首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High throughput screening (HTS) of chromatography resins can accelerate downstream process development by rapidly providing information on product and impurity partitioning over a wide range of experimental conditions. In addition to the removal of typical product and process‐related impurities, chromatography steps are also used to remove potential adventitious viral contaminants and non‐infectious retrovirus‐like particles expressed by rodent cell lines used for production. This article evaluates the feasibility of using HTS in a 96‐well batch‐binding format to study removal of the model retrovirus xenotropic murine leukemia virus (xMuLV) from product streams. Two resins were examined: the anion exchange resin Q Sepharose Fast Flow? (QSFF) and Capto adhere?, a mixed mode resin. QSFF batch‐binding HTS data was generated using two mAbs at various pHs, NaCl concentrations, and levels of impurities. Comparison of HTS data to that generated using the column format showed good agreement with respect to virus retentation at different pHs, NaCl concentrations and impurity levels. Results indicate that NaCl concentration and impurity level, but not pH, are key parameters that can impact xMuLV binding to both resins. Binding of xMuLV to Capto adhere appeared to tolerate higher levels of NaCl and impurity than QSFF, and showed some product‐specific impact on binding that was not observed with QSFF. Overall, the results demonstrate that the 96‐well batch‐binding HTS technique can be an effective tool for rapidly defining conditions for robust virus clearance on chromatographic resins. Biotechnol. Bioeng. 2013; 110: 1984–1994. © 2013 Wiley Periodicals, Inc.  相似文献   

2.
The recently discovered contamination of oral rotavirus vaccines led to exposure of millions of infants to porcine circovirus (PCV). PCV was not detected by conventional virus screening tests. Regulatory agencies expect exclusion of adventitious viruses from biological products. Therefore, methods for inactivation/removal of viruses have to be implemented as an additional safety barrier whenever feasible. However, inactivation or removal of PCV is difficult. PCV is highly resistant to widely used physicochemical inactivation procedures. Circoviruses such as PCV are the smallest viruses known and are not expected to be effectively removed by currently‐used virus filters due to the small size of the circovirus particles. Anion exchange chromatography such as Q Sepharose® Fast Flow (QSFF) has been shown to effectively remove a range of viruses including parvoviruses. In this study, we investigated PCV1 removal by virus filtration and by QSFF chromatography. As expected, PCV1 could not be effectively removed by virus filtration. However, PCV1 could be effectively removed by QSFF as used during the purification of monoclonal antibodies (mAbs) and a log10 reduction value (LRV) of 4.12 was obtained. © 2013 American Institute of Chemical Engineers Biotechnol. Prog., 29:1464–1471, 2013  相似文献   

3.
Viral safety is a critical concern with regard to monoclonal antibody (mAb) products produced in mammalian cells such as Chinese hamster ovary cells. Manufacturers are required to ensure the safety of such products by validating the clearance of viruses in downstream purification steps. Cation exchange (CEX) chromatography is widely used in bind/elute mode as a polishing step in mAb purification. However, bind/elute modes require a large volume of expensive resin. To reduce the production cost, the use of CEX chromatography in overloaded mode has recently been investigated. The viral clearance ability in overloaded mode was evaluated using murine leukemia virus (MLV). Even under high-load conditions such as 2,000 g mAb/L resin, MLV was removed from mAb solutions. This viral clearance ability was not significantly affected by resin type or mAb type. The overloaded mode can also remove other types of viruses such as pseudorabies virus and reovirus Type 3 from mAb solutions. Based on these results, this cost-effective overloaded mode is comparable to the bind-elute mode in terms of viral removal.  相似文献   

4.
Viral safety is required for biological products to treat human diseases, and the burden of inactivation and or virus removal lies on the downstream purification process. Minute virus of mice (MVM) is a nonenveloped parvovirus commonly used as the worst-case model virus in validation studies because of its small size and high chemical stability. In this study, we investigated the use of MVM-mock virus particle (MVP) and bacteriophage ΦX174 as surrogates for MVM to mimic viral clearance studies, with a focus on chromatography operations. Based on structural models and comparison of log reduction value among MVM, MVP, and ΦX174, it was demonstrated that MVP can be used as a noninfectious surrogate to assess viral clearance during process development in multiple chromatography systems in a biosafety level one (BSL-1) laboratory. Protein A (ProA) chromatography was investigated to strategically assess the impact of the resin, impurities, and the monoclonal antibody product on virus removal.  相似文献   

5.
The potential of viral contamination is a regulatory concern for continuous cell line-derived pharmaceutical proteins. Complementary and redundant safety steps, including an evaluation of the viral clearance capacity of unit operations in the purification process, are performed prior to registration and marketing of biotechnology pharmaceuticals. Because process refinement is frequently beneficial, CBER/FDA has published guidance facilitating process improvement by delineating specific instances where the bracketing and generic approaches are appropriate for virus removal validation. In this study, a generic/matrix study was performed using Q-Sepharose Fast Flow (QSFF) chromatography to determine if bracketing and generic validation can be applied to anion exchange chromatography. Key operational parameters were varied to upper and lower extreme values and the impact on viral clearance was assessed using simian virus 40 (SV40) as the model virus. Operational ranges for key chromatography parameters were identified where an SV40 log(10) reduction value (LRV) of >or=4.7 log(10) is consistently achieved. On the basis of the apparent robustness of SV40 removal by Q-anion exchange chromatography, we propose that the concept of "bracketed generic" validation can be applied to this and potentially other chromatography unit operations.  相似文献   

6.
Chinese hamster ovary cells used for pharmaceutical protein production express noninfectious retrovirus-like particles. To assure the safety of pharmaceutical proteins, validation of the ability of manufacturing processes to clear retrovirus-like particles is required for product registration. Xenotropic murine leukemia virus (X-MuLV) is often used as a model virus for clearance studies. Traditionally, cell-based infectivity assay has been the standard virus quantification method. In this article, a real time quantitative PCR (Q-PCR) method has been developed for X-MuLV detection/quantification. This method provides accurate and reproducible quantification of X-MuLV particle RNA (pRNA) over a linear dynamic range of at least 100,000-fold with a quantification limit of approximately 1.5 pRNA copies microL(-1). It is about 100-fold more sensitive than the cell-based infectivity assay. High concentrations of protein and cellular DNA present in test samples have been demonstrated to have no impact on X-MuLV quantification. The X-MuLV clearance during chromatography and filtration procedures determined by this method is highly comparable with that determined by the cell-based infectivity assay. X-MuLV clearance measured by both methods showed that anion exchange chromatography (QSFF) and DV50 viral filtration are robust retroviral removal steps. In addition, combination of the two methods was able to distinguish the viral removal from inactivation by the Protein A chromatography, and fully recognize the viral clearance capacity of this step. This new method offers significant advantages over cell-based infectivity assays. It could be used to substitute cell-based infectivity assays for process validation of viral removal procedures, but not inactivation steps. Its availability should greatly facilitate and reduce the cost of viral clearance evaluations for new biologic product development.  相似文献   

7.
8.
The quality‐by‐design (QbD) regulatory initiative promotes the development of process design spaces describing the multidimensional effects and interactions of process variables on critical quality attributes of therapeutic products. However, because of the complex nature of production processes, strategies must be devised to provide for design space development with reasonable allocation of resources while maintaining highly dependable results. Here, we discuss strategies for the determination of design spaces for viral clearance by anion exchange chromatography (AEX) during purification of monoclonal antibodies. We developed a risk assessment for AEX using a formalized method and applying previous knowledge of the effects of certain variables and the mechanism of action for virus removal by this process. We then use design‐of‐experiments (DOE) concepts to perform a highly fractionated factorial experiment and show that varying many process parameters simultaneously over wide ranges does not affect the ability of the AEX process to remove endogenous retrovirus‐like particles from CHO‐cell derived feedstocks. Finally, we performed a full factorial design and observed that a high degree of viral clearance was obtained for three different model viruses when the most significant process parameters were varied over ranges relevant to typical manufacturing processes. These experiments indicate the robust nature of viral clearance by the AEX process as well as the design space where removal of viral impurities and contaminants can be assured. In addition, the concepts and methodology presented here provides a general approach for the development of design spaces to assure that quality of biotherapeutic products is maintained. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

9.
Anion‐exchange chromatography (AEX) is used in the downstream purification of monoclonal antibodies to remove impurities and potential viral contamination based on electrostatic interactions. Although the isoelectric point (pI) of viruses is considered a key factor predicting the virus adsorption to the resin, the precise molecular mechanisms involved remain unclear. To address this question, we compared structurally homologous parvoviruses that only differ in their surface charge distribution. A single charged amino acid substitution on the capsid surface of minute virus of mice (MVM) provoked an increased apparent pI (pIapp) 6.2 compared to wild‐type MVM (pIapp = 4.5), as determined by chromatofocusing. Despite their radically different pIapp, both viruses displayed the same interaction profile in Mono Q AEX at different pH conditions. In contrast, the closely related canine parvovirus (pIapp = 5.3) displayed a significantly different interaction at pH 5. The detailed structural analysis of the intricate three‐dimensional structure of the capsids suggests that the charge distribution is critical, and more relevant than the pI, in controlling the interaction of a virus with the chromatographic resin. This study contributes to a better understanding of the molecular mechanisms governing virus clearance by AEX, which is crucial to enable robust process design and maximize safety.  相似文献   

10.
The mammalian cell-lines used to produce biopharmaceutical products are known to produce endogenous retrovirus-like particles and have the potential to foster adventitious viruses as well. To ensure product safety and regulatory compliance, recovery processes must be capable of removing or inactivating any viral impurities or contaminants which may be present. Anion exchange chromatography (AEX) is a common process in the recovery of monoclonal antibody products and has been shown to be effective for viral removal. To further characterize the robustness of viral clearance by AEX with respect to process variations, we have investigated the ability of an AEX process to remove three model viruses using various combinations of mAb products, feedstock conductivities and compositions, equilibration buffers, and pooling criteria. Our data indicate that AEX provides complete or near-complete removal of all three model viruses over a wide range of process conditions, including those typically used in manufacturing processes. Furthermore, this process provides effective viral clearance for different mAb products, using a variety of feedstocks, equilibration buffers, and different pooling criteria. Viral clearance is observed to decrease when feedstocks with sufficiently high conductivities are used, and the limit at which the decrease occurs is dependent on the salt composition of the feedstock. These data illustrate the robust nature of the AEX recovery process for removal of viruses, and they indicate that proper design of AEX processes can ensure viral safety of mAb products.  相似文献   

11.
Protein A chromatography is widely used as a capture step in monoclonal antibody (mAb) purification processes. Antibodies and Fc fusion proteins can be efficiently purified from the majority of other complex components in harvested cell culture fluid (HCCF). Protein A chromatography is also capable of removing modest levels of viruses and is often validated for viral clearance. Historical data mining of Genentech and FDA/CDER databases systematically evaluated the removal of model viruses by Protein A chromatography. First, we found that for each model virus, removal by Protein A chromatography varies significantly across mAbs, while remains consistent within a specific mAb product, even across the acceptable ranges of the process parameters. In addition, our analysis revealed a correlation between retrovirus and parvovirus removal, with retrovirus data generally possessing a greater clearance factor. Finally, we describe a multivariate approach used to evaluate process parameter impacts on viral clearance, based on the levels of retrovirus‐like particles (RVLP) present among process characterization study samples. It was shown that RVLP removal by Protein A is robust, that is, parameter effects were not observed across the ranges tested. Robustness of RVLP removal by Protein A also correlates with that for other model viruses such as X‐MuLV, MMV, and SV40. The data supports that evaluating RVLP removal using process characterization study samples can establish multivariate acceptable ranges for virus removal by the protein A step for QbD. By measuring RVLP instead of a model retrovirus, it may alleviate some of the technical and economic challenges associated with performing large, design‐of‐experiment (DoE)—type virus spiking studies. This approach could also serve to provide useful insight when designing strategies to ensure viral safety in the manufacturing of a biopharmaceutical product. Biotechnol. Bioeng. 2014;111: 95–103. © 2013 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.  相似文献   

12.
Flowthrough anion exchange chromatography is commonly used as a polishing step in downstream processing of monoclonal antibodies and other therapeutic proteins to remove process‐related impurities and contaminants such as host cell DNA, host cell proteins, endotoxin, and viruses. DNA with a wide range of molecular weight distributions derived from Chinese Hamster Ovary cells was used to advance the understanding of DNA binding behavior in selected anion exchange media using the resin (Toyopearl SuperQ‐650M) and membranes (Mustang® Q and Sartobind® Q) through DNA spiking studies. The impacts of the process parameters pH (6–8), conductivity (2–15 mS/cm), and the potential binding competition between host cell proteins and host cell DNA were studied. Studies were conducted at the least and most favorable experimental conditions for DNA binding based on the anticipated electrostatic interactions between the host cell DNA and the resin ligand. The resin showed 50% higher DNA binding capacity compared to the membrane media. Spiking host cell proteins in the load material showed no impact on the DNA clearance capability of the anion exchange media. DNA size distributions were characterized based on a “size exclusion qPCR assay.” Results showed preferential binding of larger DNA fragments (>409 base pairs). © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 34:141–149, 2018  相似文献   

13.
Multicolumn capture chromatography is gaining increased attention lately due to the significant economic and process advantages it offers compared with traditional batch mode chromatography. However, for wide adoption of this technology in clinical and commercial space, it requires scalable models for executing viral validation studies. In this study, viral validation studies were conducted under cGLP guidelines to assess retro- (X-MuLV) and parvo-virus (MVM) clearance across twin-column continuous capture chromatography (CaptureSMB). A surrogate model was also developed using standard batch mode chromatography based on flow path modifications to mimic the loading strategy used in CaptureSMB. The results show that a steady state was achieved by the second cycle for both antibody binding and virus clearance and that the surrogate model using batch mode chromatography equipment provided impurity clearance that was comparable to that obtained during cyclical operation of CaptureSMB. Further, the log reduction values (LRVs) achieved during CaptureSMB were also comparable to the LRVs obtained using standard batch capture chromatography. This was expected since the mode of virus separation during protein A chromatography is primarily based on removal during the flow through and wash steps. Finally, this study also presents assessments on the resin cleaning strategy during continuous chromatography and how the duration of clean-in-place solution exposure impacts virus carryover.  相似文献   

14.
A multi‐tiered approach to determine the binding mechanism of viral clearance utilizing a multi‐modal anion exchange resin was applied to a panel of four viral species that are typically used in validating viral clearance studies (i.e., X‐MuLV, MVM, REO3, and PrV). First, virus spiked buffer‐only experiments were conducted to evaluate the virus's affinity for single mode and multi‐modal chromatography resins under different buffer conditions in a chromatography column setting. From these results we hypothesize that the mechanisms of binding of the viruses involve binding to both the hydrophobic and anionic functional groups. This mechanistic view agreed with the general surface characteristics of the different virus species in terms of isoelectric point and relative hydrophobicity values. This hypothesized mechanistic binding was then tested with commercially relevant, in‐process materials, in which competitive binding occurred between the load components (e.g., viruses, target product, and impurities) and the resin. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 34:1019–1026, 2018  相似文献   

15.
The contamination of oral rotavirus vaccines by porcine circovirus (PCV) raised questions about potential PCV contamination of other biological products when porcine trypsin or pepsin is used in production process. Several methods can be potentially implemented as a safety barrier when animal derived trypsin or pepsin is used. Removal of PCV is difficult by the commonly used viral filters with the pore size cutoff of approximately 20 nm because of the smaller size of PCV particles that are around 17 nm. It was speculated that operating the chromatography step at a pH higher than pepsin's low pI, but lower than pIs, of most viruses would allow the pepsin to flow through the resin and be recovered from the flow through pool whilst the viruses would be retained on the resin. In this study, we investigated low pH inactivation of viruses including PCV Type 1 (PCV1) and PCV1 removal by cation exchange chromatography (CEX) in the presence of pepsin. Both parvovirus and PCV1 could be effectively inactivated by low pH and PCV1 could be removed by POROS 50HS CEX. The POROS 50HS method presented in this article is helpful for designing other CEX methods for the same purpose and not much difference would be expected for similar product intermediates and same process parameters. While the effectiveness needs to be confirmed for specific applications, the results demonstrate that both low pH (pH 1.7) and CEX methods were successful in eliminating PCV1 and thus either can be considered as an effective virus barrier.  相似文献   

16.
Virus contamination in human therapeutics is of growing concern as more therapeutic products from animal or human sources come into the market. All biopharmaceutical processes are required to have at least two distinct viral clearance steps to remove viruses. Most of these steps work well for enveloped viruses and large viruses, whether enveloped or not. That leaves a class of small non-enveloped viruses, like parvoviruses and hepatitis A, which are not easily removed by these typical steps. In this study, we report the identification of trimeric peptides that bind specifically to porcine parvovirus (PPV) and their potential use to remove this virus from process solutions. All of the trimeric peptides isolated completely removed all detectable PPV from buffer in the first nine column volumes, corresponding to a clearance of 4.5-5.5 log of infectious virus. When the virus was spiked into a more complex matrix consisting of 7.5% human blood plasma, one of the trimers, WRW, was able to remove all detectable PPV in the first three column volumes, after which human blood plasma began to interfere with the binding of the virus to the peptide resin. These trimer resins removed considerably more virus than weak ion exchange resins. The results of this work indicate that small peptide ligand resins have the potential to be used in virus removal processes where removal of contaminating virus is necessary to ensure product safety.  相似文献   

17.
Clearance of impurities such as viruses, host cell protein (HCP), and DNA is a critical purification design consideration for manufacture of monoclonal antibody therapeutics. Anion exchange chromatography has frequently been utilized to accomplish this goal; however, anion exchange adsorbents based on the traditional quaternary amine (Q) ligand are sensitive to salt concentration, leading to reduced clearance levels of impurities at moderate salt concentrations (50–150 mM). In this report, membrane adsorbers incorporating four alternative salt tolerant anion exchange ligands were examined for impurity clearance: agmatine, tris‐2‐aminoethyl amine, polyhexamethylene biguanide (PHMB), and polyethyleneimine. Each of these ligands provided greater than 5 log reduction value (LRV) for viral clearance of phage ?X174 (pI ~ 6.7) at pH 7.5 and phage PR772 (pI ~ 4) at pH 4.2 in the presence of salt. Under these same conditions, the commercial Q membrane adsorber provided no clearance (zero LRV). Clearance of host‐cell protein at pH 7.5 was the most challenging test case; only PHMB maintained 1.5 LRV in 150 mM salt. The salt tolerance of PHMB was attributed to its large positive net charge through the presence of multiple biguanide groups that participated in electrostatic and hydrogen bonding interactions with the impurity molecules. On the basis of the results of this study, membrane adsorbers that incorporate salt tolerant anion exchange ligands provide a robust approach to impurity clearance during the purification of monoclonal antibodies. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

18.
Protein A chromatography is an effective capture step to separate Fc-containing biopharmaceuticals from cell culture impurities but is generally not effective for virus removal, which tends to vary among different products. Previous findings have pointed to the differences in feedstocks to protein A, composed of the products and other cell culture-related impurities. To separate the effect of the feedstock components on virus removal, and understand why certain monoclonal antibody (mAb) products have low virus log reduction values (LRVs) across protein A chromatography, we investigated the partitioning of three types of viruses on Eshmuno® A columns. Using pure mAbs, we found that low LRVs were correlated with the presence of the particular mAb product itself, causing altered partitioning patterns. Three virus types were tested, and the trend in partitioning was the same for retrovirus-like particles (RVLPs) expressed in the cell substrate, and its model virus xenotropic murine leukemia virus (XMuLV), whereas slightly different for murine minute virus. These results were extended from previous observation described by Bach and Connell-Crowley (2015) studying XMuLV partitioning on MabSelect SuRe columns, providing further evidence using additional types of viruses and resin. Other product-specific cell culture impurities in harvested cell culture fluid played a lesser role in causing low LRVs. In addition, using high throughput screening (HTS) methods and Eshmuno® A resin plates, we identified excipients with ionic and hydrophobic properties that could potentially alleviate the mAb-induced LRV reduction, indicating that both ionic and hydrophobic interactions were involved. More excipients of such nature or combinations, once optimized, can potentially be used as load and/or wash additives to improve virus removal by protein A. We have demonstrated that HTS is a valuable tool for this type of screening, whether to gain deeper understanding of a mechanism, or to provide guidance during the optimization of protein A process with improved virus removal.  相似文献   

19.
L Shi  L A Norling  A S Lau  S Krejci  A J Laney  Y Xu 《Biologicals》1999,27(3):253-262
Continuous cell lines used for pharmaceutical protein manufacturing have the potential to be contaminated by viruses. To ensure the safety of pharmaceutical proteins derived from continuous cell lines, validation of the ability of the manufacturing process to clear potential contaminating viruses is required for product registration. In this paper, a real time quantitative PCR method has been applied to the evaluation of simian virus 40 (SV40) removal during chromatography and filtration procedures. This method takes advantage of the 5'-3' exonuclease activity of Taq DNA polymerase and utilizes the PRISM 7700 sequence detection system of PE Applied Biosystems for automated SV40 DNA quantification through a dual-labeled fluorogenic probe. This method provides accurate and reproducible quantification of SV40 DNA. The SV40 clearance during chromatography and filtration procedures determined by this method is highly comparable with that determined by the cell-based infectivity assay. This method offers significant advantages over cell-based infectivity assays, such as higher sensitivity, greater reliability, higher sample throughput and lower cost. This method can be potentially used to evaluate the clearance of all model viruses during chromatography and filtration procedures. This method can be used to substitute cell-based infectivity assays for process validation of viral removal procedures and the availability of this method should greatly facilitate and reduce the cost of viral clearance evaluations required for new biologic product development.  相似文献   

20.
Strong anion exchange chromatography has frequently been employed as a viral clearance step during downstream processing of biological therapeutics. When challenged with viruses having only slightly acidic isoelectric points, the performance of the anion exchange operation becomes highly dependent on the buffer salt concentration, with the virus log reduction value (LRV) dropping dramatically in buffers with 50–150 mM salt. In this work, a series of anion exchange membrane adsorbers utilizing alternative ligand chemistries instead of the traditional quaternary amine (Q) ligand have been developed that overcome this limitation. Four different ligands (agmatine, tris‐2‐aminoethyl amine, polyhexamethylene biguanide, and polyethyleneimine) achieved >5 LRV of bacteriophage ΦX174 (pI ~ 6.7) at pH 7.5 and up to 150 mM salt, compared to 0 LRV for the Q ligand. By evaluating structural derivatives of the successful ligands, three factors were identified that contributed to ligand salt tolerance: ligand net charge, ligand immobilization density on the membrane, and molecular structure of the ligand‐binding group. Based on the results of this study, membrane adsorbers that incorporate alternative ligands provide a more robust and salt tolerant viral clearance‐processing step compared to traditional strong anion exchange membrane adsorbers. Biotechnol. Bioeng. 2009;103: 920–929. © 2009 Wiley Periodicals, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号