首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In retinal neuroprostheses, spatial interaction between electric fields from various electrodes – electric crosstalk – may occur in multielectrode arrays during simultaneous stimulation of the retina. Depending on the electrode design and placement, this crosstalk can either enhance or degrade the functional characteristics of a visual prosthesis. To optimize the device performance, a balance must be satisfied between the constructive interference of crosstalk on dynamic range and power consumption and its negative effect on artificial visual acuity. In the present computational modeling study, we have examined the trade-off in these positive and negative effects using a range of currently available electrode array configurations, compared to a recently proposed stimulation strategy – the quasi monopolar (QMP) configuration – in which the return current is shared between local bipolar guards and a distant monopolar electrode. We evaluate the performance of the QMP configuration with respect to the implantation site and electrode geometry parameters. Our simulation results demonstrate that the beneficial effects of QMP are only significant at electrode-to-cell distances greater than the electrode dimensions. Possessing a relatively lower activation threshold, QMP was found to be superior to the bipolar configuration in terms of providing a relatively higher visual acuity. However, the threshold for QMP was more sensitive to the topological location of the electrode in the array, which may need to be considered when programming the manner in which electrode are simultaneously activated. This drawback can be offset with a wider dynamic range and lower power consumption of QMP. Furthermore, the ratio of monopolar return current to total return can be used to adjust the functional performance of QMP for a given implantation site and electrode parameters. We conclude that the QMP configuration can be used to improve visual information-to-stimulation mapping in a visual prosthesis, while maintaining low power consumption.  相似文献   

2.
Implantable cardioverter-defibrillators (ICDs) terminate ventricular tachycardia (VT) and ventricular fibrillation (VF) with high efficacy and can protect patients from sudden cardiac death (SCD). However, inappropriate shocks may occur if tachycardias are misdiagnosed. Inappropriate shocks are harmful and impair patient quality of life. The risk of inappropriate therapy increases with lower detection rates programmed in the ICD. Single-chamber detection poses greater risks for misdiagnosis when compared with dual-chamber devices that have the benefit of additional atrial information. However, using a dual-chamber device merely for the sake of detection is generally not accepted, since the risks associated with the second electrode may outweigh the benefits of detection. Therefore, BIOTRONIK developed a ventricular lead called the LinoxSMART S DX, which allows for the detection of atrial signals from two electrodes positioned at the atrial part of the ventricular electrode. This device contains two ring electrodes; one that contacts the atrial wall at the junction of the superior vena cava (SVC) and one positioned at the free floating part of the electrode in the atrium. The excellent signal quality can only be achieved by a special filter setting in the ICD (Lumax 540 and 740 VR-T DX, BIOTRONIK). Here, the ease of implantation of the system will be demonstrated.  相似文献   

3.
4.
A semimicrotitration device for reaction volumes of 0.5 to 2 ml and effective stirring of reaction solution or suspension is described. The principal part of the device is a combined glass electrode functioning as a reaction vessel (combined "cup"-glass electrode). Characteristics of the device are small volumes and great reliability. Nonspecific cholinesterase activities measured in rat plasma and liver tissue homogenates and compared with the activities of the same tissue and plasma samples measured radiometrically and spectrophotometrically illustrate the applicability of the device. The method is best suited for kinetic studies with multiple substrates of esterases, either in the soluble form or in tissue homogenates.  相似文献   

5.
An improved piezoelectric electrode acceleration device is described, which requires no specially designed electronic circuitry. The device is simple in design, compact and readily adaptable to most standard neurophysiological equipment. It will produce either sinusoidal motion or pulses, singly or continuously. A relatively pure axial motion of the electrode tip with little lateral whip is produced by the device.  相似文献   

6.
An electrochemical microdevice with separable electrode and antibody chips has been developed and applied to detect atrophic gastritis-related proteins, pepsinogen 1 (PG1) and pepsinogen 2 (PG2), based on sandwich-type enzyme-linked immunosorbent assays (ELISAs) with horseradish peroxidase (HRP)-labeled antibody. To fabricate the electrochemical device for simultaneous analysis of several proteins, the electrode chip with eight electrode elements was assembled along with an antibody chip with eight cavities containing immobilized anti-PG1 or anti-PG2. The immunoreactions occurring in the cavities of the device were detected simultaneously by amperometry. The labeled HRP in the cavity in the presence of hydrogen peroxide catalyzed the oxidation of ferrocenemethanol (FMA) to FMA+, which was detected electrochemically by the electrode chip. The amperometric responses of respective cavities in the device increased with increasing concentration of PG1 or PG2 of 0-50 ng/ml, ensuring the simultaneous detection of PG1 and PG2. The detection limits for both PG1 and PG2 were 0.6 ng/ml (S/N=2). The electrode chip was recovered easily by disassembling the electrochemical device; thereby, it was used repeatedly, whereas the antibody chip was discarded. No marked decrease in electrochemical responses was detected after repeated use. Reuse of the electrode chip is beneficial to reduce costs of protein analysis.  相似文献   

7.
Background A growing number of patients with end-stage heart failure undergo implantation of ventricular assist devices as a bridge to heart transplantation. Objectives In this study we investigated whether functional and haemodynamic recovery after implantation is sufficient to warrant the use of them as long-term alternative to heart transplantation. Methods We compared peak VO2 of a group of patients three months after implantation of a ventricular assist device and three months after heart transplantation. Furthermore, we analysed the degree of haemodynamic recovery, by comparing plasma levels of BNP and creatinine before and after implantation of the device. Results After implantation of a ventricular assist device, exercise capacity improved considerably; three months after implantation peak VO2 was 20.0±4.9 ml/kg/min (52% of predicted for age and gender). After heart transplantation exercise capacity improved even further; 24.0±3.9 ml/ kg/min (62% of predicted for age and gender) (p<0.001). In the three months after implantation, BNP plasma levels decreased from 570±307 pmol/l to 31±25 pmol/l and creatinine levels decreased from 191±82 μmol/l to 82±25 μmol/l, indicating significant unloading of the ventricles and haemodynamic recovery. Conclusion With regard to functional and haemodynamic recovery, the effect of implantation of a ventricular assist device is sufficient to justify its use as an alternative to heart transplantation. (Neth Heart J 2008;16:41-6.)  相似文献   

8.
Organic electrochemical transistors (OECTs) based on poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS) with different gate electrodes, including graphite, Au and Pt electrode, etc., have been used as dopamine sensor for the first time. The sensitivity of the OECT to dopamine depends on its gate electrode and operation voltage. We find that the device with a Pt gate electrode characterized at the gate voltage of 0.6 V shows the highest sensitivity. The detection limit of the device to dopamine is lower than 5 nM, which is one order of magnitude better than a conventional electrochemical measurement with the same Pt electrode. It is expected that OECT is a good candidate for low cost and highly sensitive biosensor for the detection of dopamine.  相似文献   

9.
Deep brain stimulation (DBS) of the nucleus accumbens (NAc) is a potential remedial therapy for drug craving and relapse, but the mechanism is poorly understood. We investigated changes in neurotransmitter levels during high frequency stimulation (HFS) of the unilateral NAc on morphine-induced rats. Sixty adult Wistar rats were randomized into five groups: the control group (administration of saline), the morphine-only group (systematic administration of morphine without electrode implantation), the morphine-sham-stimulation group (systematic administration of morphine with electrode implantation but not given stimulation), the morphine-stimulation group (systematic administration of morphine with electrode implantation and stimulation) and the saline-stimulation group (administration of saline with electrode implantation and stimulation). The stimulation electrode was stereotaxically implanted into the core of unilateral NAc and microdialysis probes were unilaterally lowered into the ipsilateral ventral tegmental area (VTA), NAc, and ventral pallidum (VP). Samples from microdialysis probes in the ipsilateral VTA, NAc, and VP were analyzed for glutamate (Glu) and γ-aminobutyric acid (GABA) by high-performance liquid chromatography (HPLC). The levels of Glu were increased in the ipsilateral NAc and VP of morphine-only group versus control group, whereas Glu levels were not significantly changed in the ipsilateral VTA. Furthermore, the levels of GABA decreased significantly in the ipsilateral NAc, VP, and VTA of morphine-only group when compared with control group. The profiles of increased Glu and reduced GABA in morphine-induced rats suggest that the presence of increased excitatory neurotransmission in these brain regions. The concentrations of the Glu significantly decreased while the levels of GABA increased in ipsilateral VTA, NAc, and VP in the morphine-stimulation group compared with the morphine-only group. No significant changes were seen in the morphine-sham stimulation group compared with the morphine-only group. These findings indicated that unilateral NAc stimulation inhibits the morphine-induced rats associated hyperactivation of excitatory neurotransmission in the mesocorticolimbic reward circuit.  相似文献   

10.
We report the first implantation of a percutaneous left ventricular partitioning device in the Netherlands. This device is developed for patients with chronic heart failure due to a left ventricular apical aneurysm caused by an anterior myocardial infarction.  相似文献   

11.
A nerve clamp electrode was developed to indirectly stimulate skeletal muscle innervated by α motor neurons as an alternative to conventional electrodes. The stimulating electrode device consists of a spring coil-activated nerve clamp mounted inside a 1-mL syringe barrel. Supramaximal pulses were generated by a Grass stimulator and delivered to the nerve segment via the nerve clamp electrode. The salient feature of the electrode is its ability to produce muscle contractions indirectly through stimulation of the attached nerve. Indirect muscle stimulation is critical for studying the paralytic actions of presynaptic-acting toxins such as botulinum neurotoxins (BoNT), a potent inhibitor of acetylcholine (ACh) release from α motor neurons. This device enables stimulation of muscle contraction indirectly as opposed to contraction from direct muscle stimulation. The electrode is able to stimulate indirect muscle contraction when tested on ex vivo preparations from rodent phrenic nerve-hemidiaphragm muscle in similar fashion to conventional electrodes. In addition, the electrode stimulated external intercostal nerve-muscle preparations. This was confirmed after applying BoNT serotype A, a potent inhibitor of ACh release, to induce muscle paralysis. Alternative methods, including suction and bipolar loop electrodes, were unsuccessful in stimulating indirect muscle contraction. Therefore, this novel electrode is useful for physiological assessment of nerve agents and presynaptic actions of toxins that cause muscle paralysis. This electrode is useful for stimulating nerve-muscle preparations for which the length of nerve is a concern.  相似文献   

12.
对吸附式电极记录装置的技术改进   总被引:1,自引:0,他引:1  
本文介绍一种用吸附式电极记录合体细胞组织生物电位的改进装置。它的特点是在建造负压的注射器和吸附式电极之间设置一分离的小室。这一小室既保障了放大器与实验标本之间的电路连系,又可直接放置在实验标本附近,负压由改进的注射器经过充有空气的塑料管抽吸,注射器可以放在任何方便的位置上。该方法在记录小动物,如蜗牛、青蛙、等的心脏、消化道等组织器官的生物电位时都能获得比较理想的效果,对研究小动物合体细胞组织的正常机能及药物作用等都具有较好的适用价值,并具有定位准确、操作方便的优点。  相似文献   

13.
In vivo electrophysiological recordings in the awake, behaving animal provide a powerful method for understanding neural signaling at the single-cell level. The technique allows experimenters to examine temporally and regionally specific firing patterns in order to correlate recorded action potentials with ongoing behavior. Moreover, single-unit recordings can be combined with a plethora of other techniques in order to produce comprehensive explanations of neural function. In this article, we describe the anesthesia and preparation for microwire implantation. Subsequently, we enumerate the necessary equipment and surgical steps to accurately insert a microwire array into a target structure. Lastly, we briefly describe the equipment used to record from each individual electrode in the array. The fixed microwire arrays described are well-suited for chronic implantation and allow for longitudinal recordings of neural data in almost any behavioral preparation. We discuss tracing electrode tracks to triangulate microwire positions as well as ways to combine microwire implantation with immunohistochemical techniques in order to increase the anatomical specificity of recorded results.  相似文献   

14.
Intracranial electrocortical recording and stimulation can provide unique knowledge about functional brain anatomy in patients undergoing brain surgery. This approach is commonly used in the treatment of medically refractory epilepsy. However, it can be very difficult to integrate the results of cortical recordings with other brain mapping modalities, particularly functional magnetic resonance imaging (fMRI). The ability to integrate imaging and electrophysiological information with simultaneous subdural electrocortical recording/stimulation and fMRI could offer significant insight for cognitive and systems neuroscience as well as for clinical neurology, particularly for patients with epilepsy or functional disorders. However, standard subdural electrodes cause significant artifact in MRI images, and concerns about risks such as cortical heating have generally precluded obtaining MRI in patients with implanted electrodes. We propose an electrode set based on polymer thick film organic substrate (PTFOS), an organic absorbable, flexible and stretchable electrode grid for intracranial use. These new types of MRI transparent intracranial electrodes are based on nano-particle ink technology that builds on our earlier development of an EEG/fMRI electrode set for scalp recording. The development of MRI-compatible recording/stimulation electrodes with a very thin profile could allow functional mapping at the individual subject level of the underlying feedback and feed forward networks. The thin flexible substrate would allow the electrodes to optimally contact the convoluted brain surface. Performance properties of the PTFOS were assessed by MRI measurements, finite difference time domain (FDTD) simulations, micro-volt recording, and injecting currents using standard electrocortical stimulation in phantoms. In contrast to the large artifacts exhibited with standard electrode sets, the PTFOS exhibited no artifact due to the reduced amount of metal and conductivity of the electrode/trace ink and had similar electrical properties to a standard subdural electrode set. The enhanced image quality could enable routine MRI exams of patients with intracranial electrode implantation and could also lead to chronic implantation solutions.  相似文献   

15.
Kindling is a chronic model of epilepsy characterized by a progressive increase in response to the same regularly applied stimulus. The biological basis of the kindling phenomenon requires to be determined, but several studies indicate that alterations in amino acidergic neurotransmission may be involved. In the present experiments, levels of glutamate, aspartate, GABA, glycine, and taurine were determined in 12 brain regions by HPLC in 3 groups of animals: (a) a group which was kindled via electrical stimulation of intraamygdala electrodes and was sacrificed 36 days after the last fully kindled seizure for neurochemical determinations; (b) a group of implanted but nonstimulated rats (surgical control group) in which neurochemical measurements were done at the same time after electrode implantation as the kindled group, and (c) a group of non-implanted, naive control rats. Compared to surgical controls, kindling induced a significant reduction of glutamate, GABA, and taurine in the brain stem (pons/medulla), whereas no differences between both groups were found in any of the other regions. However, both electrode-implanted groups differed significantly from non-implanted naive rats in several regions, indicating that electrode-implantation per se induced long-lasting alterations in transmitter amino acids. The most striking difference to naive controls was an increase of glycine levels in several regions in which this amino acid is known to potentiate glutamatergic transmission. In order to examine the functional consequences of prolonged electrode implantation, seizure thresholds were determined in groups of rats with short and prolonged electrode implantation. Data from these experiments indicated that prolonged electrode implantation per se induces pro-kindling effects, i.e. a dramatic decrease of seizure threshold. The data of this study thus demonstrate that the choice of adequate controls is critical in neurochemical and functional studies on the kindling phenomenon.  相似文献   

16.
Extensive clinical experience has demonstrated that implantable cardiac pacemakers are safe and effective mechanisms for controlling symptoms and preventing the hazards of third degree heart block with Stokes-Adams syncope. Medical management of this disease does not provide reliable protection and life expectancy averages about two years after diagnosis. Hence the negligible surgical morbidity and mortality associated with pacemaker implantation justifies broad indications to implant one of the four commercially available battery-powered units.Elective implantation of a pacemaker should be considered in patients with persistent third degree heart block who have had: One or more episodes of Stokes-Adams syncope; surgical injury to the conduction system, regardless of syncopal attacks; evidence of low cardiac output with cardiomegaly secondary to bradycardia. Few if any other cardiac arrythmias are satisfactorily controlled by an electrical pacemaker.Emergency pacemaker control is obviously necessary for patients developing intractable or recurrent bouts of asystole. During the interval until an implantable unit can be obtained and sterilized, the patient may be controlled by intravenous isoproterenol or by an external pacemaker attached to a transvenous catheter electrode, a precordial skin electrode or a percutaneous myocardial wire electrode.  相似文献   

17.
A D Sharma  G Guiraudon  G J Klein  R Yee 《CMAJ》1987,137(9):809-815
The automatic implantable cardioverter/defibrillator is a device that can be implanted in patients for treatment of recurrent ventricular tachycardia and ventricular fibrillation. It was recently approved for clinical use in Canada. The authors describe their experience with 12 patients (mean age 51.3 years) who underwent implantation of a defibrillator. All 12 patients had a history of documented ventricular fibrillation, which was idiopathic in 3 and due to ischemic heart disease in 9. Electrophysiologic testing revealed inducible ventricular tachycardia or ventricular fibrillation in 8 of the 10 patients tested. An important criterion for selection for implantation was failure of pharmacologic therapy to suppress ventricular arrhythmias induced during electrophysiologic testing. Of the 12 patients, 1 died within 24 hours after implantation. During a mean follow-up period of 15.5 months there were no further deaths. All the surviving patients expressed satisfaction with the device; five of the seven under the age of 60 years have returned to work, and one has returned to school. This initial favourable experience with the automatic implantable cardioverter/defibrillator suggests that future increases in the availability of the device and improvements in its function will lead to much more widespread use, as the population of patients at risk of sudden cardiac death is large.  相似文献   

18.
A pacing electrode with a porous surface saturated with glucocorticoids has been designed in order to diminish the pacing threshold of the heart. The data obtained in animal studies show that saturation of the electrode with dexamethasone before implantation significantly reduces the pacing threshold.  相似文献   

19.
Biomechanics and Modeling in Mechanobiology - Studying the insertion process of cochlear implant (CI) electrode array (EA) is important to ensure successful, sufficient, and safe implantation. A...  相似文献   

20.
An electromyogram-recording electrode is described that makes it possible to record separately the electrical signals generated within two closely approximated muscle layers. The device consists of two bipolar wire hook electrodes embedded in opposite faces of a thin laminated plastic wafer. The middle lamina of the wafer is a sheet of metal foil that shields the electrical field on one side of the wafer from the bipolar electrode on the other side. The device was tested by inserting it from the inside of the chest wall between the internal and external intercostal muscle layers. Signals from the two muscle layers were clearly separated. Single motor unit spikes were attenuated by factors ranging from 41 to 2.4. The device can be implanted with minimal trauma to surrounding muscles and is suitable for chronic animal experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号