首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Geometric and mechanical properties of human cervical spine ligaments   总被引:12,自引:0,他引:12  
This study characterized the geometry and mechanical properties of the cervical ligaments from C2-T1 levels. The lengths and cross-sectional areas of the anterior longitudinal ligament, posterior longitudinal ligament, joint capsules, ligamentum flavum, and interspinous ligament were determined from eight human cadavers using cryomicrotomy images. The geometry was defined based on spinal anatomy and its potential use in complex mathematical models. The biomechanical force-deflection, stiffness, energy, stress, and strain data were obtained from 25 cadavers using in situ axial tensile tests. Data were grouped into middle (C2-C5) and lower (C5-T1) cervical levels. Both the geometric length and area of cross section, and the biomechanical properties including the stiffness, stress, strain, energy, and Young's modulus, were presented for each of the five ligaments. In both groups, joint capsules and ligamentum flavum exhibited the highest cross-sectional area (p < 0.005), while the longitudinal ligaments had the highest length measurements. Although not reaching statistical significance, for all ligaments, cross-sectional areas were higher in the C5-T1 than in the C2-C5 group; and lengths were higher in the C2-C5 than in the C5-T1 group with the exception of the flavum (Table 1 in the main text). Force-deflection characteristics (plots) are provided for all ligaments in both groups. Failure strains were higher for the ligaments of the posterior (interspinous ligament, joint capsules, and ligamentum flavum) than the anterior complex (anterior and posterior longitudinal ligaments) in both groups. In contrast, the failure stress and Young's modulus were higher for the anterior and posterior longitudinal ligaments compared to the ligaments of the posterior complex in the two groups. However, similar tendencies in the structural responses (stiffness, energy) were not found in both groups. Researchers attempting to incorporate these data into stress-analysis models can choose the specific parameter(s) based on the complexity of the model used to study the biomechanical behavior of the human cervical spine.  相似文献   

2.
Effects of postmortem storage by freezing on ligament tensile behavior   总被引:17,自引:0,他引:17  
The purpose of this study is to examine the effect of prolonged postmortem freezing storage (between 1 1/2 and 3 months at -20 degrees C) on the structural properties of the medial collateral ligament (MCL)-bone complex as well as the mechanical properties of the MCL substance from the rabbit knee. Tensile testing of the femur-MCL-tibia specimen was performed and no statistically significant changes were noted between the fresh and stored samples in terms of the cyclic stress relaxation, the load-deformation characteristics, as well as the load, deformation and energy absorbing capability at failure. The area of hysteresis of the stored samples was significantly reduced in the first few cycles, however. The mechanical properties of the MCL substance, as represented by the stress-strain curves, tensile strength and ultimate strain also did not change following storage. We conclude, therefore, proper and careful storage by freezing would have little or no effect on the biomechanical properties of the ligaments.  相似文献   

3.
Many lumbar spine surgeries either intentionally or inadvertently damage or transect spinal ligaments. The purpose of this work was to quantify the previously unknown biomechanical consequences of isolated spinal ligament transection on the remaining spinal ligaments (stress transfer), vertebrae (bone remodelling stimulus) and intervertebral discs (disc pressure) of the lumbar spine. A finite element model of the full lumbar spine was developed and validated against experimental data and tested in the primary modes of spinal motion in the intact condition. Once a ligament was removed, stress increased in the remaining spinal ligaments and changes occurred in vertebral strain energy, but disc pressure remained similar. All major biomechanical changes occurred at the same spinal level as the transected ligament, with minor changes at adjacent levels. This work demonstrates that iatrogenic damage to spinal ligaments disturbs the load sharing within the spinal ligament network and may induce significant clinically relevant changes in the spinal motion segment.  相似文献   

4.
The fascicle material properties in bone-fascicle-bone units were determined for the anterior and posterior cruciate ligaments (ACL, PCL), the lateral collateral ligament (LCL) and the patellar tendon (PT) from three young human donor knees. Groups of fascicles from each tissue were isolated with intact bone ends and failed at a high strain rate in a saline bath at 37 degrees C. In each knee tested the load related material properties (linear modulus, maximum stress and energy density to maximum stress) for the patellar tendon were significantly larger than corresponding values for the cruciate and collateral ligaments. Bundles from different ligaments in the same knee were similar to each other in their mechanical behavior. In addition, no significant differences were present in the maximum strains recorded for any of the four tissue types examined. The results presented have implications in studies of ligament injury. They are also important in the design and use of synthetic and biological ligament replacements and in tissue and whole knee modeling.  相似文献   

5.
On modelling nonlinear viscoelastic effects in ligaments   总被引:2,自引:0,他引:2  
  相似文献   

6.
The knee ligaments and patellar tendon function in concert with each other and other joint tissues, and are adapted to their specific physiological function via geometry and material properties. However, it is not well known how the viscoelastic and quasi-static material properties compare between the ligaments. The purpose of this study was to characterize and compare these material properties between the knee ligaments and patellar tendon.Dumbbell-shaped tensile test samples were cut from bovine knee ligaments (ACL, LCL, MCL, PCL) and patellar tendon (PT) and subjected to tensile testing (n = 10 per ligament type). A sinusoidal loading test was performed at 8% strain with 0.5% strain amplitude using 0.1, 0.5 and 1 Hz frequencies. Subsequently, an ultimate tensile test was performed to investigate the stress-strain characteristics.At 0.1 Hz, the phase difference between stress and strain was higher in LCL compared with ACL, PCL and PT (p < 0.05), and at 0.5 Hz that was higher in LCL compared with all other ligaments and PT (p < 0.05). PT had the longest toe-region strain (p < 0.05 compared with PCL and MCL) and MCL had the highest linear and strain-dependent modulus, and toughness (p < 0.05 compared with ACL, LCL and PT).The results indicate that LCL is more viscous than other ligaments at low-frequency loads. MCL was the stiffest and toughest, and its modulus increased most steeply at the toe-region, possibly implying a greater amount of collagen. This study improves the knowledge about elastic, viscoelastic and failure properties of the knee ligaments and PT.  相似文献   

7.
Many factors may affect symbiont distributions within host populations. Intrinsic factors, such as genotype, body condition and age may account for variations in symbiont loads between individuals . However, abiotic factors may also contribute to variations. We investigated correlates of variation in the number of feather mites, Trouessartia sp. (Trouessartiidae), per individual in the Seychelles Warbler Acrocephalus sechellensis on Cousin Island. Warblers from territories exposed to high levels of salt spray had lower feather mite loads than warblers from territories unaffected by salt spray, and juveniles had higher mite loads than adults. When the effects of salt spray were controlled for statistically, incubating birds had lower mite loads than birds in other stages of reproduction. Thus, an extrinsic and two intrinsic factors contribute to predicting feather mite loads.  相似文献   

8.
During positive-pressure ventilation parenchymal deformation can be assessed as strain (volume increase above functional residual capacity) in response to stress (transpulmonary pressure). The aim of this study was to explore the relationship between stress and strain on the regional level using computed tomography in anesthetized healthy pigs in two postures and two patterns of breathing. Airway opening and esophageal pressures were used to calculate stress; change of gas content as assessed from computed tomography was used to calculate strain. Static stress-strain curves and dynamic strain-time curves were constructed, the latter during the inspiratory phase of volume and pressure-controlled ventilation, both in supine and prone position. The lung was divided into nondependent, intermediate, dependent, and central regions: their curves were modeled by exponential regression and examined for statistically significant differences. In all the examined regions, there were strong but different exponential relations between stress and strain. During mechanical ventilation, the end-inspiratory strain was higher in the dependent than in the nondependent regions. No differences between volume- and pressure-controlled ventilation were found. However, during volume control ventilation, prone positioning decreased the end-inspiratory strain of dependent regions and increased it in nondependent regions, resulting in reduced strain gradient. Strain is inhomogeneously distributed within the healthy lung. Prone positioning attenuates differences between dependent and nondependent regions. The regional effects of ventilatory mode and body positioning should be further explored in patients with acute lung injury.  相似文献   

9.
In this study, a progressive loading regimen (load–dwell–unloading–dwell–reloading) was applied on bone samples to examine the compressive post-yield response of bone at increasing strain levels. Cortical bone specimens from human tibiae of two age groups (middle-aged group: 53±2 years, 4 females and 4 males, elderly group: 83±6 years, 4 females and 4 males) were loaded in compression using the progressive loading scheme. Modulus degradation, plastic deformation, viscous response, and energy dissipation of bone during post-yield deformation were assessed. Although initial modulus was not significantly different between the two age groups, the degradation of modulus with the applied strain in the elderly group was faster than in the middle-aged group. The modulus loss (or microdamage accumulation) of bone occurred prior to plastic deformation. Plastic strain had a similar linear relationship with the applied strain for both middle-aged and the elderly group although middle-aged bone yielded at a greater strain. The viscoelastic time constant changed similarly with increasing strain for the two groups, whereas a higher magnitude of stress relaxation was observed in the middle-aged group. Energy dissipation was investigated through three pathways: elastic release strain energy, hysteresis energy, and plastic strain energy. The middle-aged group had significantly greater capacity of energy dissipation than the elderly group in all three pathways. The information obtained may provide important insights in age-related effects on bone fragility.  相似文献   

10.
The majority of foot deformities are related to arch collapse or instability, especially the longitudinal arch. Although the relationship between the plantar fascia and arch height has been previously investigated, the stress distribution remains unclear. The aim of this study was to explore the role of the plantar ligaments in foot arch biomechanics. We constructed a geometrical detailed three-dimensional (3-D) finite element (FE) model of the human foot and ankle from computer tomography images. The model comprised the majority of joints in the foot as well as bone segments, major ligaments, and plantar soft tissue. Release of the plantar fascia and other ligaments was simulated to evaluate the corresponding biomechanical effects on load distribution of the bony and ligamentous structures. These intrinsic ligaments of the foot arch were sectioned to simulate different pathologic situations of injury to the plantar ligaments, and to explore bone segment displacement and stress distribution. The validity of the 3-D FE model was verified by comparing results with experimentally measured data via the displacement and von Mise stress of each bone segment. Plantar fascia release decreased arch height, but did not cause total collapse of the foot arch. The longitudinal foot arch was lost when all the four major plantar ligaments were sectioned simultaneously. Plantar fascia release was compromised by increased strain applied to the plantar ligaments and intensified stress in the midfoot and metatarsal bones. Load redistribution among the centralized metatarsal bones and focal stress relief at the calcaneal insertion were predicted. The 3-D FE model indicated that plantar fascia release may provide relief of focal stress and associated heel pain. However, these operative procedures may pose a risk to arch stability and clinically may produce dorsolateral midfoot pain. The initial strategy for treating plantar fasciitis should be non-operative.  相似文献   

11.
BACKGROUND: Static deformation analysis and estimation of wall stress distribution of patient-specific cerebral aneurysms can provide useful insights into the disease process and rupture. METHOD OF APPROACH: The three-dimensional geometry of saccular cerebral aneurysms from 27 patients (18 unruptured and nine ruptured) was reconstructed based on computer tomography angiography images. The aneurysm wall tissue was modeled using a nonlinear, anisotropic, hyperelastic material model (Fung-type) which was incorporated in a user subroutine in ABAQUS. Effective material fiber orientations were assumed to align with principal surface curvatures. Static deformation of the aneurysm models were simulated assuming uniform wall thickness and internal pressure load of 100 mm Hg. RESULTS: The numerical analysis technique was validated by quantitative comparisons to results in the literature. For the patient-specific models, in-plane stresses in the aneurysm wall along both the stiff and weak fiber directions showed significant regional variations with the former being higher. The spatial maximum of stress ranged from as low as 0.30 MPa in a small aneurysm to as high as 1.06 MPa in a giant aneurysm. The patterns of distribution of stress, strain, and surface curvature were found to be similar. Sensitivity analyses showed that the computed stress is mesh independent and not very sensitive to reasonable perturbations in model parameters, and the curvature-based criteria for fiber orientations tend to minimize the total elastic strain energy in the aneurysms wall. Within this small study population, there were no statistically significant differences in the spatial means and maximums of stress and strain values between the ruptured and unruptured groups. However, the ratios between the stress components in the stiff and weak fiber directions were significantly higher in the ruptured group than those in the unruptured group. CONCLUSIONS: A methodology for nonlinear, anisotropic static deformation analysis of geometrically realistic aneurysms was developed, which can be used for a more accurate estimation of the stresses and strains than previous methods and to facilitate prospective studies on the role of stress in aneurysm rupture.  相似文献   

12.
The muscular-hydrostat model of tongue function proposes a constant interaction of extrinsic (external bony attachment, insertion into base of tongue) and intrinsic (origin and insertion within the tongue) tongue muscles in all tongue movements (Kier WM and Smith KK. Zool J Linn Soc 83: 207-324, 1985). Yet, research that examines the respiratory-related effects of tongue function in mammals continues to focus almost exclusively on the respiratory control and function of the extrinsic tongue protrusor muscle, the genioglossus muscle. The respiratory control and function of the intrinsic tongue muscles are unknown. Our purpose was to determine whether intrinsic tongue muscles have a respiration-related activity pattern and whether intrinsic tongue muscles are coactivated with extrinsic tongue muscles in response to respiratory-related sensory stimuli. Esophageal pressure and electromyographic (EMG) activity of an extrinsic tongue muscle (hyoglossus), an intrinsic tongue muscle (superior longitudinal), and an external intercostal muscle were studied in anesthetized, tracheotomized, spontaneously breathing rats. Mean inspiratory EMG activity was compared at five levels of inspired CO2. Intrinsic tongue muscles were often quiescent during eupnea but active during hypercapnia, whereas extrinsic tongue muscles were active in both eupnea and hypercapnia. During hypercapnia, the activities of the airway muscles were largely coincident, although the onset of extrinsic muscle activity generally preceded the onset of intrinsic muscle activation. Our findings provide evidence, in an in vivo rodent preparation, of respiratory modulation of motoneurons supplying intrinsic tongue muscles. Distinctions noted between intrinsic and extrinsic activities could be due to differences in motoneuron properties or the central, respiration-related control of each motoneuron population.  相似文献   

13.
Lung tissue presents substantial nonlinear phenomena not accounted for by linear models; however, nonlinear approaches are less available. Our aim was to characterize the behavior of total harmonic distortion, an index of nonlinearity, in lung tissue strips under sinusoidal deformation at a single frequency as a function of strain amplitude and operational stress. To that end, lung parenchymal strips from healthy rats (n = 6) were subjected to sinusoidal deformation (1 Hz) at different strain amplitudes (Δε = 4, 8, 12, 16, and 20%) and operating stresses (σ(op) = 6, 8, 10, 12, 14, and 16 hPa). Additional rats (n = 9) were intratracheally instilled with saline or bleomycin (2.5 U/kg, 3 times 1 wk apart), killed 28 days after the last instillation, and their lung tissue strips were studied at 5 and 10 hPa σ(op) and 5% Δε. In both cases, harmonic distortion (HD%) of input (strain) and output (stress) signals were determined. In healthy strips, HD% increased linearly with Δε, stress amplitude, and minimum stress by cycle variations, but showed no significant change with σ(op) levels. A prediction model could be determined as a function of operational stress and stress amplitude. Harmonic distortion was significantly increased in bleomycin-treated strips compared with controls and showed positive correlation with E behavior in both normal and diseased strips. We concluded that HD% can be useful as a single and simple parameter of lung tissue nonlinearity.  相似文献   

14.
The cervical spine functions as a complex mechanism that responds to sudden loading in a unique manner, due to intricate structural features and kinematics. The spinal load-sharing under pure compression and sagittal flexion/extension at two different impact rates were compared using a bio-fidelic finite element (FE) model of the ligamentous cervical functional spinal unit (FSU) C2–C3. This model was developed using a comprehensive and realistic geometry of spinal components and material laws that include strain rate dependency, bone fracture, and ligament failure. The range of motion, contact pressure in facet joints, failure forces in ligaments were compared to experimental findings. The model demonstrated that resistance of spinal components to impact load is dependent on loading rate and direction. For the loads applied, stress increased with loading rate in all spinal components, and was concentrated in the outer intervertebral disc (IVD), regions of ligaments to bone attachment, and in the cancellous bone of the facet joints. The highest stress in ligaments was found in capsular ligament (CL) in all cases. Intradiscal pressure (IDP) in the nucleus was affected by loading rate change. It increased under compression/flexion but decreased under extension. Contact pressure in the facet joints showed less variation under compression, but increased significantly under flexion/extension particularly under extension. Cancellous bone of the facet joints region was the only component fractured and fracture occurred under extension at both rates. The cervical ligaments were the primary load-bearing component followed by the IVD, endplates and cancellous bone; however, the latter was the most vulnerable to extension as it fractured at low energy impact.  相似文献   

15.
In this investigation, deciduous teeth (canines, c; first molars, m1; second molars, m2) and their permanent successors (canines, C; first premolars, P1; second premolars, P2) were used to test two related hypotheses about fluctuating asymmetry (FA). First, based on the biology of the developing dentition, it was predicted that deciduous teeth would be more developmentally stable and thus exhibit less dimensional FA than their permanent successors. Second, based on sex differences in tooth development, it was predicted that female canines would have greater developmental stability (less FA) than male canines. Bucco-lingual measurements were made on dental casts from a single Gullah population. Using a repeated-measures study design (n = 3 repeated measures), we tested these hypotheses on sample sizes ranging from 63-82 antimeric pairs. Neither hypothesis was supported by our data. In most cases, Gullah deciduous teeth did not exhibit statistically significantly less FA than their permanent successors; indeed, statistically significant differences were found for only 3 of 12 deciduous vs. permanent contrasts, and in two cases, the deciduous tooth had greater FA. Female mandibular canines exhibited statistically significantly greater FA than those of males, while there was no statistically significant sex difference in FA for the maxillary canine. FA in these Gullah samples is high when compared to Archaic and late prehistoric Ohio Valley Native Americans, consistent with historical and archaeological evidence that environmental stress was relatively higher in the Gullah population. We suggest that when environmental stress in a population is high, the impact of differences in tooth formation time spans and developmental buffering upon FA may be minor relative to the effect of developmental noise.  相似文献   

16.
Damage of the annulus fibrosus is implicated in common spinal pathologies. The objective of this study was to obtain a quantitative relationship between both the number of cycles and the magnitude of tensile strain resulting in damage to the annulus fibrosus. Four rectangular tensile specimens oriented in the circumferential direction were harvested from the outer annulus of 8 bovine caudal discs (n = 32) and subjected to one of four tensile testing protocols: (i) ultimate tensile strain (UTS) test; (ii) baseline cyclic test with 4 series of 400 cycles of baseline cyclic loading (peak strain = 20% UTS); (iii & iv) acute and fatigue damage cyclic tests consisting of 4 x 400 cycles of baseline cyclic loading with intermittent loading to 1 and 100 cycles, respectively, with peak tensile strain of 40%, 60%, and 80% UTS. Normalized peak stress for all mechanically loaded specimens was reduced from 0.89 to 0.11 of the baseline control levels, and depended on the magnitude of damaging strain and number of cycles at that damaging strain. Baseline, acute, and fatigue protocols resulted in permanent deformation of 3.5%, 6.7% and 9.6% elongation, respectively. Damage to the laminate structure of the annulus in the absence of biochemical activity in this study was assessed using histology, transmission electron microscopy, and biochemical measurements and was most likely a result of separation of annulus layers (i.e., delamination). Permanent elongation and stress reduction in the annulus may manifest in the motion segment as sub-catastrophic damage including increased neutral zone, disc bulging, and loss of nucleus pulposus pressure. The preparation of rectangular tensile strip specimens required cutting of collagen fibers and may influence absolute values of results, however, it is not expected to affect the comparisons between loading groups or dose-response reported.  相似文献   

17.
Subfailure damage in ligaments was evaluated macroscopically from a structural perspective (referring to the entire ligament as a structure) and microscopically from a cellular perspective. Freshly harvested rat medial collateral ligaments (MCLs) were used as a model in ex vivo experiments. Ligaments were preloaded with 0.1 N to establish a consistent point of reference for length (and strain) measurements. Ligament structural damage was characterized by nonrecoverable difference in tissue length after a subfailure stretch. The tissue's mechanical properties (via stress vs. strain curves measured from a preloaded state) after a single subfailure stretch were also evaluated (n = 6 pairs with a different stretch magnitude applied to each stretched ligament). Regions containing necrotic cells were used to characterize cellular damage after a single stretch. It should be noted that the number of damaged cells was not quantified and the difference between cellular area and area of fluorescence is not known. Structural and cellular damage were represented and compared as functions of subfailure MCL strains. Statistical analysis indicated that the onset of structural damage occurs at 5.14% strain (referenced from a preloaded length). Subfailure strains above the damage threshold changed the shape of the MCL stress-strain curve by elongating the toe region (i.e., increasing laxity) as well as decreasing the tangential modulus and ultimate stress. Cellular damage was induced at ligament strains significantly below the structural damage threshold. This cellular damage is likely to be part of the natural healing process in mildly sprained ligaments.  相似文献   

18.
Several oxidative and non-oxidative stresses were applied to two transgenic strains of Drosophila melanogaster (designated P(bSOD)5 and P(bSOD)11) that express superoxide dismutase (SOD) at elevated levels, and control strains that express normal SOD levels. Transgenic strain P(bSOD)5 exposed to paraquat (1,1'-dimethyl-4,4'-bipyridinium dichloride), a redox cycling agent that generates superoxide anion when metabolized in vivo, was significantly more resistant to this xenobiotic than control flies. When test flies were subjected to 100% oxygen for 20 min each day, the mean lifespan was 3.62 days for control strain 25, but 4.35 days for both transgenic strains. The mortality curves of all strains fed 1% H2O2 were similar, but the median lifespan of 72 h for controls and 64 h for transgenics suggests that the transgenic flies were slightly more sensitive to H2O2. The activity of catalase was the same for all strains. Using starvation resistance as a non-oxidative stress, flies maintained on water without any food had identical survival curves; for all strains, the median lifespan was 72 h. Throughout the lifespan, no statistically significant difference in physical activity was displayed for transgenic versus control flies. Collectively, these data suggest that the increased lifespan previously observed in SOD transgenics is specifically related to resistance to oxidative stresses.  相似文献   

19.
The success rate of reconstructing the Anterior Cruciate Ligament (ACL) with prosthetic ligaments is currently low both in humans and animals. The stress distribution in prosthetic ligaments that causes failure is very complex and not yet understood. Therefore, we have begun to develop a Finite Element Model of a prosthetic ACL. Here we describe the normal and contact stresses in Dacron(TM) yarn (a multi-fibrillar structure) using input data based on experimental measurements of the load and strain of six designed yarns. The results show that the normal and contact stresses in the fibres of the ACL yarn are directly proportional to the yarn strains. Increasing the twisting length (transverse deformation) of the yarn increases the normal stress in the fibres and the yarn modulus, but decreases the contact stresses between the fibres. The structural properties of a yarn are dependent on the specific arrangement of various filament types. Increasing the distance between the longitudinal (symmetry) axes of the filaments and the axis of symmetry of the yarn decreases the stresses.  相似文献   

20.
A new nonlinear constitutive model for the three-dimensional stress relaxation of articular ligaments is proposed. The model accounts for finite strains, anisotropy, and strain-dependent stress relaxation behavior exhibited by these ligaments. The model parameters are identified using published uniaxial stress–stretch and stress relaxation data on human medial collateral ligaments (MCLs) subjected to tensile tests in the fiber and transverse to the fiber directions (Quapp and Weiss in J Biomech Eng Trans ASME 120:757–763, 1998; Bonifasi-Lista et al. in J Orthop Res 23(1):67–76, 2005). The constitutive equation is then used to predict the nonlinear elastic and stress relaxation response of ligaments subjected to shear deformations in the fiber direction and transverse to the fiber direction, and an equibiaxial extension. A direct comparison with stress relaxation data collected by subjecting human MCLs to shear deformation in the fiber direction is presented in order to demonstrate the predictive capabilities of the model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号