首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Many water utilities are required to monitor source water for the presence of total coliforms, fecal coliforms, or both. The Colilert system, an application of the defined substrate technology, simultaneously detects the presence of both total coliforms and Escherichia coli directly from a water sample. After incubation, the formula becomes yellow if total coliforms are present and fluorescent at 366 nm if E. coli is in the same sample. No confirmatory tests are required. The Colilert system was previously assessed with distribution water in a national evaluation in both most-probably-number and presence-absence formats and found to produce data equivalent to those obtained by using Standard Methods for the Examination of Water and Wastewater (Standard Methods). The Colilert system was now compared with Standard Methods multiple-tube fermentation (MTF) for the enumeration of total coliforms and E. coli from surface water. All MTF tubes were confirmed according to Standard Methods, and subcultures were made to identify isolates to the species level. The Colilert system was found equally sensitive to MTF testing by regression, t test, chi-square, and likelihood fraction analyses. Specificity of the Colilert system was shown by the isolation of a species of total coliform or E. coli after the appropriate color change. The Colilert test can be used for source water samples when enumeration is required, and the benefits previously described for distribution water testing--sensitivity, specificity, less labor, lower cost, faster results, no noncoliform heterotroph interference--are applicable to this type of water analysis.  相似文献   

2.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

3.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

4.
AIMS: The reference methods for enumeration of total coliforms and Escherichia coli as stated in the European Drinking Water Directive were compared with alternative methods. METHODS AND RESULTS: Laboratories used the reference method on Lactose TTC agar (LTTC), the Colilert/18 system, Laurysulphate Agar (LSA), Chromocult Coliform Agar and the E. coli Direct Plating (DP) method. They enumerated more total coliforms on LTTC than on LSA. CONCLUSIONS: LTTC is suitable for analysis of very clean water samples only, due to heavy background growth. Colilert/18 is a good alternative but it enumerates a broader group of total coliforms, resulting in higher counts. The DP method appeared to be the best choice for enumeration of E. coli because Colilert/18 produces lower counts and false-negative results. SIGNIFICANCE AND IMPACT OF THE STUDY: This study shows the limitations of the EU reference method on LTTC due to lack of selectivity and suggests alternative methods for the enumeration of total coliforms and E. coli.  相似文献   

5.
A rapid, defined substrate technology method, commercially available as Colilert, simultaneously enumerates total coliforms and Escherichia coli in drinking water samples in 24 h without the need for confirmatory tests. The ability of this method to enumerate both total coliforms and E. coli in simulated chlorine-treated drinking water samples was compared with the standard UK method (minerals-modified glutamate most probable number) which requires up to 96 h to complete including confirmation. Statistical analysis by a nonparametric matched-pair test showed the Colilert method to be less efficient at detecting down to one E. coli in these samples compared to the standard UK method. No statistically significant difference between the two methods of enumeration for total coliforms was detected.  相似文献   

6.
A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.  相似文献   

7.
A defined substrate method was developed to simultaneously enumerate total coliforms and Escherichia coli from drinking waters without the need for confirmatory or completed tests. It is a new method based on technology that uses a hydrolyzable substrate as a specific indicator-nutrient for the target microbes. No equipment other than a 35 degrees C incubator and long-wavelength (366-nm) light is necessary. To perform the test, one only has to add water to the powdered ingredients in a tube or flask. If total coliforms are present in the water sample, the solution will change from its normal colorless state (no target microbes present) to yellow. The specific presence of E. coli will cause the same tube to fluoresce under a longwave (366-nm) UV lamp. The test, called Autoanalysis Colilert (AC), was compared with Standard Methods for the Examination of Water and Wastewater 10-tube multiple tube fermentation (MTF) in a national evaluation. Five utilities, representing six U.S. Environmental Protection Agency regions, participated. All water samples came from distribution systems. Split samples from a wide variety of water sources were analyzed for the MPN-versus-MPN comparison. A total of 1,086 tubes were positive by MTF, and 1,279 were positive by AC. There was no statistical difference between MTF and AC. Species identifications from positive tubes confirmed the sensitivity of the AC. A national evaluation of the AC test showed that it: (i) was as sensitive as Standard Methods MTF, (ii) specifically enumerated 1 total coliform per 100 ml, in a maximum of 24 h, (iii) simultaneously enumerated 1 E. coli per 100 ml in the same analysis, (iv) was not subject to false-positive or false-negative results by heterotrophic bacteria, (v) did not require confirmatory tests, (vi) grew injured coliforms, (vii) was easy to inoculate, and (viii) was very easy to interpret.  相似文献   

8.
The current investigation was carried out in order to compare directly the multiple tube fermentation method (MTF), using standard procedures (lactose broth, LB) and the Colilert reagent, with the membrane filter method (MF) using Les Endo agar (LEA), m-faecal coliform agar (mFCA) and chromogenic coliform agar (CCA), for recovery of coliforms and Escherichia coli in 80 surface water samples. Total coliforms were isolated from 100% of samples by all methodologies. Faecal coliforms/E. coli were detected in 100% of samples by MTF methods, but only in 75.5% by MF-mFCA and in 86.2% by MF-CCA. Even if MTF-LB counts were consistently higher, the Colilert reagent accurately determined total coliforms and E. coli levels within 24 h with no additional confirmatory tests. Therefore, it could be a powerful tool for rapidly assessing possible faecal contamination and a suitable alternative to the traditional MTF and MF techniques utilized for coliform detection.  相似文献   

9.
Aim: A new medium, EC‐Blue‐10, containing chromogenic and fluorogenic substrates, KNO3 and sodium pyruvate has been developed for the rapid simultaneous detection and enumeration of total coliforms and Escherichia coli in water. Methods and Results:  Two evaluations of EC‐Blue‐10 were carried out. Firstly, EC‐Blue‐10 was compared with Colilert‐MPN for 96 water samples using MPN for total coliforms and E. coli. Secondly, the detection of coliforms and E. coli were compared using 2400 tubes of EC‐Blue‐10 and Colilert‐MPN. The regression coefficients between EC‐Blue‐10 and Colilert‐MPN for total coliforms and E. coli were 0·91 and 0·89, respectively. For the detection results, the Cohen’s kappa values between the two media were 0·79 for coliforms and 0·72 for E. coli. Conclusions: EC‐Blue‐10 is almost same as Colilert‐MPN for the detection of coliforms and E. coli in surface waters. Further evaluation for EC‐Blue‐10 is needed to verify in different geographical areas. Significance and Impact of the Study: EC‐Blue‐10 is useful method for the rapid and simultaneous detection of total coliforms and E. coli in water sample.  相似文献   

10.
This study compared the performance of LMX(R) broth (LMX), Chromocult Coliform(R) agar (CC) and Chromocult Coliform agar plus cefsulodin (10 microg ml-1) (CC-CFS), with standard methods multiple tube fermentation (MTF), for the enumeration of total coliforms and Escherichia coli from marine recreational waters. LMX and CC are two media designed to concurrently detect total coliform (TC) bacteria and E. coli by the specific action of beta-galactosidase (total coliforms) and beta-glucuronidase (E. coli). Overall results for the TC test showed that LMX, CC and MTF recovered 2.63, 1.95 and 1.90 times as many TCs as CC-CFS, respectively. Data from the multiple range test showed significant differences (P < 0.05) between TC counts on CC-CFS and LMX. The traditional MTF was less sensitive for E. coli enumeration. However, there was no statistically significant differences between LMX, CC, CC-CFS and the MTF method for E. coli enumeration. Background interference was reduced on CC-CFS and the counts obtained reflected more accurately the number of TCs. Therefore, the contribution of beta-galactosidase positive, non coliform bacteria (Aeromonas spp. and Vibrio spp.) to TC counts should not be neglected.  相似文献   

11.
Ability of the Colilert method to recover oxidant-stressed Escherichia coli   总被引:2,自引:1,他引:1  
Methods for the microbiological analysis of drinking water must be able to detect Escherichia coli that may be injured by treatment. The Colilert method, which simulaneously detects total coliforms and E. coli in water samples by the observation of direct colour changes produced by defined substrates in the media, was found to be equivalent to the reference EC MUG method in its ability to recover low numbers (< 4/100 ml) of oxidant-stressed E. coli.  相似文献   

12.
The new United States Drinking Water Regulations state that water systems must analyze for Escherichia coli or fecal coliforms on any routine or repeat sample that is positive for total coliforms. The proposed methods for the detection of E. coli are based on beta-glucuronidase activity, using the fluorogenic substrate 4-methylumbelliferyl beta-D-glucuronide (MUG). This study was conducted to determine whether beta-glucuronidase negative E. coli were present in significant numbers in environmental waters. Two hundred and forty E. coli cultures were isolated from 12 water samples collected from different environmental sources. beta-glucuronidase activity was determined using lauryl tryptose broth with MUG, EC broth with MUG, and the Autoanalysis Colilert (AC) procedure. The isolates were also evaluated by the standard EC broth gas fermentation method for fecal coliforms. The results confirm that assaying for the enzyme beta-glucuronidase utilizing the MUG substrate is an accurate method for the detection of E. coli in environmental waters.  相似文献   

13.
Colilert (Colilert), Readycult Coliforms 100 (Readycult), Chromocult Coliform agar ES (Chromocult), and MI agar (MI) are beta-galactosidase and beta-glucuronidase-based commercial culture methods used to assess water quality. Their analytical performance, in terms of their respective ability to detect different strains of Escherichia coli and total coliforms, had never been systematically compared with pure cultures. Here, their ability to detect beta-glucuronidase production from E. coli isolates was evaluated by using 74 E. coli strains of different geographic origins and serotypes encountered in fecal and environmental settings. Their ability to detect beta-galactosidase production was studied by testing the 74 E. coli strains as well as 33 reference and environmental non-E. coli total coliform strains. Chromocult, MI, Readycult, and Colilert detected beta-glucuronidase production from respectively 79.9, 79.9, 81.1, and 51.4% of the 74 E. coli strains tested. These 4 methods detected beta-galactosidase production from respectively 85.1, 73.8, 84.1, and 84.1% of the total coliform strains tested. The results of the present study suggest that Colilert is the weakest method tested to detect beta-glucuronidase production and MI the weakest to detect beta-galactosidase production. Furthermore, the high level of false-negative results for E. coli recognition obtained by all four methods suggests that they may not be appropriate for identification of presumptive E. coli strains.  相似文献   

14.
A test that allows for early detection of fecally contaminated coastal water would enhance public health protection. Colilert-Marine Water (Colilert-MW; Environetics, Branford, Conn.) is a rapid 24-h test that has recently been developed to detect total coliforms and Escherichia coli in coastal water. We performed a premarketing evaluation of the Colilert-MW product, testing it in parallel with the multiple tube fermentation (MTF) method for 86 coastal water samples in southern California. Statistical analysis was performed by using paired t tests and linear regression. Bacterial isolates were evaluated by biochemical and genetic analysis. The results of this study showed a strong correlation between the traditional MTF and the Colilert-MW method for detection of total coliforms (r = 0.95) and E. coli (r = 0.89) in ocean water samples. Paired t-test results indicated that the Colilert-MW and MTF were equivalent in detecting E. coli and that the Colilert-MW may be more sensitive in the detection of total coliforms. We conclude that Colilert-MW would be a useful tool with which to monitor coastal beach water.  相似文献   

15.
The Colilert defined substrate technology system allows specific, one-step detection of both coliforms and Escherichia coli while claiming to suppress the influence of non-coliform heterotrophs. The Colilert assay was examined in order to determine whether organisms from the genus Aeromonas could interfere and cause production of a false-positive coliform result as aquatic Aeromonas are known to constitute a fraction of the heterotrophic population found in drinking water. Results obtained clearly demonstrate that Aeromonas sp. can elicit a positive coliform type reaction at very low densities. Cell suspensions as low as 1 × 101 cells 10 ml−1 were observed to yield a positive reaction using Colilert reagent 4 weeks short of shelf-life expiry. Use of aged Colilert for monitoring water quality could lead to over-estimation of coliforms as Aeromonas have been identified in many treated drinking water supplies.  相似文献   

16.
This study was conducted to evaluate the performance of the MicroFoss system (Biosys, Ann Arbor, MI) for enumeration of total viable organisms, Escherichia coli and coliforms in ground beef. The system performance was compared to that of the USDA Bacteriological Analytical Method (BAM) reference culture methods. The correlation coefficients for the regression lines comparing the MicroFoss system detection times to the results of plate count methods for the total viable counts, coliform counts and the most probable number (MPN) method for E. coli were -0.95, -0.96 and -0.97, respectively. Tests comparing the reproducibility of data generated independently by two technicians on the same batch of samples showed no significant differences (P>0.05) in the MicroFoss detection times and culture results. The plate count methods for the total viable counts and coliform counts, and the MPN method for E. coli required 10, 11 and 22 times, respectively, the amount of time to complete tests compared to the length of time required to perform these tests using the MicroFoss system. The MicroFoss system produced reproducible data and provided a rapid and cost-efficient alternative method for enumeration of TVC, coliforms and E. coli in ground beef.  相似文献   

17.
In this work alternative media for detection and enumeration of E. coli and coliform bacteria were compared to the reference method ISO 9308-1 (LTTC) using non-disinfected water samples with background flora. The alternative media included LES Endo agar medium (LES Endo), Colilert-18 with 51-well Quanti-tray (Colilert), Chromocult Coliform agar (CC), Harlequin E. coli/Coliform medium (HECM) and Chromogenic Escherichia coli/Coliform medium (CECM). A total of 110 samples of groundwater, bathing water and spiked water was used. Our results revealed that confirmation of coliform bacteria counts is necessary, not only on lactose-based LTTC and LES Endo media, but also on the chromogenic agar media tested, due to the growth of oxidase positive colonies. LTTC and CC media also allowed the growth of some morphologically typical coliform colonies containing gram-positive bacteria. The recovery of coliform bacteria was lower on LES Endo than on LTTC. In most cases Colilert, CC, HECM and CECM gave higher coliform counts than LTTC. The use of the LTTC medium led to higher E. coli counts than obtained with any of the alternative mediums. There are three explanations for this: (1) high sensitivity of LTTC, (2) false positives on LTTC or (3) false negatives especially with Colilert, but also with chromogenic agar media. Although LTTC was found to be a very sensitive medium, the high degree of background growth of non-disinfected waters disturbed substantially the use of it. In conclusion, our results suggest that Colilert, CC and CECM are potential alternative media for detection of coliform bacteria and E. coli from non-disinfected water.  相似文献   

18.
Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents' habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.  相似文献   

19.
Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.  相似文献   

20.
C M Lewis  J L Mak 《Applied microbiology》1989,55(12):3091-3094
Over a 4-month period, 950 samples of treated drinking water were analyzed for total coliforms (TC) and Escherichia coli by both membrane filtration (MF) and Autoanalysis Colilert presence-absence (AC) techniques. The two tests agreed 97% of the time on the basis of presumptive TC results and 98.5% of the time on the basis of verified TC results. Samples which produced disagreement between the two tests were most often TC positive by MF and TC negative by AC. E. coli was recovered four times: twice by MF only, and twice by AC only but without the diagnostic fluorescence reaction. In two samples, E. coli could not be isolated from fluorescence-positive AC tests. On the basis of these results, the AC test was implemented as the routine analytical procedure for TC but not for E. coli.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号