflection peaks originating from their structural periodicity; therefore they do not suffer from fading, bleaching, quenching or chemical instability. In addition, the fluorescence background of SCCBs is negligible because no fluorescence materials or dyes are involved. With a sandwich method, the proposed suspension array was used for simultaneous multiplex detection of heart failure (HF) and coronary heart disease (CAD) biomarkers in one test tube. The results showed that the three biomarkers: cardiac troponin I (cTnI), C-reactive protein (CRP) and B-type natriuretic peptide (BNP) could be assayed in the ranges of 0.1-500 ng/ml, 1-500 mg/L and 0.02-50 ng/ml with detection limits of 0.01 ng/ml, 0.36 mg/L and 0.004 ng/ml at 3σ, respectively. There were no significant differences between the photonic suspension array and traditional parallel single-analyte test. This novel method demonstrated acceptable accuracy, high detection sensitivity and reproducibility and excellent storage stability. This technique provides a new strategy for low cost, automated, and simultaneous multiplex immunoassays of bio-markers.  相似文献   

15.

Background

To examine the characteristics of oxidative stress in patients with acute kidney injury (AKI) and investigate the association between plasma nitrotyrosine levels and 90-day mortality in patients with AKI.

Methodology/Principal Findings

158 patients with hospital-acquired AKI were recruited to this prospective cohort study according to RIFLE (Risk, Injury, Failure, Lost or End Stage Kidney) criteria. Twelve critically ill patients without AKI and 15 age and gender-matched healthy subjects served as control. Plasma 3-nitrotyrosine was analyzed in relation to 90-day all cause mortality of patients with AKI. The patients with AKI were followed up for 90 days and grouped according to median plasma 3-nitrotyrosine concentrations. Highest 3-NT/Tyr was detected in patients with AKI compared with healthy subjects, and critically ill patients without AKI (ANOVA p<0.001). The 90-day survival curves of patients with high 3-NT/Tyr showed significant differences compared with the curves of individuals with low 3-NT/Tyr (p = 0.001 by log rank test). Multivariate analysis (Cox regression) revealed that 3-NT/Tyr (p = 0.025) was independently associated with mortality after adjustment for age, gender, sepsis and Acute Physiology and Chronic Health Evaluation (APACHE) II score.

Conclusions/Significance

There is excess plasma protein oxidation in patients with AKI, as evidenced by increased nitrotyrosine content. 3-NT/Tyr level was associated with mortality of AKI patients independent of the severity of illness.  相似文献   

16.
Reactive nitrogen species can cause oxidative modifications of certain amino acid residues in proteins, notably the modification of tyrosine to 3-nitrotyrosine (3-NT), which is a potentially useful marker of oxidative stress. Since lung diseases are associated with airway inflammation and oxidative stress, quantification of 3-NT in exhaled breath condensate (EBC) may provide a non-invasive means for monitoring ongoing inflammatory processes. 3-NT-like immunoreactivity has previously been detected in EBC, but no definitive evidence for the presence of 3-NT in EBC is available. Here, a method based on gas chromatography/negative ion chemical ionization/tandem mass spectrometry was established for the quantification of free 3-NT in EBC. The detection limit was 0.56 pM (corresponding to 3.0 amol microl(-1) sample injected) and the method was found to give linear results (r2 > 0.999) in the concentration range of 0-5.0 nM. The coefficient of variation (CV) for within-day and between-day precision were 11 and 12%, respectively. No artifactual nitration was observed during sample processing. The method was applied to study subjects with asthma (n = 8), and healthy subjects (n = 10), but only a slight non-significant increase in 3-NT levels was found in the former group (median [interquartile ranges]; 99 [50-547] amol s(-1) vs. 75 [35-147] amol s(-1)). No correlation with exhaled nitric oxide (NO), pulmonary function or EBC levels of total protein was observed. The 3-NT levels were much lower compared to previously reported levels, based on immunochemical measurements. The method does not allow the simultaneous quantification of tyrosine in samples.  相似文献   

17.
摘要 目的:探讨2型糖尿病(T2DM)患者血清鸢尾素(Irisin)、摄食抑制因子-1(Nesfatin-1)、3-硝基酪氨酸(3-NT)水平与糖脂代谢和阻塞性睡眠呼吸暂停低通气综合征(OSAHS)的关系。方法:选择2020年4月~2021年9月期间中国人民解放军总医院京南医疗区收治的T2DM患者80例作为研究对象,根据多导睡眠图(PSG)检查结果,合并OSAHS的51例患者列为T2DM合并OSAHS组,剩余的29例纳为T2DM未合并OSAHS组。选择同期来中国人民解放军总医院京南医疗区体检的40例健康志愿者作为对照组。对比T2DM患者、对照组的Irisin、Nesfatin-1、3-NT水平,采用Pearson相关性分析显示Irisin、Nesfatin-1、3-NT与糖脂代谢指标的相关性。T2DM患者发生OSAHS的影响因素采用多因素Logistic回归分析。结果:T2DM合并OSAHS组、T2DM未合并OSAHS组Irisin低于对照组,且T2DM合并OSAHS组低于T2DM未合并OSAHS组(P<0.05)。T2DM合并OSAHS组、T2DM未合并OSAHS组Nesfatin-1、3-NT高于对照组,且T2DM合并OSAHS组高于T2DM未合并OSAHS组(P<0.05)。T2DM合并OSAHS组、T2DM未合并OSAHS组糖化血红蛋白(HbAlc)、空腹血糖(FBG)、餐后2 h血糖(2hPG)高于对照组,且T2DM合并OSAHS组高于T2DM未合并OSAHS组(P<0.05)。T2DM合并OSAHS组、T2DM未合并OSAHS组三酰甘油(TG)、低密度脂蛋白胆固醇(LDL-C)、总胆固醇(TC)较对照组高,高密度脂蛋白胆固醇(HDL-C)低于对照组(P<0.05)。Pearson相关性分析结果显示,Irisin与HbAlc、FBG、2hPG呈负相关,Nesfatin-1、3-NT与HbAlc、FBG、2hPG呈正相关(P<0.05)。T2DM合并OSAHS组、T2DM未合并OSAHS组的年龄、合并高血压、体质量指数、AHI、空腹C肽、合并冠心病对比有差异(P<0.05)。Irisin、Nesfatin-1、3-NT、HbAlc、FBG、2hPG、年龄、合并高血压是T2DM患者发生OSAHS的影响因素(P<0.05)。结论:T2DM合并OSAHS患者的Irisin、Nesfatin-1、3-NT水平表达异常,参与着机体的糖脂代谢过程及OSAHS发生,且OSAHS发生同时还受到HbAlc、FBG、2hPG、年龄、合并高血压的影响,可考虑对上述因素进行早期监测,以进行相关干预。  相似文献   

18.
Several new plasma protein biomarkers have been associated with increased risk of cardiovascular events. It would be of great value if sets of these markers could be measured in a multiplexed format at point-of-care settings. A major challenge is the extremely wide concentration range in which different plasma biomarkers are present. Two promising biomarkers for cardiac risk prediction are C-reactive protein (CRP) and N-terminal pro-brain natriuretic peptide (NTproBNP). The concentrations of these markers can differ by more than six orders of magnitude. Here we present a chip-based multiplexed assay for CRP and NTproBNP. The high-concentration analyte, CRP, is analyzed in a competitive format, whereas the low-concentration analyte, NTproBNP, is analyzed in a sandwich format. This allows concurrent measurement of the two analytes in a single multiplexed assay. The dynamic ranges for the two assays were optimized to match the relevant serum concentration ranges; thus, no dilutions were needed. Both assays exhibit good precision (5–15% in the clinically relevant concentration ranges), and the limit of detection for the NTproBNP assay was 5 ng/L. Patient plasma samples were used for comparison with clinical methods, resulting in coefficients of determination (R2) of 0.9762 and 0.9606 for NTproBNP and CRP, respectively.  相似文献   

19.
Artefacts in HPLC Detection of 3-Nitrotyrosine in Human Brain Tissue   总被引:1,自引:1,他引:0  
Abstract: An HPLC method was used for quantification of 3-nitrotyrosine (3-NT) in human postmortem brain tissue. A peak with similar retention time to 3-NT was detected in brain tissue from patients with Parkinson's disease, Huntington's chorea, multiple system atrophy, and Alzheimer's disease but not in control tissue. The peak was lost on reduction with dithionite, a criterion often used to identify 3-NT. Tissue from the same neurodegenerative diseases was analysed by HPLC using a photodiode array detector in series with an amperometric electrochemical detector, but the peak was found not to be 3-NT. The absorbance spectrum, fragmentation pattern on mass spectroscopy, and electrochemical profile of this peak do not match authentic 3-NT. A search of the mass spectroscopy databases failed to reveal its identity. The presence of this closely eluting, dithionite-reducible peak could confound analysis of human tissues for 3-NT. In vitro experiments showed that high concentrations of peroxynitrite were needed to achieve detectable levels of 3-NT in human brain tissue.  相似文献   

20.
A multiplexing bead-based platform provides an approach for the development of assays targeting specific analytes for biomonitoring and biosensing applications. Multi-Analyte Profiling (xMAP) assays typically employ a sandwich-type format using antibodies for the capture and detection of analytes of interest, and the system permits the simultaneous quantitation of multiple targets. In this study, an aptamer/antibody assay for the detection of C-reactive protein (CRP) was developed. CRP is an acute phase marker of inflammation whose elevated basal levels are correlated with an increased risk for a number of pathologies. For this assay, an RNA aptamer that binds CRP was conjugated to beads to act as the capture agent. Biotinylated anti-CRP antibody coupled to fluorescently labeled streptavidin was used for quantification of CRP. The detection limit of the CRP assay was 0.4 mg/L in diluted serum. The assay was then used to detect spiked CRP samples in the range of 0.4 to 10 mg/L in diluted serum with acceptable recoveries (extrapolated values of 70–130%), including that of a certified reference material (129% recovery). The successful incorporation of the CRP aptamer into this platform demonstrates that the exploration of other aptamer–target systems could increase the number of analytes measurable using xMAP-type assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏