首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay has been developed to allow determination of total (i.e. bound and unbound) and free (i.e. unbound) topotecan (TPT) in mouse plasma in the presence and absence of anti-TPT antibodies. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Nova-Pak C18 column (3.9 mm x 150 mm, 4 microm) protected by a Nova-Pak C18 guard column (3.9 mm x 20 mm, 4 microm), where 10 mM KH(2)PO(4)-methanol-triethylamine (72:26:2 (v/v/v), pH 3.5) was used as the mobile phase. Topotecan was quantified with fluorescence detection using an excitation wavelength of 361 nm and an emission wavelength of 527 nm. The retention time for the internal standard, acridine, and TPT were 7.4 and 9.0 min, respectively. The lower limit of quantitation (LOQ) for TPT was determined as 0.02 ng in mouse plasma and mouse plasma ultrafiltrate, corresponding to a concentration of 1 ng/ml in 20 microl mouse plasma. The assay was shown to be linear over a concentration range of 1-500 ng/ml. The recoveries of free and total TPT from spiked mouse plasma were within 10% of theoretical values (assessed at 1, 20 and 500 ng/ml). The validated HPLC assay was applied to evaluate TPT pharmacokinetics following administration of TPT to Swiss Webster mice and to hyperimmunized and control BALB/c mice. The assay has been shown to be capable for measuring total and free TPT in mouse plasma with high sensitivity and will allow the testing of the effect of anti-TPT antibodies on the disposition of TPT.  相似文献   

2.
A HPLC assay method was modified and validated for the determination of 5-fluorouracil in human red blood cells, plasma and whole blood with a two-fold increased sensitivity (detection limit=10 ng/ml). The assay was linear from 25 to 1500 ng/ml and the accuracy ranged from 96.7 to 103.2% at 25 ng/ml, 94.8 to 99.4% at 500 ng/ml, and 98.9 to 99.5% at 1500 ng/ml. Intra-assay and inter-assay coefficients of variation were less than 8% over the range of concentrations and less than 8% over 10 days of analysis. After intravenous bolus and infusion of 5-fluorouracil in patients with colorectal cancer, the concentrations of 5-fluorouracil in whole blood were 108–111% of plasma concentrations, while packed red blood cells levels were 8–15% of plasma concentrations in the five patients studied. By utilising basic analytical hardware, this represents an accurate, precise, reproducible and affordable method for 5-fluorouracil pharmacokinetics investigation and therapeutic drug monitoring.  相似文献   

3.
The subcommissural organ (SCO) is an ependymal brain gland that releases glycoproteins into the ventricular cerebrospinal fluid where they condense to form the Reissner’s fiber (RF). We have developed a highly sensitive and specific two-antibody sandwich enzyme-linked immunosorbent assay (ELISA) for the quantification of the bovine SCO secretory material. The assay was based on the use of the IgG fraction of a polyclonal antiserum against the bovine RF as capture antibody and a pool of three peroxidase-labeled monoclonal antibodies that recognize non-overlapping epitopes of the RF glycoproteins as detection antibody. The detection limit was 1 ng/ml and the working range extended from 1 to 4000 ng/ml. The calibration curve, generated with RF glycoproteins, showed two linear segments: one of low sensitivity, ranging from 1 to 125 ng/ml, and the other of high sensitivity between 125 and 4000 ng/ml. This assay was highly reproducible (mean intra- and interassay coefficient of variation 2.2% and 5.3%, respectively) and its detectability and sensitivity were higher than those of ELISAs using exclusively either polyclonal or monoclonal antibodies against RF glycoproteins. The assay succeeded in detecting and measuring secretory material in crude extracts of bovine SCO, culture medium supernatant of SCO explants and incubation medium of bovine RF; however, soluble secretory material was not detected in bovine cerebrospinal fluid.  相似文献   

4.
A method for the determination of sertraline in human plasma using gas chromatography-mass spectrometry (GC-MS), with the selected ion-monitoring (SIM) mode, was described. The following was used in this study: (1) single liquid-liquid extraction at alkaline pH after deproteinization of plasma protein and (2) perfluoroacylation with HFBA, which has higher sensitivity (about 10-fold) compared with previous reported derivatization. The detection limit for the SIM of sertraline as an N-HFB derivative was 0.1 ng/ml, and its recovery was 80-85%. The linear response was obtained in the range of 0.2-10.0 ng/ml with a correlation coefficient of 0.999. The coefficient of variation (C.V.%) was less than 12.1% in the 1-30 ng/ml, and less than 18.2% at 0.2 ng/ml, and the accuracy was less than 10% at all of the concentration range. These findings indicate that this assay method has adequate precision and accuracy to determine the amount of sertraline in human plasma. After pharmacokinetics was performed with this assay method following oral administration of sertraline hydrochloride in man, moment analysis revealed that pharmacokinetic parameters for sertraline (Cmax, 10.3 ng/ml; Tmax, 8.0 h; T(1/2) 28.6 h) were similar to previously reported results. These results indicate that this simple and sensitive assay method is readily applicable to the pharmacokinetic studies of sertraline.  相似文献   

5.
A sensitive high-performance liquid chromatographic assay has been developed and validated for the determination of methyl N-[5-[[4-(2-pyridinyl)-1-piperazinyl]carbonyl]-1H-benzimidazol-2-yl] carbamate (CDRI compound 81/470) in normal rat blood. The method described herein is simple, with improved selectivity and sensitivity over a previously reported HPLC method. The limit of quantitation is 10 ng/ml (method 1) and 2.5 ng/ml (method 2) in blood, as compared with 40 ng/ml for the previous method. The standard curve in blood is linear over the concentration range 10–1000 ng/ml in method 1 and 2.5–1000 ng/ml in method 2 and the extraction recovery is higher than 80% for both methods.  相似文献   

6.
An enzyme-linked immunosorbent assay system combined with microcomputer data analysis was established as a quantitative assay method of immunoglobulins. The assay system was applied to measure IgG and IgM levels of anti-microbe antibodies in animals, especially mouse and rat. And now the measurement of IgG and IgM levels (ng/ml) of anti-Sendai virus (HVJ) antibodies in naturally infected mice is available. The assay system could improve serodiagnosis in the specificity and sensitivity and in the rapid treatment of many serum samples. The operation of this system was performed by a microcomputer, FM 8 connected Titertek Multiskan MC. The limited sensitivity of this assay for IgG and IgM was 10 ng/ml and 30 ng/ml, respectively. Ninety-one of serum samples were positive for IgG and/or IgM (45 samples for IgG and IgM, 44 samples for IgG, 2 samples for IgM) to Sendai virus in the tested 279 mouse sera, and serum titers were ranged from 1: 10 to 1: 12,800 in the IgG, and from 1: 20 to 1: 160 in the IgM. In these titers, serum IgG and IgM amounts were estimated to be 0.1 to 154 micrograms/ml and 0.5 to 4.8 micrograms/ml, respectively. Relationships of serum titers and antibody amounts were almost consisted, being judged like that approximately 10 micrograms/ml is 1: 400, 30 micrograms/ml is 1: 1,600 in IgG, and 2.4 micrograms/ml is 1: 80, 4 micrograms/ml is 1: 160 in IgM.  相似文献   

7.
An assay comprising two simple, selective and isocratic HPLC methods with UV detection was developed and validated for measuring warfarin enantiomers and all five warfarin monohydroxylated metabolites in patient blood plasma. Following liquid/liquid extraction from 1 ml of blood plasma a baseline separation of analytes was achieved on chiral (alpha(1) acid glycoprotein - AGP) and achiral (C(18)) column. Both methods were consistent (R.S.D.<6.9% for warfarin enantiomers and<8.9% for monohydroxylated metabolites) and linear (r>0.998). The limits of detection were 25 ng/ml for warfarin enantiomers, 25 ng/ml for 4'-, 10-, 6- and 7-hydroxywarfarin, 35 ng/ml for 8-hydroxywarfarin and 50 ng/ml for racemic warfarin. In a clinical study in 204 patients, it was confirmed that the assay is appropriate for evaluation of influences of genetic polymorphisms, demographic factors and concomitant drug treatment on warfarin metabolism.  相似文献   

8.
A solid-phase extraction (SPE) procedure was developed for the quantification of nalbuphine in a small volume (500 μl) of human plasma with subsequent assay by high-performance liquid chromatography (HPLC) and electrochemical detection using 6-monoacetylmorphine as internal standard. Plasma was extracted using Bond Elute certified extraction columns (LCR: 10 ml, 130 mg) after conditioning with methanol and 0.2 M Tris buffer (pH 8). Elution was performed with a CH2Cl2-isopropanol-NH4OH (79:20:, v/v). The organic phase was evaporated to dryness and resuspended in HPLC mobile phase containing 2% isopropanol. Linearity was assessed over the 5–100 ng/ml concentration range and a straight line passing through the origin was obtained. Experiments with spiked plasma samples resulted in recoveries of 95±5.4% and 98±6.2% for nalbuphine and 6-monoacetylmorphine, respectively. The optimal pH conditions for the SPE were found at pH 8. The intra-day coefficients of variation (C.V.) for 5, 40, and 100 ng/ml were 5.3, 3.0 and 2.3% (n=8) and the inter-day C.V.s were 7.7, 3.2 and 3.5% (n=10), respectively. The detection limit for 500 μl plasma sample was 0.02 ng/ml and the limit of quantification 0.1 ng/ml (C.V.=12.4%). The ease of the proposed method of analysis, as well as its high accuracy and sensitivity allow its application to pharmacokinetic studies. A preliminary kinetic profile of nalbuphine after rectal administration in a pediatric patient is presented.  相似文献   

9.
目的:利用稀土离子作为示踪剂,建立DON/ZEN双标记间接竞争时间分辨荧光免疫分析方法同时检测DON、ZEN。 方法:以DON BSA、ZEN-BSA共包被于固相微孔板,与DON/ZEN标准或样品中的DON、ZEN竞争结合抗DON多抗、抗ZEN单抗,然后分别用稀土离子Eu3+-羊抗兔IgG及Sm3+ 羊抗鼠IgG进行示踪检测,并对建立DON/ZEN-双标记TRFIA进行方法学的考核。结果:DON/ZEN-双标记TRFIA检测灵敏度,DON为0.2 ng/ml、ZEN为0.7 ng/ml,检测范围为:DON 0.2~100 ng/ml,ZEN 0.7~50 ng/ml,批内、批间变异率均小于10%。不同样品添加回收实验表明玉米、小麦样品中DON平均回收率分别为102.8%、98.8%,ZEN平均回收率分别为94.2%、95.7%。DON/ZEN-双标TRFIA检测时,DON与ZEN不相互干扰,该方法特异性好。玉米样品检测结果表明,DON/ZEN双标记TRFIA与单标记DON -TRFIA、ZEN-TRFIA试剂盒结果高度相关,具有较好的一致性,两者检测DON的结果相关系数为0.9760,检测ZEN结果的相关系数为0.9695,结论:DON/ZEN-双标记TRFIA灵敏度高,检测范围宽,重复性、稳定性好,一次检测可同时得到DON、ZEN两个结果,是一种简便、快速、经济、稳定、可进行大批量样品筛查的检测方法。  相似文献   

10.
The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reverse-phase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of +/- 15%. The HPLC/UV method can be routinely applied for concentrations down to 10-20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.  相似文献   

11.
A method is described for the determination of the two enantiomers of mirtazapine in human blood plasma by high-performance liquid chromatography. Measurements were performed on drug free plasma spiked with mirtazapine and used to prepare and validate standard curves. Levels of enantiomers of mirtazapine were also measured in patients being treated for depression with racemic mirtazapine. Mirtazapine was separated from plasma by solid-phase extraction using CERTIFY columns. Chromatographic separation was achieved using a Chiralpak AD column and pre-column and compounds were detected by their absorption at 290 nm. Imipramine was used as an internal standard. The assay was validated for each analyte in the concentration range 10–100 ng/ml. The coefficient of variance was 16% and 5.5% for(+)-mirtazapine for 10 and 100 ng/ml control specimens respectively and 15% and 7.3% for mirtazapine for 10 and 100 ng/ml control specimens respectively. This assay is appropriate for use in the clinical range. The range of plasma mirtazapine concentrations from eleven patients taking daily doses of 30–45 mg of racemate was <5 to 69 ng/ml for (+)-mirtazapine and 13–88 ng/ml for (−)-mirtazapine for blood specimens collected 10–17.5 h after taking the dose.  相似文献   

12.
A simple and highly sensitive high-performance liquid chromatography (HPLC) method for the simultaneous quantitative determination of lansoprazole enantiomers and their metabolites, 5-hydroxylansoprazole enantiomers and lansoprazole sulfone, in human plasma have been developed. Chromatographic separation was achieved with a Chiral CD-Ph column using a mobile phase of 0.5M NaClO(4)-acetonitrile-methanol (6:3:1 (v/v/v)). The analysis required only 100 microl of plasma and involved a solid-phase extraction with Oasis HLB cartridge, with a high extraction recovery (>94.1%) and good selectivity. The lower limit of quantification (LOQ) of this assay was 10 ng/ml for each enantiomer of both lansoprazole and 5-hydroxylansoprazole, and 5 ng/ml for lansoprazole sulfone. The coefficient of variation of inter- and intra-day assay was <8.0% and accuracy was within 8.4% for all analytes (concentration range 10-1000 ng/ml). The linearity of this assay was set between 10 and 1000 ng/ml (r2>0.999 of the regression line) for each of the five analytes. This method is applicable for accurate and simultaneous monitoring of the plasma levels of lansoprazole enantiomers and their metabolites in the renal transplant recipients.  相似文献   

13.
A method was developed for the assay of amitriptyline, amitriptyline-N-oxide, nortriptyline, desmethylnortriptyline and E (trans) and Z (cis) isomers of 10-hydroxyamitriptyline and of 10-hydroxynortriptyline in plasma and brain of animals, using high-performance liquid chromatography with ultraviolet detection (254 nm). Single extraction was performed at pH 10.5 from 0.25 ml of plasma or 1 ml of brain mixture. Chromatographic separations were achieved with a silica column and an aqueous methanol mobile phase containing ammonia. This procedure offers high sensitivity (8–10 ng/ml), high linearity (r > 0.99) and acceptable precision (coefficient of variation ≤ 13.3%). The method was used to determine levels of amitriptyline and its major metabolites in mice 30 min after a single intraperitoneal administration of amitriptyline (20 mg/kg).  相似文献   

14.
Two murine monoclonal antibodies to the macrocyclic trichothecene roridin A are described. Screening for antibody production was performed on absorbed anti-mouse immunoglobulin serum as double-antibody solid phase, and further characterization was done on affinity-purified anti-mouse IgG serum. The antibodies, designated 5G11 and 4H10, had affinity constants for roridin A of 9.25 X 10(7) and 1.7 X 10(7) liters/mol, respectively. In monoclonal antibody-based direct enzyme immunoassays, these IgG1 antibodies had detection limits for roridin A of 0.4 ng/ml (0.02 ng per assay) and 1.8 ng/ml (0.09 ng per assay), respectively. Both antibodies were most specific for the tested macrocyclic trichothecenes. The relative cross-reactivities of antibody 5G11 with roridin A, roridin J, verrucarin A, satratoxin G, and satratoxin H were 100.0, 43.8, 16.7, 3.7, and 18.9%, respectively; for antibody 4H10 they were 100.0, 6.3, 64.0, 4.4, and 4.9%, respectively.  相似文献   

15.
Two murine monoclonal antibodies to the macrocyclic trichothecene roridin A are described. Screening for antibody production was performed on absorbed anti-mouse immunoglobulin serum as double-antibody solid phase, and further characterization was done on affinity-purified anti-mouse IgG serum. The antibodies, designated 5G11 and 4H10, had affinity constants for roridin A of 9.25 X 10(7) and 1.7 X 10(7) liters/mol, respectively. In monoclonal antibody-based direct enzyme immunoassays, these IgG1 antibodies had detection limits for roridin A of 0.4 ng/ml (0.02 ng per assay) and 1.8 ng/ml (0.09 ng per assay), respectively. Both antibodies were most specific for the tested macrocyclic trichothecenes. The relative cross-reactivities of antibody 5G11 with roridin A, roridin J, verrucarin A, satratoxin G, and satratoxin H were 100.0, 43.8, 16.7, 3.7, and 18.9%, respectively; for antibody 4H10 they were 100.0, 6.3, 64.0, 4.4, and 4.9%, respectively.  相似文献   

16.
A sensitive stereoselective bioanalytical liquid chromatographic assay with mass spectrometric detection (LC-MS) was developed and validated for the on-line extraction and quantification of R- and S-methadone and the primary metabolite R- and S-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) from human plasma. Deproteinized plasma was injected directly onto a small C8 column, washed and then back-flushed using a column switching valve and a second pump onto an alpha1-acid glycoprotein analytical column, and enantioselective separation achieved using a mobile phase gradient of methanol and ammonium formate. Analytes were validated over a range of 0.1-25 ng/ml R- and S-EDDP and 0.1-100ng/ml R- and S-methadone, respectively. Unweighted standard curves were linear over this concentration range (regression coefficients > 0.999). Quality control samples were evaluated at 1, 5, 12.5 ng/ml R- and S-EDDP and 1, 10, 50 ng/ml R- and S-methadone. Intra- and inter-day accuracy was >95%, and intra- and inter-day coefficients of variation were less than 10% for all analytes and concentrations. This assay represents the only method currently available which combines on-line extraction and achieves chiral separation of both methadone and EDDP from plasma, and offers improvements in sensitivity over existing methods.  相似文献   

17.
Immunoreagents based on polymer dispersions consisting of unimodal polyacrolein (PAL) microspheres with diameters in the range 0.3-2.0 microns have been prepared and evaluated by various immunoassay techniques such as immunoradiometric assay of ferritin and microtitre particle agglutination and immunofiltration dot assay of group-specific polysaccharide of S. pyogenes (A-PS) in comparison with conventional carriers and methods. The antibodies were covalently or indirectly bound to the PAL. The coupled antibodies to ferritin retained a high average affinity (Ka = 4.5 x 10(9) M-1). In comparison with microcrystalline cellulose-based immunosorbent, more than an order-of-magnitude lower amount of PAL-IgG was necessary for the analysis of ferritin. Use of PAL-IgG gave a higher sensitivity of assay with a detection limit of 0.7 x 10(-13) M l-1 and a wider concentration range of antigen detection (about four orders of magnitude) without manifestation of the high-dose hook effect. Particle agglutination assay of A-PS in microtitre plate was shown to be a simple, demonstrative and highly sensitive one-step analytical method with a detection limit of 0.05 ng A-PS/ml or 10(4) cells/ml. The sensitivity of immunofiltration assay using both enzyme and latex markers was shown to be approximately the same (50 ng A-PS/ml) and the duration of the assay was 3-5 min. No cross-reaction of latex conjugates with non-A Streptococcus cell lysates were observed.  相似文献   

18.
Apolipoprotein A-I (apoA-I), the major protein component of human high density lipoprotein, appears intracellularly as an intermediate precursor (proapoA-I) with a hexapeptide extension (Arg-His-Phe-Trp-Gln-Gln) at its amino terminus. To investigate the regulation of processes that regulate plasma apoA-I levels, a sensitive and simple assay for proapoA-I is required. We describe a specific enzyme-linked immunosorbent assay (ELISA) for quantification of proapoA-I using monospecific rabbit antibodies raised against the peptide: Arg-His-Phe-Trp-Gln-Gln-Asp-Glu-Pro. The monospecificity of antibodies to propeptide has been checked and no cross-reaction with mature apoA-I has been found although three first mature apoA-I amino acids (Asp-Glu-Pro) were included in the immunizing peptide. The assay is a non-competitive sandwich ELISA in which polystyrene microtiter plates were used with antibodies to propeptide adsorbed on the wells. After incubation with plasma samples, the bound proapoA-I was revealed by labeled rabbit polyclonal antibodies directed against mature apoA-I. The working range was 10 to 100 ng/ml, recovery of proapoA-I added to plasma was 94.6 to 106.5%, and the intra- and interassay coefficients of variation were 3.8% and 7.9%, respectively. A delipidation step using diisopropylether-n-butanol was necessary to expose antigen sites of proapoA-I in native lipoproteins. Mean level of proapoA-I in normal subjects was 87 +/- 15 micrograms/ml. It represented 7.1% of total apoA-I while in Tangier serum it represented 29%.  相似文献   

19.
Reddy DS  Venkatarangan L  Chien B  Ramu K 《Steroids》2005,70(13):879-885
The testosterone metabolite 3alpha-androstanediol (5alpha-androstane-3alpha,17-diol) is a potential GABA(A) receptor-modulating neurosteroid with anticonvulsant properties and hence could act as a key neuromodulator in the central nervous system. However, there is no specific and sensitive assay for quantitative determination of the androgenic neurosteroid 3alpha-androstanediol in biological samples. We have established a liquid chromatography-tandem mass spectrometry (LC-MS-MS) assay to measure 3alpha-androstanediol in rat plasma. Standard 3alpha-androstanediol added to rat plasma has been successfully analysed with excellent linearity, specificity, sensitivity, and reproducibility. The sensitivity of the method was < 10 ng/ml with a detection limit of 2 ng/ml (6.8 nmol/l) and a linear range of 10-2000 ng/ml. The method was used for the analysis of testosterone-induced increase in plasma 3alpha-androstanediol levels in rats. Testosterone produced a dose-dependent elevation in plasma 3alpha-androstanediol, which was almost completely prevented by pretreatment with the 5alpha-reductase inhibitor finasteride, indicating that 3alpha-androstanediol is synthesized from testosterone via a 5alpha-reductase pathway. This LC-MS-MS method allows accurate, high-throughput analysis of 3alpha-androstanediol in small amounts (200 microl) of plasma and possibly other biological samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号