首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Xia Q  Chen X  Liu JH 《Biophysical chemistry》2008,136(2-3):101-107
A novel DNA hybridization sensor based on nanoparticle CdS modified glass carbon electrode (GCE) was constructed and characterized coupled with Cyclic Voltammogram (CV) and Differential Pulse Voltammogram (DPV) techniques. The mercapto group-linked probe DNA was covalently immobilized onto the CdS layer and exposed to oligonucleotide (ODN) target for hybridization. The structure of DNA sensor was characterized by X-ray diffraction (XRD), field-emission microscopy (FESEM) and X-ray photoelectron spectra (XPS). Sensitive electrical readout achieved by CV and DPV techniques shown that when the target DNA hybridized with probe CdS-ODN conjugates and the double helix formed on the modified electrode, a significant increased response was observed comparing with the bare electrodes. The selectivity of the sensor was tested using a series of matched and certain-point mismatched sequences with concentration grads ranging from 10(-6) microM to 10(1) microM. The signal was in good linear with the minus logarithm of target oligonucleotide concentration with detection limit <1 pM and the optimized target DNA concentration was 10(-6) microM for the signal amplification. Due to great surface properties, the additional negative charges and space resistance of as-prepared CdS nanoparticles, the sensor was able to robustly discriminate the DNA hybridization responses with good sensitivity and stability.  相似文献   

2.
Laccase purified from Ganoderma sp. was immobilized covalently onto electrochemically deposited silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (cMWCNT)/polyaniline (PANI) layer on the surface of gold (Au) electrode. A polyphenol biosensor was fabricated using this enzyme electrode (laccase/AgNPs/cMWCNT/PANI/Au electrode) as the working electrode, Ag/AgCl as the reference electrode, and platinum (Pt) wire as the auxiliary electrode connected through a potentiostat. The biosensor showed optimal response at pH 5.5 (0.1 M acetate buffer) and 35 °C when operated at a scan rate of 50 mV s−1. Linear range, response time, and detection limit were 0.1–500 μM, 6 s, and 0.1 μM, respectively. The sensor was employed for the determination of total phenolic content in tea, alcoholic beverages, and pharmaceutical formulations. The enzyme electrode was used 200 times over a period of 4 months when stored at 4 °C. The biosensor has an advantage over earlier enzyme sensors in that it has no leakage of enzyme during reuse and is unaffected by the external environment due to the protective PANI microenvironment.  相似文献   

3.
The aim of the present work is to design an electrode for biosensors by covalent immobilization of the redox enzyme. In the covalently modified electrode, the biocatalyst is located close to the electrode surface and this is expected to enhance the electron transfer rate from the enzyme to the electrode. Several methods of covalent immobilization of enzymes onto a glassy carbon surface are described. We have chosen horse radish peroxidase enzyme in our study but any other suitable enzyme can be immobilized depending on the intended use. A three step procedure that includes (i) heat treatment of matrix at l00-l10°C to remove volatiles and absorbates, (ii) chemjcal pretreatment to introduce functional groups like -OH, -NO2, -Br etc. followed by (iii) glutaraldehyde coupling of the enzyme (for the nitrated matix after subsequent reduction) or modification of the matrix by carboxymethylation and enzyme coupling using carbodiimide (for hydroxylated matrix) was followed. The amount of enzyme immobilized onto the carbon surface was estimated by spectrophotometric enzymatic activity assay, commonly used for the soluble enzyme. We found that simple nitration did not introduce any significant amount of functional groups and the matrix with hydrogen peroxide pretreatment showed the highest enzyme loading of 0.05 U/mg of carbon matrix. The HRP enzyme electrode was tested in a rotating disk experiment for its response with the substrate.  相似文献   

4.
A disposable amperometric immunosensor was studied for the rapid detection of carp (Carassius auratus) Vitellogenin (Vtg). The sensor was fabricated based on screen-printed carbon arrays (SPCAs) containing eight carbon working and an integrated carbon counter electrodes. To construct the sensor, a conducting polymer (poly-terthiophene carboxylic acid) was electropolymerized on the surface of working electrodes and the polymer-coated SPCAs was characterized by SEM. Horseradish peroxidase (HRP) and a monoclonal antibody (anti-Vtg) specific to carp Vtg were covalently attached onto the polymer modified SPCAs. The immobilization of HRP and anti-Vtg onto the polymer-coated SPCAs was examined using cyclic voltammetry and quartz crystal microbalance studies. In order to detect the amount of Vtg, glucose oxidase (GOx)-labelled Vtg bound to the sensor surface under competition with the Vtg analyte was quantified amperometrically using glucose as a substrate. The performance of the eight sensors in arrays was evaluated by obtaining the calibration plots for Vtg. The sensor arrays exhibit a linear range of the Vtg concentration from 0.25 to 7.8 ng/ml and the detection limit was determined to be 0.09 ng/ml. Furthermore, the performance of the immunosensor for the determination of Vtg was evaluated by a standard addition method performed in fish serum samples.  相似文献   

5.
Screen-printed carbon electrodes modified with the dialdehydes, glutaraldehyde and terephthaldicarboxaldehyde, and then polyethyleneimine have been utilized for production of pesticide biosensors based on acetylcholinesterase. To improve the extent of dialdehyde modification, the electrodes were NH2-derivatized, initially by electrochemical reduction of 4-nitrobenzenediazonium to a nitroaryl radical permitting attachment to the carbon surface. Subsequent reduction of the 4-nitrobenzene yields a 4-aminobenzene modified carbon surface. Drosophila melanogaster acetylcholinesterase was immobilized either covalently onto dialdehyde modified electrodes or non-covalently onto polyethyleneimine modified electrodes. Internal diffusion limitations due to the dialdehyde and polyethyleneimine modifications increased the apparent Km of the immobilized enzyme. The thiocholine sensitivity was about 90% for dialdehyde modified electrodes and about 10% for polyethyleneimine modified electrodes as compared with non-modified carbon electrodes. The detection limit of the biosensors produced by non-covalent immobilization of acetylcholinesterase onto polyethyleneimine modified carbon electrodes was found to be about 10(-10) M for the organophosphate pesticide dichlorvos.  相似文献   

6.
A novel reagentless immunosensor was fabricated by immobilization of redox mediator 3,3',5,5'-tetramethylbenzidine (TMB) on the Nafion (Nf) film modified glassy carbon electrode. Gold nanoparticles were assembled onto the TMB/Nafion film modified electrode to provide active sites for the immobilization of antibody molecules. The antibody (anti-MIgG), in the present study, was fixed on the electrode for the rapid detection of antigen molecules (MIgG as a model analyte). The results showed that the immunosensor based on the immobilized TMB redox mediator exhibited good electrochemical response. A good linear relationship between peak current and the concentration of the MIgG was obtained in the concentration range from 4 to 120ng/mL. The detection limit was estimated to be 1ng/ml. Under the optimized conditions, the immunosensor exhibits good sensitivity, reproducibility and stability.  相似文献   

7.
A highly sensitive and selective amperometric hydrogen peroxide (H(2)O(2)) biosensor based on immobilization of hemoglobin (Hb) at multiwalled carbon nanotubes-zinc oxide (MWCNT/ZnO) composite modified glassy carbon electrode (GCE) is reported. ZnO microsponges were electrochemically grown on MWCNT surface by the simple, cost-effective, green, electrochemical method at room temperature. The MWCNT/ZnO/Hb composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E°') of -0.336V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.26s(-1). The developed biosensor showed a very fast response (>2s) toward H(2)O(2) with good sensitivity, wide linear range, and low detection limit of 0.02μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of MWCNT, and good biocompatibility of ZnO. The fabrication method of this biosensor is simple and effective for determination of H(2)O(2) in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery.  相似文献   

8.
A bienzymatic glucose biosensor was proposed for selective and sensitive detection of glucose. This mediatorless biosensor was made by simultaneous immobilization of glucose oxidase (GOD) and horseradish peroxidase (HRP) in an electropolymerized pyrrole (PPy) film on a single-wall carbon nanotubes (SWNT) coated electrode. The amperometric detection of glucose was assayed by potentiostating the bienzymatic electrode at -0.1 versus Ag/AgCl to reduce the enzymatically produced H(2)O(2) with minimal interference from the coexisting electroactive compounds. The single-wall carbon nanotubes, sandwiched between the enzyme loading polypyrrole (PPy) layer and the conducting substrate (gold electrode), could efficiently promote the direct electron transfer of HRP. Operational characteristics of the bienzymatic sensor, in terms of linear range, detection limit, sensitivity, selectivity and stability, were presented in detail.  相似文献   

9.
In this work, an electrochemiluminescence (ECL) sensor chip for sensitive detection of thrombin (TB) was prepared using a screen-printed electrode (SPE) as a working electrode and an aptamer as a specific recognition moiety. To produce an ECL sensor chip, a layer of pL-Cys was immobilized on the surface of the SPE using the cyclic voltammetry scanning method. A layer of gold nanoparticles (AuNPs) was assembled through an Au–S bond and hairpin DNA was further immobilized on the electrode surface. Ru(bpy)2(mcpbpy)2+, as a luminescent reagent, was covalently bound to single-stranded DNA (ssDNA) to prepare a luminescence probe ssDNA-Ru. The probe was hybridized with TB aptamer to form a capture probe. In the presence of TB, the TB aptamer in the capture probe bound to TB, causing the release of ssDNA-Ru that could bind to hairpin DNA on the electrode surface. The Ru(II) complex as a luminescent reagent was assembled onto the electrode, and pL-Cys was used as a co-reactant to enhance the ECL efficiency. The ECL signal of the sensor chip generated based on the above principles had a linear relationship with log TB concentration at the range 10 fM to1 nM, and the detection limit was 0.2 fM. Finally, TB detection using this method was verified using real blood samples. This work provides a new method using an aptamer as a foundation and SPE as a material for the detection of biological substances.  相似文献   

10.
A new xanthine (X) biosensors based on a hybrid nanocomposite containing multi-walled carbon nanotubes (MWCNT), Pt nanoparticles (PtNP) and gold nanoparticle (AuNP) was presented. X biosensor was fabricated by dropping AuNP/PtNP/MWCNT onto xanthine oxidase (XO) modified glassy carbon paste electrode (GCPE). Resulted XO/AuNP/PtNP/MWCNT/GCPE biosensor showed two linearity between 2.0 and 50 µM and 0.25 and 6.0 mM for X. RSD value was calculated as 2.46 (n = 5). Finally, the biosensor was applied to the X detection in synthetic serum samples and good recovery value was obtained.  相似文献   

11.
Electrochemical impedance measurements were used for the detection of single-strand DNA sequences using a peptide nucleic acid (PNA) probe layer immobilized onto Si/SiO2 chips. An epoxysilane layer is first immobilized onto the Si/SiO2 surface. The immobilization procedure consists of an epoxide/amine coupling reaction between the amino group of the PNA linker and the epoxide group of the silane. A 20-nucleotide sequence of PNA was used. Impedance measurements allow for the detection of the changes in charge distribution at the oxide/solution interface following modifications to the oxide surface. Due to these modifications, there are significant shifts in the semiconductor's flat-band potential after immobilization and hybridization. The results obtained using this direct and rapid approach are supported by fluorescence measurements according to classical methods for the detection of nucleic acid sequences.  相似文献   

12.
This paper describes the direct label-free detection of antibodies against the Epstein-Barr virus (anti-EBNA) using a surface plasmon resonance (SPR) biosensor. The antibody detection was performed using the immunoreaction between anti-EBNA and a respective synthetic peptide (EBNA-1), which was conjugated with bovine serum albumin (BSA-EBNA) and immobilized on the sensor surface. Three immobilization chemistries for the attachment of BSA-EBNA were investigated to optimize ligand density and minimize loss of EBNA-1 immunoreactivity. The developed SPR biosensor functionalized with the optimal immobilization method was calibrated and characterized in terms of detection limit, reproducibility, regenerability and storability. It was demonstrated that the sensor is capable of detecting concentrations of anti-EBNA as low as 0.2 ng/ml (approximately 1 pM) both in buffer and 1% human serum and can be stored and regenerated for repeated use.  相似文献   

13.
A new silver nanoparticles (AgNPs)/carboxylated multiwalled carbon nanotubes (c-MWCNT)/polyaniline (PANI) film has been synthesized on Au electrode using electrochemical techniques. The enzyme glutathione oxidase (GSHOx) (EC 1.8.3.3) was immobilized covalently on the surface of AgNPs/c-MWCNT/PANI/Au electrode to construct the glutathione biosensor. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and Fourier transform infrared (FTIR) spectrophotometry. The biosensor showed optimum response within 4s at +0.4V vs. Ag/AgCl, pH 6.0 and 35 °C, with a linear working range of 0.3-3500 μM and a detection limit of 0.3 μM. The glutathione biosensor was employed for measurement of glutathione content in hemolysated erythrocyte (RBC). The sensor was evaluated with 97.77% and 99.16% recovery of added glutathione in hemolysated RBC and 2.4% and 6.3% within and between batch coefficients of variation (CVs) respectively. The enzyme electrode lost 50% of its initial activity after 300 uses over a period of 3 months, when stored at 4 °C. The biosensor has the advantages over earlier biosensors in terms of greater stability, lower response time and no interference by a number of RBC hemolysate substances.  相似文献   

14.
An electrochemical enzyme electrode for dopa and dopamine was developed via an easy and effective immobilization method. The enzyme tyrosinase was extracted from a plant source Amorphophallus companulatus and immobilized in a novel composite of two biopolymers: agarose and guar gum. This composite matrix-containing enzyme forms a self-adhering layer on the active surface of glassy carbon electrode, making it a selective and sensitive phenol sensor. Dopa and dopamine were determined by the direct reduction of biocatalytically liberated quinone species at -0.18V versus Ag/AgCl (3M KCl). The analytical characteristics of this sensor, including linear range, lower detection limit, pH, and storage stability, are described. It has reusability up to 15 cycles and a shelf life of more than 2 months.  相似文献   

15.
A novel DNAzyme-functionalized Pt nanoparticles/carbon nanotubes (DNAzyme/Pt NPs/CNTs) bioconjugate was fabricated as trace tag for ultrasensitive sandwich DNA detection. The Pt NPs/CNTs were prepared via layer-by-layer (LBL) assembly of the Pt NPs and polyelectrolyte on the carboxylated CNTs, followed by the functionalization with the DNAzyme and reporter probe DNA through the platinum-sulfur bonding. The subsequent sandwich-type DNA specific reaction would confine numerous DNAzyme/Pt NPs/CNTs bioconjugate onto the gold electrode surface for amplifying the signal. In the presence of 3,3',5,5' tetramethylbenzidine (TMB) which could be oxidized by the DNAzyme, electrochemical signals could be generated by chronoamperometry via the interrogation of reduction electrochemical signal of oxidized TMB. The constructed DNA sensor exhibited a wide linear response to target DNA ranging from 1.0fM to 10pM with the detection limit down to 0.6fM and exhibited excellent selectivity against even a single base mismatch. In addition, this novel DNA sensor showed fairly good reproducibility, stability, and reusability.  相似文献   

16.
A chitosan-glutaraldehyde crosslinked uricase was immobilized onto Prussian blue nanoparticles (PBNPs) absorbed onto carboxylated multiwalled carbon nanotube (c-MWCNT) and polyaniline (PANI) layer, electrochemically deposited on the surface of Au electrode. The nanohybrid-uricase electrode was characterized by scanning electron microscopic (SEM), Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry. An amperometric uric acid biosensor was fabricated using uricase/c-MWCNT/PBNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The biosensor showed optimum response within 4 s at pH 7.5 and 40 °C, when operated at 0.4 V vs. Ag/AgCl. The linear working range for uric acid was 0.005-0.8 mM, with a detection limit of 5 μM. The sensor was evaluated with 96% recovery of added uric acid in sera and 4.6 and 5.4% within and between batch of coefficient of variation respectively and a good correlation (r = 0.99) with standard enzymic colorimetric method. This sensor measured uric acid in real serum samples. The sensor lost only 37% of its initial activity after its 400 uses over a period of 7 months, when stored at 4 °C.  相似文献   

17.
The electrochemical behavior of insulin at glassy carbon (GC) electrode modified with nickel oxide nanoparticles and guanine was investigated. Cyclic voltammetry technique has been used for electrodeposition of nickel oxide nanoparticles (NiOx) and immobilization of guanine on the surface GC electrode. In comparison to glassy carbon electrode modified with nickel oxide nanoparticles and bare GC electrode modified with adsorbed guanine, the guanine/nickel oxide nanoparticles/modified GC electrode exhibited excellent catalytic activity for the oxidation of insulin in physiological pH solutions at reduced overpotential. The modified electrode was applied for insulin detection using cyclic voltammetry or hydrodynamic amperometry techniques. It was found that the calibration curve was linear up to 4muM with a detection limit of 22pM and sensitivity of 100.9pA/pM under the optimized condition for hydrodynamic amperometry using a rotating disk modified electrode. In comparison to other electrochemical insulin sensors, this sensor shows many advantages such as simple preparation method without using any special electron transfer mediator or specific reagent, high sensitivity, excellent catalytic activity at physiological pH values, short response time, long-term stability and remarkable antifouling property toward insulin and its oxidation product. Additionally, it is promising for the monitoring of insulin in chromatographic effluents.  相似文献   

18.
A rapid, convenient and accurate method for the simultaneous detection of guanine (G), adenine (A), thymine (T) and cytosine (C) was developed at a multiwalled carbon nanotube (MWCNT)/choline (Ch) monolayer-modified glassy carbon electrode (GCE). X-ray photoelectron spectroscopy data demonstrated that Ch was covalently immobilised on the surface of GCE through oxygen atom. The Ch monolayer provides a positively charged surface with -N(+)(CH(3))(3) polar groups, so that it can attract negatively charged MWCNTs to the surface. Consequently, the MWCNT/Ch film exhibited remarkable electrocatalytic activities towards the oxidation of G, A, T and C due to the advantages of high electrode activity, large surface area, prominent antifouling property, and high electron transfer kinetics. All purine and pyrimidine bases showed well-defined catalytic oxidation peaks at MWCNT/Ch/GCE. The peak separations between G and A, A and T, and T and C are 270, 200, and 190 mV, respectively, which are sufficiently large for their potential recognition and simultaneous detection in mixture. Under the optimum conditions, the designed MWCNT/Ch/GCE exhibited low detection limit, high sensitivity and wide linear range for simultaneous detection of G, A, T and C. Moreover, the proposed method was successfully applied to the assessment of G, A, T and C contents in a herring sperm DNA sample with satisfactory results.  相似文献   

19.
A sensitive label-free electrochemical immunosensing platform was designed by a redox matrix of gold nanoparticles (GNPs), Azure І and multi-wall carbon nanotubes (MWCNT) self-assemblying nanocomposite. To construct the immunosensor, MWCNT was first dispersed in Nafion (Nf) to obtain a homogeneous solution and then it was dropped on the surface of the gold electrode (Au). Then the positively-charged redox molecule, Azure І, was entrapped into MWCNT–Nf film to form a redox nanostructural membrane. Next, the negatively charged gold nanoparticles (GNPs) were assembled to the interface through the electrostatic force. Finally, carcinoembryonic antibody molecules could be absorbed into the GNPs/Azure І/MWCNT–Nf immobilization matrix. Using carcinoembryonic antigen (CEA) as a model protein, the electrochemical immunosensor exhibited good stability and reproducibility, as well as good selectivity and storage stability. This strategy presented a promising platform for sensitive and facile monitoring of CEA.  相似文献   

20.
An amperometric lactate biosensor was developed based on a conducting polymer, poly-5,2′-5′,2′′-terthiophene-3′-carboxylic acid (pTTCA), and multiwall carbon nanotube (MWNT) composite on a gold electrode. Lactate dehydrogenase (LDH) and the oxidized form of nicotinamide adenine dinucleotide (NAD+) were subsequently immobilized onto the pTTCA/MWNT composite film. The modified electrode was characterized by quartz crystal microbalance (QCM), scanning electron microscopy (SEM), and electrochemical experiments. The detection signal was amplified by the pTTCA/MWNT assembly onto which a sufficient amount of enzyme was immobilized and stabilized by the covalent bond formation between the amine groups of enzyme and the carboxylic acid groups of the pTTCA/MWNT film. Experimental parameters affecting the sensor responses, such as applied potential, pH, and temperature, were assessed and optimized. Analytical performances and dynamic ranges of the sensor were determined, and the results showed that the sensitivity, stability, and reproducibility of the sensor improved significantly using pTTCA/MWNT composite film. The calibration plot was linear (r2 = 0.9995) over the range of 5 to 90 μM. The sensitivity was approximately 0.0106 μA/μM, with a detection limit of 1 μM, based on a signal/noise ratio of 3. The applicability of the sensor for the analysis of l-lactate concentration in commercial milk and human serum samples was demonstrated successfully.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号