首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The identification tests for adsorbed diphtheria, tetanus and pertussis vaccines, which are required by the European Pharmacopoeia to be undertaken in animals, may be replaced by precipitation tests, for instance in agaros gels. Such in vitro tests eliminate the use of animals and are less expensive and time-consuming. The single radial immunodiffusion technique is a suitable semiquantitative test, while the double diffusion test is necessary for the investigation of complete or partial identity. The precipitates obtained in the single radial diffusion tests and in double diffusion tests with diphtheria toxoid were visible without staining; those obtained in the double diffusion tests with tetanus toxoid were weaker and staining was sometimes needed.  相似文献   

2.
3.
J Lyng 《Biologicals》1990,18(1):11-17
The Lf-unit, which is used in the control of diphtheria and tetanus toxoid production and in some countries also to follow immunization of horses for production of antitoxins, has hitherto been defined by means of antitoxin preparations. A diphtheria toxoid and a tetanus toxoid preparation, both freeze-dried, were examined in an international collaborative study for their suitability to serve as reference reagents in the flocculation tests and for defining the Lf-units. It was shown that flocculation tests using the reference toxoids are very reproducible and reliable and the WHO Expert Committee on Biological Standardization established: the toxoid called DIFT as the International Reference Reagent of Diphtheria Toxoid for Flocculation Test with a defined content of 900 Lf-units of diphtheria toxoid per ampoule; and the toxoid called TEFT as the International Reference Reagent of Tetanus Toxoid for Flocculation Test with a defined content of 1000 Lf-units of diphtheria toxoid per ampoule.  相似文献   

4.
DPT, a combination vaccine against diphtheria, tetanus and pertussis is available since many years and still continued in the national immunisation schedule of many countries. Although highly potent, reactions to DPT vaccine are well known, mainly attributed to the factors like Pertussis component, aluminum adjuvant and lower purity of tetanus and diphtheria toxoids. The latter most important aspect has become a matter of concern, specially for the preparation of next generation combination vaccines with more number of antigens in combination with DPT.Purity of toxoid is expressed as Lf (Limes flocculation) per mg of protein nitrogen. The Kjeldahl method (KM) of protein nitrogen estimation suggested by WHO and British Pharmacopoeia is time consuming and less specific. Need has been felt to explore an alternative method which is quick and more specific for toxoid protein determination. DC (detergent compatible) protein assay, an improved Lowry's method, has been found to be much more advantageous than Kjeldahl method.  相似文献   

5.
M Huet  E Relyveld  S Camps 《Biologicals》1990,18(1):61-67
The authors have developed a simplified activity test for Tetanus Toxoids Adsorbed, based on the comparison of antitoxin levels in mice 4 weeks after injection of a reference toxoid and of the vaccine to be tested. Titration of tetanus antitoxin is achieved by passive agglutination of turkey RBC sensitized by means of glutaraldehyde. After preliminary experiments establishing feasibility of this method, the authors have obtained reproducible and quantitative results. They observed an increase of the immune response by a booster and an immunostimulation when pertussis component is present. They have found close correlation in immunized mice between the titre of circulating antibodies and the survival/death response after challenge by tetanus toxin as done in the official control. This simplified method using a reduced number of animals, yields, nevertheless, quantified results with confidence limits. Thus it is suitable for laying down a norm and can in many cases take the place of the official potency test which is tedious, expensive and often criticized.  相似文献   

6.
The aim of this study is to develop the previous research on tetanus toxoid and improve the level of antibodies against tetanus and diphtheria toxoids using liposomes as adjuvant. The results show that negatively charged liposomes enhance the immune effects of the combination of the two vaccines.  相似文献   

7.
8.
9.
10.
A direct system for screening large numbers of staphylococcal isolates for enterotoxin production has been developed. The system employs polyvalent (serotypes A, B, C, D, and E) immunodiffusion assay slides in conjunction with a multiple-culturing system for toxin production. With the combined system, as many as 50 cultures can be screened simultaneously on a single assay slide having a sensitivity of about 0.3 microgram/ml. The system should be useful for detecting potential enterotoxin in foods containing a predominance of non-enterotoxigenic strains.  相似文献   

11.
12.
The 1st International Reference Reagents (IRR) of Diphtheria and Tetanus Toxoids for Flocculation Test (DIFT and TEFT) were established by the WHO in 1988. These reagents are essential for the standardization of assays used to calculate Lf units of toxoids. Candidate replacement materials were provided by several European vaccine manufacturers and were formulated and freeze-dried at NIBSC. This paper provides a summary of the results of an international collaborative study including 18 laboratories from 16 countries, which examined the candidate replacement materials in a variety of methods. Materials 02/176 and 04/150 were proposed and adopted by the Expert Committee on Biological Standardization of WHO in October 2007 as 2nd WHO International Standards of Diphtheria and Tetanus Toxoid for use in Flocculation Test. The replacement standards were assigned the value of 1100 and 690Lf/ampoule, respectively, based on results of flocculation tests carried out using provided reagents. Material coded 02/176 fully complied with the WHO specifications for stability, residual moisture content, precision of fill and sterility. Stability of material coded 04/150 was slightly lower than expected but predictions were based only on 2-year data and were to be further monitored, post-adoption.  相似文献   

13.
14.
15.
Immune responses of 11 mouse strains with known genetical characteristics and two outbred strains to diphtheria and to tetanus toxoids were compared. Both diphtheria and tetanus antitoxins were titrated by passive hemagglutination. From the pattern of the immune response, the mouse strains tested may be classified into four groups. [1] Strains ddY (SPF) and ddY (conv) and those with haplotype H-2b, such as C57BL/6 and C57BL/10, were high responders to both toxoids. [2] Strains with H-2d, such as BALB/c, B10.D2 and DBA/2Cr, were intermediate responders to both toxoids. [3] Strains with H-2k, H-2a or, H-2m, such as C3H/He, B10.BR, B10.BR/SgSn, B10.A/SgSnJ and B10.AKM/O1a, were high responders to diphtheria toxoid but low responders to tetanus toxoid. [4] The strain with H-2h4, B10.A (4R), was a poor responder to both toxoids.  相似文献   

16.
17.
18.
The development of acellular pertussis vaccines has raised a number of issues relevant to the control of these products. Of particular importance is the need for robust and accurate in vitro assays for the antigen content of the vaccines which might contain up to five different antigen components, each of which needs to be independently assayed. This paper describes a simple method for the quantification of three component antigens. Because relatively high doses of purified antigens are used in those preparations, the elimination of residual toxicity is a major concern. This is achieved by genetic modification of chemical treatment. The latter results in modification of the immunological reactivity of the antigens making direct assay by such methods as ELISA ineffective. A single radial diffusion technique using polyclonal antisera for the assay of pertussis toxoid (PTxd), chemically treated filamentous haemagglutinin (FHA) and pertactin (69 kDa) has been developed. The method uses low concentrations of antisera, allowing accurate and reproducible quantification of antigen content as low as 25 microg/ml of protein for pertussis toxoid and filamentous haemagglutinin and 5 microg/ml for pertactin. Since by the addition of detergent, diffusible subunits are produced irrespective of the original physical state of the antigens, the assay is suitable for assay of these antigens after detoxification/or stabilization by chemical treatment and is able to determine the differences between preparations which have the same protein concentration but different antigenic contents. This provides a means for assuring the consistency of the antigens after detoxification/or chemical stabilization which could be used as an in-process control method for acellular pertussis vaccines.  相似文献   

19.
Considerable confusion exist in the quantitative estimation of diphtheria and tetanus toxoids. The present paper is the first in a series of papers comparing various quantitative methods. It describes the flocculation test, gives a mathematical model for the three-dimensional reaction surface, and suggests different designs which facilitate the unbiased calculation of the end-point.  相似文献   

20.
Two freeze-dried international reference tetanus toxoids of different origin and purified by different methods were compared in various potency assay systems, in vitro as well as in vivo. When the antigenic contents in the two toxoids are used as the basis for expressing the relative potency, different tests in animals gave different potencies. It is concluded that, as a result of such differences, tetanus vaccines can hardly be quantitated unambiguously in potency assays in animals. Since, however, a biological immunogenicity control seems necessary, a more simple type of test is suggested, which will require much less resources in terms of animals and manpower.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号