首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this research was to develop a bolus-response method for the noninvasive determination of O3 distribution in the human lung. A previously developed O3 analyzer and bolus generator were incorporated in a computer-controlled inhalation system, and measurements of O3 absorption from inhaled 10-ml boluses with a peak O3 concentration of 4 ppm were carried out on nine previously unexposed healthy male subjects engaged in quiet oral breathing. The fraction of O3 absorbed during a single breath was measured over a range of airway penetrations from 20 to 200 ml, with inspiratory and expiratory flows fixed at a nominal value of 250 ml/s. The resulting data indicated that 50% of the inhaled O3 was absorbed at a penetration of 70 ml, which roughly corresponds to the upper airways, and essentially complete absorption occurred at a penetration of 180 ml, which roughly corresponds to the 16th airway generation, the beginning of the proximal alveolar region. This compares favorably with the results of direct-sampling methods, which indicated that 40.4% of continuously inhaled O3 is removed by the extrathoracic airways (Gerrity et al. J. Appl. Physiol. 65: 393-400, 1988). The computation of an absorption rate constant, Ka, revealed that the efficiency of O3 uptake increased with longitudinal position throughout most of the conducting airways but began to fall off at a penetration of 160 ml.  相似文献   

2.
The interaction between CO2 and negative pressure pulses on breathing pattern was investigated in 10 anesthetized, spontaneously breathing rabbits. The upper airway was functionally isolated into a closed system. A servo-respirator triggered by the inspiratory activity of the diaphragm was used to apply pressure pulses of -15 cmH2O to the isolated upper airway in early inspiration while the animal was breathing room air, 100% O2, 6% CO2 in O2, or 9% CO2 in O2. The negative pressure pulses produced a reversible inhibition of inspiration in most trials with resultant increase in inspiratory duration (TI); no change was observed in peak diaphragmatic electromyogram (Dia EMG) or expiratory duration, whereas a decrease was seen in mean inspiratory drive (peak Dia EMG/TI). This prolongation of inspiratory duration and decrease in mean inspiratory drive with negative pressure pulses persisted at higher levels of CO2; the slopes of the test breaths were not significantly different from that of control breaths. These results suggest that upper airway negative pressure pulses are equally effective in altering the breathing pattern at all levels of CO2.  相似文献   

3.
Influence of lung volume on oxygen cost of resistive breathing   总被引:2,自引:0,他引:2  
We examined the relationship between the O2 cost of breathing (VO2 resp) and lung volume at constant load, ventilation, work rate, and pressure-time product in five trained normal subjects breathing through an inspiratory resistance at functional residual capacity (FRC) and when lung volume (VL) was increased to 37 +/- 2% (mean +/- SE) of inspiratory capacity (high VL). High VL was maintained using continuous positive airway pressure of 9 +/- 2 cmH2O and with the subjects coached to relax during expiration to minimize respiratory muscle activity. Six paired runs were performed in each subject at constant tidal volume (0.62 +/- 0.2 liters), frequency (23 +/- 1 breaths/min), inspiratory flow rate (0.45 +/- 0.1 l/s), and inspiratory muscle pressure (45 +/- 2% of maximum static pressure at FRC). VO2 resp increased from 109 +/- 15 ml/min at FRC by 41 +/- 11% at high VL (P less than 0.05). Thus the efficiency of breathing at high VL (3.9 +/- 0.2%) was less than that at FRC (5.2 +/- 0.3%, P less than 0.01). The decrease in inspiratory muscle efficiency at high VL may be due to changes in mechanical coupling, in the pattern of recruitment of the respiratory muscles, or in the intrinsic properties of the inspiratory muscles at shorter length. When the work of breathing at high VL was normalized for the decrease in maximum inspiratory muscle pressure with VL, efficiency at high VL (5.2 +/- 0.3%) did not differ from that at FRC (P less than 0.7), suggesting that the fall in efficiency may have been related to the fall in inspiratory muscle strength. During acute hyperinflation the decreased efficiency contributes to the increased O2 cost of breathing and may contribute to the diminished inspiratory muscle endurance.  相似文献   

4.
We determined effects of augmented inspiratory and expiratory intrathoracic pressure or abdominal pressure (Pab) excursions on within-breath changes in steady-state femoral venous blood flow (Qfv) and net Qfv during tightly controlled (total breath time = 4 s, duty cycle = 0.5) accessory muscle/"rib cage" (DeltaPab <2 cmH2O) or diaphragmatic (DeltaPab >5 cmH2O) breathing. Selectively augmenting inspiratory intrathoracic pressure excursion during rib cage breathing augmented inspiratory facilitation of Qfv from the resting limb (69% and 89% of all flow occurred during nonloaded and loaded inspiration, respectively); however, net Qfv in the steady state was not altered because of slight reductions in femoral venous return during the ensuing expiratory phase of the breath. Selectively augmenting inspiratory esophageal pressure excursion during a predominantly diaphragmatic breath at rest did not alter within-breath changes in Qfv relative to nonloaded conditions (net retrograde flow = -9 +/- 12% and -4 +/- 9% during nonloaded and loaded inspiration, respectively), supporting the notion that the inferior vena cava is completely collapsed by relatively small increases in gastric pressure. Addition of inspiratory + expiratory loading to diaphragmatic breathing at rest resulted in reversal of within-breath changes in Qfv, such that >90% of all anterograde Qfv occurred during inspiration. Inspiratory + expiratory loading also reduced steady-state Qfv during mild- and moderate-intensity calf contractions compared with inspiratory loading alone. We conclude that 1) exaggerated inspiratory pressure excursions may augment within-breath changes in femoral venous return but do not increase net Qfv in the steady state and 2) active expiration during diaphragmatic breathing reduces the steady-state hyperemic response to dynamic exercise by mechanically impeding venous return from the locomotor limb, which may contribute to exercise limitation in health and disease.  相似文献   

5.
In this study, noninvasive measurements of cardiac output and O2 consumption were performed to estimate the blood flow to and efficiency of the respiratory muscles that are used in elevated inspiratory work loads. Five subjects were studied for 4.5 min at a respiratory rate of 18 breaths/min and a duty cycle of 0.5. Studies were performed at rest without added respiratory loads and at elevated inspiratory work loads with the use of an inspiratory valve that permitted flow only when a threshold pressure was maintained. Cardiac output and O2 consumption were calculated using a rebreathing technique. Respiratory muscle blood flow and O2 consumption were estimated as the difference between resting and loaded breathing. Work of breathing was calculated by integrating the product of mouth pressure and volume. Increases in cardiac output and O2 consumption in response of 4.5 min loaded breathing averaged 1.84 l/min and 108 ml/min, respectively. No increases were seen in response to 20-s loaded breathing. In a separate series of experiments on four subjects, though, cardiac output increased for the first 2 min then leveled off. These results indicate that the increase in cardiac output was a metabolic effect of the increased work load and was not caused primarily by the influence of the highly negative intrathoracic pressure on venous return. Efficiency of the respiratory muscles during inspiratory threshold loading averaged 5.9%, which was similar to measurements of efficiency of respiratory muscles using whole-body O2 consumption that have been reported previously in humans and in dogs.  相似文献   

6.
Airway obstruction during periodic breathing in premature infants   总被引:1,自引:0,他引:1  
To characterize changes in pulmonary resistance, timing, and respiratory drive during periodic breathing, we studied 10 healthy preterm infants (body wt 1,340 +/- 240 g, postconceptional age 35 +/- 2 wk). Periodic breathing in these infants was defined by characteristic cycles of ventilation with intervening respiratory pauses greater than or equal to 2 s. Nasal airflow was recorded with a pneumotachometer, and esophageal or pharyngeal pressure was recorded with a fluid-filled catheter. Pulmonary resistance at half-maximal tidal volume, inspiratory time (TI), expiratory time (TE), and mean inspiratory flow (VT/TI) were derived from computer analysis of five cycles of periodic breathing per infant. In 80% of infants periodic breathing was accompanied by completely obstructed breaths at the onset of ventilatory cycles; the site of airway obstruction occurred within the pharynx. The first one-third of the ventilatory phase of each cycle was accompanied by the highest airway resistance of the entire cycle (168 +/- 98 cmH2O.l-1.s). In all infants TI was greatest at the onset of the ventilatory cycle, VT/TI was maximal at the midpoint of the cycle, and TE was longest in the latter two-thirds of each cycle. A characteristic increase and subsequent decrease of 4.5 +/- 1.9 ml in end-expiratory volume also occurred within each cycle. These results demonstrate that partial or complete airway obstruction occurs during periodic breathing. Both apnea and periodic breathing share the element of upper airway instability common to premature infants.  相似文献   

7.
We tested the hypothesis, motivated in part by a coordinated computational cough network model, that alterations of mean systemic arterial blood pressure (BP) influence the excitability and motor pattern of cough. Model simulations predicted suppression of coughing by stimulation of arterial baroreceptors. In vivo experiments were conducted on anesthetized spontaneously breathing cats. Cough was elicited by mechanical stimulation of the intrathoracic airways. Electromyograms (EMG) of inspiratory parasternal, expiratory abdominal, laryngeal posterior cricoarytenoid (PCA), and thyroarytenoid muscles along with esophageal pressure (EP) and BP were recorded. Transiently elevated BP significantly reduced cough number, cough-related inspiratory, and expiratory amplitudes of EP, peak parasternal and abdominal EMG, and maximum of PCA EMG during the expulsive phase of cough, and prolonged the cough inspiratory and expiratory phases as well as cough cycle duration compared with control coughs. Latencies from the beginning of stimulation to the onset of cough-related diaphragm and abdominal activities were increased. Increases in BP also elicited bradycardia and isocapnic bradypnea. Reductions in BP increased cough number; elevated inspiratory EP amplitude and parasternal, abdominal, and inspiratory PCA EMG amplitudes; decreased total cough cycle duration; shortened the durations of the cough expiratory phase and cough-related abdominal discharge; and shortened cough latency compared with control coughs. Reduced BP also produced tachycardia, tachypnea, and hypocapnic hyperventilation. These effects of BP on coughing likely originate from interactions between barosensitive and respiratory brainstem neuronal networks, particularly by modulation of respiratory neurons within multiple respiration/cough-related brainstem areas by baroreceptor input.  相似文献   

8.
In six normal male subjects we compared the O2 cost of resistive breathing (VO2 resp) between equivalent external inspiratory (IRL) and expiratory loads (ERL) studied separately. Each subject performed four pairs of runs matched for tidal volume, breathing frequency, flow rates, lung volume, pressure-time product, and work rate. Basal O2 uptake, measured before and after pairs of loaded runs, was subtracted from that measured during resistive breathing to obtain VO2 resp. For an equivalent load, the VO2 resp during ERL (184 +/- 17 ml O2/min) was nearly twice that obtained during IRL (97 +/- 9 ml O2/min). This twofold difference in efficiency between inspiratory and expiratory resistive breathing may reflect the relatively lower mechanical advantage of the expiratory muscles in overcoming respiratory loads. Variable recruitment of expiratory muscles may explain the large variation of results obtained in studies of respiratory muscle efficiency in normal subjects.  相似文献   

9.
Spontaneous inhalation of acrolein vapor (350 ppm, 1 ml/100 g body wt) elicited an immediate and transient inhibitory effect on breathing in anesthetized rats, characterized by a prolongation of expiratory duration and accompanied by a bradycardia; ventilation was reduced by 47 +/- 6%, which returned to baseline after three to seven breaths. When both vagi were cooled to 6.6 +/- 0.1 degrees C, the reflex apneic response to lung inflation was completely abolished but the bradypneic response to acrolein was not affected. After perineural capsaicin treatment of both cervical vagi to selectively block the capsaicin-sensitive C-fiber afferents, acrolein no longer evoked an inhibitory effect on breathing; conversely, an augmented inspiration was consistently elicited with the first breath of acrolein inhalation, which was subsequently abolished by cooling both vagi to 6.5 degrees C. The inhibitory effect of inhaling acrolein at a lower concentration (200 ppm) was not detectable, whereas that of a higher concentration (600 ppm) was more intense and prolonged. All these responses were completely eliminated by bilateral vagotomy. These results suggest that inhaled acrolein activated both vagal C-fiber endings and rapidly adapting irritant receptors in the airways, but the acrolein-induced inhibitory effect on breathing was elicited primarily by the C-fiber afferent stimulation.  相似文献   

10.
Oronasal partitioning of ventilation during exercise in humans   总被引:1,自引:0,他引:1  
The partitioning of oronasal breathing was studied in five normal subjects during progressive exercise. Subjects performed three to five identical runs, each consisting of four 1-min work periods at increments of 50 W. Nasal and oral airflow were measured simultaneously using a partitioned face mask both during and for 4 min after exercise. Total mean flows were the sum of nasal and oral flows. At a total mean inspiratory flow of 2 l/s, the nasal fraction of total flow was 0.36 +/- 0.04 (SE) and decreased by 6 +/- 3% between total flows of 1.5 and 2.5 l/s. Throughout exercise, the nasal fraction of total mean inspiratory flow did not differ from that of total expiratory flow and was similar to that of total mean inspiratory flow during the postexercise period at a corresponding total mean flow (both P greater than 0.02). The results show that oronasal flow partitioning is not directly due to the exercise itself but is related to the level of ventilation and is uninfluenced by the direction of upper airway flow (i.e., inspiratory vs. expiratory). These findings suggest tightly controlled modulation of the relative resistances of the oral and/or nasal pathways.  相似文献   

11.
We compared respiratory patterning at rest and during steady cycle exercise at work rates of 30, 60, and 90 W in 7 male chronically laryngectomized subjects and 13 normal controls. Breathing was measured with a pneumotachograph and end-tidal PCO2 by mass spectrometer. Inspired air was humidified and enriched to 35% O2. Peak flow, volume, and times for the inspiratory and expiratory half cycles, time for expiratory flow, minute ventilation, and mean inspiratory flow were computer averaged over at least 40 breaths at rest and during the last 2 min of 5-min periods at each work rate. During the transition from rest to exercise and with increasing work rate in both groups, there was an increase in respiratory rate and depth with selective and progressive shortening of expiratory time; these responses were not significantly different between the two groups, but there was a suggestion that respiratory "drive" as quantitated by mean inspiratory flow may limit in the laryngectomized subjects at high work rates. Time for expiratory flow increased on transition from rest to exercise and then decreased in both groups as the work rate increased; it was shorter in the laryngectomy than control group at all levels. In the laryngectomized subjects there was significantly more breath-by-breath scatter in some variables at rest, but there was no difference during exercise. It is concluded that chronic removal of the larynx and upper airways in mildly hyperoxic conscious humans has only subtle and, therefore, functionally insignificant effects on breathing during moderate exercise. Evidence is provided that the upper airways can modulate expiratory flow but not expiratory time during exercise.  相似文献   

12.
Negative pressure applied to the upper airway has an excitatory effect on the activity of upper airway muscles and an inhibitory effect on thoracic inspiratory muscles. The role of lung volume feedback in this response was investigated in 10 anesthetized spontaneously breathing adult rabbits. To alter lung volume feedback, the lower airway was exposed to SO2 (250 ppm for 15 min), thereby blocking slowly adapting receptors (SARs). Negative pressure pulses (5, 10, and 20 cmH2O, 300-ms duration) were applied to the functionally isolated upper airway before and after SAR blockade. Tracheal airflow and electromyogram (EMG) of the genioglossus and alae nasi were recorded. Peak EMG, peak inspiratory flow, tidal volume, and respiratory timing of control breaths (3 breaths immediately preceding test) and test breaths were determined. Analysis of variance was used to determine the significance of the effects. Negative pressure pulses increased peak EMG of genioglossus and alae nasi and inspiratory duration and decreased peak inspiratory flow. These effects were larger after SAR blockade. We conclude that a decrease in volume feedback from the lung augments the response to upper airway pressure change.  相似文献   

13.
Experimental data suggest the presence of sensory receptors specific to the nasopharynx that may reflexly influence respiratory activity. To investigate the effects of inspired air temperature on upper airway dilator muscle activity during nose breathing, we compared phasic genioglossus electromyograms (EMGgg) in eight normal awake adults breathing cold dry or warm humidified air through the nose. EMGgg was measured with peroral bipolar electrodes during successive trials of cold air (less than or equal to 15 degrees C) and warm air (greater than or equal to 34 degrees C) nasal breathing and quantified for each condition as percent activity at baseline (room temperature). In four of the subjects, the protocol was repeated after topical nasal anesthesia. For all eight subjects, mean EMGgg was greater during cold air breathing than during baseline (P less than 0.005) or warm air breathing (P less than 0.01); mean EMGgg during warm air breathing was not significantly changed from baseline. Nasal anesthesia significantly decreased the mean EMGgg response to cold air breathing. Nasal airway inspiratory resistance, measured by posterior rhinomanometry in six subjects under similar conditions, was no different for cold or warm air nose breathing [cold 1.4 +/- 0.7 vs. warm 1.4 +/- 1.1 (SD) cmH2O.l-1.s at 0.4 l/s flow]. These data suggest the presence of superficially located nasal cold receptors that may reflexly influence upper airway dilating muscle activity independently of pressure changes in awake normal humans.  相似文献   

14.
We investigated the effect of acute and sustained inspiratory resistive loading (IRL) on the activity of expiratory abdominal muscles (EMGab) and the diaphragm (EMGdi) and on ventilation during wakefulness and non-rapid-eye-movement (NREM) sleep in healthy subjects. EMGdi and EMGab were measured with esophageal and transcutaneous electrodes, respectively. During wakefulness, EMGdi increased in response to acute loading (18 cmH2O.l-1.s) (+23%); this was accompanied by preservation of tidal volume (VT) and minute ventilation (VE). During NREM sleep, no augmentation was noted in EMGdi or EMGab. Inspiratory time (TI) was prolonged (+5%), but this was not sufficient to prevent a decrease in both VT and VE (-21 and -20%, respectively). During sustained loading (12 cmH2O.l-1 s) in NREM sleep, control breaths (C) were compared with the steady-state loaded breaths (SS) defined by breaths 41-50. Steady-state IRL was associated with augmentation of EMGdi (12%) and EMGab (50%). VT returned to control levels, expiratory time shortened, and breathing frequency increased. The net result was the increase in VE above control levels (+5%, P less than 0.01). No change was noted in end-tidal CO2 or O2. We concluded that 1) wakefulness is a prerequisite for immediate load compensation (in its absence, TI prolongation is the only compensatory response) and 2) during sustained IRL, the augmentation of EMGdi and EMGab can lead to complete ventilatory recovery without measurable changes in chemical stimuli.  相似文献   

15.
The O2 consumption of the respiratory muscles (VO2resp), work of breathing, and the time integral of the transdiaphragmatic pressure (TTdi) were measured in four normal subjects breathing against inspiratory resistance. A total of 39 runs were performed at mean tidal transdiaphragmatic pressures (Pdi) ranging from 15 to 53 cmH2O, respiratory frequencies from 3.5 to 22 breaths/min, and inspiratory time durations (TI) from 32 to 76% of the total breath duration. Each run was maintained from 8 to 17 min and the above parameters were kept constant by the subject via visual feedback of Pdi and TI with an oscilloscope. Most of the runs (36 of 39) were performed at TTdi values below those known to produce respiratory muscle fatigue. We found a strong linear correlation between the VO2resp and the TTdi (r = 0.74, P less than 0.001) and a weaker correlation between VO2resp and W (r = 0.31, P less than 0.05). These data suggest that TTdi is a good estimator of VO2resp over a wide range of respiratory patterns during inspiratory resistance breathing. The high variability seen in respiratory muscle efficiency during resistive breathing may be due to W not being a good indicator of the energy consumed by the respiratory muscles.  相似文献   

16.
We studied the effect of hypoxia-induced unstable and periodic breathing on the incidence of obstructed breaths in nine subjects who varied widely in their increase in total pulmonary resistance (RL) during non-rapid-eye-movement (NREM) sleep. During normoxic NREM sleep, all subjects showed hypoventilation, augmented diaphragmatic electromyogram (EMGdi), and increased RL. This response varied: two subjects doubled their mean RL (range 6-9 cmH2O X l-1 X s); four moderate snorers increased RL four- to eightfold (RL = 16-48 cmH2O X l-1 X s); three heavy snorers showed high RL (31-89 cmH2O X l-1 X s) plus cyclical obstructive hypopnea as their predominant breathing pattern. In seven of nine subjects, hypoxia and coincident hypocapnia initially caused an irregular cyclical breathing pattern with obstructed breaths (RL greater than 50 cmH2O X l-1 X s). The incidence of obstructed breaths induced by unstable breathing was closely correlated with the level of RL experienced in the control condition of normoxic sleep (r = 0.91). The obstructed breaths had relatively high O2 saturation (90-96%) and markedly reduced EMGdi activity and peak flow rate (less than 0.2 l/s) compared with breaths immediately after the obstructed breaths, which showed lower O2 saturation (81-93%) and markedly augmented EMGdi and flow rates. After 3-6 cycles of obstructive hypopnea, periodic breathing occurred in most subjects. During periodic breathing in six of seven subjects, the incidence of obstructed or high-resistance breaths was decreased or eliminated since each central apneic period was followed by breath clusters characterized by very high EMGdi, very low RL, and high flow rates. The remaining subject showed a high incidence of obstructed breaths during all phases of normoxic and hypoxic sleep. These data show that hypoxia-induced instability in breathing pattern can cause obstructed breaths during sleep coincident with reduced motor output to inspiratory muscles. However, this obstruction is only manifested in subjects susceptible to upper airway atonicity and narrowing (such as snorers) and can be prevented in most cases if respiratory drive is permitted to reach sufficiently high levels (as during central apnea).  相似文献   

17.
Effects of expiratory resistive loading on the sensation of dyspnea   总被引:1,自引:0,他引:1  
To determine whether an increase in expiratory motor output accentuates the sensation of dyspnea (difficulty in breathing), the following experiments were undertaken. Ten normal subjects, in a series of 2-min trials, breathed freely (level I) or maintained a target tidal volume equal to (level II) or twice the control (level III) at a breathing frequency of 15/min (similar to the control frequency) with an inspiratory load, an expiratory load, and without loads under hyperoxic normocapnia. In tests at levels II and III, end-expiratory lung volume was maintained at functional residual capacity. A linear resistance of 25 cmH2O.1(-1).s was used for both inspiratory and expiratory loading; peak mouth pressure (Pm) was measured, and the intensity of dyspnea (psi) was assessed with a visual analog scale. The sensation of dyspnea increased significantly with the magnitude of expiratory Pm during expiratory loading (level II: Pm = 9.4 +/- 1.5 (SE) cmH2O, psi = 1.26 +/- 0.35; level III: Pm = 20.3 +/- 2.8 cmH2O, psi = 2.22 +/- 0.48) and with inspiratory Pm during inspiratory loading (level II: Pm = 9.7 +/- 1.2 cmH2O, psi = 1.35 +/- 0.38; level III: Pm = 23.9 +/- 3.0 cmH2O, psi = 2.69 +/- 0.60). However, at each level of breathing, neither the intensity of dyspnea nor the magnitude of peak Pm during loading was different between inspiratory and expiratory loading. The augmentation of dyspnea during expiratory loading was not explained simply by increases in inspiratory activity. The results indicate that heightened expiratory as well as inspiratory motor output causes comparable increases in the sensation of difficulty in breathing.  相似文献   

18.
Dynamics of breathing in the hypoxic awake lamb   总被引:1,自引:0,他引:1  
Newborn mammals respond to hypoxia with an immediate hyperventilation that is rapidly dampened. Changes in mechanical properties of the respiratory system during hypoxia have been considered an important reason for this fall in minute ventilation (VE). We have studied the dynamic mechanical behavior of the respiratory system in eight unanesthetized intact newborn lambs (mean age 2 days) during normoxia and hypoxia (FIO2 = 0.08). Mouth pressure (P), airflow (V), and volume (V) were recorded while lambs were breathing through a leak-proof face mask and a pneumotachograph. Active compliance (C') and resistance (R') of the respiratory system were computed from P developed during an inspiratory effort against airway closure at end expiration and V and V of the preceding breaths. Tidal expiratory V-V curves were analyzed to estimate the elevation in functional residual capacity (FRC) over resting volume (Vr). After hypoxia, there was an immediate increase in VE in the first 2 min, from 0.49 to 1.13 l.kg-1.min-1, followed by a rapid decrease to 0.80. After 8 min of hypoxia, C' was unchanged. The inspiratory R' decreased during hypoxia, probably reflecting a drop in inspiratory laryngeal resistance. The expiratory V-V curves during hypoxia showed considerable braking, often with a double peak in expiratory V. This pattern was only occasionally seen during normoxia. In animals with a linear segment of the expiratory V-V curves the FRC-Vr difference could be calculated and averaged 1.93 ml/kg during normoxia and 3.47 during hypoxia. The recoil P of the respiratory system at end expiration was 0.75 cmH2O during normoxia vs. 1.63 cmH2O during hypoxia (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Mechanism of action of ozone on the human lung   总被引:3,自引:0,他引:3  
Fourteen healthy normal volunteers were randomly exposed to air and 0.5 ppm of ozone (O3) in a controlled exposure chamber for a 2-h period during which 15 min of treadmill exercise sufficient to produce a ventilation of approximately 40 l/min was alternated with 15-min rest periods. Before testing an esophageal balloon was inserted, and lung volumes, flow rates, maximal inspiratory (at residual volume and functional residual capacity) and expiratory (at total lung capacity and functional residual capacity) mouth pressures, and pulmonary mechanics (static and dynamic compliance and airway resistance) were measured before and immediately after the exposure period. After the postexposure measurements had been completed, the subjects inhaled an aerosol of 20% lidocaine until response to citric acid aerosol inhalation was abolished. All of the measurements were immediately repeated. We found that the O3 exposure 1) induced a significant mean decrement of 17.8% in vital capacity (this change was the result of a marked fall in inspiratory capacity without significant increase in residual volume), 2) significantly increased mean airway resistance and specific airway resistance but did not change dynamic or static pulmonary compliance or viscous or elastic work, 3) significantly reduced maximal transpulmonary pressure (by 19%) but produced no changes in inspiratory or expiratory maximal mouth pressures, and 4) significantly increased respiratory rate (in 5 subjects by more than 6 breaths/min) and decreased tidal volume.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Expiratory muscle fatigue in normal subjects   总被引:4,自引:0,他引:4  
We examined expiratory muscle fatigue during expiratory resistive loading in 11 normal subjects. Subjects breathed against expiratory resistances at their own breathing frequency and tidal volume until exhaustion or for 60 min. Respiratory muscle strength was assessed from both the maximum static expiratory and inspiratory mouth pressures (PEmax and PImax). At the lowest resistance, PEmax and PImax measured after completion of the expiratory loaded breathing were not different from control values. With higher resistance, both PEmax and PImax were decreased (P less than 0.05), and the decrease lasted for greater than or equal to 60 min. The electromyogram high-to-low frequency power ratio for the rectus abdominis muscle decreased progressively during loading (P less than 0.01), but the integrated EMG activity did not change during recovery. Transdiaphragmatic pressure during loading was increased 3.6-fold compared with control (P less than 0.05). These findings suggest that expiratory resistive loaded breathing induces muscle fatigue in both expiratory and inspiratory muscles. Fatigue of the expiratory muscles can be attributed directly to the high work load and that of the inspiratory muscles may be related to increased work due to shortened inspiratory time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号