首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A "repair-detection" procedure consisting of pour plating of food samples with Trypticase soy agar, followed by 1-h repair incubation at room temperature and subsequent overlay with violet red bile agar, was found to be an effective method for the detection of injuried and uninjuried coliforms from dairy products. This method was relatively less effective for the detection of coliforms in many semipreserved foods as compared with dairy products, but more effective than the most-probable-number method.  相似文献   

2.
The repair detection procedure of Speck et al. (Appl. Microbiol. 29:549-550, 1975) was adapted for the enumeration of coliforms, fecal coliforms, and enterococci in seafood and environmental samples. Samples were pour plated with Trypticase soy agar, followed by a 1- to 2-h incubation to effect repair; the plates were then overlaid with the selective medium and incubated. Violet red bile agar and an incubation temperature of 45 degrees C were used as the selective conditions for fecal coliforms, and KF streptococcal agar was used for the enumeration of enterococci. The method was more efficient than the standard most-probable-number method for fecal coliform enumeration and also allowed enumeration of the injured cells, which might have remained undetected when selective medium in the most-probable-number method was used. The repair detection method effectively recovered the injured portion of the population of enterococci capable of growing on KF streptococcal agar. The repair enumeration method was not suitable for coliforms in marine samples because associative marine bacteria mimicked coliforms in violet red bile agar plates incubated at 35 degrees C. The marine bacteria did not grow at 45 degrees C and therefore did not interfere with fecal coliform enumeration.  相似文献   

3.
The repair detection procedure of Speck et al. (Appl. Microbiol. 29:549-550, 1975) was adapted for the enumeration of coliforms, fecal coliforms, and enterococci in seafood and environmental samples. Samples were pour plated with Trypticase soy agar, followed by a 1- to 2-h incubation to effect repair; the plates were then overlaid with the selective medium and incubated. Violet red bile agar and an incubation temperature of 45 degrees C were used as the selective conditions for fecal coliforms, and KF streptococcal agar was used for the enumeration of enterococci. The method was more efficient than the standard most-probable-number method for fecal coliform enumeration and also allowed enumeration of the injured cells, which might have remained undetected when selective medium in the most-probable-number method was used. The repair detection method effectively recovered the injured portion of the population of enterococci capable of growing on KF streptococcal agar. The repair enumeration method was not suitable for coliforms in marine samples because associative marine bacteria mimicked coliforms in violet red bile agar plates incubated at 35 degrees C. The marine bacteria did not grow at 45 degrees C and therefore did not interfere with fecal coliform enumeration.  相似文献   

4.
mT7 medium performed no better than m-Endo medium in enumerating cells of Escherichia coli and Citrobacter freundii exposed to ozone. Also, there was no difference in the plate count of heterotrophic bacteria in ozonated raw water determined on modified Henrici agar or R2A agar. Statistically significant differences were seen between bacteria and the type of water in which they were suspended during ozonation.  相似文献   

5.
Quantitative procedure for enumeration of bifidobacteria.   总被引:4,自引:3,他引:4       下载免费PDF全文
A membrane filter technique has been developed for the enumeration of bifidobacteria in natural aquatic environments. The technique is quantitative, selective, and differential. The medium (YN-6) contains: yeast extract, 2.0 g; agar, 1.5 g; polypeptone peptone, 1.0 g; vitamin-free Casamino Acids, 0.8 g; sodium chloride, 0.32 g; and L-cysteine hydrochloride, 0.003 g; in 100 ml of deionized water. The medium is adjusted to pH 7.0 before autoclaving. Nalidixic acid (80 micrograms/ml), neomycin sulfate (2.5 micrograms/ml), and bromcresol green (300 micrograms/ml) are included as selective and differential agents. After incubation for 48 h at 37 degrees C in an anaerobic environment, Gram-stained smears from green, glistening, smooth entire colonies are examined microscopically for typical bifidobacterial morphology. No significant difference in recoveries was observed when YN-6 was compared with reinforced clostridial agar, using bifidobacteria freshly isolated from feces and raw sewage. Using this technique with aquatic and fecal samples, less than 9% false-positive and 8% false-negative isolates were observed. These results indicated that the medium was able to satisfactorily recover organisms from a variety of situations.  相似文献   

6.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

7.
Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms in an inoculum and the time required for an electrical impedance ratio signal to be detected. Pure culture inocula consisting of 100 fecal coliforms in log phase or stationary phase were detected in 6.5 and 7.7 h, respectively. Standard curves of log10 fecal coliforms in wastewater inocula versus detection time, based on samples collected at a sewage treatment plant over a 4-month period, were found to vary from one another with time. Nevertheless, detection times were rapid and ranged from 5.8 to 7.9 h for 200 fecal coliforms to 8.7 to 11.4 h for 1 fecal coliform. Variations in detection times for a given number of fecal coliforms were also found among sewage treatment plants. A strategy is proposed which takes these variations into account and allows for rapid, automated enumeration of fecal coliforms in wastewater by the electrical impedance ratio technique.  相似文献   

8.
Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms in an inoculum and the time required for an electrical impedance ratio signal to be detected. Pure culture inocula consisting of 100 fecal coliforms in log phase or stationary phase were detected in 6.5 and 7.7 h, respectively. Standard curves of log10 fecal coliforms in wastewater inocula versus detection time, based on samples collected at a sewage treatment plant over a 4-month period, were found to vary from one another with time. Nevertheless, detection times were rapid and ranged from 5.8 to 7.9 h for 200 fecal coliforms to 8.7 to 11.4 h for 1 fecal coliform. Variations in detection times for a given number of fecal coliforms were also found among sewage treatment plants. A strategy is proposed which takes these variations into account and allows for rapid, automated enumeration of fecal coliforms in wastewater by the electrical impedance ratio technique.  相似文献   

9.
A membrane filtration procedure has been developed for the enumeration of Vibrio parahaemolyticus in marine waters. Background microbial growth on the primary medium was decreased through the use of sodium cholate and copper sulfate, high pH, 3% NaCl, and an elevated incubation temperature. A series of in situ tests was employed to obviate the picking of colonies for identification; thereby, the enumeration of V. parahaemolyticus was accomplished within 30 h. Confirmation of typical colonies approached 95%. Relative to immediate plating on brain heart infusion agar spread plates, the recovery of V. parahaemolyticus cells suspended in phosphate-buffered saline or in seawater held for 24 h at 4 to 6 degrees C was about 90%. Assay variability did not exceed that expected by chance. Recoveries of V. parahaemolyticus from coastal and estuarine surface waters exceeded those obtainable by other methods examined.  相似文献   

10.
mT7 medium performed no better than m-Endo medium in enumerating cells of Escherichia coli and Citrobacter freundii exposed to ozone. Also, there was no difference in the plate count of heterotrophic bacteria in ozonated raw water determined on modified Henrici agar or R2A agar. Statistically significant differences were seen between bacteria and the type of water in which they were suspended during ozonation.  相似文献   

11.
In a comparison of five selected methods for the enumeration of fecal coliforms and Escherichia coli in naturally contaminated and sewage-seeded mussels (Choromytilus spp.) and oysters (Ostrea spp.), a spread-plate procedure with mFC agar without rosolic acid and preincubation proved the method of choice for routine quality assessment.  相似文献   

12.
Use of enzymatic methods for rapid enumeration of coliforms in freshwaters   总被引:2,自引:0,他引:2  
Rapid enumeration methods based on the enzymatic hydrolysis of 4-methylumbelliferyl-beta-D-galactoside and 4-methylumbelliferyl-beta-D-glucuronide were optimized for freshwaters. The enzymes beta-D-galactosidase (GALase) and beta-D-glucuronidase (GLUase) were shown to be already induced in freshwaters when tested, respectively, with the inducers isopropyl-beta-D-thiogalactopyranoside and methyl-beta-D-glucuronide. Both enzymatic activities were compared, respectively, with plate counts of total and faecal coliforms in freshwaters. Enzymatic methods and reference plate counts were significantly correlated in log-log plots. Moreover, the GLUase method allowed the detection of viable (presenting a detectable GLUase activity) but nonculturable Escherichia coli.  相似文献   

13.
Two media were developed that allowed both a total coliform count and an Escherichia coli count to be determined on the same medium after 24 h of incubation at 35 degrees C. The new media were tested along with two standard media on 10 surface water and 7 sewage samples. The experimental media yielded equivalent or higher counts relative to the standard media and recovered more specifically the desired indicator groups as determined by colony identification.  相似文献   

14.
The Autoanalysis Colilert (AC) test was compared with the membrane filter (MF), 10-tube multiple-tube fermentation (MTF) technique, and the presence-absence test as described in Standard Methods for the Examination of Water and Wastewater for the detection and enumeration of total coliforms in water. The methods were evaluated with 31 samples from seven different sources. Each sample was analyzed by each of the techniques, using replicate 100-ml sample volumes. A total of 582 confirmed tubes were positive by the MTF test, and 533 tubes were positive by the AC test. Statistical analysis of the most-probable-number comparability data showed a statistically significant difference in the number of positive tubes, with the MTF test resulting in more positive tubes. There were no statistically significant differences in precision between the two methods. All the methods were comparable in detection of total coliforms. Levels of heterotrophic bacteria generally encountered in drinking water did not interfere with detection or enumeration of coliforms by the AC test.  相似文献   

15.
Three holding media, including the vitamin-free Casitone holding medium (m-VFC) recommended by Standard Methods for the Examination of Water and Wastewater for use with the delayed-incubation membrane filter procedure, were compared for their ability to maintain viability of fecal coliforms. Each medium was tested according to the procedure described in the above reference with 60 to 80 pure cultures of fecal coliforms and a variety of natural water samples containing fecal coliforms. Fecal coliform recovery with m-ST holding medium (containing ethanol, sulfanilamide, and Tris [pH 8.6] was significantly greater than recovery with m-VFC (containing vitamin-free casein hydrolysate, sodium benzoate, sulfanilamide, and ethanol). Recovery with m-VFC, was, in turn, significantly greater than with NSB medium (containing nutrient broth, boric acid, and NaCl as major ingredients). Fecal coliform counts obtained with m-ST by the delayed-incubation membrane filter procedure were higher than counts obtained by the standard immediate incubation. This result suggested that some of the sublethally injured fecal coliforms in natural water samples may have recovered during the incubation period. We propose that m-ST be used in place of m-VFC for the delayed-incubation membrane filter procedure.  相似文献   

16.
A procedure was developed for accelerating to 29 h the enumeration and identification of both healthy and stressed cells of Staphylococcus aureus in foods. Baird-Parker agar medium was incubated for 24 h; S. aureus was identified within 5 additional h by using a simplified thermonuclease test.  相似文献   

17.
Two media were developed that allowed both a total coliform count and an Escherichia coli count to be determined on the same medium after 24 h of incubation at 35 degrees C. The new media were tested along with two standard media on 10 surface water and 7 sewage samples. The experimental media yielded equivalent or higher counts relative to the standard media and recovered more specifically the desired indicator groups as determined by colony identification.  相似文献   

18.
The number of coliforms in processed food was enumerated rapidly by the use of ion mobility spectrometry. This method measured the time to observe o -nitrophenol liberated from the substrate o -nitrophenylgalactoside and was inversely proportional to the logarithm of the initial coliform count. The presence or absence of coliforms was determined within 12 h. This assay was unsuitable for non-processed foods due to the presence of an endogenous β-galactosidase enzyme.  相似文献   

19.
Recovery of total coliforms and Escherichia coli on a new membrane filtration (MF) medium was evaluated with 25 water samples from seven states. Testing of the new medium, m-ColiBlue24 broth, was conducted according to a U.S. Environmental Protection Agency protocol. For comparison, this same protocol was used to measure recovery of total coliforms and E. coli with two standard MF media, m-Endo broth and mTEC broth. E. coli recovery on the new medium was also compared to recovery on nutrient agar supplemented with 4-methylumbelliferyl-beta-D-glucuronide. Comparison of specificity, sensitivity, false positive error, undetected target error, and overall agreement indicated E. coli recovery on m-ColiBlue24 was superior to recovery on mTEC for all five parameters. Recovery of total coliforms on the new medium was comparable to recovery on m-Endo.  相似文献   

20.
Violet red bile agar and Coli-Count Sampler (Millipore Corp.) procedures were shown to be acceptable alternatives to the standard most-probable-number method for monitoring relative coliform levels in oysters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号