首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and sensitive method for determination of the N-glucuronidation activity of mouse, rat, and human liver microsomes toward the carcinogenic arylamine 4-aminobiphenyl (4-ABP) using high-performance liquid chromatography with ultraviolet detection has been developed. The method uses chemically synthesized 4-ABP-N-glucuronide (4-ABP-G) as a standard for method validation. Validation was done with respect to specificity, linearity, precision, accuracy, and lower limits of detection. The method was specific since there were no interference peaks from the reaction matrix. The calibration curve for 4-ABP-G was linear from 50 to 5000 pmol/200 microl with R2=0.999. The newly developed method has good precision and accuracy. The intra- and interday precisions were less than 5 and 10%, respectively, and the highest values for intra- and interday accuracies were -4.6 and -12%, respectively. The lower limit of detection was 10 pmol/200 microl. The developed method was used to determine the glucuronidation activity of mouse, rat, and human liver microsomes. Human liver microsomes were the most active in 4-ABP glucuronidation (344.1 pmol/min/mg) followed by rats (30.6 pmol/min/mg) and then mice (12.3 pmol/min/mg). Human UGT1A4 supersomes were much more active than UGT1A9 (184.4 mol/min/mg versus 25.2 mol/min/mg). These results are consistent with those of earlier studies that used the radioactive [C14]UDPGA.  相似文献   

2.
A method for the determination of S-d-lactoylglutathione (SLG), an intermediate metabolite of the glyoxalase system, in rat blood is described. After hemolysis and deproteinization of 30 microl of rat blood, SLG in the blood was determined by a column-switching HPLC system with precolumn fluorescence derivatization with a fluorogenic reagent, 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). Calibration curves for the determination of SLG showed a good linearity (r2 > 0.999) over the range of 20-100 pmol SLG spiked in rat blood samples. The accuracy was in the range of 97-104% (20-100 pmol SLG spiked in rat blood sample, N = 4). The detection limit was 8.12 fmol, and the quantitation limit was 27.07 fmol, respectively. The intra- and interday coefficients of variance were 4.63% (N = 5) and 9.98% (N = 5), respectively. The concentrations of SLG in whole blood from male Wistar-Kyoto rats (12 weeks old) were 3.48+/-0.78 microM (N = 4, mean+/-SE). In streptozotocin-induced diabetic rats, the concentration of SLG was significantly increased, approx 5-fold, compared with normal rats, suggesting that the metabolic flux of the glyoxalase system increases in red blood cells during hyperglycemia.  相似文献   

3.
Valproyl taurinamides are a novel group of compounds that possess anticonvulsant activity. In this study a gas chromatographic micromethod was developed for the quantification of selected valproyl taurinamides and some of their metabolites in biological samples. Valproyl taurinamide (VTD), N-methyl valproyl taurinamide (M-VTD), N,N-dimethyl valproyl taurinamide (DM-VTD) and N-isopropyl valproyl taurinamide (I-VTD) were analyzed in mouse and dog plasma and in dog urine using gas chromatography. Flame ionization detection and mass spectrometric detection were compared. The plasma samples were prepared by solid-phase extraction using C(18) cartridges. The urine samples were prepared by liquid-liquid extraction. The sample volume used was 100 microl of dog plasma, 50 microl of mouse plasma and 20 microl of dog or mouse urine. The quantification range of the method was 1.5-50 mg/l in dog plasma (VTD only), 2.5-250 mg/l in mouse plasma (0.7-90 pmol injected) and 0.04-2 mg/ml in dog urine (VTD only). The inter-day precision in plasma and urine samples was around 10% for all quantified concentrations except LOQ (15-20%). The accuracy for all four compounds was between 90 and 110% within the entire concentration range. The developed method was suitable for quantification of a series of CNS-active valproyl taurineamide derivatives in biological samples at relevant in vivo concentrations.  相似文献   

4.
A fully automated semi-microbore high performance liquid chromatographic (HPLC) method with column-switching using UV detection was developed for the determination of glimepiride from human plasma samples. Plasma sample (900 microl) was deproteinated and extracted with ethanol and acetonitrile. The extract (70 microl) was directly injected into a Capcell Pak MF Ph-1 pre-column where the primary separation occurred to remove proteins and retain drugs using a mixture of acetonitrile and 10mM phosphate buffer (pH 2.18) (20:80, v/v). The analytes were transferred from the pre-column to an intermediate column using a switching valve and then subsequently separated on an analytical column and monitored with UV detection at 228 nm. Glimepiride was eluted with retention time 34.9 min without interference of endogenous substance from plasma. The limit of quantification (LOQ) was 10 ng/ml for glimepiride. The calibration curves were linear over the concentration range of 10-400 ng/ml (r(2) = 0.9997). Moreover, inter- and intra-day precisions of the method were less than 15% and accuracies were higher than 99%. The developed method was successfully applied for the quantification of glimepiride in human plasma and was used to support a human pharmacokinetic study following a single oral administration of 2 mg glimepiride.  相似文献   

5.
A sensitive HPLC method has been developed for the assay of imatinib in human plasma, by off-line solid-phase extraction followed by HPLC coupled with UV-Diode Array Detection. Plasma (750 microl), with clozapine added as internal standard, is diluted 3 + 1 with water and subjected to a solid-phase extraction on a C18 cartridge. After matrix components elimination with 2000 microl of water (in two aliquots of 1000 microl), imatinib is eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 180 microl 50% methanol. A 50 microl volume is injected onto a Nucleosil 100-5 microm C18 AB column. Imatinib is analyzed using a gradient elution program with solvent mixture constituted of methanol and water containing both 0.05% ammonium acetate. Imatinib is detected by UV at 261 nm. The calibration curves are linear between 0.1 and 10 microg/ml. The limit of quantification and detection are 0.05 and 0.01 microg/ml, respectively. The mean absolute recovery of imatinib is 96%. The method is precise with mean inter-day CVs within 1.1-2.4%, and accurate (range of inter-day deviations -0.6 to +0.7%). The method has been validated and is currently being applied in a clinical study assessing the imatinib plasma concentration variability in a population of chronic myeloid leukemia- and gastro-intestinal stromal tumor-patients.  相似文献   

6.
A bioanalytical method for the analysis of artesunate and its metabolite dihydroartemisinin in human plasma using high throughput solid-phase extraction in the 96-wellplate format and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. The method was validated according to published FDA guidelines and showed excellent performance. The within-day and between-day precisions expressed as RSD, were lower than 7% at all tested concentrations including the lower limit of quantification. Using 50 microl plasma the calibration range was 1.19-728 ng/ml with a limit of detection at 0.5 ng/ml for artesunate and 1.96-2500 ng/ml with a limit of detection at 0.6 ng/ml for dihydroartemisinin. Using 250 microl of plasma sample the lower limit of quantification was decreased to 0.119 ng/ml for artesunate and 0.196 ng/ml dihydroartemisinin. Validation of over-curve samples in plasma ensured that accurate estimation would be possible with dilution if samples went outside the calibration range. The method was free from matrix effects as demonstrated both graphically and quantitatively.  相似文献   

7.
8.
A reversed-phase high-performance liquid chromatographic (HPLC) using ultraviolet (UV) absorbance detection method for simultaneous determination of clofibrate (I) and its major metabolite clofibric acid (II) in human plasma has been developed to support a clinical study. I, II and internal standard (I.S., III) are isolated from human plasma by 96-well solid-phase extraction (SPE) C(18)z.ccirf;AR plate and quantified by direct injection of the SPE eluent onto the HPLC with UV detection wavelength at 230 nm. Two chromatographic methods, isocratic and step gradient, have been validated from 1.0 to 100.0 microg/ml and successfully applied to plasma sample analysis for a clinical study. The lower limit of quantitation (LLOQ) is 1.0 microg/ml for both I and II when 500 microl plasma sample is processed. Sample collection and preparation is conducted at 5 degrees C to minimize the hydrolysis of I to II in human plasma.  相似文献   

9.
An HPLC method was developed for the determination of a new oxazolidinone, DA-7867 (I), in human plasma and urine and in rat tissue homogenates. To 100 microl of biological sample, 300 microl acetonitrile and 50 microl methanol containing 10 microg/ml DA-7858 (the internal standard) were added. After vortex-mixing and centrifugation, the supernatant was evaporated under a gentle stream of nitrogen. The residue was reconstituted in 100 microl of the mobile phase and a 50-microl aliquot was injected directly onto the reversed-phase (C(18)) column. The mobile phase, 20 mM KH2PO4:acetonitrile (75:25, v/v) was run at a flow rate of 1.5 ml/min and the column effluent was monitored by a UV detector set at 300 nm. The retention times of I and DA-7858 were approximately 6.5 and 8.7 min, respectively. The detection limits of I in human plasma and urine and in rat tissue homogenates were 20, 20, and 50 ng/ml, respectively.  相似文献   

10.
A simple and sensitive method for the detection of 3-deoxyglucosone was developed using oxidation with crude oxoaldehyde dehydrogenase to 2-keto-3-deoxygluconic acid followed by high-performance liquid chromatography (HPLC). Oxoaldehyde dehydrogenase was prepared from rabbit liver and partially characterized. 2-Keto-3-deoxygluconic acid produced from 3-deoxyglucosone by oxoaldehyde dehydrogenase was derivatized with 1,2-diamino-4,5-methylenedioxybenzene, and the fluorescent products were detected and quantitated by HPLC using a solvent containing borate. In the presence of borate, 2-keto-3-deoxygluconic acid was completely separated from N-acetylneuraminic acid. The detection limit of 3-deoxyglucosone was 2.5 pmol/injection (10 μl) at a signal-to-noise ratio of 3. This method was used to confirm the inhibitory effect of aminoguanidine on glycation.  相似文献   

11.
Assay of coenzyme Q(10) in plasma by a single dilution step   总被引:2,自引:0,他引:2  
A new method is described for determining coenzyme Q(10) (CoQ(10)) in plasma. The method is based on oxidation of CoQ(10) in the sample by treating it with para-benzoquinone followed by extraction with 1-propanol and direct injection into the HPLC apparatus. This method achieves a linear detector response for peak area measurements over the concentration range of 0.05-3.47 microM. Diode array analysis of the peak was consistent with CoQ(10) spectrum. Supplementation of the samples with known amounts of CoQ(10) yielded a quantitative recovery of 96-98.5%; the method showed a level of quantitation of 1.23 nmol per HPLC injection (200 microl of propanol extract containing 33.3 microl of plasma). A correlation of r = 0.99 (P < 0.0001) was found with a reference electrochemical detection method. Within run precision showed a CV% of 1.6 for samples approaching normal values (1.02 microM). Day-to-day precision was also close to 2%.  相似文献   

12.
An HPLC method for detecting nitrite in microdialysis samples obtained from activated RAW 264.7 macrophages in cell culture has been developed. Nitrite was quantified using a pre-column derivatization with 2,4-dinitrophenylhydrazine (2,4-DNPH) followed by HPLC-UV analysis of the azide product. For dialysates, the detection limit of nitrite was 750 nM and the quantitation limit was 2.5 microM. The microdialysis relative recovery of nitrite in the macrophage cell culture medium was determined to be 86+/-2% (n=3) at a flow rate of 0.7 microl/min. Nitrite produced from activated macrophages was measured immediately after lipopolysaccharide (LPS) stimulation using microdialysis sampling.  相似文献   

13.
Two different assays have been developed and used in order to investigate the optimal conditions for derivatization and detection of acid beta-N-methyl-amino-L-alanine (BMAA) in a cyanobacterial sample. BMAA was extracted from cyanobacterial cultures both from the cytosolic ("free") fraction and in the precipitated ("protein") fraction using a newly developed extraction scheme and the sample matrix was standardized according to protein concentration to ensure the highest possible derivative yield. A rapid and sensitive HPLC method for fluorescence detection of the non-protein amino acid BMAA in cyanobacteria, utilizing the Waters AccQ-Tag chemistry and Chromolith Performance RP-18e columns was developed. Using this new method and utilizing a different buffer system and column than that recommended by Waters, we decreased the time between injections by 75%. The limit of quantification was determined to be 12 nmol and limit of detection as 120 fmol. The linear range was in the range of 8.5 nmol-84 pmol. Accuracy and precision were well within FDA guidelines for bioanalysis.  相似文献   

14.
A simple and sensitive high-performance liquid chromatographic (HPLC) method is established for the trace determination of tobramycin in human plasma by derivatization. The method is based on the chemical derivatization of aminoglycoside antibiotic, tobramycin in human plasma, with 1-naphthyl isothiocyanate (NITC) in pyridine at 70 degrees C. After derivatization reaction, a methylamine/acetonitrile solution was added to the reaction mixture to eliminate the excess derivatizing agent and shorten the analysis time. The resulting derivative was separated using a Purospher STAR RP-18e column and a water-acetonitrile (50:50, v/v) mobile phase (detection at 230 nm). Optimization conditions for the derivatization of tobramycin were investigated by HPLC. The linear range for the quantitation of tobramycin in spiked plasma was over 0.93-9.34 mg/l; the detection limit (signal-to-noise ratio=3; injection volume, 10 microl) was about 0.23 mg/l. The relative standard deviation was less than 2.1% for intra-day assay (n=6) and 5.2% for inter-day assay (n=6) and relative recoveries were found greater than 99%.  相似文献   

15.
The first method using high-performance liquid chromatography (HPLC) has been developed for the determination of trans-resveratrol in human plasma. The method involves a liquid–liquid extraction followed by reversed-phase HPLC with UV detection. The detection limit of trans-resveratrol in human plasma was 5.0 ng/ml. Standard curves are linear over the concentration range of 5.0–5000.0 ng/ml. Intra-assay variability ranged from 1.9 to 3.7% and inter-assay variability ranged from 2.5 to 4.0% at the concentration range of 15.0–4000.0 ng/ml.  相似文献   

16.
Cyclizine is a piperazine derivative with anti-emetic activity that is useful in the prevention and treatment of nausea and vomiting associated with motion sickness. A liquid chromatography-tandem mass spectrometry (LC-MS-MS) method is presented for the quantitation of cyclizine in serum. Sample pretreatment involved liquid-liquid extraction of 200 microl of serum with dichloromethane after the addition of 100 microl each of ammonium hydroxide and internal standard solutions. The extracts were analyzed by HPLC on a Luna C18 reversed-phase column and an ion-trap mass spectrometer with an electrospray interface. A limit of detection of 1 ng/ml was determined which allowed for the reliable measurement of cyclizine in the serum of human subjects. The method was found to be linear over the calibration range of 2.5-100 ng/ml. The applicability of this method was demonstrated by the analysis of serum obtained from a human volunteer following administration of a single 50 mg cyclizine hydrochloride tablet. The reported method was observed to have the necessary sensitivity, selectivity, precision and accuracy for monitoring cyclizine concentrations in human subjects following oral administration.  相似文献   

17.
A method for the determination of N-glucuronidation of nicotine and cotinine in human liver microsomes by high-performance liquid chromatography was developed. Nicotine or cotinine was incubated with human liver microsomes and UDP-glucuronic acid in a 200-microl incubation mixture. The nicotine N-glucuronide (Nic-glu) and cotinine N-glucuronide (Cot-glu) formed were analyzed by ion-pair chromatography with a C-18 column. The sensitivity of quantification at 260 nm absorption was improved by using a noise-base clean Uni-3, and the limit of quantification was 10 pmol/200 microl mixture for both Nic-glu and Cot-glu. Linear standard curves were obtained within the concentration ranges 25-1000 pmol/200 microl mixture for Nic-glu and 100-5000 pmol/200 microl mixture for Cot-glu. The intraassay precision and accuracy were < or =11.1% coefficient of variation (CV) and 97.5-106.6% for Nic-glu and < or =4.6% CV and 96.7-100.4% for Cot-glu. The interassay precision and accuracy were < or =7.2% CV and 98.2-106.1% for Nic-glu and < or =4.6% CV and 96.8-99.3% for Cot-glu. This is the first report of the in vitro determination of Nic-glu and Cot-glu in human liver microsomes. Furthermore, this highly sensitive HPLC method can be used for the determination of Nic-glu and Cot-glu in biological specimens in vivo.  相似文献   

18.
A reversed-phase high-performance liquid chromatographic (HPLC) method with ultraviolet (UV) detection was developed and validated for the quantification of 6-deoxy-6-demethyl-4-dedimethylamino-tetracycline (COL-3), a matrix metalloproteinase (MMPs) inhibitor, in rat serum. This simple, sensitive, rapid and reproducible assay involved a preliminary serum deproteinization by adding a mixture of acetonitrile-methanol-0.5 M oxalic acid (70:20:10 (v/v)), as the combined precipitant and metal blocking agent, into serum samples (2:1 (v/v)). An aliquot (20 microl) of the supernatant was injected into the HPLC system linked to a Waters XTerra RP(18) column (150 mm x 4.6 mm i.d., particle size 5 microm). The compound was eluted by a mixture of acetonitrile-methanol-0.01 M oxalic acid (40:10:50 (v/v), pH 2.00), as the mobile phase, and detected at the wavelength of 350 nm. The total running time was 10 min. The low and high concentration calibration curves were linear in the range of 50-1200 ng/ml and 1200-12,000 ng/ml, respectively. The intra- and inter-day coefficients of variation at three quality control concentrations of 100, 1200, and 12,000 ng/ml were all less than 6%, while the percent error ranged from -2.5 to 6.6%. The limit of quantitation (LOQ) for COL-3 in serum was 50 ng/ml. This assay was successfully employed to study the serum concentration-time profiles of COL-3 after its intravenous and oral administration in rats. The method with some minor modifications in sample pretreatment was also applicable to the determination of the concentrations of COL-3 in rat bile, urine and feces.  相似文献   

19.
A high performance liquid chromatography (HPLC) method using fluorescence detection to determine 3-amino-5-mercapto-1,2,4-triazole (AMT) levels in serum has been developed. Sample preparation involved treatment with tributylphosphine (TBP) to reduce disulfides formed during storage, precipitation of proteins with acetonitrile (ACN), and precolumn derivatization using the thiol reactive fluorescent probe monobromobimane (MBB). The conjugate (AMT-MBB) was resolved by gradient elution from a C(18) reversed-phase column. The assay method was linear over a concentration range of 0.78-50 microg/ml and had a limit of detection (LOD) of 0.05 microg/ml AMT (10 microl injection). This method provides a sensitive and specific tool for the determination of AMT in serum and may have potential industrial hygiene application.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号