首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
4.
5.
A sensitive and reproducible high performance liquid chromatography (HPLC)-UV method for determination of nicousamide, an inhibitor of rennin and transforming growth factor-beta1 (TGF-beta1) type II receptors, has been developed and validated. Following acetonitrile deproteiniation, samples were separated by isocratic reversed-phase HPLC on an Aichrom Bond-AQ C(18) column and quantified using UV detection at 320 nm. The mobile phase was acetonitrile/water (ratio 62:38 containing 0.1% H(3)PO(4)), with a flow-rate of 1.0 ml/min. A linear curve over the concentration range 5-200 ng/ml (r(2)=0.9978) was obtained. The coefficients of the variation for the intra- and inter-day precisions ranged from 1.4-10.7% and 1.8-7.1%, respectively. The percentage of relative recovery was 91.56-105.45%. The method was used to determine the plasma concentration-time profiles for nicousamide after oral doses of 30, 100 and 300 mg/kg in dogs. A nonlinear pharmacokinetics was found in dogs at doses from 30 to 300 mg/kg. Following 30 mg/kg oral dose, the C(max) and AUC in females were lower than that in male. There is a potential for accumulation in dogs following multiple doses.  相似文献   

6.
7.
8.
Acetylation of the hydroxyl group in 20α-hydroxy-4--pregnen-3-one decreases the binding capacity of the molecule to transcortin to only 1% of that of progesterone. By this simple procedure it is possible to eliminate the influence of 20α-hydroxy-4-pregnen-3-one in determinations of progesterone concentrations by the competitive protein--binding method, which is highly desirable when a great number of samples are analyzed.  相似文献   

9.
A new spectrofluorimetric method to determine losartan potassium (LP) in rabbit plasma is described. The method was based on measuring the native fluorescence of LP in acidic medium. Optimum excitation and emission wavelengths were found to be 248 nm and 410 nm, respectively, in methanol that was diluted with a sulfurous acid solution LP was extracted from rabbit plasma by methyl‐tertiary‐butyl‐ether in acidic media and then back extracted with NaOH. The calibration curves were linear between 0.025 and 0.5 µg/mL with a lower limit of detection 0.004 µg/mL. Precision and accuracy values of the method were calculated as lower than 4.97% and ± 5.68, respectively and the recovery of LP from rabbit plasma was higher than 91.1%. In addition, stability studies of LP in rabbit plasma were carried out and demonstrated its good stability at − 20 °C and at room temperature. The developed and validated method was successfully applied for estimating the pharmacokinetic parameters of LP following oral administrations of a single 10 mg LP/kg to rabbits and it could be concluded that the method can be applied to clinical trials. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
11.
12.
A sensitive high‐performance liquid chromatographic (HPLC) method was developed for the determination of nizatidine in human plasma. Nizatidine was derivatized by 4‐fluoro‐7‐nitrobenzofurazan (NBD‐F). Chromatographic separation was performed on a Inertsil C18 column (150 mm × 4.6 mm, 5 µm) using isocratic elution by a mobile phase consisting of methanol/water (55:45) at a flow rate of 1.2 mL/min. Amlodipine was used as the internal standard (IS). Fluorescence detector was used operated at 461 nm (excitation) and 517 nm (emission), respectively. The calibration curve was linear over the range of 50–2000 ng/mL. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (150 mg) of nizatidine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
An enzymatic assay was developed for the spectrophotometric determination of glycolate in urine and plasma. Glycolate was first converted to glyoxylate with glycolate oxidase, and the glyoxylate formed was condensed with phenylhydrazine. The glyoxylate phenylhydrazone formed was then oxidized with K(3)Fe(CN)(6) in the presence of excess phenylhydrazine, and A(515) of the resulting 1, 5-diphenylformazan was measured. Since glycolate oxidase also acts on glyoxylate and L-lactate, the incubation of samples with glycolate oxidase was carried out in 120-170 mM Tris-HCl (pH 8.3) to obtain glyoxylate as its adduct with Tris. The pyruvate formed from lactate was removed by subsequent brief incubation with alanine aminotransferase in the presence of L-glutamate, and alpha-ketoglutarate formed was converted back to L-glutamate by glutamate dehydrogenase and an NADPH generating system. Thus the specificity of the assay relies principally on the substrate specificity of glycolate oxidase, and high sensitivity is provided by the high absorbance of 1,5-diphenylformazan at 515-520 nm. Plasma was deproteinized with perchloric acid, and then neutralized with KOH. Plasma and urine samples were then incubated with approximately 5 mM phenylhydrazine, and then treated with stearate-deactivated activated charcoal to remove endogenous keto and aldehyde acids as their phenylhydrazones. The normal plasma glycolate and urinary glycolate/creatinine ratio for adults determined by this method are approximately 8 microM and approximately 0.036, respectively.  相似文献   

14.
A simple and sensitive high-performance liquid chromatographic (HPLC) method utilizing fluorescence detection was developed for the determination of the phosphodiesterase type 5 inhibitor tadalafil in mouse plasma. This method utilizes a simple sample preparation (protein precipitation) with high recovery of tadalafil (∼98%), which eliminates the need for an internal standard. For constituent separation, the method utilized a monolithic C18 column and a flow rate of 1.0 mL/min with a mobile phase gradient consisting of aqueous trifluoroacetic acid (0.1% TFA in deionized water pH 2.2, v/v) and acetonitrile. The method calibration was linear for tadalafil in mouse plasma from 100 to 2000 ng/mL (r > 0.999) with a detection limit of approximately 40 ng/mL. Component fluorescence detection was achieved using an excitation wavelength of 275 nm with monitoring of the emission wavelength at 335 nm. The intra-day and inter-day precision (relative standard deviation, RSD) values for tadalafil in mouse plasma were less than 14%, and the accuracy (percent error) was within −14% of the nominal concentration. The method was utilized on mouse plasma samples from research evaluating the potential cardioprotective effects of tadalafil on mouse heart tissue exposed to doxorubicin, a chemotherapeutic drug with reported cardiotoxic effects.  相似文献   

15.
  • 1.1. A method is described for the accurate and rapid measurement of protein- and non-protein-bound cortisol by miniature gel filtration in small volumes of plasma, e.g. of rodents.
  • 2.2. Binding of cortisol by guinea pig plasma proteins is strongly reduced at elevated temperature (4°C: 102 ± 12ng/ml; 40°C: 5 ± 2 ng/ml).
  • 3.3. Incubation of guinea pig plasma with 1–5000 ng cortisol resulted in a dose-dependent increase in cortisol bound to proteins (specific binding by corticosteroid binding globulin: 230 ± 12 ng/ml).
  • 4.4. Administration of 20 IU (1–24)ACTH induced a significant increase of total protein-bound and non-protein-bound cortisol.
  • 5.5. Values reported in this study agree well with those of previous investigations, in which bound and non-bound glucocorticosteroids were separated by gel filtration on large Sephadex® columns.
  相似文献   

16.
A rapid and accurate spectrofluorimetric method for the determination of pomalidomide was developed and validated based on the measurement of its native fluorescence without the need for any derivatization and separation for the first time. The fluorescence intensity of the drug in acetonitrile solution allowed precise detection at 460 nm after excitation at 296 nm. The calibration curve was linear in the concentration range 31.0–500.0 ng/ml. Limit of detection and limit of quantification were found to be 8.04 and 24.36 ng/ml, respectively. Sensitive results allowed the drug to be detected with good recovery (75.46–109.72%) in human plasma and urine using the developed method. The proposed method was validated in terms of linearity, sensitivity, precision, accuracy, recovery, and stability parameters. Pomalidomide was subjected to degradation under various stress conditions (hydrolytic, oxidative and thermal) to demonstrate that the method was stable, indicating and identifying possible degradation products. In addition, the drug was exposed to electrochemical degradation using the chronoamperometry technique for the first time. Characterization of pomalidomide degradation products obtained because of oxidative degradation and electrochemical degradation was carried out using attenuated total reflection Fourier transform infrared spectroscopy, mass spectrometry and high performance liquid chromatography ? mass spectrometry methods and possible structures were proposed.  相似文献   

17.
18.
A sensitive and specific liquid chromatography-tandem mass spectrometric (LC-MS-MS) method has been developed to determine m-nisoldipine in rat plasma. Sample was pretreated by a single-step protein precipitation with acetonitrile, in contrast to the liquid-liquid procedure frequently used for the extraction of 1,4-dihydropyridines from biologic samples. Separation of analyte and internal standard (I.S.) was performed on a Symmetry RP-C(18) analytic column (50 mm x 4.6 mm, 3.5 microm) with a mobile phase consisting of acetonitrile-water (80:20, v/v) at a flow rate of 0.5 ml/min. The API 4000 triple quadrupole mass spectrometer was operated in multiple reaction monitoring (MRM) scan mode using TurboIonSpray ionization (ESI) source. The method was sensitive with a lower limit of quantification (LLOQ) of 0.2 ng/mL, with good linearity (r>or=0.9982) over the linear range of 0.2-20 ng/mL. All the validation data, such as accuracy, precision, and inter-day repeatability, were within the required limits. The method was successfully applied to pharmacokinetic and relative bioavailability studies of m-nisoldipine polymorphs in rats.  相似文献   

19.
A method is proposed for the determination of nicotine and cotinine in human urine, plasma and saliva. Nicotine and cotinine were extracted from alkalinized sample with ethyl ether and concentrated to minimum volume with nitrogen stream. The volatility of nicotine was prevented by the addition of acetic acid to the organic solvent during evaporation. Peak shapes and quantitation of nicotine and cotinine are excellent, with linear calibration curves over a wide range of 1-10,000 ng/ml. The detection limits of nicotine and cotinine are 0.2 ng/ml in urine and 1.0 ng/ml in plasma and saliva. The intra-day precision of nicotine and cotinine in all samples was <5% relative standard deviation (RSD). Urine, plasma and saliva samples of 303 non-smoking and 41 smoking volunteers from a girl's high school in Korea were quantified by the described procedure. As a result, the concentrations of nicotine and cotinine in plasma ranged from 6 to 498 ng/ml and 4 to 96 ng/ml. Otherwise, those of nicotine and cotinine in saliva ranged from 0 to 207 ng/ml and 0 to 42 ng/ml, and those of nicotine and cotinine in urine ranged from 0 to 1,590 ng/ml and 0 to 2,986 ng/ml, respectively. We found that the concentration of cotinine in plasma was successfully predicted from the salivary cotinine concentration by the equation y=2.31x+4.76 (x=the concentration of cotinine in saliva, y=the concentration of cotinine in plasma). The results show that through the accurate determination of cotinine in saliva, the risk of ETS-exposed human can be predicted.  相似文献   

20.
An analytical method based on high-performance liquid chromatographic (HPLC) was developed for the determination of montelukast in human plasma using mefenamic acid as an internal standard. After precipitation of plasma proteins with acetonitrile, chromatographic separation was carried out using a Zorbax Eclipse XDB C8 (150 mm x 4.6 mm i.d., 5 microm) with mobile phase consisted of methanol-acetonitrile-0.04M disodium hydrogen orthophosphate (22:22:56, v/v, pH 4.9). The wavelengths of fluorescence detection were set at 350 nm for excitation and 450 nm for emission. The linearity was confirmed in the concentration range of 5-1000 ng/ml in human plasma. Intra- and inter-day accuracy determined from quality control samples were 101.50 and 107.24%, and 97.15 and 100.37%, respectively. Intra- and inter-day precision measured as coefficient of variation were < or =4.72 and < or =9.00%, respectively. Extraction recoveries of drug from plasma were >48.14%. The protocol herein described was employed in a pharmacokinetic study of tablet formulation of montelukast in healthy Thai male volunteers.  相似文献   