首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method is described for the quantification of two metabolites of cyclophosphamide, specifically 4-hydroxycyclophosphamide (HCy), and carboxyethylphosphoramide mustard (CEPM). Plasma HCy is derivatized to the phenylhydrazone which is quantitated by LC-MS monitoring the chloride adduct of the derivative. The LLOQ based on material applied to the system is approximately 20 fmol. Plasma CEPM concentration is determined using LC-MS with a deuterated internal standard. Both assays have 50-fold dynamic range and require less than 4h to complete. The development of this rapid analytical method makes it feasible to adjust the dose of cyclophosphamide based on the pharmacokinetic disposition of HCy and CEPM in hopes of decreasing nonrelapse mortality in cancer patients.  相似文献   

2.
A quantitative liquid chromatographic-electrospray ionization mass spectrometry method for the determination of naltrexone and 6beta-naltrexol in guinea pig plasma has been developed and validated using naloxone as an internal standard. A single step precipitation-extraction technique was carried out to extract the plasma samples using acetonitrile:ethyl acetate (1:1, v/v). The chromatographic separation was performed on a C(18) column using a mobile phase consisting of 35:65 (v/v) acetonitrile:2 mM ammonium acetate with 0.01 mM ammonium citrate at a flow rate of 0.25 mL/min. The analyte was detected after positive electrospray ionization using selected ion monitoring (SIM) mode. The mean recoveries for naltrexone, naltrexol, and naloxone were 91.7, 89.3, and 99.0%, respectively. The lower limit of quantification (LLOQ) for naltrexone and 6beta-naltrexol was 1.25 ng/mL, and the limit of detection (LOD) was 0.75 ng/mL. The method was applied to a pharmacokinetic study in order to assess the drug disposition of naltrexone in guinea pigs.  相似文献   

3.
We have developed a high-performance liquid chromatography-electrospray ionization mass spectrometry (LC-MS) method for quantifying docetaxel and paclitaxel in human plasma. The assay fulfills the need for defining the lower plasma concentrations of these antineoplastic agents that result from a number of changes in how these agents are used clinically. The assay uses paclitaxel as the internal standard for docetaxel, and vice versa; solid-phase extraction; a Phenomenex Hypersil ODS (5 micrometer, 100x2 mm) reversed-phase analytical column; an isocratic mobile phase of 0.1% formic acid in methanol-water (70:30, v/v); and mass spectrometric detection using electrospray positive mode electron ionization. The assay has a lower limit of quantitation (LLOQ) of 0.3 nM and is linear between 0.3 nM and 1 microM for docetaxel. For paclitaxel, the LLOQ was 1 nM, and the assay is linear between 1 nM and 1 microM. We demonstrated the suitability of this assay for docetaxel by using it to quantify the docetaxel concentrations in plasma of a patient given 40 mg/m(2) of docetaxel and comparing those results to results produced when the same samples were assayed with an HPLC assay using absorbance detection. In a similar manner, the suitability of the assay for paclitaxel was demonstrated by using it to quantify the concentrations of paclitaxel in the plasma of a patient given 15 mg/m(2) of paclitaxel and comparing those results to results produced when the same samples were assayed with an HPLC assay using absorbance detection. The LC-MS assay, which proved superior because of its greater sensitivity and relatively short (7 min) run time, should be an important tool for future pharmacokinetic analyses of docetaxel and paclitaxel.  相似文献   

4.
Profiling changes in the concentration of functionally related peptide hormones is critical to understanding the etiology of many diseases and therapies. We present novel data using nano liquid chromatography-mass spectrometry (LC-MS) to simultaneously measure a select group of vasoactive peptides (angiotensin, bradykinin, and related hormones) in 50-μl plasma samples, enabling repeated sampling in rodent models. By chromatographically resolving target peptides and using multiple reaction monitoring to enhance MS sensitivity, linear responses down to 10−17 mol were achieved. Purification of plasma peptides by either methanol precipitation or off-line high-performance liquid chromatography (HPLC) fractionation enabled the detection of endogenous peptides and revealed approaches for enhancing recovery. As proof of principle, seven vasoactive peptides were profiled before, during, and after acute angiotensin-converting enzyme (ACE) inhibition in an anesthetized rat. Of note was an apparent 10-fold increase in vasodilatory bradykinin that reversed after drug infusion but relatively minor changes in angiotensin II levels. Targeted MS analysis used to profile functionally related peptides or other analytes will greatly enhance our ability to define the sequence of events regulating complex and dynamic physiological processes.  相似文献   

5.
A simple, sensitive and selective liquid chromatography coupled with electrospray ionization mass spectrometry (LC/ESI/MS) method for the determination of simvastatin (I) has been developed. After extraction by ethyl acetate, using lovastatin (II) as internal standard, solutes are separated on a C(18) column with a mobile phase consisting of methanol-water (9:1). Detection is performed on an atmospheric pressure ionization single quadruple mass spectrometer equipped with an ESI interface and operates in positive ionization mode. Simvastatin quantification was realized by computing peak area ratio (I/II) of the extracts analyzed in SIM mode (m/z: 441 and m/z: 427 for I and II, respectively) and comparing them with calibration curve (r=0.9997). Accuracy and precision for the assay were determined by calculating the intra-batch and inter-batch variation at three concentrations 0.1, 5.0, 10.0 ng/ml; the intra batch relative standard deviation (RSD) was less than 10% and ranged from 1.8 to 8.5%, respectively; the inter-batch RSD was less than 20% and ranged from 4.1 to 16.5%. The limit of detection was 0.05 ng/ml.  相似文献   

6.
A method for the quantitative determination of perhexiline and its main hydroxylated metabolites in human plasma, based on liquid chromatography-mass spectrometry (LC-MS), was developed. The method used protein precipitation with acetonitrile followed by dilution with water and subsequent direct injection of the extract into the LC-MS system. Hexadiline was used as internal standard and the intra-assay coefficients of variation were 相似文献   

7.
A sensitive method was developed to determine fexofenadine in human plasma and urine by HPLC-electrospray mass spectrometry with MDL 026042 as internal standard. Extraction was carried out on C18 solid-phase extraction cartridges. The mobile phases used for HPLC were: (A) 12 mM ammonium acetate in water and (B) acetonitrile. Chromatographic separation was achieved on a LUNA CN column (10 cm x 2.0 mm I.D., particle size 3 microm) using a linear gradient from 40% B to 60% B in 10 min. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH+ ions, m/z 502.3 for fexofenadine and m/z 530.3 for the internal standard. The limit of quantification achieved with this method was 0.5 ng/ml in plasma and 1.0 ng in 50 microl of urine. The method described was successfully applied to the determination of fexofenadine in human plasma and urine in pharmacokinetic studies.  相似文献   

8.
Carboplatin is a platinum analogue that is used in a number of chemotherapeutic regimens for solid tumors, such as lung and ovarian carcinomas. Most often characterization of carboplatin's pharmacokinetic properties is based on measurement of platinum, rather than intact carboplatin. We have developed a sensitive LC-MS method for the determination of intact carboplatin in plasma ultrafiltrate and in tumor tissue. Carboplatin was extracted from rat plasma ultrafiltrate and tumor samples using solid-phase extraction cartridges and analyzed using reversed-phase chromatography with positive electrospray ionization followed by mass spectrometric detection. Using 50 microliter of plasma ultrafiltrate or 140 microliter of tumor homogenate supernatant, the extraction afforded a recovery of 58.7 and 45.8% for plasma and tumor, respectively. The mobile phase was 5% acetonitrile in 0.5% acetic acid at 0.2 ml/min that yielded a retention time of carboplatin of 2.2 min. The method has been validated at carboplatin plasma ultrafiltrate concentrations from 0.07 to 2.5 microgram/ml, and from 0.03 to 1.3 microgram/ml in tumor homogenates. The main advantages of this method compared with earlier methods are the ability to measure intact carboplatin in a sensitive and specific manner.  相似文献   

9.
A sensitive and selective liquid chromatographic method coupled with mass spectrometry (LC-MS) was developed for the quantification of phloroglucinol in human plasma. Resorcinol was used as internal standard, with plasma samples extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase. The reconstituted samples were injected into a C(18) XTerra MS column (2.1 x 100 mm) with 3.5-microm particle size. The analytical column lasted for at least 500 injections. The mobile phase was 15% acetonitrile (pH 3.0), with flow-rate at 200 microl/min. The mass spectrometer was operated in negative ion mode with selective ion monitoring (SIM). Phloroglucinol was detected without severe interferences from plasma matrix when used negative ion mode. Phloroglucinol produced a parent molecule ([M-H](-)) at m/z 125 in negative ion mode. Detection of phloroglucinol in human plasma was accurate and precise, with quantification limit at 5 ng/ml. This method has been successfully applied to a study of phloroglucinol in human specimens.  相似文献   

10.
Rimonabant is the first therapeutically relevant cannabinoid antagonist, licensed in Europe for treatment of obesity when a risk factor is associated. The objective of this study was to develop and validate a method for measurement of rimonabant in human plasma and hair using liquid chromatography coupled to mass spectrometry (LC-MS/MS). Rimonabant and AM-251 (internal standard) were extracted from 50muL of plasma or 10mg of hair using diethylether. Chromatography was performed on a 150mmx2.1mm C18 column using a mobile phase constituted of formate buffer/acetonitrile. Rimonabant was ionized by electrospray in positive mode, followed by detection with mass spectrometry. Data were collected either in full-scan MS or in full-scan MS/MS mode, selecting the ion m/z 463.1 for rimonabant and m/z 555.1 for IS. The most intense product ion of rimonabant (m/z 380.9) and IS (m/z 472.8) were used for quantification. Calibration curves covered a range from 2.5 (lower limit of quantification) to 1000.0ng/mL (upper limit of quantification) in plasma and from 2.5 to 1000.0pg/mg in hair. Validation results demonstrated that rimonabant could be accurately and precisely quantified in both matrixes: accuracy and precision were within 85-115% and within 15% of standard deviation, respectively. Stability studies in plasma showed that rimonabant was stable during the assay procedure, but a 30% decrease was observed for one concentration after 3 weeks at -20 degrees C. This simple and robust LC-MS/MS method can be used for measuring rimonabant concentrations in human plasma and hair either in clinical or in forensic toxicology.  相似文献   

11.
Paclitaxel is an anticancer agent extracted from the bark of the yew tree and is widely used in chemotherapy for solid tumors, including non-small cell lung cancer and ovarian carcinoma. Most assays to measure paclitaxel in plasma require a large amount of sample (0.4-1 ml) to achieve the necessary sensitivity, and are not suitable when only small sample sizes are available. To circumvent this latter limitation, we developed a sensitive liquid chromatography-mass spectrometry (LC-MS) method for the determination of paclitaxel in plasma based on the use of small sample volumes (50 microl plasma). A solid phase extraction procedure was employed that enabled the eluent to be directly injected onto a reversed phase chromatographic HPLC system using positive electrospray ionization followed by mass spectrometric detection. The extraction recoveries of paclitaxel were 98 and 83% from plasma and brain tissues, respectively. The mobile phase consisted of 50% acetonitrile in 0.1% formic acid that was pumped at 0.2 ml/min to yield a retention time for paclitaxel of 6.2 and 5.4 min for cephalomannine, the internal standard. The method has been validated at paclitaxel plasma concentrations from 0.036 to 9.9 microg/ml, and from 0.054 to 1.96 microg/ml in brain homogenates. A sensitive and specific assay for paclitaxel has been developed that has the advantages of using small sample sizes, and a single extraction step without solvent evaporation.  相似文献   

12.
13.
This paper describes a simple, fast and sensitive liquid chromatography-mass spectrometry method for quantification of an anti-thrombocythemic agent, anagrelide in human plasma. The samples were subjected to a liquid-liquid extraction after addition of a buffer and an internal standard. Chromatography was performed on an Inertsil ODS2 column and the extract was injected onto a HPLC system coupled with mass spectrometric detection. Linear responses for standards were observed from 50 to 7500 pg/ml. The accuracy of intra-assay and inter-assay were in the ranges 4.3-4.4% and 4.8-5.6%, respectively. The method is simple and reproducible with a run time of less than 2 min.  相似文献   

14.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

15.
A new high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assay for cediranib, a tyrosine kinase inhibitor for VEGFRs, was developed and validated, for the determination of plasma and brain levels of cediranib in small specimen volumes. Tyrphostin (AG1478) was used as internal standard. Mouse plasma and brain homogenate samples were prepared using liquid-liquid extraction. The assay was validated for a 2.5-2500 ng/mL concentration range for plasma, and for 1-2000 ng/mL range for brain homogenate. For these calibration ranges, within-assay variabilities were 1.1-14.3% for plasma and 1.5-9.4% for brain homogenate; between-assay variabilities were 2.4-9.2% for plasma, and 4.9-10.2% for brain homogenate. Overall accuracy ranged from 101.5 to 107.0% for plasma and 96.5 to 100.2% for brain homogenate, for all target concentrations. The developed assay has been successfully applied for a brain distribution study in mice at an oral dose of 5 mg/kg.  相似文献   

16.
24S-Hydroxycholesterol (24S-OH-Chol) and 27-hydroxycholesterol (27-OH-Chol) are oxidized derivatives of cholesterol and of potential diagnostic interest because their circulating levels may reflect the cholesterol metabolism of the brain and macrophages, respectively. We developed a sensitive and specific HPLC-MS method for the quantification of 24S-OH-Chol and 27-OH-Chol in human plasma. In contrast to currently available procedures based on gas chromatography-mass spectrometry, this methodology offers the advantage that no time-consuming derivatization is needed. After saponification, solid-phase extraction, and HPLC separation under reversed-phase column conditions, detection by MS was performed using atmospheric pressure chemical ionization and selected ion monitoring mode. The standard curves were linear throughout the calibration range for both oxysterols. Within-day and between-day coefficients of variation were less than 9%, and the recoveries ranged between 98% and 103%. The quantification limits were 40 and 25 microg/l for 24S-OH-Chol and 27-OH-Chol, respectively. Mean values for both oxysterols were determined in plasma from 22 healthy volunteers. The sensitive and selective HPLC-MS method described here combined with the appropriate workup procedure allow the quantification of 24S-OH-Chol and 27-OH-Chol in plasma samples, for example in clinical studies to elaborate the clinical usefulness of these two oxysterols.  相似文献   

17.
A rapid and specific liquid chromatographic mass spectrometric (LC-MS-MS) method has been developed for the determination of paroxetine in human plasma. The procedure involves a liquid-liquid extraction of paroxetine and fluoxetine (internal standard) with cyclohexane-ethyl acetate. The standard curve was linear over a working range of 0.2-50 ng/ml. The lower limit of quantitation was 0.2 ng/ml. No endogenous compounds were found to interfere with the analysis. The absolute recovery was 70.8% for paroxetine and 84.1% for the internal standard. The accuracy of inter-assay and intra-assay accuracy was in the ranges -4.8 to -0.5% and -3.4 to 4.8%, respectively. This method proved to be suitable for bioequivalence studies by being simple, selective and reproducible.  相似文献   

18.
Type-2 diabetes is a disorder characterized by disrupted insulin production leading to high blood glucose levels. To control this disease, combination therapy is often used. Hypoglycemic agents such as metformin, glipizide, glyburide, repaglinide, rosiglitazone, nateglinide, and pioglitazone are widely prescribed to control blood sugar levels. These drugs provide the basis for the development of a quantitative multianalyte bioanalytical method. As an example, a highly sensitive and selective multi-drug method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. This rapid, automated method consists of protein precipitation of 20 microL of plasma coupled with gradient HPLC elution of compounds using 10 mM ammonium formate buffer and 0.1% formic acid in acetonitrile as the mobile phases. MS/MS detection was performed using turbo ion spray in the positive ion multiple reaction monitoring (SRM) mode. A lower limit of quantitation (LLQ) in a range of 1.0-5.0 ng/mL was achieved for all analytes. The linearity of the method was observed over a 500-fold dynamic range. Drug recoveries ranged from 86.2 to 94.2% for all analytes of interest. Selectivity, sample dilution, intra-day and inter-day accuracy and precision, and stability assessment were evaluated for all compounds.  相似文献   

19.
A sensitive and accurate liquid chromatographic-electrospray mass spectrometric (LC-ES-MS) method for the determination of haloperidol (H) and reduced haloperidol (RH) in human plasma is presented, using chlorohaloperidol as the internal standard. A 2-ml volume of plasma subjected to basic (NaOH) extraction, acid (HCl) back-extraction, acid wash and basic (NaOH) re-extraction. The extraction solvent was hexane-isoamyl alcohol (99:1, v/v) for the whole procedure. A Nucleosil C18 column (150×1 mm) was used for high-performacne liquid chromatography, together with 2 mM HCOONH4-acetonitrile (55:45, v/v; pH 3.0) as the mobile phase. For each drug, four characteristic ions were monitored. Linearity was assessed in the ranges 0.1–50 and 0.25–50 ng/ml for H and RH, respectively. Recoveries were 58 and 70% and detection limits were 0.075 and 0.100 ng/ml for H and RH, respectively. Correlation coefficients were better than 0.999 for both compounds. R.S.D.s for repeatability and reproducibility at 0.25 ng/ml were 11.1 and 8.5% for H and 9.4 and 11.2% for RH, respectively. One of the main advantages of (LC-ES-MS) over other detection systems is the increase in selectivity obtained by monitoring three ions of confirmation for each of the drugs.  相似文献   

20.
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the quantification of metacavir in rat plasma using tinidazole as an internal standard (I.S.). Following ethyl acetate extraction, the analytes were separated on a Shim-pack ODS (4.6 microm, 150 mm x 2.0 mm I.D.) column and analyzed in selected ion monitoring (SIM) mode with a positive ESI interface using the respective [M+H](+) ions, 266 for metacavir and 248 for tinidazole. The method was validated over the concentration range of 1-600 ng/mL for metacavir. Between and within-batch precisions (R.S.D.%) were all within 15% and accuracy (%) ranged from 92.2 to 105.8%. The lower limit of quantification (LLOQ) was 1 ng/mL. The extraction recovery was on average 89.8%. The validated method was used for the pharmacokinetic study of metacavir in rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号