首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
BackgroundDengue is the world’s most common mosquito-borne virus but remains diagnostically challenging due to its nonspecific presentation. Access to laboratory confirmation is limited and thus most reported figures are based on clinical diagnosis alone, the accuracy of which is uncertain. This systematic review assesses the diagnostic accuracy of the traditional (1997) and revised (2009) WHO clinical case definitions for dengue fever, the basis for most national guidelines.Methodology/Principal findingsPubMed, EMBASE, Scopus, OpenGrey, and the annual Dengue Bulletin were searched for studies assessing the diagnostic accuracy of the unmodified clinical criteria. Two reviewers (NR/SL) independently assessed eligibility, extracted data, and evaluated risk of bias using a modified QUADAS-2. Additional records were found by citation network analysis. A meta-analysis was done using a bivariate mixed-effects regression model. Studies that modified criteria were analysed separately. This systematic review protocol was registered on PROSPERO (CRD42020165998). We identified 11 and 12 datasets assessing the 1997 and 2009 definition, respectively, and 6 using modified criteria. Sensitivity was 93% (95% CI: 77–98) and 93% (95% CI: 86–96) for the 1997 and 2009 definitions, respectively. Specificity was 29% (95% CI: 8–65) and 31% (95% CI: 18–48) for the 1997 and 2009 definitions, respectively. Diagnostic performance suffered at the extremes of age. No modification significantly improved accuracy.Conclusions/SignificanceDiagnostic accuracy of clinical criteria is poor, with significant implications for surveillance and public health responses for dengue control. As the basis for most reported figures, this has relevance to policymakers planning resource allocation and researchers modelling transmission, particularly during COVID-19.  相似文献   

3.
BackgroundChikungunya virus (CHIKV) causes febrile illnesses and has always been misdiagnosed as other viral infections, such as dengue and Zika; thus, a laboratory test is needed. Serological tests are commonly used to diagnose CHIKV infection, but their accuracy is questionable due to varying degrees of reported sensitivities and specificities. Herein, we conducted a systematic review and meta-analysis to evaluate the diagnostic accuracy of serological tests currently available for CHIKV.Methodology and principal findingsA literature search was performed in PubMed, CINAHL Complete, and Scopus databases from the 1st December 2020 until 22nd April 2021. Studies reporting sensitivity and specificity of serological tests against CHIKV that used whole blood, serum, or plasma were included. QUADAS-2 tool was used to assess the risk of bias and applicability, while R software was used for statistical analyses.Thirty-five studies were included in this meta-analysis; 72 index test data were extracted and analysed. Rapid and ELISA-based antigen tests had a pooled sensitivity of 85.8% and 82.2%, respectively, and a pooled specificity of 96.1% and 96.0%, respectively. According to our meta-analysis, antigen detection tests serve as a good diagnostic test for acute-phase samples. The IgM detection tests had more than 90% diagnostic accuracy for ELISA-based tests, immunofluorescence assays, in-house developed tests, and samples collected after seven days of symptom onset. Conversely, low sensitivity was found for the IgM rapid test (42.3%), commercial test (78.6%), and for samples collected less than seven of symptom onset (26.2%). Although IgM antibodies start to develop on day 2 of CHIKV infection, our meta-analysis revealed that the IgM detection test is not recommended for acute-phase samples. The diagnostic performance of the IgG detection tests was more than 93% regardless of the test formats and whether the test was commercially available or developed in-house. The use of samples collected after seven days of symptom onset for the IgG detection test suggests that IgG antibodies can be detected in the convalescent-phase samples. Additionally, we evaluated commercial IgM and IgG tests for CHIKV and found that ELISA-based and IFA commercial tests manufactured by Euroimmun (Lübeck, Germany), Abcam (Cambridge, UK), and Inbios (Seattle, WA) had diagnostic accuracy of above 90%, which was similar to the manufacturers’ claim.ConclusionBased on our meta-analysis, antigen or antibody-based serological tests can be used to diagnose CHIKV reliably, depending on the time of sample collection. The antigen detection tests serve as a good diagnostic test for samples collected during the acute phase (≤7 days post symptom onset) of CHIKV infection. Likewise, IgM and IgG detection tests can be used for samples collected in the convalescent phase (>7 days post symptom onset). In correlation to the clinical presentation of the patients, the combination of the IgM and IgG tests can differentiate recent and past infections.  相似文献   

4.
The difference in the distribution of Schistosoma eggs in the viscera has not been clearly elucidated in the two closely related species Schistosoma japonicum and Schistosoma mekongi. In this study, we quantitatively compared the distribution of eggs in mice infected with the two species. In S. mekongi-infected mice, 56.6% to 69.4% of total eggs were found in the distal small intestine 9 to 15 weeks after infection, while in S. japonicum-infected mice, 48.8% to 71.8% of eggs were found in the proximal small intestine during the same period. There were significantly more eggs in the liver in mice infected with S. japonicum than in those infected with S. mekongi. The number of adult worms recovered did not differ between the two species during the study period. The total number of eggs laid in the tissues also did not differ between the two species at 12 to 15 weeks postinfection, but in the earlier period the total number of eggs was significantly fewer in S. mekongi-infected than in S. japonicum-infected mice, suggesting the delayed maturation of the former compared with the latter. These results clearly show that S. japonicum and S. mekongi exhibit different oviposition behavior in their hosts.  相似文献   

5.

Background

Lymph node status is the key to determining the prognosis and treatment of cervical cancer. However, it cannot be assessed clinically, and testing for nodal metastasis is controversial. We sought to systematically review the diagnostic accuracy literature on sentinel node biopsy, positron emission tomography, magnetic resonance imaging and computed tomography to evaluate the accuracy of each index test in determining lymph node status in patients with cervical cancer.

Methods

We searched MEDLINE (1966–2006), EMBASE (1980–2006), Medion (1980–2006) and the Cochrane library (Issue 2, 2006) for relevant articles. We also manually searched the reference lists from primary articles and reviews, and we contacted experts in the field for conference abstracts and unpublished studies. We performed random-effects meta-analysis of accuracy indices, and we performed meta-regression analysis to test the effect of study quality on diagnostic accuracy and to identify other sources of heterogeneity.

Results

We included 72 relevant primary studies, involving a total of 5042 women, in our analysis. We found that, in determining lymph node status, sentinel node biopsy had a pooled positive likelihood ratio of 40.8 (95% confidence interval [CI] 24.6–67.6) and a pooled negative likelihood ratio of 0.18 (95% CI 0.14–0.24). The pooled positive likelihood ratios (and 95% CI) were 15.3 (7.9–29.6) for positron emission tomography, 6.4 (4.9–8.3) for magnetic resonance imaging and 4.3 (3.0–6.2) for computed tomography. The pooled negative likelihood ratios (and 95% CIs) were 0.27 (0.11–0.66) for positron emission tomography, 0.50 (0.39–0.64) for magnetic resonance imaging and 0.58 (0.48–0.70) for computed tomography. Using a 27% pretest probability of lymph node metastasis among all cases (regardless of stage), we found that a positive sentinel node biopsy result increased post-test probability to 94% (95% CI 90%–96%), whereas a positive finding on positron emission tomography increased it to 85% (75%–92%).

Interpretation

Sentinel node biopsy has greater accuracy in determining lymph node status among women with primary cervical cancer than current commonly used imaging methods.In the United States and European Union it is estimated that cervical cancer is diagnosed in about 42 000 women each year.1,2 The International Federation of Gynecology and Obstetrics criteria currently used to stage cervical cancer do not account for lymph node involvement, but the lymphatic spread of the disease is key to determining prognosis and appropriate treatment.The primary treatment options for early cervical cancer (stage 1B1 or less advanced) are surgery and chemoradiotherapy, which have similar survival rates.3 Surgical treatment offers some degree of fertility preservation and may not have the long-term complications associated with chemoradiotherapy. However, because it is not possible to clinically detect pelvic and para-aortic lymph node metastasis, surgery typically includes lymphadenectomy, which may reveal metastatic spread. In such cases, chemoradiotherapy is required, which would make the initial surgical procedure unnecessary in retrospect. There has been considerable interest in using a preoperative, noninvasive test to determine lymph node status in order to select the most appropriate treatment option. Such a test could avoid unnecessary surgical intervention, reduce morbidity and correctly direct choice of treatment.In recent years, the use of magnetic resonance imaging and computed tomography to determine lymph node status has increased; however, neither method has been formally included as part of International Federation of Gynecology and Obstetrics staging of cervical cancer. Sentinel node biopsy and positron emission tomography have emerged as competitors to magnetic resonance imaging and computed tomography. The accuracy of magnetic resonance imaging, computed tomography and positron emission tomography has been assessed previously in reviews,4–6 but updates are required because recent studies have reported on their diagnostic accuracy7 and on quality assessment in diagnostic reviews.8 Given this background, we performed a systematic review of the literature to compare the accuracy of these 4 methods in determining lymph node status in patients with cervical cancer.  相似文献   

6.
7.
BackgroundReliable and field-applicable diagnosis of schistosome infections in non-human animals is important for surveillance, control, and verification of interruption of human schistosomiasis transmission. This study aimed to summarize uses of available diagnostic techniques through a systematic review and meta-analysis.Methodology and principal findingsWe systematically searched the literature and reports comparing two or more diagnostic tests in non-human animals for schistosome infection. Out of 4,909 articles and reports screened, 19 met our inclusion criteria, four of which were considered in the meta-analysis. A total of 14 techniques (parasitologic, immunologic, and molecular) and nine types of non-human animals were involved in the studies. Notably, four studies compared parasitologic tests (miracidium hatching test (MHT), Kato-Katz (KK), the Danish Bilharziasis Laboratory technique (DBL), and formalin-ethyl acetate sedimentation-digestion (FEA-SD)) with quantitative polymerase chain reaction (qPCR), and sensitivity estimates (using qPCR as the reference) were extracted and included in the meta-analyses, showing significant heterogeneity across studies and animal hosts. The pooled estimate of sensitivity was 0.21 (95% confidence interval (CI): 0.03–0.48) with FEA-SD showing highest sensitivity (0.89, 95% CI: 0.65–1.00).Conclusions/significanceOur findings suggest that the parasitologic technique FEA-SD and the molecular technique qPCR are the most promising techniques for schistosome diagnosis in non-human animal hosts. Future studies are needed for validation and standardization of the techniques for real-world field applications.  相似文献   

8.

Background

Proteolysis of matrix components, in particular elastin, is a major contributing factor to the development of lung diseases such as emphysema and chronic obstructive pulmonary disease (COPD). MMP-12 (macrophage elastase) is a protease known to be involved in the progression of lung disease. The relatively low abundance of MMP-12 has precluded the development of quantitative assays that can accurately measure MMP-12 protein levels and activity across cohorts of healthy and diseased individuals.

Methods

Commercial antibodies were screened for performance in sandwich ELISA and capture FRET activity assay formats. Precision, accuracy, sensitivity, dilution linearity, and spike recovery were evaluated using sputum samples.

Results

Total protein and capture FRET activity assays were developed that were sensitive enough to detect MMP-12 in 37 of 38 donor sputum samples. A comparison of results between the two assays shows that a majority of sputum MMP-12 is in the active form. No differences were seen between normal, asthmatic, and COPD donors.

Conclusion

Sensitive and quantitative assays for both MMP-12 activity and total protein in human induced sputum have been developed. These assays can be used to evaluate MMP-12 as a biomarker for lung disease, and to monitor efficacy of potential therapeutic compounds.  相似文献   

9.

Aims

A new liquid-phase piezoelectric immunosensor (LP-PEIS), which can detect Schistosoma japonicum (Sj) circulating antigens (SjCAg) quantificationally, was developed.

Methods

The IgG antibodies were purified from the sera of rabbits which had been infected or immunized by Sj and were immobilized on the surface of piezoelectric quartz crystal in LP-PEIS by staphylococcal protein A (SPA). It was used to detect SjCAg in sera of rabbits which had been infected by Sj in order to acquire some optimum conditions for detecting SjCAg. Finally, the LP-PEIS with optimum conditions was used to detect SjCAg in sera of patients who had been infected by Sj, and was compared with sandwich ELISA.

Results

A lot of optimum conditions of LP-PEIS for detecting SjCAg had been acquired. In the detection of patients' sera with acute Schistosomiasis, LP-PEIS has higher positive rate (100%) and lower false positive rate (3.0%) than sandwich ELISA (92.8%, 6.0%). However, there were no significant difference between LP-PEIS and sandwich ELISA.

Conclusions

LP-PEIS can quantificationally detect SjCAg in patients' sera as well as sandwich ELISA.  相似文献   

10.
11.

Background

MicroRNAs (miRNAs) have been reported to be aberrantly expressed in patients with cancer. Many studies have shown that circulating miRNAs could play potential roles as diagnostic and prognostic biomarkers of cancers. The aim of this meta-analysis is to summarize the role of circulating miR-21 as a biomarker in patients with a variety of carcinomas.

Material and methods

Eligible studies were identified and assessed for quality through multiple search strategies. For diagnostic meta-analysis, the sensitivity, specificity, and other measures of miR-21 in the diagnosis of cancer were pooled using bivariate random-effects approach models. For prognostic meta-analysis, pooled hazard ratios (HRs) of circulating miR-21 for survival were calculated.

Results

A total of 36 studies dealing with various carcinomas were included for the systemic review. Among them, 23 studies were finally enrolled in the global meta-analysis (17 studies for diagnosis and 6 studies for prognosis). For diagnostic meta-analysis, the overall pooled results for sensitivity, specificity, positive likelihood ratio (LRP), negative likelihood ratios (LRN) and diagnostic odds ratio (DOR) were 75.7% (95% CI: 67.1%–82.6%), 79.3% (95% CI: 74.2%–83.5%), 3.65 (95% CI: 2.83–4.70), 0.31 (95% CI: 0.22–0.43), and 11.88 (95% CI: 6.99–20.19), respectively. For prognostic meta-analysis, the pooled HR of higher miR-21 expression in circulation was 2.37 (95% CI: 1.83–3.06, P < 0.001), which could significantly predict poorer survival in general carcinomas. Importantly, subgroup analysis suggested that higher expression of miR-21 correlated with worse overall survival (OS) significantly in carcinomas of digestion system (HR, 5.77 [95% CI: 2.65–12.52]).

Conclusions

Our findings suggest that circulating miR-21 may not suitable to be a diagnostic biomarker, but it has a prognostic value in patients with cancer.  相似文献   

12.
Isozyme patterns of six enzymes, glucose-6-phosphate dehydrogenase, glucosephosphate isomerase, hexokinase, malate dehydrogenase, 6-phosphate dehydrogenase and phosphoglucomutase were examined in electrophoresed homogenates of adult male worms of Schistosoma japonicum and S. mansoni. In general, enzyme patterns obtained from the parasite homogenates differed from that of host (mouse) blood and muscle, indicating that electrophoretic patterns from parasite extracts are most probably of parasite origin. Adult male and female S. mansoni worms yielded identical patterns. However, all six enzyme patterns showed distinct differences between S. japonicum and S. mansoni. These results suggest that S. japonicum is clearly distinguishable from S. mansoni at the molecular level.  相似文献   

13.
Antagonistic interactions between Schistosoma japonicum and Paragonimus ohirai were examined in the snail host, Oncomelania nosophora. When P. ohirai-infected snails were exposed to S. japonicum miracidia at intervals of 4 to 18 weeks post-first exposure, only a few snails (0-7%) were found to be superinfected with S. japonicum sporocysts. Sporocysts were fewer in number than those of single infected controls. Mature S. japonicum cercariae were not observed. Furthermore, when the snails were examined at intervals of 14 to 18 weeks post-second exposure, neither sporocysts nor cercariae of S. japonicum were found. On the other hand, when the snails were exposed to miracidia of S. japonicum and P. ohirai simultaneously, they were easily infected with both parasites. At 26 weeks after simultaneous exposure, however, the infection rate of S. japonicum was significantly lower than that of controls. In contrast, when S. japonicum-infected snails were exposed to P. ohirai miracidia, they were superinfected with P. ohirai, although the infection rate was somewhat lower than that of controls. These results indicate the existence of antagonism between S. japonicum and P. ohirai in O. nosophora. Furthermore, P. ohirai was dominant over S. japonicum in the antagonistic interactions in this snail host.  相似文献   

14.

Background:

Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test.

Methods:

We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters.

Results:

We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis.

Interpretation:

Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard.Undiagnosed sleep-disordered breathing places a substantial burden on patients, families, health care systems and society.1 Sleep fragmentation and recurrent hypoxemia cause daytime sleepiness and impaired concentration, which increase the risk of motor vehicle collisions and occupational accidents.27 In addition, sleep-disordered breathing is associated with hypertension, stroke, cardiovascular disease, obesity and type 2 diabetes,812 all of which involve greater use of health care resources.1317Obstructive sleep apnea is the most common type of sleep-disordered breathing. Narrowing of the upper airway during inspiration results in episodes of apnea (breathing cessation for at least 10 seconds), hypopnea (reduced airflow), oxygen desaturation and arousal from sleep due to respiratory effort.18 Clinical signs and symptoms include snoring, reports of nocturnal apnea, gasping or choking witnessed by a partner, daytime sleepiness, morning headaches and inability to concentrate. Patients with obesity or cardiovascular disease are at increased risk.19The severity of obstructive sleep apnea is usually graded using the apnea–hypopnea index (the mean number of apneas and hypopneas per hour of sleep) as follows: mild (5–14), moderate (15–29) and severe (≥ 30).18,20Other, less common types of sleep-disordered breathing include upper airway resistance syndrome, obesity hyperventilation syndrome, central sleep apnea, and nocturnal hypoventilation/hypoxemia secondary to cardiopulmonary or neuromuscular disease. It is not uncommon for patients to have more than 1 type of sleep-disordered breathing.Estimates of the prevalence of sleep-disordered breathing vary depending on the population (e.g., by sex, age and comorbidities).21 According to the Wisconsin Sleep Cohort Study, values in American adults (aged 30–60 yr) are 24% for men and 9% for women.1 A Canadian survey found a self-reported prevalence of sleep apnea of 3% among adults more than 18 years of age, and 5% among those more than 45 years of age.22 As the population ages and rates of obesity increase, the prevalence of sleep-disordered breathing is climbing.1,19,23,24 Given its clinical implications, accurate diagnosis and treatment of the condition are critical.Level 1 sleep testing, or polysomnography, requires an overnight stay in a sleep laboratory with a technician in attendance. It captures a minimum of 7 channels of data (but typically ≥ 16), including respiratory, cardiovascular and neurologic parameters, to produce a comprehensive picture of sleep architecture. Level 1 is considered the reference standard for diagnosing all types of sleep-disordered breathing and sleep disorders.19,2527 However, limited facilities and the growing demand for sleep studies have resulted in long wait times.28 Level 2 sleep testing uses level 1 equipment, but is performed without a technician in attendance.Level 3 testing uses portable monitors that allow sleep studies to be done at the patient’s home or elsewhere. This option was introduced as a more accessible and less expensive alternative to in-laboratory polysomnography. Level 3 devices record at least 3 channels of data (e.g., oximetry, airflow, respiratory effort). Unlike level 1, level 3 testing cannot measure the duration of sleep, the number of arousals or sleep stages, nor can it detect nonrespiratory sleep disorders.27,29 Level 4 devices are also portable, but they capture less data — usually only 1 or 2 channels.27,30We conducted a systematic review and meta-analysis to compare the diagnostic accuracy of the widely used level 3 portable monitors to in-laboratory polysomnography, and to determine the subpopulations of patients whose conditions might be most appropriately diagnosed with each test.  相似文献   

15.
A survey of helminths in domestic pigs was conducted in Khong District, Laos, to elucidate if these domestic animals could act as definitive hosts for Schistosoma mekongi and to obtain a general overview of their helminthological infection status. Fecal samples were collected from 98 pigs. Twelve pigs (12.2%) were found to excrete S. mekongi eggs. Infection was confirmed by detection of S. mekongi eggs in tissues of liver, rectum, and cecum of 2 pigs. A total of 75.8% of the pigs was infected with 1 or more helminth species. This study showed that pigs may act as a definitive host for S. mekongi.  相似文献   

16.
17.
18.

Background  

stroke is the main cause of disability in high-income countries, and ranks second as a cause of death worldwide. Patients with acute stroke are at risk for infections, but reported post-stroke infection rates vary considerably. We performed a systematic review and meta-analysis to estimate the pooled post-stroke infection rate and its effect on outcome.  相似文献   

19.
BackgroundBreast cancer (BC) is the most common cancer for women all over the world. Great interests have been paid to discover accurate and noninvasive methods for breast cancer diagnosis and prognosis. Although the diagnostic and prognostic value of microRNA-200 (miRNA- 200, miR-200) family has been revealed in many studies, the results were inconsistent. Thus, this meta-analysis aims to assess the overall value of miRNA-200 family in breast cancer diagnosis and prognosis.MethodRelevant studies were searched from the following databases: PubMed, PMC, EMBASE, and ScienceDirect using key words: ("miRNA-200 family" or "miR-141" or "miR-200a" or "miR-200b" or "miR-200c" or "miR-429") and (“HER2” or “Luminal A” or “Luminal B” or “TNBC”) and ("breast cancers" or "breast carcinoma" or "breast malignancy" or "breast tumor"). The sensitivity, specificity, AUC were then calculated to estimate the diagnostic accuracy of the miR-200 family. As for the prognostic value of the miR-200 family, the pooled hazard ratio (HR) was assessed. Heterogeneity among individual studies was also examined by subgroup analyses.ResultA total of 24 articles were included in the meta-analysis. The diagnostic value of miR-200s in BC was presented by the pooled sensitivity was 0.86 (95% CI: 0.83-0.88); the pooled specificity was 0.82 (95% CI: 0.72-0.89); the pooled AUC was 0.931 (95% CI: 0.919-0.942). Besides, expression of miR-200s in metastatic breast cancer has sensitivity, specificity and AUC of 0.70 (95%CI: 0.56-0.81), 0.72 (95%CI: 0.61-0.81), and 0.814 (95%CI: 0.741-0.903), respectively. The meta-analysis then revealed that high expression of miR-200 family corresponded to poor OS (HR: 1.63, 95% CI: 1.03-2.52), poor DFS (HR: 1.55, 95% CI: 0.95-2.56) in BC patients while downregulation of miRNA-200s corresponded to poor OS (HR= 0.84, 95%CI: 0.46-1.63) in TNBC patients and poor OS (HR=0.49; 95%CI: 0.27-0.88) in luminal BC patient.ConclusionThe MiR-200 family has high diagnostic accuracy and can be used as an important biomarker to prognosticate breast cancer.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号