首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The study of intracellular communication requires devices that can not only monitor the bioelectric activity, but also control and observe the biochemical environment at the cellular level. This paper reports on the development and characterisation of implantable polyimide microprobes that allow simultaneous, selective chemical delivery/probing and multi-channel recording/stimulation of bioelectric activity. The key component of the system is a flexible polyimide substrate with embedded microchannels that is batch-fabricated combining polyimide micromachining and a lamination technique. The devices provide platinum microelectrodes on both sides of the polyimide substrate with an active surface between 20 microm x 20 microm and 50 microm x 50 microm. The embedded microchannels permit highly localised drug delivery or probing at the tip of the device via channel outlets adjacent to the microelectrodes. The microelectrodes were characterised by electrical impedance spectroscopy and the microchannels were studied in microflow experiments. Two different fluid delivery schemes were explored in two different designs. The first device type consists of a simple combination of microchannels and microelectrodes on one substrate. Liquids are ejected at the tip of the device by pressure injection techniques. The second device was inspired by the so-called U-tube concept allowing for highly localised delivery of controlled amounts of liquids in the picoliters range. Thus, the influence of chemical compounds on the electrical activity of cells can be studied with high temporal and spatial resolution. The flexible, implantable devices can be used for studying the chemical and electrical information exchange and communication of cells in in vivo and in vitro experiments.  相似文献   

2.
This paper reports an investigation into the flow behaviour of a biofluid in a microchannel systems through conceptual analysis and modelling. The application is the design of a microfluidic chip developed for the separation of plasma from blood. The effect of key design features of the microchannels on the flow behaviour of the biofluid is explored. These include geometric features such as the constriction, bending channel, bifurcation and the channel length ratio between the main and side channels. The performance of each design is discussed in terms of separation efficiency of the red blood cells with respect to the rest of the medium. Particular phenomena such as the Fahraeus and Fahraeus-Lindqvist effects, the Zweifach-Fung bifurcation law and the cell-free layer are discussed. In this paper, the fluid is modelled as a single-phase flow assuming either Newtonian or Non-Newtonian behaviour to investigate the effect of the fluid viscosity on both flow and separation efficiency. For a flow rate-controlled Newtonian flow system, it is found that viscosity and outlet pressure have little effect on the velocity distribution through each of the microchannels. For a diluted fluid where the flow in the whole channel system is modelled with a uniform viscosity, less plasma is separated from blood than observed in the non-Newtonian case. This results in an increase in the flow rate ratio between the main and side channels. A comparison of Newtonian and non-Newtonian flows shows that both flows tend to behave identically with an increase in the shear strain rate.  相似文献   

3.
This paper reports an investigation into the flow behaviour of a biofluid in a microchannel systems through conceptual analysis and modelling. The application is the design of a microfluidic chip developed for the separation of plasma from blood. The effect of key design features of the microchannels on the flow behaviour of the biofluid is explored. These include geometric features such as the constriction, bending channel, bifurcation and the channel length ratio between the main and side channels. The performance of each design is discussed in terms of separation efficiency of the red blood cells with respect to the rest of the medium. Particular phenomena such as the Fahraeus and Fahraeus–Lindqvist effects, the Zweifach–Fung bifurcation law and the cell-free layer are discussed. In this paper, the fluid is modelled as a single-phase flow assuming either Newtonian or Non-Newtonian behaviour to investigate the effect of the fluid viscosity on both flow and separation efficiency. For a flow rate-controlled Newtonian flow system, it is found that viscosity and outlet pressure have little effect on the velocity distribution through each of the microchannels. For a diluted fluid where the flow in the whole channel system is modelled with a uniform viscosity, less plasma is separated from blood than observed in the non-Newtonian case. This results in an increase in the flow rate ratio between the main and side channels. A comparison of Newtonian and non-Newtonian flows shows that both flows tend to behave identically with an increase in the shear strain rate.  相似文献   

4.
Target delivery in a microfluidic immunosensor   总被引:1,自引:0,他引:1  
A study is presented that examines the effect of microfluidic mixing elements on direct and sandwich assays performed in microchannels. Patterned grooves were embossed in the top of microchannels made in PDMS using soft lithography. The grooves redirected the fluid flowing in the channel, enhancing delivery of the target from the bulk fluid to the surface and preventing the formation of a depletion layer at the surface. Comparing assays in grooved and plain channels demonstrated that the mixers improved assay results by 26-46%. A computational flow analysis showed that the grooves caused virtual particles in the bulk flow to come close to the surface ( approximately 11 microm) which is consistent with the signal increase seen experimentally. Direct assays for several concentrations of CY5-labeled biotin were performed in the microchannels. The mixers also improved signal intensity in sandwich assays for botulinum toxin which required mixing of the reagents as well as the direction of the target to the surface.  相似文献   

5.
This study tested the hypothesis that controlled flow through microchannels can cause shear-induced intracellular loading of cells with molecules. The overall goal was to design a simple device to expose cells to fluid shear stress and thereby increase plasma membrane permeability. DU145 prostate cancer cells were exposed to fluid shear stress in the presence of fluorescent cell-impermeant molecules by using a cone-and-plate shearing device or high-velocity flow through microchannels. Using a syringe pump, cell suspensions were flowed through microchannels of 50-300 microm diameter drilled through Mylar sheets using an excimer laser. As quantified by flow cytometry, intracellular uptake and loss of viability correlated with the average shear stress. Optimal results were observed when exposing the cells to high shear stress for short durations in conical channels, which yielded uptake to over one-third of cells while maintaining viability at approximately 80%. This method was capable of loading cells with molecules including calcein (0.62 kDa), large molecule weight dextrans (150-2,000 kDa), and bovine serum albumin (66 kDa). These results supported the hypothesis that shear-induced intracellular uptake could be generated by flow of cell suspensions through microchannels and further led to the design of a simple, inexpensive, and effective device to deliver molecules into cells. Such a device could benefit biological research and the biotechnology industry.  相似文献   

6.
Microfluidic bioreactors have been shown valuable for various cellular applications. The use of micro-wells/grooves bioreactors, in which micro-topographical features are used to protect sensitive cells from the detrimental effects of fluidic shear stress, is a promising approach to culture sensitive cells in these perfusion microsystems. However, such devices exhibit substantially different fluid dynamics and mass transport characteristics compared to conventional planar microchannel reactors. In order to properly design and optimize these systems, fluid and mass transport issues playing a key role in microscale bioreactors should be adequately addressed. The present work is a parametric study of micro-groove/micro-well microchannel bioreactors. Operation conditions and design parameters were theoretically examined via a numerical model. The complex flow pattern obtained at grooves of various depths was studied and the shear protection factor compared to planar microchannels was evaluated. 3D flow simulations were preformed in order to examine the shear protection factor in micro-wells, which were found to have similar attributes as the grooves. The oxygen mass transport problem, which is coupled to the fluid mechanics problem, was solved for various groove geometries and for several cell types, assuming a defined shear stress limitation. It is shown that by optimizing the groove depth, the groove bioreactor may be used to effectively maximize the number of cells cultured within it or to minimize the oxygen gradient existing in such devices. Moreover, for sensitive cells having a high oxygen demand (e.g., hepatocytes) or low endurance to shear (e.g., human embryonic stem cells), results show that the use of grooves is an enabling technology, since under the same physical conditions the cells cannot be cultured for long periods of time in a planar microchannel. In addition to the theoretical model findings, the culture of human foreskin fibroblasts in groove (30 microm depth) and well bioreactors (35 microm depth) was experimentally examined at various flow rates of medium perfusion and compared to cell culture in regular flat microchannels. It was shown that the wells and the grooves enable a one order of magnitude increase in the maximum perfusion rate compared to planar microchannels. Altogether, the study demonstrates that the proper design and use of microgroove/well bioreactors may be highly beneficial for cell culture assays.  相似文献   

7.
目的:探讨无创血流动力学监测技术在严重脓毒症患者液体复苏后指导血管活性药物使用的意义。方法:选择2014年6月至2016年6月我院急诊处收治的严重脓毒症患者56例为研究对象,分为观察组和对照组,每组各28例。对照组进行常规对症治疗,观察组在对照组治疗基础上使用无创血流动力学监测仪指导治疗。观察两组患者在治疗前及治疗后6 h血流动力学及微循环灌注指标、液体复苏6 h后液体平衡量及血管活性药物使用量,及在重症监护病房(EICU)的入住时间。结果:治疗后两组患者尿量均大于30 m L/h,提示复苏成功。两组患者治疗后血液动力学指标和微循环灌注指标较治疗前均明显好转(均P0.05);治疗后,两组间血液动力学指标和微循环灌注指标比较无明显差异(P0.05)。观察组液体复苏6 h后液体平衡量明显少于对照组(P0.05),观察组血管活性药物用量均明显高于对照组(P0.05),观察组患者在EICU病房住院时间明显短于对照组(P0.05)。结论:无创血流动力学监测对严重脓毒症患者的液体恢复管理和治疗过程具有指导意义,使血管活性药物得到有效利用,精确进行液体管理,减少盲目补液,缩短病程,减少患者的住院时间,经济高效,是指导治疗和评估治疗疗效的重要手段。  相似文献   

8.
Conventional studies of the optimum growth conditions for methanogens (methane-producing, obligate anaerobic archaea) are typically conducted with serum bottles or bioreactors. The use of microfluidics to culture methanogens allows direct microscopic observations of the time-integrated response of growth. Here, we developed a microbioreactor (microBR) with approximately 1-microl microchannels to study some optimum growth conditions for the methanogen Methanosaeta concilii. The microBR is contained in an anaerobic chamber specifically designed to place it directly onto an inverted light microscope stage while maintaining a N2-CO2 environment. The methanogen was cultured for months inside microchannels of different widths. Channel width was manipulated to create various fluid velocities, allowing the direct study of the behavior and responses of M. concilii to various shear stresses and revealing an optimum shear level of approximately 20 to 35 microPa. Gradients in a single microchannel were then used to find an optimum pH level of 7.6 and an optimum total NH4-N concentration of less than 1,100 mg/liter (<47 mg/liter as free NH3-N) for M. concilii under conditions of the previously determined ideal shear stress and pH and at a temperature of 35 degrees C.  相似文献   

9.
Our purpose was to test a scale model of the microcirculation by measuring the shear forces to which endothelial cells were exposed, and comparing this to computer simulations. In vitro experiments were performed to measure the 2-dimensional projected velocity profile along endothelial cell lined microchannels (D-shaped, 10-30 microns radius, n = 15), or in microchannels without endothelial cells (n = 18). Microchannels were perfused with fluorescently labeled microspheres (0.5 micron dia., < 1%) suspended in cell culture media. The velocity of individual microspheres was obtained off-line (videorecording), using an interactive software program; velocity was determined as the distance traveled in one video field (1/60 s). Mass balance was verified in the microchannels by comparing the microsphere velocities to the perfusion pump rate. In confluent endothelial cell lined microchannels, a velocity profile was obtained as microspheres passed an endothelial cell nucleus (identified by fluorescent dye), and again, for a paired region 100 microns away without nuclei (cytoplasm region). The velocity profile was significantly shifted and sharpened by the endothelial cell nucleus, as anticipated. Over the nucleus, data are consistent with a normal sized nucleus extending into the lumen, further confirming that this scale model can be used to determine the wall shear stress to which endothelial cells are exposed. Using the experimental bulk phase fluid parameters as boundary conditions, we used computational fluid dynamics (CFD) to predict the expected wall shear stress gradient along an endothelial cell lined D-shaped tube. The wall shear stress gradient over the nucleus was 2-fold greater in the radial versus axial directions, and was sensitive to lateral versus midline positioned nuclei.  相似文献   

10.
Microfluidics can provide unique experimental tools to visualize the development of neural structures within a microscale device, which is followed by guidance of neurite growth in the axonal isolation compartment. We utilized microfluidics technology to monitor the differentiation and migration of neural cells derived from human embryonic stem cells (hESCs). We co-cultured hESCs with PA6 stromal cells, and isolated neural rosette-like structures, which subsequently formed neurospheres in suspension culture. Tuj1-positive neural cells, but not nestin-positive neural precursor cells (NPCs), were able to enter the microfluidics grooves (microchannels), suggesting that neural cell-migratory capacity was dependent upon neuronal differentiation stage. We also showed that bundles of axons formed and extended into the microchannels. Taken together, these results demonstrated that microfluidics technology can provide useful tools to study neurite outgrowth and axon guidance of neural cells, which are derived from human embryonic stem cells.  相似文献   

11.
Journal of Plant Research - Plasmodesmata are unique channel structures in plants that link the fluid cytoplasm between adjacent cells. Plants have evolved these microchannels to allow trafficking...  相似文献   

12.
We have demonstrated the fabrication of a two-level microfluidic device that can be easily integrated with existing electrophysiology setups. The two-level microfluidic device is fabricated using a two-step standard negative resist lithography process. The first level contains microchannels with inlet and outlet ports at each end. The second level contains microscale circular holes located midway of the channel length and centered along with channel width. Passive pumping method is used to pump fluids from the inlet port to the outlet port. The microfluidic device is integrated with off-the-shelf perfusion chambers and allows seamless integration with the electrophysiology setup. The fluids introduced at the inlet ports flow through the microchannels towards the outlet ports and also escape through the circular openings located on top of the microchannels into the bath of the perfusion. Thus the bottom surface of the brain slice placed in the perfusion chamber bath and above the microfluidic device can be exposed with different neurotransmitters. The microscale thickness of the microfluidic device and the transparent nature of the materials [glass coverslip and PDMS (polydimethylsiloxane)] used to make the microfluidic device allow microscopy of the brain slice. The microfluidic device allows modulation (both spatial and temporal) of the chemical stimuli introduced to the brain slice microenvironments.  相似文献   

13.
Current methods of microscope stage perfusion do not take full advantage of existing technology for precise fluid control. The concept of flow injection, used extensively by analytical chemists, is described and its application to the fluorescence microscopic study of cultured cells is proposed. Using this technique, cells may be exposed to single or multiple reagent zones of almost any profile, sequence, and duration, with computer-controlled precision. A flow injection system is employed in conjunction with a novel perfusion chamber—the fountain cell. The ability of the flow injection system to perfuse cells with a reagent with a reproducibility of 1% RSD is demonstrated. The system was used to monitor changes in calcium levels in baby hamster kidney cells loaded with FURA-2 as a result of stimulation with a precisely timed concentration of ionomycin. The unique feature of the technique is that it allows a series of responses of a given cell to be directly compared to each other.  相似文献   

14.
It is desired to understand the effect of alginic acid sodium salt from brown algae (alginate) as a viscosity modifier on the behavior of blood in vitro using a micro-particle image velocimetry (µPIV) system. The effect of alginate on the shape of the velocity profile, the flow rate and the maximum velocity achieved in rectangular microchannels channels are measured. The channels were constructed of polydimethylsiloxane (PDMS), a biocompatible silicone. Porcine blood cells suspended in saline was used as the working fluid at twenty percent hematocrit (H = 20). While alginate was only found to have minimal effect on the maximum velocity and the flow rate achieved, it was found to significantly affect the shear rate at the wall by between eight to a hundred percent.  相似文献   

15.
Microfluidic networks are extensively used in miniaturized lab-on-a-chip systems. However, most of the existing micro- channels are simply designed and the corresponding microfluidic systems commonly require external pumps to achieve effec- tive fluid transport. Here we employed microfabrication techniques to replicate naturally-optimized leaf venations into synthetic hydrogels for the fabrication of pumpless microfluidic chips. The unique properties of leaf-inspired microfluidic network in convectively transporting fluid were characterized at different inclination angles. Flow velocity inside these microfluidic net- works was quantitatively measured with Particle Image Velocimetry (PIV). Mass diffusion from biomimetic microfluidic network to surrounding bulk hydrogels was investigated. The results demonstrate that the leaf-inspired microfluidic network can not only effectively transport fluid without the use of external pumps, but also facilitate rapid mass diffusion within bulk hy- drogel chips. These leaf-inspired microfluidic networks could be potentially used to engineer complex pumpless or- gan-on-a-chip systems.  相似文献   

16.
Conventional studies of the optimum growth conditions for methanogens (methane-producing, obligate anaerobic archaea) are typically conducted with serum bottles or bioreactors. The use of microfluidics to culture methanogens allows direct microscopic observations of the time-integrated response of growth. Here, we developed a microbioreactor (μBR) with ~1-μl microchannels to study some optimum growth conditions for the methanogen Methanosaeta concilii. The μBR is contained in an anaerobic chamber specifically designed to place it directly onto an inverted light microscope stage while maintaining a N2-CO2 environment. The methanogen was cultured for months inside microchannels of different widths. Channel width was manipulated to create various fluid velocities, allowing the direct study of the behavior and responses of M. concilii to various shear stresses and revealing an optimum shear level of ~20 to 35 μPa. Gradients in a single microchannel were then used to find an optimum pH level of 7.6 and an optimum total NH4-N concentration of less than 1,100 mg/liter (<47 mg/liter as free NH3-N) for M. concilii under conditions of the previously determined ideal shear stress and pH and at a temperature of 35°C.  相似文献   

17.
The exine of birch pollen was examined by scanning and transmission electron microscopy in the native state and after fixation in different aqueous fixatives: glutaraldehyde + OsO4; glutaraldehyde + cetylpyridinium chloride (CPC) + OsO4; glutaraldehyde + cuprolinic blue (CB); and periodate + lysine + paraformaldehyde (PLP). The native pollen exine showed a thin (3-5-nm) border of electron-dense material lining the tectum and electron-dense material within microchannels and bacula cavities. Fixation with the addition of CPC resulted in a voluminous surface coat surrounding the pollen grain, but empty microchannels and bacula cavities. After fixation with the addition of CB, there was a thin surface coat, whereas microchannels and bacula cavities were partially filled with electron-dense material. The other fixatives led to empty microchannels and bacula cavities. There was no surface coat on the pollen grain. However, after all fixation procedures, a thin electron-dense border of the tectum remained visible. Concerning the electron-dense material filling microchannels and bacula cavities in the native pollen grain, the results obtained in the present study suggest that it is either completely lost (after conventional and PLP fixation) or, after fixation with a precipitating additive, partially (CB) or completely (CPC) solubilized and precipitated on the surface of the pollen grain as a surface coat.  相似文献   

18.
Efforts have been focused on developing in vitro assays for the study of microvessels because in vivo animal studies are more time-consuming, expensive, and observation and quantification are very challenging. However, conventional in vitro microvessel assays have limitations when representing in vivo microvessels with respect to three-dimensional (3D) geometry and providing continuous fluid flow. Using a combination of photolithographic reflowable photoresist technique, soft lithography, and microfluidics, we have developed a multi-depth circular cross-sectional endothelialized microchannels-on-a-chip, which mimics the 3D geometry of in vivo microvessels and runs under controlled continuous perfusion flow. A positive reflowable photoresist was used to fabricate a master mold with a semicircular cross-sectional microchannel network. By the alignment and bonding of the two polydimethylsiloxane (PDMS) microchannels replicated from the master mold, a cylindrical microchannel network was created. The diameters of the microchannels can be well controlled. In addition, primary human umbilical vein endothelial cells (HUVECs) seeded inside the chip showed that the cells lined the inner surface of the microchannels under controlled perfusion lasting for a time period between 4 days to 2 weeks.  相似文献   

19.
利用CAD和快速成形技术设计制造具有可控多孔结构的支架。构建灌注式生物反应器系统,实现氧气和营养物质的大量输送,同时产生一定流体剪应力,调节细胞功能的发挥。根据支架负型结构制造出相应的树脂原型,用磷酸钙骨水泥进行填充烧结,得到与设计相符的多孔支架。接种兔成骨细胞,分别采用静态和灌注式三维动态培养方法,观察不同培养条件下细胞在支架表面以及所构造微管道内的生长情况。试验结果表明,灌注式体外培养方法更有利于细胞在支架微管道内的存活和功能的发挥,此灌注式系统能够改善支架微管道内细胞生存的微环境,增强黏附在支架微管道内细胞的活性,促进细胞进一步的增殖和矿化基质的产生。  相似文献   

20.
Most microfluidic chips utilize off-chip hardware (syringe pumps, computer-controlled solenoid valves, pressure regulators, etc.) to control fluid flow on-chip. This expensive, bulky, and power-consuming hardware severely limits the utility of microfluidic instruments in resource-limited or point-of-care contexts, where the cost, size, and power consumption of the instrument must be limited. In this work, we present a technique for on-chip fluid control that requires no off-chip hardware. We accomplish this by using inert compounds to change the density of one fluid in the chip. If one fluid is made 2% more dense than a second fluid, when the fluids flow together under laminar flow the interface between the fluids quickly reorients to be orthogonal to Earth’s gravitational force. If the channel containing the fluids then splits into two channels, the amount of each fluid flowing into each channel is precisely determined by the angle of the channels relative to gravity. Thus, any fluid can be routed in any direction and mixed in any desired ratio on-chip simply by holding the chip at a certain angle. This approach allows for sophisticated control of on-chip fluids with no off-chip control hardware, significantly reducing the cost of microfluidic instruments in point-of-care or resource-limited settings.  相似文献   