首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Susceptibility of Legionella pneumophila to chlorine in tap water.   总被引:1,自引:9,他引:1       下载免费PDF全文
A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.  相似文献   

2.
Susceptibility of Legionella pneumophila to chlorine in tap water   总被引:7,自引:0,他引:7  
A study was conducted to compare the susceptibility of legionellae and coliforms to disinfection by chlorine. The chlorine residuals used were similar to concentrations that might be found in the distribution systems of large public potable water supplies. The effects of various chlorine concentrations, temperatures, and pH levels were considered. A number of different Legionella strains, both environmental and clinical, were tested. The results indicate that legionellae are much more resistant to chlorine than are coliform bacteria. At 21 degrees C, pH 7.6, and 0.1 mg of free chlorine residual per liter, a 99% kill of L. pneumophila was achieved within 40 min, compared with less than 1 min for Escherichia coli. The observed resistance is enhanced as conditions for disinfection become less optimal. The required contact time for the removal of L. pneumophilia was twice as long at 4 degrees C than it was at 21 degrees C. These data suggest that legionellae can survive low levels of chlorine for relatively long periods of time.  相似文献   

3.
A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.  相似文献   

4.
A model was developed to study the multiplication of various Legionella spp. in tap water containing Hartmannella vermiformis. Tap water cultures prepared with the following components were suitable for the multiplication studies: Legionella spp., 10(3) CFU/ml; H. vermiformis, 10(4.4) cysts per ml; and killed Pseudomonas paucimobilis, 10(9) cells per ml. Cocultures were incubated at 37 degrees C for at least 1 week. The following legionellae multiplied in tap water cocultures in each replicate experiment: L. bozemanii (WIGA strain), L. dumoffii (NY-23 and TX-KL strains), L. micdadei (two environmental strains), and L. pneumophila (six environmental strains and one clinical isolate). Growth yield values for these strains were 0.6 to 3.5 log CFU/ml. Legionellae which did not multiply in replicate cocultures included L. anisa (one strain), L. bozemanii (MI-15 strain), L. micdadei (a clinical isolate), L. longbeachae, (one strain), and L. pneumophila (Philadelphia 1 strain). L. gormanii and an environmental isolate of L. pneumophila multiplied in only one of three experiments. None of the legionellae multiplied in tap water containing only killed P. paucimobilis. The mean growth yield (+/- standard deviation) of H. vermiformis in the cocultures was 1.2 +/- 0.1 log units/ml. H. vermiformis supports multiplication of only particular strains of legionellae, some of which are from diverse origins.  相似文献   

5.
Tap water, from an experimental hot water system, containing a known virulent strain of Legionella pneumophila was stored in screw-capped bottles for 14 months. Viable counts showed survival of L. pneumophila and at least three other bacterial species. This reinforces the view that L. pneumophila can survive in stagnant water for relatively long periods of time.  相似文献   

6.
Tap water, from an experimental hot water system, containing a known virulent strain of Legionella pneumophila was stored in screw-capped bottles for 14 months. Viable counts showed survival of L. pneumophila and at least three other bacterial species. This reinforces the view that L. pneumophila can survive in stagnant water foatively long periods of time.  相似文献   

7.
[This corrects the article on p. 1333 in vol. 43.].  相似文献   

8.
9.
The factors involved in the survival of Legionella pneumophila in the microcosms of both hot spring water and tap water were studied by examining cultivability and metabolic activity. L. pneumophila could survive by maintaining metabolic activity but was noncultivable in all microcosms at 42 degrees C, except for one microcosm with a pH of <2.0. Lower temperatures supported survival without loss of cultivability. The cultivability declined with increasing temperature, although metabolic activity was observed at temperatures of up to 45 degrees C. The optimal range of pH for survival was between 6.0 and 8. The metabolic activity could be maintained for long periods even in microcosms with high concentrations of salt. The cultivability of organisms in the post-exponential phase in a tap water microcosm with a low inoculum size was more rapidly reduced than that of organisms in the exponential phase. In contrast, the loss of cultivability in microcosms of a high inoculum size was significant in the exponential phase. Random(ly) amplified polymorphic DNA analysis of microcosms where cultivability was lost but metabolic activity was retained showed no change compared to cells grown freshly, although an effect on the amplified DNA band pattern by production of stress proteins was expected. Resuscitation by the addition of Acanthamoeba castellanii to the microcosm in which cultivability was completely lost but metabolic activity was maintained was observed only in part of the cell population. Our results suggest that L. pneumophila cell populations can potentially survive as free organisms for long periods by maintaining metabolic activity but temporarily losing cultivability under strict environments and requiring resuscitation by ingestion by amoebas.  相似文献   

10.
In order to reduce the risks of Legionnaires' disease, caused by the bacterium Legionella pneumophila, disinfection of tap water systems contaminated with this bacterium is a necessity. This study investigates if electrochemical disinfection is able to eliminate such contamination. Hereto, water spiked with bacteria (10(4)CFU Escherichia coli or L. pneumophila/ml) was passed through an electrolysis cell (direct effect) or bacteria were added to tap water after passage through such disinfection unit (residual effect). The spiked tap water was completely disinfected, during passage through the electrolysis cell, even when only a residual free oxidant concentration of 0.07 mg/l is left (L. pneumophila). The residual effect leads to a complete eradication of cultivable E. coli, if after reaction time at least a free oxidant concentration of 0.08 mg/l is still present. Similar conditions reduce substantially L. pneumophila, but a complete killing is not realised.  相似文献   

11.
12.
Determination of the concentration of Legionella pneumophila in environmental water sites may be useful for the prediction of the risk of a particular site's causing Legionnaires' disease as well as for experimental studies of environmental growth or remediation. The precision and accuracy of recovery of two different L. pneumophila strains from seeded tap water samples were studied, with either filtration or centrifugation used to concentrate the bacteria. L. pneumophila grown on BCYE alpha agar or in Acanthamoeba castellanii was used to seed sterile tap water. Water samples were then either filtered (0.2-microns pore size) or centrifuged. An average of 53% (95% confidence interval [CI], 47 to 58%; n = 45) of the seeded L. pneumophila organisms were recovered by filtration with flat polycarbonate membranes. This recovery was significantly higher (P < 0.01) than that obtained by filtration with cast membranes (mean, 13%; 95% CI, 11 to 38%; n = 4) or by centrifugation at 3,800 x g for 30 min (mean, 14%; 95% CI, 2 to 25%; n = 9) or at 8,150 x g for 15 min (mean, 32%; 95% CI, 28 to 36%; n = 19). Recovery of L. pneumophila was not significantly different whether the bacteria were grown on plates or in amoebae. Use of a selective medium did not decrease the recovery efficiency, but preplating acid treatment of specimens caused an approximately 30% bacterial loss.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
Photosynthetic cyanobacteria, heterotrophic bacteria, free-living amoebae, and ciliated protozoa may support growth of Legionella pneumophila. Studies were done with two tap water cultures (WS1 and WS2) containing L. pneumophila and associated microbiota to characterize growth-supporting activity and assess the relative importance of the microbiota in supporting multiplication of L. pneumophila. The water cultures were incubated in the dark at 35 degrees C. The growth-supporting factor(s) was separated from each culture by filtration through 1-micron-pore-size membrane filters. The retentate was then suspended in sterile tap water. Multiplication of L. pneumophila occurred when both the retentate suspension and the filtrate from either culture were inoculated into sterile tap water. L. pneumophila did not multiply in tap water inoculated with only the filtrate, even though filtration did not reduce the concentration of L. pneumophila or heterotrophic bacteria in either culture. Growth-supporting activity of the retentate suspension from WS1 was inactivated at 60 degrees C but unaffected at 0, 25, and 45 degrees C after 30-min incubations. Filtration experiments indicated that the growth-supporting factor(s) in WS1 was 2 to 5 micron in diameter. Ciliated protozoa were not detected in either culture. Hartmannellid amoebae were conclusively demonstrated in WS2 but not in WS1. L. pneumophila multiplied in tap water inoculated with the amoebae (10(3)/ml) and the 1-micron filtrate of WS2. No multiplication occurred in tap water inoculated with the filtrate only. Growth-supporting activity for L. pneumophila may be present in plumbing systems; hartmannellid amoebae appear to be important determinants of multiplication of L. pneumophila in some tap water cultures.  相似文献   

14.
Photosynthetic cyanobacteria, heterotrophic bacteria, free-living amoebae, and ciliated protozoa may support growth of Legionella pneumophila. Studies were done with two tap water cultures (WS1 and WS2) containing L. pneumophila and associated microbiota to characterize growth-supporting activity and assess the relative importance of the microbiota in supporting multiplication of L. pneumophila. The water cultures were incubated in the dark at 35 degrees C. The growth-supporting factor(s) was separated from each culture by filtration through 1-micron-pore-size membrane filters. The retentate was then suspended in sterile tap water. Multiplication of L. pneumophila occurred when both the retentate suspension and the filtrate from either culture were inoculated into sterile tap water. L. pneumophila did not multiply in tap water inoculated with only the filtrate, even though filtration did not reduce the concentration of L. pneumophila or heterotrophic bacteria in either culture. Growth-supporting activity of the retentate suspension from WS1 was inactivated at 60 degrees C but unaffected at 0, 25, and 45 degrees C after 30-min incubations. Filtration experiments indicated that the growth-supporting factor(s) in WS1 was 2 to 5 micron in diameter. Ciliated protozoa were not detected in either culture. Hartmannellid amoebae were conclusively demonstrated in WS2 but not in WS1. L. pneumophila multiplied in tap water inoculated with the amoebae (10(3)/ml) and the 1-micron filtrate of WS2. No multiplication occurred in tap water inoculated with the filtrate only. Growth-supporting activity for L. pneumophila may be present in plumbing systems; hartmannellid amoebae appear to be important determinants of multiplication of L. pneumophila in some tap water cultures.  相似文献   

15.
Sixty-eight commercial bottled mineral waters (64 brands, 68 different 'best-before dates') were tested for the presence of bacteria and fungi. Six samples were Legionella antigen positive and six were Legionella pneumophila PCR positive. Two samples were both Legionella antigen and L. pneumophila PCR positive. Legionella cultures were negative. Although the PCR might have detected only dead Legionella cells, the PCR has been described to detect specifically viable but not culturable (VBNC) L. pneumophila cells as well. Whether VBNC bacteria may be present in bottled mineral waters and the risk for infection this may pose for severely immunocompromised patients should be investigated.  相似文献   

16.
Ecology of Legionella pneumophila within water distribution systems.   总被引:1,自引:10,他引:1       下载免费PDF全文
J E Stout  V L Yu    M G Best 《Applied microbiology》1985,49(1):221-228
The reservoir for hospital-acquired Legionnaires disease has been shown to be the potable water distribution system. We investigated the influence of the natural microbial population and sediment (scale and organic particulates) found in water systems as growth-promoting factors for Legionella pneumophila. Our in vitro experiments showed that: (i) water from hot-water storage tank readily supported the survival of L. pneumophila, (ii) the concentration of sediment was directly related to the survival of L. pneumophila, (iii) the presence of environmental bacteria improved the survival of L. pneumophila via nutritional symbiosis, (iv) the combination of sediment and environmental bacteria acted synergistically to improve the survival of L. pneumophila, and (v) the role of sediment in this synergistic effect was determined to be nutritional. Sediment was found to stimulate the growth of environmental microflora, which in turn stimulated the growth of L. pneumophila. These findings confirm the empiric observations of the predilection of L. pneumophila for growth in hot-water tanks and its localization to sediment. L. pneumophila occupies an ecological niche within the potable water system, with interrelationships between microflora, sediment, and temperature.  相似文献   

17.
Previous studies have shown that bacteria maintained in a low-nutrient "natural" environment such as swimming pool water are much more resistant to disinfection by various chemical agents than strains maintained on rich media. In the present study a comparison was made of the chlorine (Cl2) susceptibility of hot-water tank isolates of Legionella pneumophila maintained in tap water and strains passaged on either nonselective buffered charcoal-yeast extract or selective differential glycine-vancomycin-polymyxin agar medium. Our earlier work has shown that environmental and clinical isolates of L. pneumophila maintained on agar medium are much more resistant to Cl2 than coliforms are. Under the present experimental conditions (21 degrees C, pH 7.6 to 8.0, and 0.25 mg of free residual Cl2 per liter, we found the tap water-maintained L. pneumophila strains to be even more resistant than the agar-passaged isolates. Under these conditions, 99% kill of tap water-maintained strains of L. pneumophila was usually achieved within 60 to 90 min compared with 10 min for agar-passaged strains. Samples from plumbing fixtures in a hospital yielded legionellae which were "super"-chlorine resistant when assayed under natural conditions. After one agar passage their resistance dropped to levels of comparable strains which had not been previously exposed to additional chlorination. These studies more closely approximate natural conditions than our previous work and show that tap water-maintained L. pneumophila is even more resistant to Cl2 than its already resistant agar medium-passaged counterpart.  相似文献   

18.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

19.
The occurrence and viable counts of Legionella pneumophila in acid-treated water samples of 62 cooling towers on the main island of Japan were determined by inoculating them onto plates of Wadowsky-Yee-Okuda (WYO) agar medium. WYO plate cultures of 39 (63%) of the samples yielded L. pneumophila with viable counts ranging from 10 to 10(4) colony-forming units per 100 ml. Of the L. pneumophila isolates, 157 were serologically identified as serogroup 1, and the remaining 21 were agglutinated by serogroup 3 (2 strains) and serogroup 6 (19 strains) antisera. In each culture-positive water sample, the pH and the number of other bacteria were found not be statistically significantly correlated with the viable counts of L. pneumophila. However, a higher rate of recovery of L. pneumophila was obtained with the water samples with a smaller number of other bacteria. Practical use of commercially available antialgal or antimicrobial agents was found not to be significantly effective for controlling the occurrence and growth of L. pneumophila in cooling tower water.  相似文献   

20.
Ecology of Legionella pneumophila within water distribution systems   总被引:7,自引:0,他引:7  
The reservoir for hospital-acquired Legionnaires disease has been shown to be the potable water distribution system. We investigated the influence of the natural microbial population and sediment (scale and organic particulates) found in water systems as growth-promoting factors for Legionella pneumophila. Our in vitro experiments showed that: (i) water from hot-water storage tank readily supported the survival of L. pneumophila, (ii) the concentration of sediment was directly related to the survival of L. pneumophila, (iii) the presence of environmental bacteria improved the survival of L. pneumophila via nutritional symbiosis, (iv) the combination of sediment and environmental bacteria acted synergistically to improve the survival of L. pneumophila, and (v) the role of sediment in this synergistic effect was determined to be nutritional. Sediment was found to stimulate the growth of environmental microflora, which in turn stimulated the growth of L. pneumophila. These findings confirm the empiric observations of the predilection of L. pneumophila for growth in hot-water tanks and its localization to sediment. L. pneumophila occupies an ecological niche within the potable water system, with interrelationships between microflora, sediment, and temperature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏