首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Simultaneous nitrification and denitrification (SND) was realized by means of a novel air-lift internal loop biofilm reactor, in which aeration was set in middle of the reactor. During operation, the aeration was adjusted to get appropriate dissolve oxygen (DO) in bulk solution and let aerobic and anoxic zone coexist in one reactor. When aeration was at 0.6 and 0.2 L/min, corresponding to DO of 5.8 and 2.5 mg/L in bulk solution, ammonia nitrogen removal percentage reached about 80 and 90 %, but total nitrogen removal percentage was lower than 25 %. While the aeration was reduced to 0.1 L/min, aerobic and anoxic zones existed simultaneously in one reactor to get 75 % of ammonia nitrogen and 50 % of total nitrogen removal percentage. Biofilms were, respectively, taken from aerobic and anoxic zone to verify their function of nitrification and denitrification in two flasks, in which ammonia nitrogen was transferred into nitrate completely by aerobic biofilm, and nitrate was removed more than 80 % by anoxic biofilm. Microelectrode was used to measure the DO distribution inside biofilms in anoxic zone corresponding to different aerations. When aeration was at 0.6 and 0.2 L/min, DO inside biofilm was more than 1.5 mg/L, but the DO inside biofilm decreased to anoxic status with depth of biofilm increasing corresponding to aeration of 0.1 L/min. The experimental results indicated that SND could be realized because of simultaneous existence of aerobic and anoxic biofilms in one reactor.  相似文献   

2.
This study aimed to find optimal operation conditions for nitrogen removal from high strength slaughterhouse wastewater at 11 °C using the intermittently aerated sequencing batch reactors (IASBRs) so as to provide an engineering control strategy for the IASBR technology. Two operational parameters were examined: (1) loading rates and (2) aeration rates. Both the two parameters affected variation of DO concentrations in the IASBR operation cycles. It was found that to achieve efficient nitrogen removal via partial nitrification–denitrification (PND), “DO elbow” point must appear at the end of the last aeration period. There was a correlation between the ammonium oxidizing bacteria (AOB)/nitrite oxidizing bacteria (NOB) ratio and the average DO concentrations in the last aeration periods; when the average DO concentrations in the last aeration periods were lower than 4.86 mg/L, AOB became the dominant nitrifier population, which benefited nitrogen removal via PND. Both the nitrogen loading rate and the aeration rate influenced the population sizes of AOB and NOB. To accomplish efficient nitrogen removal via PND, the optimum aeration rate (A, L air/min) applied can be predicted according to the average organic loading rates based on mathematical equations developed in this study. The research shows that the amount of N2O generation in the aeration period was reduced with increasing the aeration rate; however, the highest N2O generation in the non-aeration period was observed at the optimum aeration rates.  相似文献   

3.
Macrophyte combined with artificial aeration is a promising in situ remediation approach for urban rivers polluted with nutrients and organic matter. However, seasonal variations and aeration effects on phytoremediation performance and root-adhered microbial communities are still unclear. In this study, Pontederia cordata was used to treat polluted urban river water under various aeration intensities. Results showed that the highest removal efficiencies of chemical oxygen demand (CODCr) and total nitrogen (TN) were attained under aeration of 30 L min?1 in spring and summer and 15 L min?1 in autumn, while total phosphorus (TP) removal reached maximum with aeration of 15 L min?1 in all seasons. Moderate aeration was beneficial for increasing the diversity of root-adhered bacteria communities, and the shift of bacterial community structure was more pronounced in spring and autumn with varying aeration intensity. The dual effect, i.e. turbulence and dissolved oxygen (DO), of aeration on the removal of CODCr and TN prevailed over the individual effect of DO, while DO was the most influential factor for TP removal and the root-adhered bacterial community diversity. P. cordata combined with 15 L min?1 aeration was deemed to be the best condition tested in this study.  相似文献   

4.
A failure in the aeration system of Litopenaeus vannamei rearing with biofloc technology can decrease the oxygen concentrations rapidly and also increase the carbon dioxide (CO2) concentrations at the same rate. We report here an evaluation of the effect of CO2 on the oxygen consumption of L. vannamei. We used a continuous-flow respirometer with water recirculation equipped with a digital fiber-optic oximeter. Eight juveniles of L. vannamei (12.1 ± 1. 4 g) were used in each treatment with one per respiratory chamber (0.6 L). The shrimp were exposed to six concentrations of CO2 (5, 30, 60, 95, 150, and 300 mgCO2/L) with an acute exposure time of six hours. Upon treatment with 5–30 mgCO2/L, we observed a consumption of oxygen of 0.233 ± 0.129 and 0.33 ± 0.072 mgO2/g/h, respectively. Upon treatment with 60 mgCO2/L, an increase was observed in the oxygen consumption (0.521 ± 0.098 mgO2/g/h). Upon treatment with 95, 150, and 300 mgCO2/L however, the shrimp decreased their oxygen consumption and lost their equilibrium. The CO2 should therefore be maintained at a maximum of 5 mgCO2/L during shrimp rearing.  相似文献   

5.
This work focused on determining the effect of dissolved oxygen concentration (DO) on growth and metabolism of BHK-21 cell line (host cell for recombinant proteins manufacturing and viral vaccines) cultured in two stirred tank bioreactors with different aeration-homogenization systems, as well as pH control mode. BHK-21 cell line adapted to single-cell suspension was cultured in Celligen without aeration cage (rotating gas-sparger) and Bioflo 110, at 10, 30 and 50 % air saturation (impeller for gas dispersion from sparger-ring). The pH was controlled at 7.2 as far as it was possible with gas mixtures. In other runs, at 30 and 50 % (DO) in Bioflo 110, the cells grew at pH controlled with CO2 and NaHCO3 solution. Glucose, lactate, glutamine, and ammonium were quantified by enzymatic methods. Cell concentration, size and specific oxygen consumption were also determined. When NaHCO3 solution was not used, the optimal DOs were 10 and 50 % air saturation for Celligen and Bioflo 110, respectively. In this condition maximum cell concentrations were higher than 4 × 106 cell/mL. An increase in maximum cell concentration of 36 % was observed in batch carried out at 30 % air saturation in a classical stirred tank bioreactor (Bioflo 110) with base solution addition. The optimal parameters defined in this work allow for bioprocess developing of viral vaccines, transient protein expression and viral vector for gene therapy based on BHK-21 cell line in two stirred tank bioreactors with different agitation–aeration systems.  相似文献   

6.
Enhanced biological nitrogen removal processes are necessarily required to cope with more stringent wastewater discharging regulations, especially for wastewater with low level of organic carbon to nitrogen ratios. The intermittent aeration activated sludge process has been received comprehensive attention over the past decades, due to its excellent performance in nitrogen removal and remarkable reduction of energy consumption. Recent advances for this technology was reviewed from aspects of characteristics of system, factors affecting nitrogen removal, nitrous oxide (N2O) emission and its control, and application of the technology and its operation control. Finally, future development was proposed. In the intermittent aeration activated sludge process, aeration duration should be controlled for adequate nitrification and non-aeration duration should be adequate for complete denitrification, and these would benefit both nitrogen removal and N2O mitigation. The step feed strategy could be applied to enhance the better utilization of influent organic carbon for nitrogen removal. Dissolved oxygen (DO) and aerobic duration both affected nitrogen removal in particular that via nitrite in the intermittent aeration process. Nitrite should be removed efficiently to avoid a high N2O emission under both anoxic and aerobic conditions. Intermittent aeration activated sludge process has been applied in the treatment of various wastewaters, such as municipal wastewater, swine wastewater, anaerobic effluents and landfill leachate. For practical application, DO, pH and oxidation–reduction potential could be used as indices for controlling nitrogen removal and N2O mitigation. Microbial ecology in the intermittent aeration activated sludge process should be specifically focused in future studies.  相似文献   

7.
《Process Biochemistry》2007,42(3):320-328
A shortcut biological nitrogen removal (SBNR) process converts ammonium directly through nitrite to nitrogen gas, thus requiring less aeration and carbon. We evaluated a hybrid SBNR (HSBNR) reactor containing an anoxic tank followed by an aerobic tank and a settling tank. The aerobic tank was filled with polyvinyl alcohol sponge media (20%, v/v) to attach and retain ammonium oxidizers. Two configurations of the HSBNR reactor were tested for treating a wastewater with high strength ammonium and organic electron donor. The HSNBR reactors accumulated nitrite stably for 1.5 years and maintained a high free ammonia (FA) concentration (20–25 mg/L) and a low dissolved oxygen (DO) concentration (<1 mg/L) in the aerobic tank. Apparently, the biofilm carriers increased the solids retention time (SRT) for ammonium oxidizers, while high FA and low DO selected against nitrite oxidizers and promoted direct denitrification of nitrite in the aerobic tank. The significant amount of chemical oxygen demand (COD) was removed by shortcut denitrification of nitrite in the anoxic tank.  相似文献   

8.
Leachate treatment is a challenging issue due to its high pollutant loads. There are several studies on feasible treatment methods of leachate. In the scope of this study, high organic content of young leachate was eliminated using an upflow anaerobic sludge blanket (UASB) and a membrane bioreactor (MBR) in sequence and effluent of the system was given to single reactor for high activity ammonia removal over nitrite (SHARON) and anaerobic ammonia oxidation (Anammox) reactors to remove nitrogen content. All reactors were set up at lab scale in order to evaluate the usage of these processes in sequencing order for leachate treatment. COD and TKN removal efficiencies were over 90 % in the combined processes which were operated during the study. The biodegradable portion of organic matter was removed with an efficiency of 99 %. BOD5 concentration decreased to 50 mg/L by UASB and MBR in sequence even the influent BOD5 concentration was over 8,000 mg/L. Although high nitrogen concentrations were observed in raw leachate, successful removal of nitrogen was accomplished by consecutive operations of SHARON and Anammox reactors. The results of this study demonstrated that with an efficient pretreatment of leachate, the combination of SHARON–Anammox processes is an effective method for the treatment of high nitrogen content in leachate.  相似文献   

9.
Li YZ  He YL  Ohandja DG  Ji J  Li JF  Zhou T 《Bioresource technology》2008,99(13):5867-5872
This study assessed the performance of different single-stage continuous aerated submerged membrane bioreactors (MBR) for nitrogen removal. Almost complete nitrification was achieved in each MBR irrespective of operating mode and biomass system. Denitrification was found to be the rate-limiting step for total nitrogen (T-N) removal. The MBR with internal-loop airlift reactor (ALR) configuration performed better as regards T-N removal compared with continuous stirred-tank reactor (CSTR). It was demonstrated that simultaneous nitrification and denitrification (SND) is the mechanism leading to nitrogen removal and the contribution of microenvironment on SND is more remarkable for the MBRs with hybrid biomass. Macroenvironment analyses showed that gradient distribution of dissolved oxygen (DO) level in airlift MBRs imposed a significant effect on SND. Higher mixed liquor suspended solid (MLSS) concentration led to the improvement in T-N removal by enhancing anoxic microenvironment. Apparent nitrite accumulation coupled with higher nitrogen reduction was accomplished at MLSS concentration exceeded 12.6 g/L.  相似文献   

10.
An attempt to restore the settling ability of denatured bulking sludge was under-taken by changing the microflora in waste treatment tanks. A cell suspension of mixed cultures of ten strains of bacteria, which were isolated from normal activated sludge from night soil plants, and a type culture Zoogloea ramigera IAM1236 was seeded into a laboratory-scale aeration tank containing bulking sludge collected from municipal night soil or a food processing (bean curd production) waste treatment plant. The tank was fed with synthetic wastewater or industrial waste and aerated for 22 days. After 5 days, the microflora in the sludge changed remarkably with the seeding of the bacterial culture; filamentous organisms disappeared and active protozoa (Vorticella sp., Epistylis sp., and Lecane sp.) appeared. The sludge became compact and settled rapidly. The SV30 of the sludge temporarily increased, but in the end decreased from 97 to 20%. The CODcr value decreased from 300 to 20 ppm. In the tank without seeding, the sludge contained almost filamentous organisms only which floated and finally decomposed. The effects were confirmed by applied tests in 700-ton scale and 100-ton scale aeration tanks of municipal night soil and a food processing waste treatment plant, respectively.  相似文献   

11.
Seven different aeration modes, in which oxygen supply was changed by adjusting the number of aerators, were designed and applied in a full-scale municipal wastewater treatment plant with Orbal oxidation ditch to investigate the influence of dissolved oxygen (DO) on nitrogen removal performance. The full-scale experiment results of 574 days showed that nitrogen removal efficiency depended on the degree of nitrification and denitrification in the outer channel, which was the largest contributor for TN removal in the Orbal oxidation ditch. Appropriate aeration control in the outer channel was essential to balance nitrification and denitrification in the Orbal oxidation ditch. When DO was as low as about 0.2 mg/L in the outer channel, the highest TN removal efficiency of 75% was obtained. Microbial analysis confirmed that aerobic and anaerobic bacteria coexisted in the outer channel. The greater species diversity and more intensive activities of these bacteria in aeration Mode V may be responsible for the higher TN removal efficiency compared with Mode III. These results suggest that different aerated conditions in the Orbal oxidation ditch might have a significant effect on microbial community characteristics and nitrogen removal efficiencies.  相似文献   

12.
Summary In the activated sludge treatment plant of Onoda City, bulking has often been caused by filamentous bacteria, types 021 N and I-2. Bulking disappeared when Trochilioides recta increased in the mixed liquor of the aeration tank. T.-recta was observed to ingest types 021 N or I-2. It may therefore be anticipated that this type of bulking could be controlled by T. recta.  相似文献   

13.
Although biological nitrogen removal via nitrite is recognized as one of the cost-effective and sustainable biological nitrogen removal processes, nitrite accumulation has proven difficult to achieve in continuous processes treating low-strength nitrogenous wastewater. Partial nitrification to nitrite was achieved and maintained in a lab-scale completely stirred tank reactor (CSTR) treating real domestic wastewater. During the start-up period, sludge with ammonia-oxidizing bacteria (AOB) but no nitrite-oxidizing bacteria (NOB) was obtained by batch operation with aeration time control. The nitrifying sludge with the dominance of AOB was then directly switched into continuous operation. It was demonstrated that partial nitrification to nitrite in the continuous system could be repeatedly and reliably achieved using this start-up strategy. The ratio of dissolved oxygen to ammonium loading rate (DO/ALR) was critical to maintain high ammonium removal efficiency and nitrite accumulation ratio. Over 85% of nitrite accumulation ratio and more than 95% of ammonium removal efficiency were achieved at DO/ALR ratios in an optimal range of 4.0–6.0 mg O2/g N d, even under the disturbances of ammonium loading rate. Microbial population shift was investigated, and fluorescence in situ hybridization analysis indicated that AOB were the dominant nitrifying bacteria over NOB when stable partial nitrification was established.  相似文献   

14.
With the rapid development of scaled anaerobic digestion of pig manure, the generation of liquid anaerobic digestate exceeds the farmland loading capacity, causing serious environmental pollution. Three laboratory‐scale horizontal subsurface flow constructed wetlands (CWs; planted + aeration, planted, and unplanted) were set up to investigate the feasibility of liquid digestate treatment in wetlands. Treatment capacity in different wetlands was evaluated under different influent concentrations (chemical oxygen demand [COD], 5 days biochemical oxygen demand [BOD5], and nitrogen forms). The effect of aeration and effluent recirculation on organic matter and total nitrogen removal was investigated. Results showed that integrating intermittent aeration in CWs significantly improved the oxygen condition (p < 0.01) in the wetland bed and promoted BOD5 removal to 90% in aerated CWs as compared with <15% in the unaerated CWs. Meanwhile, COD removal between these three wetlands did not show any difference and varied from 52 to 72% under influent concentration of 200–820 mg/L because of the high content of hard‐degradable organic matter in the liquid digestate. Intermittent aeration resulted in high ammonium removal (>98%) although the influent loading varied from 65 to 350 mg/L. However, intermittent aeration caused nitrate accumulation of 300 mg/L and limited total nitrogen (TN) removal of 33%. To intensify the TN removal, we verified effluent recirculation to increase the removal efficiency of TN to 78%. These results not only show the potential application of CWs for treatment of high‐strength liquid anaerobic digested slurry, but also indicate the significance of intermittent aeration on the enhanced removal of organic matter and ammonium.  相似文献   

15.
The performance of an intermittently aerated sequencing batch reactor (IASBR) technology was investigated in achieving partial nitrification, organic matter removal and nitrogen removal from separated digestate liquid after anaerobic digestion of pig manure. The wastewater had chemical oxygen demand (COD) concentrations of 11,540 ± 860 mg/L, 5-day biochemical oxygen demand (BOD5) concentrations of 2,900 ± 200 mg/L and total nitrogen (TN) concentrations of 4,041 ± 59 mg/L, with low COD:N ratios (2.9) and BOD5:COD ratios (0.25). Synthetic wastewater, simulating the separated digestate liquid with similar COD and nitrogen concentrations but BOD5 of 11,500 ± 100 mg/L, was also treated using the IASBR technology. At a mean organic loading rate of 1.15 kg COD/(m3 d) and a nitrogen loading rate of 0.38 kg N/(m3 d), the COD removal efficiency was 89.8% in the IASBR (IASBR-1) treating digestate liquid and 99% in the IASBR (IASBR-2) treating synthetic wastewater. The IASBR-1 effluent COD was mainly due to inert organic matter and can be further reduced to less than 40 mg/L through coagulation. The partial nitrification efficiency of 71–79% was achieved in the two IASBRs and one cause for the stable long-term partial nitrification was the intermittent aeration strategy. Nitrogen removal efficiencies were 76.5 and 97% in IASBR-1 and IASBR-2, respectively. The high nitrogen removal efficiencies show that the IASBR technology is a promising technology for nitrogen removal from low COD:N ratio wastewaters. The nitrogen balance analysis shows that 59.4 and 74.3% of nitrogen removed was via heterotrophic denitrification in the non-aeration periods in IASBR-1 and IASBR-2, respectively.  相似文献   

16.
The biological nitrification-denitrification process is used extensively for removal of ammonia nitrogen from wastewaters. Saves in aeration, organic matter (for denitrification) and surplus sludge are achievable if nitrite accumulation is possible in the nitrification step. In this paper, operational parameters were studied for each process for maximum nitrite accumulation in the nitrification step and nitrite adaptation in the denitrification step. Nitrite accumulation during nitrification can be controlled by the dissolved oxygen (DO) concentration, presenting a maximum of 65% at around 0.7 mg DO/L. Denitrification can be adapted to nitrite and the process is stable if nitrite in the reactor is keep low. The performance of a continuous stirred tank reactor (CSTR) and an up flow sludge blanket reactor (USB) were compared. Once the operational parameters were established, a CSTR for nitrification and an USB reactor for denitrification were operated in series for 25 days. The process was stable and a steady state was maintained for 20 days, and 93.5% of overall nitrogen removal was achieved in the nitrification-denitrification via the nitrite process.  相似文献   

17.
The feasibility of nitrite accumulation in a pilot-scale A/O (anoxic/oxic) nitrogen removal plant treating domestic wastewater was investigated at various dissolved oxygen (DO) concentrations and pH levels. The results showed that the pH was not a useful operational parameter to realize nitrite accumulation. Significant nitrite accumulation was observed at the low DO concentration range of 0.3–0.8 mg/l and the maximum nitrite accumulation ratio of about 90% occurred at a DO concentration of 0.6 mg/l. This suggests a reduction of 22% in the oxygen consumption, and therefore a considerable saving in aeration. However, the nitrite accumulation was destroyed at the high DO concentration and the resumption was very slow. In addition, the average ammonia removal efficiency reached as high as 93% at the low DO level. Moreover, experimental results indicated that nitrogen could be removed by simultaneous nitrification and denitrification (SND) via nitrite in the aerobic zones at the low DO concentration, with the efficiency of 6–12%.  相似文献   

18.
The process of nitrification–denitrification via nitrite for nitrogen removal under real-time control mode was tested in two laboratory-scale sequencing batch reactors (SBRs) with flocculent activated sludge (R1) and aerobic granular sludge (R2) to compare operational performance and real-time control strategies. The results showed that the average ammonia nitrogen, total inorganic nitrogen (TIN), and chemical oxygen demand (COD) removal during aeration phase were 97.6%, 57.0%, and 90.1% in R2 compared with 98.6%, 48.7%, and 88.1% in R1. The TIN removed in both SBRs was partially due to the presence of simultaneous nitrification–denitrification via nitrite, especially in R2. The specific nitrification and denitrification rates in R2 were 0.0416 mgNH4+–N/gSS-min and 0.1889 mgNOX–N/gSS-min, which were 1.48 times and 1.35 times that of R1. The higher rates for COD removal, nitrification, and denitrification were achieved in R2 than R1 with similar influent quality. Dissolved oxygen (DO), pH, and oxidization reduction potential, corresponding to nutrient variations, were used as diagnostic parameters to control the organic carbon degradation and nitrification–denitrification via nitrite processes in both SBRs. The online control strategy of granular SBR was similar to that of the SBR with flocculent activated sludge. However, a unique U-type pattern on the DO curve in granular SBR was different from SBR with flocculent activated sludge in aerobic phase.  相似文献   

19.
Process analytical technology (PAT) is an initiative from the US FDA combining analytical and statistical tools to improve manufacturing operations and ensure regulatory compliance. This work describes the use of a continuous monitoring system for a protein refolding reaction to provide consistency in product quality and process performance across batches. A small‐scale bioreactor (3 L) is used to understand the impact of aeration for refolding recombinant human vascular endothelial growth factor (rhVEGF) in a reducing environment. A reverse‐phase HPLC assay is used to assess product quality. The goal in understanding the oxygen needs of the reaction and its impact to quality, is to make a product that is efficiently refolded to its native and active form with minimum oxidative degradation from batch to batch. Because this refolding process is heavily dependent on oxygen, the % dissolved oxygen (DO) profile is explored as a PAT tool to regulate process performance at commercial manufacturing scale. A dynamic gassing out approach using constant mass transfer (kLa) is used for scale‐up of the aeration parameters to manufacturing scale tanks (2,000 L, 15,000 L). The resulting DO profiles of the refolding reaction show similar trends across scales and these are analyzed using rpHPLC. The desired product quality attributes are then achieved through alternating air and nitrogen sparging triggered by changes in the monitored DO profile. This approach mitigates the impact of differences in equipment or feedstock components between runs, and is directly inline with the key goal of PAT to “actively manage process variability using a knowledge‐based approach.” Biotechnol. Bioeng. 2009; 104: 340–351 © 2009 Wiley Periodicals, Inc.  相似文献   

20.
The performance of continuous flow intermittent decant type sequencing batch (CFID) reactor treating the effluent of an UASB reactor treating domestic wastewater and operated at 8 h hydraulic retention time (HRT) was investigated. The CFID was operated at three different HRTs (22, 8 and 6 h) and three different dissolved oxygen (DO) patterns (<0.5, 2.5–3.5 and 3.5–4.5 mg/L). The highest effluent quality was observed at the 8 h HRT and 2.5–3.5 mg/L DO concentration. At this operational condition, the average BOD, TSS, ammonia nitrogen and fecal coliform removal efficiencies were 83, 90, 74 and 99 %, respectively. The CFID is a promising post-treatment option for existing UASB systems, with a final effluent quality that comply with receiving water and effluent reuse criteria.  相似文献   