首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been recently established as a powerful tool for the analysis of biomolecules. Here, MALDI-TOF MS was used for the detection of (poly-)phosphoinositides (PPI). PPI possess higher molecular weights than other phospholipids and a high phosphorylation-dependent negative charge. Both features affect the MALDI detection limits expressed as the minimum of analyte on the sample plate resulting in a signal-to-noise-ratio of S/N=5. Using 2,5-dihydroxybenzoic acid (DHB) as matrix the detection limit for phosphatidylinositol (PI) is seven times higher than for phosphatidylcholine (PC) and further increases with increasing phosphorylation or in mixtures with other well-detectable phospholipids. For phosphatidylinositol-tris-phosphate (PIP3) in a mixture with PC, the limit is about 20 times higher than for PI. The consequences for the experimental conditions are discussed. It is advisable to pre-separate PPI from biological lipid mixtures prior to the application of MALDI-TOF MS.  相似文献   

2.
Demonstration of the abiotic polymerization of ribonucleotides under conditions consistent with conditions that may have existed on the prebiotic Earth is an important goal in “RNA world” research. Recent reports of abiotic RNA polymerization with and without catalysis rely on techniques such as HPLC, gel electrophoresis, and MALDI-TOF MS to analyze the reaction products. It is essential to understand the limitations of these techniques in order to accurately interpret the results of these analyses. In particular, techniques that rely on mass for peak identification may not be able to distinguish between a single, linear RNA oligomer and stable aggregates of smaller linear and/or cyclic RNA molecules. In the case of MALDI-TOF MS, additional complications may arise from formation of salt adducts and MALDI matrix complexes. This is especially true for abiotic RNA polymerization reactions because the concentration of longer RNA chains can be quite low and RNA, as a polyelectrolyte, is highly susceptible to adduct formation and aggregation. Here we focus on MALDI-TOF MS analysis of abiotic polymerization products of imidazole-activated AMP in the presence and absence of montmorillonite clay as a catalyst. A low molecular weight oligonucleotide standard designed for use in MALDI-TOF MS and a 3′-5′ polyadenosine monophosphate reference standard were also run for comparison and calibration. Clay-catalyzed reaction products of activated GMP and UMP were also examined. The results illustrate the ambiguities associated with assignment of m/z values in MALDI mass spectra and the need for accurate calibration of mass spectra and careful sample preparation to minimize the formation of adducts and other complications arising from the MALDI process.  相似文献   

3.
Several phosphatidylcholines (PC) and a phosphatidylethanolamine (PE) were subjected to liquid ionization (LI) mass spectrometry, in which a sample is ionized through energy transfer from metastable argon atoms under atmospheric pressure. Commercially available and synthesized, saturated or unsaturated fatty acid containing phospholipids and their mixtures were studied. A sample either as a concentrated chloroform-methanol solution or with glycerol (matrix) gave characteristic peaks such as MH+ and four fragment ions. One of the fragment ions (e.g., m/z 551 of PC 16:0, 16:0) containing both fatty acid residues has been commonly observed with other ionization methods such as CI, FD, and FAB, but the other fragment ions have not been observed in other mass spectra with one exception on desorption CI. Ions b and d (e.g., m/z 464 and 328, respectively, for PC 16:0, 16:0) contain one fatty acyl residue and the other ion containing the phosphorylcholine moiety appears at m/z 196 for PC. Thus the masses of the MH+ ion and these fragment ions provide useful structural information even in the case of a mixture. The ion b (e.g., m/z 488 of PC 18:0, 18:2) observed during an early period of heating was formed mainly by the loss of one acyl group at sn-1 of the glycerol backbone and thus may be used to differentiate the positional specificities of the constituent fatty acids. The temperature of the sample, however, should be controlled precisely, because it has a significant effect on the mass spectrum. The present method (LI) also provided useful information for a mixture of PC and PE.  相似文献   

4.
Under the action of free-radical reaction initiators on membrane phospholipids, complex processes are taking place in both hydrophobic and hydrophilic parts of the phospholipids. Realization of these processes results in a mixture consisting of the initial lipids and their peroxidation and fragmentation products. Identification of compounds in such mixtures requires analytical methods of high sensitivity, reproducibility and accuracy to be applied. These properties are characteristic of the matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) method. In the studies of radiation-induced free-radical transformations of phosphatidylglycerol, the MALDI-TOF MS in combination with thin layer chromatography (TLC) has been shown to be able to detect and identify products of free-radical transformations taking place in both hydrophilic and hydrophobic parts of the phospholipid. Thus, the MALDI-TOF MS can serve as a suitable analytical tool to investigate free-radical transformations of lipids.  相似文献   

5.
The interest in the analysis of lipids and phospholipids is continuously increasing due to the importance of these molecules in biochemistry (e.g. in the context of biomembranes and lipid second messengers) as well as in industry. Unfortunately, commonly used methods of lipid analysis are often time-consuming and tedious because they include previous separation and/or derivatization steps. With the development of "soft-ionization techniques" like electrospray ionization (ESI) or matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF), mass spectrometry became also applicable to lipid analysis. The aim of this review is to summarize so far available experiences in MALDI-TOF mass spectrometric analysis of lipids. It will be shown that MALDI-TOF MS can be applied to all known lipid classes and the characteristics of individual lipids will be discussed. Additionally, some selected applications in medicine and biology, e.g. mixture analysis, cell and tissue analysis and the determination of enzyme activities will be described. Advantages and disadvantages of MALDI-TOF MS in comparison to other established lipid analysis methods will be also discussed.  相似文献   

6.
Different methods were established for monitoring the phospholipase A(2)(PLA(2)) activity but all of them are rather cumbersome and time consuming. In this paper we have investigated the suitability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the determination of the PLA(2) activity. Phosphatidylcholine (PC) was digested with pancreatic PLA(2) under different conditions, i.e., various Ca(2+), PC, and PLA(2) concentrations. The digestion products were analyzed by MALDI-TOF MS and the concentration of lysophosphatidylcholine (LPC)-generated upon PLA(2) digestion-was determined by the application of an internal standard (known concentration) and by a comparison of their signal-to-noise ratios. The results clearly demonstrate that the LPC concentration determined from the MALDI-TOF mass spectra correlates directly with the activity of the applied enzyme. Additionally, LPC concentration increased with an increase in Ca(2+), as well as in the PC concentration. A single MALDI-TOF mass spectrum provides immediate information on the digestion products as well as on the residual substrate without requirements for any previous derivatization. MALDI-TOF MS can be easily and simply applied for monitoring the PLA(2) activity and we assume that this method might also be useful for other types of phospholipases.  相似文献   

7.
The analysis of HDL and LDL is important for the further understanding of atherosclerosis because changes of the protein and lipid moieties occur under pathological conditions. Because destruction of lipids leads to the formation of well-defined products such as lysophospholipids or chlorohydrins, methods that allow their fast and reliable determination would be useful. In this study, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) was applied for the analysis of the lipid composition of human lipoproteins. These data were compared with high resolution (31)P-NMR spectroscopy. Differences between LDL and HDL in sphingomyelin and phosphatidylcholine content could be monitored by NMR and mass spectrometry, and differences with respect to the extraction efficiency were found by MALDI-TOF MS. Additionally, treatment of LDL with hypochlorite and phospholipase A(2) resulted in marked changes (formation of chlorohydrines and lysolipids). Lysophosphatidylcholines were detectable by both methods, whereas MALDI-TOF MS failed to detect chlorohydrines of phospholipids.We conclude that MALDI-TOF MS provides rapidly a reliable lipid profile of lipoproteins. However, a previous lipid separation must be performed to detect lipid oxidation products. NMR can be directly applied, but suffers from lower sensitivity, and provides only limited information on fatty acid composition.  相似文献   

8.
Despite the high sensitivity and relatively high tolerance for contaminants of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) there is often a need to purify and concentrate the sample solution, especially after in-gel digestion of proteins separated by two-dimensional gel electrophoresis (2-DE). A silicon microextraction chip (SMEC) for sample clean-up and trace enrichment of peptides was manufactured and investigated. The microchip structure was used to trap reversed-phase chromatography media (POROS R2 beads) that facilitates sample purification/enrichment of contaminated and dilute samples prior to the MALDI-TOF MS analysis. The validity of the SMEC sample preparation technique was successfully investigated by performing analysis on a 10 nM peptide mixture containing 2 m urea in 0.1 m phosphate-buffered saline with MALDI-TOF MS. It is demonstrated that the microchip sample clean-up and enrichment of peptides can facilitate identification of proteins from 2-DE separations. The microchip structure was also used to trap beads immobilized with trypsin, thereby effectively becoming a microreactor for enzymatic digestion of proteins. This microreactor was used to generate a peptide map from a 100 nM bovine serum albumin sample.  相似文献   

9.
Despite the high clinical relevance, only the cellular moiety of bronchoalveolar lavage (BAL) has been intensively investigated and is used for diagnosis purposes. On the other hand, the cell-free fluid is, by far, less characterized. Although this fluid represents a relatively simple mixture of only a few different phospholipids (mainly phosphatidylcholine, phosphatidylglycerol and cholesterol), methods for the routine analysis of these fluids are still lacking. In the present investigation we have applied, for the first time, MALDI-TOF mass spectrometry, as well as 31P NMR spectroscopy to the analysis of organic extracts of bronchoalveolar lavage fluids. BAL from different mammals (rat, minipig, rabbit and man) were investigated and, for means of comparison, organic extracts of lung tissue were also examined. Both applied methods provide fast and reliable information on the lipid composition of the bronchoalveolar lavage. However, despite of its comparably low sensitivity, 31P NMR spectroscopy detects all phospholipid species in a single experiment and with the same sensitivity, whereas MALDI-TOF fails in the detection of phosphatidylethanolamine in the presence of higher quantities of phosphatidylcholine. In contrast, MALDI-TOF mass spectrometry is more suitable for the detection of cholesterol and the determination of the fatty acid composition of the individual phospholipids, especially lysolipids. It will be shown that all BALs exhibit significant, species-dependent differences that mainly concern the content of phosphatidylglycerol and lyso-phosphatidylcholine. It is concluded that both methods are suitable tools in lipid research due to the (in comparison to alternative methods) simplicity of performance.  相似文献   

10.
Matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is increasingly used to characterize (phospho)lipids. However, quantitative MALDI data are often questioned because ion suppression may occur if mixtures are analyzed. Therefore, relative (but no absolute) data are normally derived from the MALDI mass spectra of lipid mixtures. We are particularly interested in the phosphatidylcholine/lysophosphatidylcholine (PC/LPC) ratio because it seems to represent a suitable measure of the inflammatory activity. In this study, different parameters affecting the achievable accuracy of the MALDI-TOF MS determination of the PC/LPC ratio are compared. It will be shown that particularly the applied laser fluence as well as the used solvents influence the accuracies. Using artificial lipid mixtures it will be demonstrated that the PC/LPC ratio can be determined with an accuracy of about ±10% making the MALDI assay comparable to established methods. Finally, it will be shown that the optimized conditions are also useful to determine the PC/LPC ratios in human seminal plasma.  相似文献   

11.
Current molecular methods to characterize microalgae are time-intensive and expensive. Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS) may represent a rapid and economical alternative approach. The objectives of this study were to determine whether MALDI-TOF MS can be used to: 1) differentiate microalgae at the species and strain levels and 2) characterize simple microalgal mixtures. A common protein extraction sample preparation method was used to facilitate rapid mass spectrometry-based analysis of 31 microalgae. Each yielded spectra containing between 6 and 56 peaks in the m/z 2,000 to 20,000 range. The taxonomic resolution of this approach appeared higher than that of 18S rDNA sequence analysis. For example, two strains of Scenedesmus acutus differed only by two 18S rDNA nucleotides, but yielded distinct MALDI-TOF mass spectra. Mixtures of two and three microalgae yielded relatively complex spectra that contained peaks associated with members of each mixture. Interestingly, though, mixture-specific peaks were observed at m/z 11,048 and 11,230. Our results suggest that MALDI-TOF MS affords rapid characterization of individual microalgae and simple microalgal mixtures.  相似文献   

12.
The analysis of beef lipids is normally based on chromatographic techniques and/or gas chromatography in combination with mass spectrometry (GC/MS). Modern techniques of soft-ionization MS were so far scarcely used to investigate the intact lipids in muscle tissues of beef. The objective of the study was to investigate whether matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) mass spectrometry and 31P nuclear magnetic resonance (NMR) spectroscopy are useful tools to study the intact lipid composition of beef. For the MALDI-TOF MS and 31P NMR investigations muscle samples were selected from a feeding experiment with German Simmental bulls fed different diets. Beside the triacylglycerols (TAGs), phosphatidylethanolamine (PE), phosphatidylcholine (PC) and phosphatidylinositol (PI) species the MALDI-TOF mass spectra of total muscle lipids gave also intense signals of cardiolipin (CL) species.The application of different matrix compounds, 2,5-dihydroxybenzoic acid (DHB) and 9-aminoacridine (9-AA), leads to completely different mass spectra: 9-AA is particularly useful for the detection of (polar) phospholipids, whereas apolar lipids, such as cholesterol and triacylglycerols, are exclusively detected if DHB is used. Finally, the quality of the negative ion mass spectra is much higher if 9-AA is used.  相似文献   

13.
A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based kinase assay using a peptide substrate tagged with a biotinyl group has been developed. The peptide moiety was designed to serve as an efficient substrate for calcium/calmodulin-dependent protein kinase II, based on the in vivo phosphorylation site of phosrestin I, a Drosophila homolog of arrestin. In the assay, the quantitative relationship was determined from the ratio of the peak areas between the two peaks respectively representing the unphosphorylated and the phosphorylated substrate. Attempts to assay phosphorylated peptides directly from the reaction mixture, gave inaccurate results because of the high noise level caused by the presence of salts and detergents. In contrast, after purifying the substrate peptides with the biotin affinity tag using streptavidin-coated magnetic beads, peak areas accurately represented the ratio between the unphosphorylated and phosphorylated peptide. By changing the substrate peptide to a peptide sequence that serves as a kinase substrate, it is expected that an efficient non-radioactive protein kinase assay using MALDI-TOF MS can be developed for any type of protein kinase. We call this technique "Affinity-Tagged Phosphorylation Assay by MALDI-TOF MS (ATPA-MALDI)." ATPA-MALDI should serve as a quick and efficient non-radioactive protein kinase assay by MALDI-TOF MS.  相似文献   

14.
Glycerophospholipids (GPs) that differ in the relative position of the two fatty acyl chains on the glycerol backbone (i.e., sn-positional isomers) can have distinct physicochemical properties. The unambiguous assignment of acyl chain position to an individual GP represents a significant analytical challenge. Here we describe a workflow where phosphatidylcholines (PCs) are subjected to ESI for characterization by a combination of differential mobility spectrometry and MS (DMS-MS). When infused as a mixture, ions formed from silver adduction of each phospholipid isomer {e.g., [PC (16:0/18:1) + Ag]+ and [PC (18:1/16:0) + Ag]+} are transmitted through the DMS device at discrete compensation voltages. Varying their relative amounts allows facile and unambiguous assignment of the sn-positions of the fatty acyl chains for each isomer. Integration of the well-resolved ion populations provides a rapid method (< 3 min) for relative quantification of these lipid isomers. The DMS-MS results show excellent agreement with established, but time-consuming, enzymatic approaches and also provide superior accuracy to methods that rely on MS alone. The advantages of this DMS-MS method in identification and quantification of GP isomer populations is demonstrated by direct analysis of complex biological extracts without any prior fractionation.  相似文献   

15.
Salamander large cells facilitated identification and localization of lipids by MALDI imaging mass spectrometry. Salamander retina lipid extract showed similarity with rodent retina lipid extract in phospholipid content and composition. Like rodent retina section, distinct layer distributions of phospholipids were observed in the salamander retina section. Phosphatidylcholines (PCs) composing saturated and monounsaturated fatty acids (PC 32:0, PC 32:1, and PC 34:1) were detected mainly in the outer and inner plexiform layers (OPL and IPL), whereas PCs containing polyunsaturated fatty acids (PC 36:4, PC 38:6, and PC 40:6) composed the inner segment (IS) and outer segment (OS). The presence of PCs containing polyunsaturated fatty acids in the OS layer implied that these phospholipids form flexible lipid bilayers, which facilitate phototransduction process occurring in the rhodopsin rich OS layer. Distinct distributions and relative signal intensities of phospholipids also indicated their relative abundance in a particular cell or a cell part. Using salamander large cells, a single cell level localization and identification of biomolecules could be achieved by MALDI imaging mass spectrometry.  相似文献   

16.
Using electrospray ionization tandem mass spectrometry (ESI-MS/MS) this study shows that the loss of glycerophospholipid (GPL) after chromatography was unevenly distributed across the GPL molecular species. Both TLC and HPLC caused a preferential loss of GPL with 0 to 3 double bonds: 20% and 7.2% for choline glycerophosphates (PC) and 19.7% and 7.5% for ethanolamine glycerophosphates (PE), respectively. A consequence of these losses was that GPLs containing fatty acids with four or more double bonds had a greater contribution to the total after chromatography. ESI-MS/MS analysis also showed that PC molecular species with four or more double bonds migrated at the front of the TLC band of PCs. GPLs extracted from TLC plates occasionally contained PCs that were smaller than those in the original extract. These low molecular mass PCs were easily reduced to alcohols and formed derivatives with 2,4-dinitrophenylhydrazine, suggesting that aldehydes were generated by the oxidation of unsaturated fatty acids. Directly analyzing lipid extracts by ESI-MS/MS without preliminary chromatographic separation gives an accurate distribution of GPL molecular species in lipid mixtures. However, the ionization of the phospholipids in the electrospray jet maximized at relatively low concentrations of GPL. There was a linear response between phospholipid mass and ion intensity for concentrations around 1-2 nmol/ml for both PC and PE. The total ion intensity continued to increase with concentrations above 1-2 nmol/ml, but the response was non-linear.  相似文献   

17.
In this study we demonstrated the combination of MALDI-TOF MS and TLC as a fast and powerful tool to investigate the phospholipid (PL) composition of organic extracts of bull spermatozoa. Since phosphatidylcholine (PC) is the dominant PL species, an adequate resolution of MALDI-TOF spectra for sphingomyelin (SM) or phosphatidylethanolamine (PE) was achieved only after previous PL separation by TLC. We found a poor diversity especially for PE and PC, mainly containing ether-linked fatty acids which were 1-palmityl-2-docosahexaenoyl-PL and the corresponding alkenyl-acyl compound (plasmalogen) 1-palmitenyl-2-docosahexaenoyl-PL. For PC, both lipids were quantified after phospholipase A2 digestion to represent 44.2 and 37.2%, respectively, of the total PC. In contrast, the diacyl-PC content of bull spermatozoa was comparatively low (18.6% of total PC). In the presence of trifluoroacetic acid (TFA), which is routinely added to the MALDI-TOF matrix to improve the signal to noise ratio, a high lysophospholipid (LPL) content was detected in the PL extracts of bull spermatozoa, whereas TLC did not reveal significant amounts of LPL. The TFA mediated hydrolysis of the acid-labile alkenyl-acyl PL to the corresponding LPL was shown to cause this discrepancy. This assumption was verified by analysing the PL composition by MALDI-TOF MS before and after (i) digestion of sperm cell lipids with phospholipase A2 and (ii) exposition of spermatozoa to HCl fumes. We conclude that the analysis of samples containing alkenyl-acyl-PL by MALDI-TOF has to be performed with great caution.  相似文献   

18.
19.
The formation of lysophosphatidylcholines from unsaturated phosphatidylcholines upon treatment with hypochlorous acid was evaluated by means of MALDI-TOF mass spectrometry and 31P NMR spectroscopy. With an increasing number of double bonds in a fatty acid residue, the yield of lysophosphatidylcholines with a saturated fatty acid residue increased considerably in comparison to the total amount of higher molecular weight products like chlorohydrins and glycols. High amounts of lysophosphatidylcholines were formed from phospholipids containing arachidonic or docosahexaenoic acid residues. In phospholipids with monounsaturated fatty acid residues, the position of the double bond did not influence the yield of lyso-products. Besides the exclusive formation of chlorohydrin and glycol, hypochlorous acid caused the cleavage of the unsaturated fatty acid residue independent of its location at the first or second position of the glycerol backbone. In contrast, strong alkaline conditions, i.e. saponification led also to a hydrolysis of the saturated fatty acid residue from phosphatidylcholines. It is concluded that both MALDI-TOF mass spectrometry and 31P NMR spectroscopy are able to detect the formation of lysophosphatidylcholines. We conclude also that the formation of lysophospholipids from unsaturated phosphatidylcholines by hypochlorous acid can be relevant in vivo under acute inflammatory conditions.  相似文献   

20.

Background

Protein histidine phosphatase (PHP) is an enzyme which removes phosphate groups from histidine residues. It was described for vertebrates in the year 2002. The recombinant human 16 kDa protein forms multimeric complexes in physiological buffer and in the gas phase. High-mass calibration in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has remained a problem due to the lack of suitable standards. Large proteins can hardly be freed of their substructural microheterogeneity by classical purification procedures so that their use as calibrants is limited. A small adduct-forming protein of validated quality is a valuable alternative for that purpose.

Methodology/Principal Findings

Three major PHP clusters of ∼113, 209 and >600 kDa were observed in gel filtration analysis. Re-chromatography of the monomer peak showed the same cluster distribution. The tendency to associate was detected also in MALDI-TOF MS measuring regular adducts up to 200 kDa.

Conclusions/Significance

PHP forms multimers consisting of up to more than 35 protein molecules. In MALDI-TOF MS it generates adduct ions every 16 kDa. The protein can be produced with high quality so that its use as calibration compound for high mass ranges above 100 kDa, where standards are difficult to obtain, is feasible.  相似文献   