首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Optoacoustic (photoacoustic) imaging is often performed with one‐dimensional transducer arrays, in analogy to ultrasound imaging. Optoacoustic imaging using linear arrays offers ease of implementation but comes with several performance drawbacks, in particular poor elevation resolution, i.e. the resolution along the axis perpendicular to the focal plane. Herein, we introduce and investigate a bi‐directional scanning approach using linear arrays that can improve the imaging performance to quasi‐isotropic transverse resolution. We study the approach theoretically and perform numerical simulations and phantom measurements to evaluate its performance under defined conditions. Finally, we discuss the features and the limitations of the proposed method.

The poor elevation resolution in a linear scan (left image) is overcome by the proposed bi‐directional scanning approach that yields isotropic transverse resolution (right).  相似文献   


2.
Early detection of cutaneous squamous cell carcinoma (cSCC) can enable timely therapeutic and preventive interventions for patients. In this study, in vivo nonlinear optical imaging (NLOI) based on two‐photon excitation fluorescence (TPEF) and second harmonic generation (SHG), was used to non‐invasively detect microscopic changes occurring in murine skin treated topically with 7,12‐dimethylbenz(a)anthracene (DMBA). The optical microscopic findings and the measured TPEF‐SHG index show that NLOI was able to clearly detect early cytostructural changes in DMBA treated skin that appeared clinically normal. This suggests that in vivo NLOI could be a non‐invasive tool to monitor early signs of cSCC.

In vivo axial NLOI scans of normal murine skin (upper left), murine skin with preclinical hyperplasia (upper right), early clinical murine skin lesion (lower left) and late or advanced murine skin lesion (lower right).  相似文献   


3.
Existing mammographic screening solutions are generally associated with several major drawbacks, such as exposure to ionizing radiation or insufficient sensitivity in younger populations with radiographically‐dense breast. Even when combined with ultrasound or magnetic resonance imaging, X‐Ray mammography may still attain unspecific or false positive results. Thus, development of new breast imaging tools represents a timely medical challenge. We report on a new approach to high‐resolution functional and anatomical breast angiography using volumetric hand‐held optoacoustic tomography, which employs light intensities safe for human use. Experiments in young healthy volunteers with fibroglandular‐dominated dense breasts revealed the feasibility of rendering three‐dimensional images representing vascular anatomy and functional blood oxygenation parameters at video rate. Sufficient contrast was achieved at depths beyond 2 cm within dense breasts without compromising the real‐time imaging performance. The suggested solution may thus find applicability as a standalone or supplemental screening tool for early detection and follow‐up of carcinomas in radiographically‐dense breasts.

Volumetric handheld optoacoustic tomography scanner uses safe pulses of near‐infrared light to render three‐dimensional images of deep vascular anatomy, blood oxygenation and breast parenchyma at video rate.  相似文献   


4.
The healing process of superficial skin wounds treated with a blue‐LED haemostatic device is studied. Four mechanical abrasions are produced on the back of 10 Sprague Dawley rats: two are treated with the blue‐LED device, while the other two are left to naturally recover. Visual observations, non‐linear microscopic imaging, as well as histology and immunofluorescence analyses are performed 8 days after the treatment, demonstrating no adverse reactions neither thermal damages in both abraded areas and surrounding tissue. A faster healing process and a better‐recovered skin morphology are observed: the treated wounds show a reduced inflammatory response and a higher collagen content.

Blue LED induced photothermal effect on superficial abrasions.  相似文献   


5.
Non‐invasive and quantitative estimations for the delineation of sub‐surface tumor margins could greatly aid in the early detection and monitoring of the morphological appearances of tumor growth, ensure complete tumor excision without the unnecessary sacrifice of healthy tissue, and facilitate post‐operative follow‐up for recurrence. In this study, a high‐speed, non‐invasive, and ultra‐high‐resolution spectral domain optical coherence tomography (UHR‐SDOCT) imaging platform was developed for the quantitative measurement of human sub‐surface skin mass. With a proposed robust, semi‐automatic analysis, the system can rapidly quantify lesion area and shape regularity by an en‐face‐oriented algorithm. Various sizes of nylon sutures embedded in pork skin were used first as a phantom to verify the accuracy of our algorithm, and then in vivo, feasibility was proven using benign human angiomas and pigmented nevi. Clinically, this is the first step towards an automated skin lesion measurement system.

In vivo optical coherence tomography (OCT) image of angioma (A). Thin red arrows point to a blood vessel (BV).  相似文献   


6.
The paper presents problems and solutions related to hyperspectral image pre‐processing. New methods of preliminary image analysis are proposed. The paper shows problems occurring in Matlab when trying to analyse this type of images. Moreover, new methods are discussed which provide the source code in Matlab that can be used in practice without any licensing restrictions.

The proposed application and sample result of hyperspectral image analysis.  相似文献   


7.
A study of polarized light transport in scattering media exhibiting directional anisotropy or linear birefringence is presented in this paper. Novel theoretical and experimental methodologies for the quantification of birefringent alignment based on out‐of‐plane polarized light transport are presented here. A polarized Monte Carlo model and a polarimetric imaging system were devised to predict and measure the impact of birefringence on an impinging linearly polarized light beam. Ex‐vivo experiments conducted on bovine tendon, a biological sample consisting of highly packed type I collagen fibers with birefringent property, showed good agreement with the analytical results.

Top view geometry of the in‐plane ( a ) and the out‐of‐plane ( b ) detection. Letter C indicates the location of the detection arm.  相似文献   


8.
Mechanisms of renal autoregulation generate oscillations in arterial blood flow at several characteristic frequencies. Full‐field laser speckle flowmetry provides a real‐time imaging of superficial blood microcirculation. The possibility to detect changes in oscillatory dynamics is an important issue in biomedical applications. In this paper we show how laser power density affects quality of the recorded signal and improves detectability of temporal changes in microvascular perfusion.

  相似文献   


9.
We present a hybrid dual‐wavelength optoacoustic and ultrasound bio‐microscope capable of rapid transcranial visualization of morphology and oxygenation status of large‐scale cerebral vascular networks. Imaging of entire cortical vasculature in mice is achieved with single capillary resolution and complemented by simultaneously acquired pulse‐echo ultrasound microscopy scans of the mouse skull. The new approach holds potential to facilitate studies into neurological and vascular abnormalities of the brain. Further details can be found in the article by Johannes Rebling, Héctor Estrada, Sven Gottschalk, et al. ( e201800057 ).

  相似文献   


10.
We report the development of an intravascular magnetomotive optical coherence tomography (IV‐MM‐OCT) system used with targeted protein microspheres to detect early‐stage atherosclerotic fatty streaks/plaques. Magnetic microspheres (MSs) were injected in vivo in rabbits, and after 30 minutes of in vivo circulation, excised ex vivo rabbit aorta samples specimens were then imaged ex vivo with our prototype IV‐MM‐OCT system. The alternating magnetic field gradient was provided by a unique pair of external custom‐built electromagnetic coils that modulated the targeted magnetic MSs. The results showed a statistically significant MM‐OCT signal from the aorta samples specimens injected with targeted MSs.

Representative magnetomotive signal (green) using targeted and non‐targeted magnetomotive microspheres in atherosclerotic diseased rabbit aortas.  相似文献   


11.
Despite the great promise behind the recent introduction of optoacoustic technology into the arsenal of small‐animal neuroimaging methods, a variety of acoustic and light‐related effects introduced by adult murine skull severely compromise the performance of optoacoustics in transcranial imaging. As a result, high‐resolution noninvasive optoacoustic microscopy studies are still limited to a thin layer of pial microvasculature, which can be effectively resolved by tight focusing of the excitation light. We examined a range of distortions introduced by an adult murine skull in transcranial optoacoustic imaging under both acoustically‐ and optically‐determined resolution scenarios. It is shown that strong low‐pass filtering characteristics of the skull may significantly deteriorate the achievable spatial resolution in deep brain imaging where no light focusing is possible. While only brain vasculature with a diameter larger than 60 µm was effectively resolved via transcranial measurements with acoustic resolution, significant improvements are seen through cranial windows and thinned skull experiments.

(a) Experimental setup for hybrid acoustic and optical resolution optoacoustic microscopy. (b) Transcranial scan of an adult mouse brain using the optical resolution mode. Scale bar is 375 µm.  相似文献   


12.
Flow cytometry provides a high throughput, multi‐dimensional analysis of cells flowing in suspension. In order to combine this feature with the ability to resolve detailed structures in 3D, we developed an optofluidic device that combines a microfluidic system with a dual beam trap. This allows for the rotation of single cells in a continuous flow, around an axis perpendicular to the imaging plane. The combination of both techniques enables the tomographic reconstruction of the 3D structure of the cell. In addition this method is capable to provide detailed 3D structural data for flow cytometry, as it improves the reconstructed z‐resolution of a standard microscopy system to produce images with isotropic resolution in all three axes.

  相似文献   


13.
Raman spectral imaging is gaining more and more attention in biological studies because of its label‐free characteristic. However, the discrimination of overlapping chemical contrasts has been a major challenge. In this study, we introduce an optical method to simultaneously obtain two orthogonally polarized Raman images from a single scan of the sample. We demonstrate how this technique can improve the quality and quantity of the hyperspectral Raman dataset and how the technique is expected to further extend the horizons of Raman spectral imaging in biological studies by providing more detailed chemical information.

The dual‐polarization Raman images of a HeLa cell.  相似文献   


14.
Polarimetric measurements in multiphoton microscopy can reveal information about the local molecular order of a sample. However, the presence of a dichroic through which the excitation beam propagates will generally scramble its polarization. We propose a simple scheme whereby a second properly‐oriented compensation dichroic is used to negate any alteration regardless of the wavelength and the initial polarization. We demonstrate how this robust and rapid approach simplifies polarimetric measurements in second‐harmonic generation, two‐photon excited fluorescence and coherent anti‐Stokes Raman scattering.

Illustration of the polarization maintaining strategy with the compensating dichroic oriented such that its s‐ and p‐axes are interchanged with these of the primary dichroic.  相似文献   


15.
Biological tissues are very strong light‐scattering media. As a consequence, current medical imaging devices do not allow deep optical imaging unless invasive techniques are used. Acousto‐optic imaging is a light‐ultrasound coupling technique that takes advantage of the ballistic propagation of ultrasound in biological tissues to access optical contrast with a millimeter resolution. We have developed a photorefractive‐crystal‐based system that performs self‐adaptive wavefront holography and works within the optical therapeutic window. As it works at an appropriate wavelength range for biological tissues imaging, it was tested on ex vivo liver samples containing tumors as a pre‐clinical study. Optical contrast was obtained even if acoustical one was not significant.

Ultrasound image (left) and acousto‐optic image (right) of a liver biopsy with tumors. Acousto‐optic imaging exhibits tumors that are not detected through ultrasound.  相似文献   


16.
Molecular optoacoustic (photoacoustic) imaging typically relies on the spectral identification of absorption signatures from molecules of interest. To achieve this, two or more excitation wavelengths are employed to sequentially illuminate tissue. Due to depth‐related spectral dependencies and detection related effects, the multispectral optoacoustic tomography (MSOT) spectral unmixing problem presents a complex non‐linear inversion operation. So far, different studies have showcased the spectral capacity of optoacoustic imaging, without however relating the performance achieved to the number of wavelengths employed. Overall, the dependence of the sensitivity and accuracy of optoacoustic imaging as a function of the number of illumination wavelengths has not been so far comprehensively studied. In this paper we study the impact of the number of excitation wavelengths employed on the sensitivity and accuracy achieved by molecular optoacoustic tomography. We present a quantitative analysis, based on synthetic MSOT datasets and observe a trend of sensitivity increase for up to 20 wavelengths. Importantly we quantify this relation and demonstrate an up to an order of magnitude sensitivity increase of multi‐wavelength illumination vs. single or dual wavelength optoacoustic imaging. Examples from experimental animal studies are finally utilized to support the findings.

In vivo MSOT imaging of a mouse brain bearing a tumor that is expressing a near‐infrared fluorescent protein. ( a ) Monochromatic optoacoustic imaging at the peak excitation wavelength of the fluorescent protein. ( b ) Overlay of the detected bio‐distribution of the protein (red pseudocolor) on the monochromatic optoacoustic image. ( c ) Ex vivo validation by means of cryoslicing fluorescence imaging.  相似文献   


17.
In this study, sensor surface functionalization allowing the repetitive use of a sensing device was evaluated for antibody‐based detection of living bacteria using an optical planar Bragg grating sensor. To achieve regenerable immobilization of bacteria specific antibodies, the heterobifunctional cross‐linker N‐succinimidyl 3‐(2‐pyridyldithio) propionate (SPDP) was linked to an aminosilanized sensor surface and subsequently reduced to expose sulfhydryl groups enabling the covalent conjugation of SPDP‐activated antibodies via disulfide bonds. The immobilization of a capture antibody specific for Staphylococcus aureus on the sensor surface as well as specific binding of S. aureus could be monitored, highlighting the applicability of optical sensors for the specific detection of large biological structures. Reusability of bacteria saturated sensors was successfully demonstrated by cleaving the antibody along with bound bacteria through reduction of disulfide bonds and subsequent re‐functionalization with activated antibody, resulting in comparable sensitivity towards S. aureus.

  相似文献   


18.
We use terahertz imaging to measure four human skin scars in vivo. Clear contrast between the refractive index of the scar and surrounding tissue was observed for all of the scars, despite some being difficult to see with the naked eye. Additionally, we monitored the healing process of a hypertrophic scar. We found that the contrast in the absorption coefficient became less prominent after a few months post‐injury, but that the contrast in the refractive index was still significant even months post‐injury. Our results demonstrate the capability of terahertz imaging to quantitatively measure subtle changes in skin properties and this may be useful for improving scar treatment and management.

  相似文献   


19.
We report the enhancement in imaging performance of a spectral‐domain optical coherence microscope (OCM) in turbid media by incorporating an optical parametric amplifier (OPA). The OPA provides a high level of optical gain to the sample arm, thereby improving the signal‐to‐noise ratio of the OCM by a factor of up to 15 dB. A unique nonlinear confocal gate is automatically formed in the OPA, which enables selective amplification of singly scattered (ballistic) photons against the multiply‐scattered light background. Simultaneous enhancement in both imaging depth and spatial resolution in imaging microstructures in highly light‐scattering media are demonstrated with the combined OPA‐OCM setup.

Typical OCM inteferograms (left) and images (right) without and with OPA.  相似文献   


20.
Photoplethysmography is a well‐established technique for the noninvasive measurement of blood pulsation. However, photoplethysmographic devices typically need to be in contact with the surface of the tissue and provide data from a single contact point. Extensions of conventional photoplethysmography to measurements over a wide field‐of‐view exist, but require advanced signal processing due to the low signal‐to‐noise‐ratio of the photoplethysmograms. Here, we present a noncontact method based on temporal sampling of time‐integrated speckle using a camera‐phone for noninvasive, widefield measurements of physiological parameters across the human fingertip including blood pulsation and resting heart‐rate frequency. The results show that precise estimation of these parameters with high spatial resolution is enabled by measuring the local temporal variation of speckle patterns of backscattered light from subcutaneous skin, thereby opening up the possibility for accurate high resolution blood pulsation imaging on a camera‐phone.

Camera‐phone laser speckle imager along with measured relative blood perfusion maps of a fingertip showing skin perfusion response to a pulse pressure applied to the upper arm. The figure is for illustration only; the imager was stabilized on a stand throughout the experiments.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号