首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
For the assay of the antidepressant compound mianserin hydrochloride (Org GB 94) in human plasma, a mass fragmentographic method, using the deuterated analogue as internal standard and a high-performance liquid chromatographie sample clean-up procedure has been developed. The assay specifications obtained are a lower limit for reliable measurements of 1 ng/ml, an accuracy of ca. 0.01 ng/ml, a precision of 6–7% and a capacity of about 60 samples per day. The applicability of the assay method is illustrated by measurements of single-dose and steady-state plasma levels in clinical experiments, demonstrating the possibility of monitoring plasma levels during at least 24 h after a single dose of 15 mg of Org GB 94. The mean steady-state plasma levels after a daily dose of 3 × 20 mg of Org GB 94 appeared to be remarkably constant with time: 38, 36 and 34 ng/ml after 2, 4 and 6 weeks of treatment of 18 depressed patients.  相似文献   

2.
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples. Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45°C and UV detection at 240 nm. Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5–110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously.  相似文献   

3.
This paper describes a sensitive HPLC-electrochemical detection analytical method for determining the concentration of the intravenous anesthetic, propofol, in human or rat plasma or serum and a variety of rat tissues. Internal standard and drug are extracted from serum or plasma and other tissues with pentane. 2,6-tert.-Butylmethylphenol is used as internal standard. It includes a novel steam distillation procedure for separating the highly lipophilic propofol from skin and fat. The plasma/serum assay has a precision of 1–4% (C.V.) in the range 10 ng/ml to 1 μg/ml and permits the assay of 5 ng/ml from 0.1 ml of plasma/serum. The tissue procedure allows the estimation of 50 ng/g in 0.1 g of tissue for most of the major organs with less than 2% (C.V.) precision. This assay was used to measure propofol concentrations in plasma/serum and tissue samples in support of a project to develop a physiological pharmacokinetic model for propofol in the rat.  相似文献   

4.
A high-performance capillary electrophoresis (HPCE) assay was used to determine the concentration of a potent cytotoxic agent, dolastatin-10, in human plasma. Following extraction from plasma, using a solid-phase C18 cartridge, capillary zone electrophoresis was used to separate, detect and quantitate dolastatin-10 using the structurally related compound dolastatin-15 as the internal standard. Migration times for both dolastatins are less than 20 min. The recovery of the drug was approximately 90% and was quantified over the assay range of 39 to 5000 ng/ml with good precision and accuracy. The method is linear up to 5000 ng/ml with a lower limit of detection of 25 ng/ml. Data resulting from the use of the assay for the in vitro metabolism of the drug are presented. This is the first report of a validated HPCE assay for determining dolastatin-10 levels in human plasma.  相似文献   

5.
A method is described for the determination of the two enantiomers of mirtazapine in human blood plasma by high-performance liquid chromatography. Measurements were performed on drug free plasma spiked with mirtazapine and used to prepare and validate standard curves. Levels of enantiomers of mirtazapine were also measured in patients being treated for depression with racemic mirtazapine. Mirtazapine was separated from plasma by solid-phase extraction using CERTIFY columns. Chromatographic separation was achieved using a Chiralpak AD column and pre-column and compounds were detected by their absorption at 290 nm. Imipramine was used as an internal standard. The assay was validated for each analyte in the concentration range 10–100 ng/ml. The coefficient of variance was 16% and 5.5% for(+)-mirtazapine for 10 and 100 ng/ml control specimens respectively and 15% and 7.3% for mirtazapine for 10 and 100 ng/ml control specimens respectively. This assay is appropriate for use in the clinical range. The range of plasma mirtazapine concentrations from eleven patients taking daily doses of 30–45 mg of racemate was <5 to 69 ng/ml for (+)-mirtazapine and 13–88 ng/ml for (−)-mirtazapine for blood specimens collected 10–17.5 h after taking the dose.  相似文献   

6.
Circulating concentrations of mevalonic acid (MVA) change in parallel with, and may be used as a marker of cholesterol biosynthesis. Plasma MVA levels have been quantified using a sensitive and specific capillary gas chromatography-electron capture mass spectrometric assay. The detection limit for MVA in plasma is 100 pg/ml; the intra-assay variation is 5.11%; the inter-assay variation is 7.7%. Using this assay, the mean plasma MVA in 15 normolipidemic subjects was 2.37 +/- 1.2 ng/ml (range 0.41-5.31 ng/ml). Administration of 40 mg of simvastatin (an HMG-CoA reductase inhibitor) significantly accenutated the diurnal decrease in plasma MVA levels. This assay may be useful in investigating cholesterol synthesis rates in different dyslipidemias and individual responses of HMG-CoA reductase-inhibiting drugs.  相似文献   

7.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

8.
A new high-performance liquid chromatographic method for the simultaneous determination of indinavir, saquinavir and ritonavir in human plasma is described. Quantitative recovery following liquid–liquid extraction with diethyl ether from 500 μl of human plasma was achieved. Subsequently, the assay was performed with a linear gradient starting at 67 mM potassium dihydrogenphosphate–acetonitrile (65:35 to 40:60, v/v) as a mobile phase, a Phenomenex C18 column and UV detection at 240 and 258 nm, respectively. Linear standard curves were obtained for concentrations ranging from 75 to 20 000 ng/ml for indinavir, from 10 to 6000 ng/ml for saquinavir, and from 45 to 30 000 ng/ml for ritonavir. The calculated intra- and inter-day coefficients of variation were below 6%.  相似文献   

9.
Andoh T 《Zoological science》2005,22(9):1023-1030
A time-resolved fluoroimmunoassay system (TR-FIA) for measuring flounder insulin-like growth factor-I (IGF-I) was developed using biotinylated flounder IGF-I, anti-fish IGF-I antiserum and europium-avidin conjugate. The detection limit per well was <5 pg/well corresponding to <0.5 ng/ml in a basic procedure for sample of 10 microl/well and to <0.08 ng/ml in a procedure modified for high volume samples (up to 70 microl/well). Specificity of the assay was validated using various IGF-Is and insulins. All IGFs except seabream IGF-I showed very low or no crossreactivity. Binding inhibition curves for flounder and seabream IGF-Is were completely identical to each other. Intra- and interassay variations ranged from coefficients of variations of 3.9% to 7.2%. Recovery tests using barfin flounder plasma varied from 82.7 to 101.6% in the added range from 20 to 160 ng/ml. This assay system was applied for measuring total plasma IGF-I in barfin flounder injected porcine growth hormone (GH). A group injected with GH at the dose of 0.05 IU/gBW showed a significant increase of total plasma IGF-I compared with those of albumin-injected (control) and initial groups. In addition, I was able to substitute time-resolved fluorometric detection in this assay system with enzymatic fluorometric detection (FIA). Binding inhibition curve for flounder IGF-I in this substituted assay system showed equal performance with that of the TR-FIA system. Correlation of IGF-I levels between TR-FIA and FIA was high (r(2)=0.957) in plasma samples from barfin flounders in various physiological conditions. Thus, the present study shows precision and efficiency of two non-radioisotopic immunoassay systems for measuring flounder IGF-I.  相似文献   

10.
A sensitive, specific and precise HPLC–UV assay was developed to quantitate cocaine (COC) and its metabolites benzoylecgonine (BE), norcocaine (NC) and cocaethylene (CE) in rat plasma. After adding 50 μl of the internal standard solution (bupivacaine, 8 μg/ml) and 500 μl of Sørensen's buffer (pH 6) to 100 μl of rat plasma sample, the mixture was extracted with 10 ml of chloroform. The organic layer was transferred to a clean test tube and was evaporated under nitrogen. The residue was reconstituted in 100 μl of mobile phase and 35 μl was injected onto the HPLC column. The mobile phase consisted of methanol–acetonitrile–50 mM monobasic ammonium phosphate (5:7:63, v/v/v) and was maintained at a flow-rate of 0.4 ml/min. Separation of COC and its metabolites was achieved using a Supelcosil ABZ+plus deactivated reversed-phase column (250×2.1 mm I.D., 5 μm). Calibration curves were linear over the range of 25–5000 ng/ml for COC and its three metabolites. The absolute extraction efficiencies for BE, COC, NC, CE and bupivacaine were 56.6%, 78.6%, 61.1%, 76.4% and 67.0%, respectively. COC and its metabolites were stable in mobile phase for 24 h at room temperature and in rat plasma for 2 weeks at −20°C. The limits of detection for BE, COC, NC and CE were 20, 24, 15 and 12.9 ng/ml, respectively. These values correspond to 0.70, 0.84, 0.525 and 0.452 ng of the according compound being injected on column. The within-day coefficient of variation for the four compounds ranged from 3.0% to 9.9% while the between-day precision varied from 3.6% to 14%. This method was used to analyze rat plasma samples after administration of COC alone and in combination with alcohol. The pharmacokinetic profiles of COC and its metabolites in these rats are also described.  相似文献   

11.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

12.
A simple and sensitive gas chromatographic method has been developed for the determination of timolol in plasma using electron-capture detection and propranolol as internal standard. Timolol was extracted using butyl chloride and derivatized using trifluoroacetic anhydride in butyl acetate. The lower detection limit for the assay was found to be 1 ng/ml from 1 ml of plasma. Extracted standards gave within-day precision of 12.55, 9.68 and 3.78% for 1, 20 and 100 ng/ml plasma samples, respectively. A recovery of at least 80% of timolol was found using the extraction method described. The assay was used in a randomized cross-over bioequivalence trial using an oral administration of 20 mg of timolol. Pharmacokinetic parameters compare favourably with other literature values.  相似文献   

13.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

14.
The analysis of arildone in plasma, urine and feces by gas—liquid chromatography with electron-capture detection is described. O-(2,3,4,5,6-Pentafluorohenzyl)hydroxylamine is the derivatizing agent for the plasma and urine analysis; 3-nitrophenylhydrazine is utilized for fecal analysis. The mean (± S.E.) minimum quantifiable level of arildone was 1.4 (± 0.2) ng/ml in urine, 6.4 (± 0.1) ng/ml in plasma, and 12.6 (± 1.0) ng/g in feces. The chromatographic response was linear in the range of 0 and 10–120 ng/ml for plasma, 0 and 2.5–20 ng/ml for urine and 0 and 25–250 ng/g for feces. The estimated overall precision of the assay was 5.5%, 6.4% and 8.9% in urine, plasma and feces, respectively.  相似文献   

15.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

16.
A high-performance liquid chromatographic method for the determination of bufaralol, a benzofuran analogue, in plasma is described.The unchanged drug, the major metabolites and an internal standard are extracted from plasma, purified by back-extraction steps and thereafter separated using a reversed-phase liquid chromatographic system. The detection is carried out by means of a fluorescence detector and an UV detector connected in series. The sensitivity of the assay for the unchanged drug and the major metabolite is about 1 ng/ml plasma using a 0.5 ml specimen per analysis and the relative standard deviation of the whole assay lies in the range ± 4–5%.The procedure was successfully used to determine plasma levels in volunteers following a single oral dose of 40 mg of bufaralol. The results obtained using the new high-performance liquid chromatographic method were compared with those determined by another method which combines gas chromatography with mass fragmentography, and it was found that these two sets of results coincided quite well.  相似文献   

17.
18.
An assay is described which detects saxitoxin (STX) and tetrodotoxin (TTX) by their competitive displacement of [3H]saxitoxin from its receptor in rat brain membranes. The assay has a sensitivity of 0.15 ng STX/ml and 0.8 ng TTX/ml for buffer samples. The assay was also applied to detection of these toxins in unextracted human plasma and found to have a sensitivity of 0.5 ng STX/ml and 0.6 ng TTX/ml. The competitive displacement assay appears to be the most sensitive procedure yet for detection of STX and TTX.  相似文献   

19.
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in plasma was developed. An Applied Biosystems API 3000 triple quadrupole mass spectrometer set to multiple reaction monitoring (MRM) mode, using atmospheric pressure photospray ionisation (APPI) in the positive mode. Using 17-alpha-methyltestosterone as internal standard (IS), liquid-liquid extraction was followed by reversed phase liquid chromatography using a phenyl-hexyl column and tandem mass spectrometric detection. The mean recovery for levonorgestrel and 17-alpha-methyltestosterone was 99.5 and 62.9%, respectively. The method was validated from 0.265 to 130 ng levonorgestrel/ml plasma with the lower limit of quantification (LLOQ) set at 0.265 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric (MS/MS) detection, allowing for a rapid (extraction and chromatography) and selective method for the determination of levonorgestrel in human plasma. The assay method was used in a pharmacokinetic study to quantify levonorgestrel in human plasma samples generated after administrating a single oral dose of 1.5 mg levonorgestrel to healthy female volunteers for up to five half lives. The total chromatographic runtime of this method was 5.0 min per sample, allowing for analysis of a large number of samples per batch.  相似文献   

20.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10-μm μBondapak phenyl column with an eluting solvent of water—methanol—1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(d-(-)-α-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 ± 6.3% (S.D.) in the concentration ranges of 0.1–20 μg per 0.2 ml of plasma with a limit of detection equivalent to 0.5 μg/ml plasma. The urine assay was validated over a concentration range of 0.025–5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 μg/ml) using a 0.1-ml urine specimen per assay.The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号