首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
After measuring toluene adsorption (15.7 mg-toluene/g-material), water holding capacity (18.5%), organic content (53.8%), specific surface area (18.1 m2/g-material), and microbial attachment, crab shells were chosen as the main packing material for a biofilter design. The crab shells, cheap and abundant in the Gangneung area, also have relatively rigid structure, low density, and ability to neutralize acids generated during mineralization of toluene. Since towel scraps have water holding capacity as high as 301.2%, 10% of the total packing was supplemented with them to compensate for low water holding capacity of the crab shells. The biofilter fed with defined chemical medium under 0.8∼1.3 mg/L of inlet toluene concentration and 18 seconds of residence time showed satisfactory removal efficiency of over 97% and 72.8 g/h·m3 of removal capacity. For the purpose of deceasing operation costs, leaf mold solution was tried as an alternative nutrient instead of a defined chemical medium. The removal efficiency and removal capacity were 85% and 56.3 g/h·m3, respectively, using the same inlet toluene concentration and residence time. This research shows the possibility of recycling crab shell waste as packing material for biofilter. In addition, leaf mold was able to serve as an alternative nutrient, which remarkably decreased the operating cost of the biofilter.  相似文献   

2.
Elimination capacity (EC) is frequently used as a performance and design criterion for vapor-phase biofilters without further verification of the microbial quantity and activity. This study was conducted to investigate how biofilters respond to high pollutant loadings and ultimately how this affects the EC of the biofilter. Two identical laboratory-scale biofilters were maintained at an initial toluene loading rate of 46 g m−3 h−1 for a period of 24 days. After the initial biofilm development stage, the loading rates were increased to 91 g m−3 h−1 and 137 g m−3 h−1, respectively. Following a short period of pseudo-steady state, toluene removal efficiencies rapidly declined in both biofilters, with a concurrent decline in both critical and maximum ECs. The decline was mainly due to deterioration in the biodegradation activity of the biofilm and a decline in the toluene-degrading bacterial population within the biofilm phase. The findings imply that high toluene loadings accelerated the deterioration in overall performance due to a rapid accumulation of inactive biomass. As a result, care must be used when relying on EC values for biofilter design and operational purposes, since the values do not appropriately reflect the temporal changes in biodegradation activity and active biomass quantities that can occur in biofilters subjected to high inlet loadings.  相似文献   

3.
A two-phase partitioning bioreactor (TPPB) achievedsimultaneous and continuous removal and degradation of benzene and toluene froman air stream. The aqueous-organic system utilized n-hexadecane as the organicphase, and the organism Alcaligenes xylosoxidans Y234 in the aqueous phaseto achieve the degradation of benzene and toluene. The system, which operates asa well-mixed dispersion and is therefore resistant to substrate surges, was firstshown to be capable of utilizing toluene while operating at a loading capacity of 235 g m-3 h-1with an elimination capacity of 233 g m-3 h-1. It was also determined that to characterize TPPB performance in terms of elimination capacity thedefinition of elimination capacity must be extended to include the cell mass present, a readilycontrollable variable given the nature of the system. Based on this criterion, it wasestimated that for a cell concentration of 1 g l-1 present in the TPPB, thepotential maximum toluene elimination capacity is 1290 g m-3 h-1 whichis substantially higher than any toluene elimination capacity achieved by biofiltersat a high removal efficiency. If no other factor were to limit the system, eliminationcapacities could be many times higher still, and are dependent on maintaining desiredcell concentrations above 1 g l-1. The TPPB was then operated at nominalloading capacities of 63 g m-3h-1 (benzene) and 51 g m-3 h-1 (toluene) at a removal efficiency greater than 99% to demonstratedthe applicability of this system in dealing with two chemical species simultaneously. TPPBsystems therefore have been shown to be effective at removing gaseous organiccontaminants at high removal efficiencies while also possessing desirable operatingfeatures, such as providing and maintaining high cell concentrations throughout thereactor, and a capacity to effectively deal with high contaminant loadings.  相似文献   

4.
BTEX catabolism interactions in a toluene-acclimatized biofilter   总被引:1,自引:0,他引:1  
BTEX substrate interactions for a toluene-acclimatized biofilter consortium were investigated. Benzene, ethylbenzene, o-xylene, m-xylene and p-xylene removal efficiencies were determined at a loading rate of 18.07 g m−3 h−1 and retention times of 0.5–3.0 min. This was also repeated for toluene in a 1:1 (m/m) ratio mixture (toluene: benzene, ethylbenzene, or xylene ) with each of the other compounds individually to obtain a final total loading of 18.07 g m−3 h−1. The results obtained were modelled using Michaelis–Menten kinetics and an explicit finite difference scheme to generate v max and K m parameters. The v max/K m ratio (a measure of the catalytic efficiency, or biodegradation capacity, of the reactor) was used to quantify substrate interactions occurring within the biofilter reactor without the need for free-cell suspended and monoculture experimentation. Toluene was found to enhance the catalytic efficiency of the reactor for p-xylene, while catabolism of all the other compounds was inhibited competitively by the presence of toluene. The toluene-acclimatized biofilter was also able to degrade all of the other BTEX compounds, even in the absence of toluene. The catalytic efficiency of the reactor for compounds other than toluene was in the order: ethylbenzene>benzene>o-xylene>m-xylene>p-xylene. The catalytic efficiency for toluene was reduced by the presence of all other tested BTEX compounds, with the greatest inhibitory effect being caused by the presence of benzene, while o-xylene and p-xylene caused the least inhibitory effect. This work illustrated that substrate interactions can be determined directly from biofilter reactor results without the need for free-cell and monoculture experimentation. Received: 13 April 2000 / Received revision: 20 July 2000 / Accepted: 27 July 2000  相似文献   

5.
An innovative, coir-pith-based, filter bed for degrading vapor phase toluene in a gas biofilter over 160 days without any external nutrient supply is reported in this study. Indigenous microflora present in the coir pith as well as in the aerobic sludge added at the start-up stage metabolized the toluene, and correspondingly, CO2 was produced in the biofilter. Inlet toluene concentration in the range of 0.75 to 2.63 g/m3 was supplied to the biofilter in short acclimation periods. The maximum elimination capacity achieved was 96.75 g/m3·h at 120.72 g/m3·h loading where around 60% was recovered as CO2. The filter bed maintained a stable low-pressure drop (0–4 mm H2O), neutral pH range (6.5–7.5), and moisture content of 60–80% (w/w) throughout the period. In addition to toluene-degrading microbial community, a grazing fauna including rotifer, bacteriovoric nematode, tardigrade, and fly larvae were also present in the filter bed. The overall performance of the biofilter bed in pollutant removal and sustainability was analyzed in this study.  相似文献   

6.
Two biofilters fed toluene-polluted air were inoculated with new fungal isolates of either Exophiala oligosperma or Paecilomyces variotii, while a third bioreactor was inoculated with a defined consortium composed of both fungi and a co-culture of a Pseudomonas strain and a Bacillus strain. Elimination capacities of 77 g m–3 h–1 and 55 g m–3 h–1 were reached in the fungal biofilters (with removal efficiencies exceeding 99%) in the case of, respectively, E. oligosperma and Paecilomyces variotii when feeding air with a relative humidity (RH) of 85%. The inoculated fungal strains remained the single dominant populations throughout the experiment. Conversely, in the biofilter inoculated with the bacterial–fungal consortium, the bacteria were gradually overgrown by the fungi, reaching a maximum elimination capacity around 77 g m–3 h–1. Determination of carbon dioxide concentrations both in batch assays and in biofiltration studies suggested the near complete mineralization of toluene. The non-linear toluene removal along the height of the biofilters resulted in local elimination capacities of up to 170 g m–3 h–1 and 94 g m–3 h–1 in the reactors inoculated, respectively, with E. oligosperma and P. variotii. Further studies with the most efficient strain, E. oligosperma, showed that the performance was highly dependent on the RH of the air and the pH of the nutrient solution. At a constant 85% RH, the maximum elimination capacity either dropped to 48.7 g m–3 h–1 or increased to 95.6 g m–3 h–1, respectively, when modifying the pH of the nutrient solution from 5.9 to either 4.5 or 7.5. The optimal conditions were 100% RH and pH 7.5, which allowed a maximum elimination capacity of 164.4 g m–3 h–1 under steady-state conditions, with near-complete toluene degradation.  相似文献   

7.
Toluene and acetone mixtures are commonly encountered from the manufacture of semi-conductor or opto-electronic apparatus. This study attempts to employ a trickle-bed air biofilter (TBAB) for treating toluene and acetone mixtures under different gas flow rates and influent concentrations. In the pseudo-steady-states, the elimination capacities of toluene and acetone increased but the removal efficiencies decreased with the increase of influent carbon loading. The removal efficiencies of toluene were higher than those of acetone, indicating that toluene is a preferred substrate in the mixtures. Greater than 90% removal efficiencies were achieved with influent carbon loadings of toluene and acetone below 125 and 15 g/m3 h, respectively. The TBAB appears efficient for controlling toluene and acetone mixture with medium toluene and low acetone loadings. Applicable operating conditions of TBAB for treating mixed toluene and acetone emission are suggested.  相似文献   

8.
Toluene vapour removal in a laboratory-scale biofilter   总被引:4,自引:0,他引:4  
A bench-scale biofilter with a 0.5-m high filter bed, inoculated with a toluene-degrading strain of Acinetobacter sp. NCIMB 9689, was used to study toluene removal from a synthetic waste air stream. Different sets of continuous tests were conducted at influent toluene concentrations ranging over 0.1–4.0 g m−3 and at superficial gas velocities ranging over 17.8–255 m h−1. The maximum volumetric toluene removal rate for the biofilter (242 g m−3 h−1) was obtained at a superficial gas velocity of 127.5 m h−1 (corresponding to a residence time of 28 s) and a toluene inlet concentration of 4.0 g m−3. Under these operating conditions, toluene removal efficiency was only 0.238, which suggested that effective operation required higher residence times. Removal efficiencies higher than 0.9 were achieved at organic loads less than 113.7 g m−3 h−1. A macro-kinetic study, performed using concentration profiles along the bioreactor, revealed this process was limited by diffusion at organic loads less than 100 g m−3 h−1 and by biological reaction beyond this threshold. Received: 10 October 1999 / Received revision: 15 February 2000 / Accepted: 18 February 2000  相似文献   

9.
Packing materials play a key role in waste gas treatment. Organic and inert packing materials have their disadvantages, which may be minimized by mixed packing. In this study, various operating conditions were applied to evaluate the performance of structured mixed packing and inert packing materials in toluene biotricklefiltration. Four biotrickle filters were packed with structured mixed packing materials, namely, ceramic pall rings, ceramic rashig rings, and lava rock. Their toluene removal capacity was studied for 217 day using a laboratory-scale reaction under various operating conditions. The key elimination capacity (removal efficiency > 95%) ranking of the biotrickle filters was as follows: Structured mixed packing (306.20 ± 7.90 g/m3/h) > pall ring (156.71 ± 7.84 g/m3/h) > rashig ring (153.31 ± 6.14 g/m3/h) > lava rock (150.32 ± 9.19 g/m3/h). The structured mixed packing and inert packing resulted in excellent toluene-degrading biofilter performance under long-term operation. The structured mixed packing provided a more rapid startup rate and better process robustness than the inert packing did. The biotrickle filter with mixed packing materials had a high elimination capacity which makes it suitable for various real-life applications, whereas the capability of the inert packing material was more suitable for treating a steady low toluene load.  相似文献   

10.
Benzene, toluene, ethylbenzene and xylene (BTEX) substrate interactions for a mesophilic (25°C) and thermophilic (50°C) toluene-acclimatized composted pine bark biofilter were investigated. Toluene, benzene, ethylbenzene, o-xylene, m-xylene and p-xylene removal efficiencies, both individually and in paired mixtures with toluene (1:1 ratio), were determined at a total loading rate of 18.1 g m–3 h–1 and retention time ranges of 0.5–3.0 min and 0.6–3.8 min for mesophilic and thermophilic biofilters, respectively. Overall, toluene degradation rates under mesophilic conditions were superior to degradation rates of individual BEX compounds. With the exception of p-xylene, higher removal efficiencies were achieved for individual BEX compounds compared to toluene under thermophilic conditions. Overall BEX compound degradation under mesophilic conditions was ranked as ethylbenzene >benzene >o-xylene >m-xylene >p-xylene. Under thermophilic conditions overall BEX compound degradation was ranked as benzene >o-xylene >ethylbenzene >m-xylene >p-xylene. With the exception of o-xylene, the presence of toluene in paired mixtures with BEX compounds resulted in enhanced removal efficiencies of BEX compounds, under both mesophilic and thermophilic conditions. A substrate interaction index was calculated to compare removal efficiencies at a retention time of 0.8 min (50 s). A reduction in toluene removal efficiencies (negative interaction) in the presence of individual BEX compounds was observed under mesophilic conditions, while enhanced toluene removal efficiency was achieved in the presence of other BEX compounds, with the exception of p-xylene under thermophilic conditions.  相似文献   

11.
Pseudomonas sp. SR-5 was isolated as a styrene-degrading bacterium. In liquid culture containing 1% (v/v) styrene, more than 90% styrene was degraded in 53 h and the doubling time of SR-5 was 2 h. The removal of styrene gas was investigated in biofilters for 31 days using an organic packing material of peat and an inorganic packing material of ceramic inoculated with SR-5. The maximum-styrene-elimination capacities for peat and ceramic packing materials were 236 and 81 g m–3 h–1, respectively. The percentage of styrene converted to low molecular weight compounds including CO2 in the peat and ceramic biofilters during a 10-day operation were estimated to be 90.4 and 36.7%, respectively. As the pressure drop in the peat bioflter at the end of experiment was significantly higher than that in ceramic biofilter, a biofilter using a mixture of peat and ceramic was tested. We determined that the maximum elimination capacity was 170 g m–3 h–1 and the production of low molecular weight compounds was 95% at a low pressure drop for this mixed packing material filter.  相似文献   

12.
In the present study, toluene elimination in the polyurethane (PU) biofilter during long-term (145 day) operation was characterized, and assessed the effects of changing the inlet loading and space velocity (SV). A very high elimination capacity of 3.7 kg·m−3·h−1 was obtained at an inlet loading of 4.0 kg·m–3·h−1 (inlet toluene concentration of 900 ppmv at a SV of 1,040 h−1). Backwashing with irrigation and compressed air allowed maintenance of a pressure drop of < 80 mm H2O·m−1-filter at an SV of 830 h−1 and an elimination efficiency of > 90% during the 145 day of operation. In conclusion, the PU biofilter can overcome the problems of clogging caused by excess biomass growth and of low treatment capacities of conventional biofilters.  相似文献   

13.
A bacterial consortium with complementary metabolic capabilities was formulated and specific removal rates were 0.14, 0.35, 0.04, and 0.39 h–1 for benzene, toluene, o-xylene, and m,p-xylene, respectively. When immobilized on a porous peat moss biofilter, removal of all five (= BTX) components was observed with rates of 1.8–15.4 g m–3 filter bed h–1. Elimination capacities with respect to the inlet gas concentrations of BTX and airflow rates showed diffusive regimes in the tested concentration range of (0.1–5.3 g m–3) and airflow (0.55–1.82 m3 m–2 h–1) except for o-xylene which reached its critical gas concentration at 0.3 g m–3.  相似文献   

14.
The composite filler micro-embedded with Pseudomonas putida (P. putida) was prepared and the biodegradation performance of the filler was evaluated in a biofilter. Five phases were set up to evaluate the performance of the biofilter under different toluene inlet loadings and transient shock loadings. In particular, the microbial community structure in the biofilms and fillers was measured by sequence analysis of the 16S rRNA gene. The results show that the biofilter packed with the composite fillers was suitable for the biodegradation of toluene. The biofilter could start up quickly with high removal efficiency (RE), and remain above 90 % RE when the empty bed residence time (EBRT) was 18 s and the inlet loading rates were not higher than 41.4 g/(m3·h). Moreover, the biofilter could tolerate substantial transient shock loadings. The high removal efficiency and elimination capacity contributed to rich bacterial communities for the efficient degradation of toluene. The dominant microbial communities at the phylum level were mainly Firmicutes, Actinobacteria and Proteobacteria. It is noteworthy that the abundance of Bacteroidetes at phylum level and Chungangia and Stenotrophomonas at genus level increased significantly during the re-start period.  相似文献   

15.
Removal of toluene in waste gases using a biological trickling filter   总被引:12,自引:0,他引:12  
The removal of toluene from waste gas was studied in a trickling biofilter. A high level of water recirculation (4.7 m h–1) was maintained in order to keep the liquid phase concentration constant and to achieve a high degree of wetting. For loads in the range from 6 to 150 g m–3 h–1 the maximum volumetric removal rate (elimination capacity) was 35±10 g m–3 h–1, corresponding to a zero order removal rate of 0.11±0.03 g m–2 h–1 per unit of nominal surface area. The surface removal was zero order above the liquid phase concentrations of approximately 1.0 g m–3, corresponding to inlet gas concentrations above 0.7–0.8 g m–3. Below this concentration the surface removal was roughly of first order. The magnitude of the first order surface removal rate constant, k1A , was estimated to be 0.08–0.27 m h–1 (k1A a=24–86 h–1). Near-equilibrium conditions existed in the gas effluent, so mass transfer from gas to liquid was obviously relatively fast compared to the biological degradation. An analytical model based on a constant liquid phase concentration through the trickling filter column predicts the effluent gas concentration and the liquid phase concentration for a first and a zero order surface removal. The experimental results were in reasonable agreement with a very simple model valid for conditions with an overall removal governed by the biological degradation and independent of the gas/liquid mass transfer. The overall liquid mass transfer coefficient, KLa, was found to be a factor 6 higher in the system with biofilm compared to the system without. The difference may be explained by: 1. Difference in the wetting of the packing material, 2. Mass transfer occurring directly from the gas phase to the biofilm, and 3. Enlarged contact area between the gas phase and the biofilm due to a rough biofilm surface.  相似文献   

16.
Interactions of toluene and p-xylene in air treatment biofilters packed with an inert filter media were studied. The effect of the inlet load of toluene, p-xylene and mixtures of both compounds on the biodegradation rate was analyzed in three lab-scale biofilters. A maximum elimination capacity (EC) of 26.5 and 40.3 g C m−3 h−1 for an inlet load (IL) of 65.6 and 57.8 g C m−3 h−1 was obtained for p-xylene and toluene biofilters, respectively. Inhibition of p-xylene biodegradation by the presence of toluene took place when the mixture was treated, whereas the presence of p-xylene had an enhancing effect on the toluene removal efficiency. Specific growth rates (μ) from 0.019 to 0.068 h−1 were calculated in the mixed biofilter, where the highest values were similar to mixtures with lower p-xylene levels (ILp-Xyl 8.84 ± 0.29 g C m−3 h−1). Michaelis-Menten and Haldane type models were fitted to experimental EC for p-xylene and toluene biofilters, respectively.  相似文献   

17.
In this work, the influence of toluene gas concentration on the isolation of toluene degrading microbial communities from activated sludge was studied. Toluene biodegradation at gas phase concentration of 10?g?m?3 (R1) resulted in process instability with removal efficiencies (RE) lesser than 33?%, while operation at toluene gas phase concentrations of 300?mg?m?3 (R2) and 11?mg?m?3 (R3) was stable with RE ranging from 74 to 94?%. The consortium isolated in R1 exhibited the highest tolerance toward toluene but the lowest biodegradation performance at trace level VOC concentrations. Despite R2 and R3 showed a similar sensitivity toward toluene toxicity, the microbial community from R2 supported the most efficient toluene biodegradation at trace level VOC concentrations. The Shannon-Wiener index showed an initial biodiversity decrease from 3.2 to 2.0, 1.9 and 2.7 in R1, R2 and R3, respectively. However, while R2 and R3 were able to recover their initial diversity levels by day 48, this loss in diversity was permanent in R1. These results showed that traditional inoculum isolation/acclimation techniques based on the exposure of the inoculum to high VOC concentrations, where toxicity tolerance plays a key role, may result in a poor abatement performance when the off-gas stream is diluted.  相似文献   

18.
The removal of a 1:1 by weight mixture of ethanol and ethyl acetate was studied in a gas phase biotrickling filter running under conditions that simulated industrial emissions from the flexographic sector, i.e. discontinuous loading (twelve hours per day and five days per week) and oscillating concentration of the inlet stream. Three sets of experimental conditions were tested in which empty‐bed residence time varied from 60 to 25 s (inlet loads from 50 to 90 g C m?3 h?1). The biotrickling filter reached a maximum elimination capacity of 48.5 g C m?3 h?1 (removal efficiency=68.9%) for an empty‐bed residence time of 40 s. A decrease in the residence time from 40 to 25 s adversely affected the elimination capacity (40.3 g C m?3 h?1, removal efficiency=46.6%). For the three tested residence times, outlet concentrations during pollutant feeding were above 100 mg C m?3 (EU legal limit for flexographic facilities). Then an activated carbon prefilter was installed to buffer the fluctuating concentration, enabling a more stable operation. The desorbed pollutant from the activated carbon during non‐feeding hours also served as an extra source of substrate, avoiding severe starvation. The use of the activated carbon prefilter with a volume 25 times lower than that of the bioreactor was shown to reach an average outlet emission concentration lower than 50 mg C m?3 operating the biotrickling filter at an empty‐bed residence time of 40 s, with a maximum elimination capacity of 59.6 g C m?3 h?1 (removal efficiency=92.0%).  相似文献   

19.
Active compost biofiltration of toluene   总被引:5,自引:0,他引:5  
Composting of leaves and alfalfa (i.e. active compost) was used for thebiofiltration of toluene-contaminated air in a 6-L biofilter (initial bedheight: 180 mm). During the thermophilic phase (45 to 55 °C), toluenebiodegradation rates reached 110 gtoluene.m-3.h-1 at an inlet concentration ofabout 5 g.m-3.h-1 and a gas residence time of 90 seconds. Thehighest rates were obtained late in the thermophilic phase suggesting amicrobial adaptation was occurring. Biodegradation rates decreased rapidly(50% in 48h) in the cooling stage. Under mesophilic conditions, themaximum biodegradation rates that could be obtained by increasing the inlettoluene concentration were near 89 gtoluene.m-3.h-1 which issimilar to that reported in the literature for mature compost biofilters. Novolatile by-product was detected by gas chromatography. Mineralization of14C-toluene and benzene showed that they were completelydegraded into CO2 and H2O under boththermophilic and mesophilic conditions. Bacteria isolated from latemesophilic stage had the capacity to degrade all BTEX compounds but were notable to transform chlorinated compounds. No organisms were isolated whichcould use toluene as their sole source of carbon and energy at 50 °C.Active compost biofiltration should be an excellent process for thetreatment of gaseous BTEX by biofiltration. This is the first report ofthermophilic biofiltration of toluene.  相似文献   

20.
Air artificially contaminated with increasing concentrations of benzene was treated in a laboratory scale compost-packed biofilter for 240 days with a removal efficiency of 81–100%. The bacterial community in the packing material (PM) at different heights of the biofilter was analysed every 60 days. Bacterial plate counts and ribosomal intergenic spacer analysis (RISA) of the isolated strains showed that the number of cultivable aerobic heterotrophic bacteria and the species diversity increased with benzene availability. Identification of the isolated species and the main bands in denaturing gradient gel electrophoresis (DGGE) profiles from total compost DNA during the treatment revealed that, at a relatively low volumetric benzene load (1.2≤VBL≤6.4 g m−3 PM h−1), besides low G+C Gram positive bacteria, originally present in the packing compost, bacteroidetes and β- and γ-proteobacteria became detectable in the colonising population. At the VBL value (24.8 g m−3 PM h−1) ensuring the maximum elimination capacity of the biofilter (20.1 g m−3 PM h−1), strains affiliated to the genus Rhodococcus dominated the microflora, followed by β-proteobacteria comprising the genera Bordetella and Neisseria. Under these conditions, more than 35% of the isolated strains were able to grow on benzene as the sole carbon source. Comparison of DGGE and automated RISA profiles of the total community and isolated strains showed that a complex bacterial succession occurred in the reactor in response to the increasing concentrations of the pollutant and that cultivable bacteria played a major role in benzene degradation under the adopted conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号