首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).  相似文献   

2.
Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.  相似文献   

3.
PurposeThe aim of this work was to develop a computational scheme for the correction of the LET dependence on the MOSFET response in water phantom dose measurements for a spread-out Bragg peak (SOBP) proton beam.MethodsThe LET dependence of MOSFET was attributed to the stopping power ratio of SiO2 to H2O and to the fractional hole yield in the SiO2 layer. Using literature values for the stopping powers of the continuous slowing down approximation and measured fractional hole yields vs. electric field and LET, formulas were derived for the computation of a dose-weighted correction factor of a SOBP beam.ResultsDose-weighted correction factors were computed for a clinical 190-MeV proton SOBP beam in a high-density polyethylene phantom. By applying correction factors to the SOBP beam, which consisted of weighted monoenergetic Bragg peaks, the MOSFET outputs were predicted and agreed well with the measured MOSFET responses.ConclusionBy applying LET dependent correction factors to MOSFET data, quality assurance of dose verification based on MOSFET measurements becomes possible for proton therapy.  相似文献   

4.
Humans are exposed to some compounds by more than one route. This occurs incidentally with environmental pollutants, and intentionally in the medical use of drugs. Dose-response functions given estimates of the received dose as a function of dose applied (and typically time) may be available for each route separately. Under mild regularity conditions, the two functions can be combined (numerically or analytically) to provide a function giving dose pairs for the alternative routes which are equivalent in terms of received dose. With Gaussian errors, the estimation is maximum likelihood and, more generally, asymptotically unbiased and least squares. The same approach may be applied to characteristics such as the maximum response level and area under the curve. Confidence limits are available for the difference between responses. Finally, other applications are discussed. The methods can also be used to compare compounds or species.  相似文献   

5.
The purpose of this study was to explore the effect of the second bend of the maze, on the neutron dose equivalent, in the 15 MV linear accelerator vault, with two bend maze. These two bends of the maze were covered by 32 points where the neutron dose equivalent was measured. There is one available method for estimation of the neutron dose equivalent at the entrance door of the two bend maze which was tested using the results of the measurements. The results of this study show that the neutron equivalent dose at the door of the two bend maze was reduced almost three orders of magnitude. The measured TVD in the first bend (closer to the inner maze entrance) is about 5 m. The measured TVD result is close to the TVD values usually used in the proposed models for estimation of neutron dose equivalent at the entrance door of the single bend maze. The results also determined that the TVD in the second bend (next to the maze entrance door) is significantly lower than the TVD values found in the first maze bend.  相似文献   

6.
A modified analytical expression is proposed for the revised quality factor that has been suggested by a liaison group of ICRP and ICRU. With this modification one obtains, for sparsely ionizing radiation, a quality factor which is proportional to the dose average of lineal energy, y. It is shown that the proposed relation between the quality factor and lineal energy can be translated into a largely equivalent dependence on LET. The choice between the reference parameters LET or y is therefore a secondary problem in an impending revision of the quality factor.  相似文献   

7.
PurposeThe purpose of this study was to; (1) investigate employing a novel position-sensitive mega-size polycarbonate (MSPC) dosimeter for photoneutron (PN) depth, profile and dose equivalent distributions studies in a multilayer polyethylene phantom in a Siemens ONCOR accelerator, and (2) develop depth dose equivalent distribution matrix data at different depths and positions of the phantom for patient PN dose equivalent determination and in particular for PN secondary cancer risk estimation.MethodsPosition-sensitive MSPC dosimeters were successfully exposed at 9 different depths of the phantom in a 10 × 10 cm2 X-ray field. The dosimeters were processed in mega-size electrochemical chambers at optimum conditions. Each MSPC dosimeter was placed at a known phantom depth for PN depth dose equivalents and profiles on transverse, longitudinal and diagonal axes and isodose equivalent distribution studies in and out of the X-ray beam.ResultsPN dose equivalent distributions at any depth showed the highest value at the beam central axis and decreases as the distance increases. PN dose equivalent at any position studied in the axes has a maximum value on the phantom surface which decreases as depth increases due to flux reduction by multi-elastic scattering interactions.ConclusionsExtensive PN dose equivalent matrix data at different depths and positions in the phantom were determined. The position-sensitive MSPC dosimeters proved to be highly efficient for PN depth, profile and isodose equivalent distribution studies. The extensive data obtained highly assists for determining PN dose equivalent of a patient undergoing high-energy X-ray therapy and for PN secondary cancer risk estimation.  相似文献   

8.
Widespread evidence indicates that exposure of cell populations to ionizing radiation results in significant biological changes in both the irradiated and nonirradiated bystander cells in the population. We investigated the role of radiation quality, or linear energy transfer (LET), and radiation dose in the propagation of stressful effects in the progeny of bystander cells. Confluent normal human cell cultures were exposed to low or high doses of 1GeV/u iron ions (LET ~ 151 keV/μm), 600 MeV/u silicon ions (LET ~ 51 keV/μm), or 1 GeV protons (LET ~ 0.2 keV/μm). Within minutes after irradiation, the cells were trypsinized and co-cultured with nonirradiated cells for 5 h. During this time, irradiated and nonirradiated cells were grown on either side of an insert with 3-μm pores. Nonirradiated cells were then harvested and allowed to grow for 20 generations. Relative to controls, the progeny of bystander cells that were co-cultured with cells irradiated with iron or silicon ions, but not protons, exhibited reduced cloning efficiency and harbored higher levels of chromosomal damage, protein oxidation and lipid peroxidation. This correlated with decreased activity of antioxidant enzymes, inactivation of the redox-sensitive metabolic enzyme aconitase, and altered translation of proteins encoded by mitochondrial DNA. Together, the results demonstrate that the long-term consequences of the induced nontargeted effects greatly depend on the quality and dose of the radiation and involve persistent oxidative stress due to induced perturbations in oxidative metabolism. They are relevant to estimates of health risks from exposures to space radiation and the emergence of second malignancies after radiotherapy.  相似文献   

9.
To investigate effects of low dose heavy particle radiation to CNS system, we adopted mouse neonatal brain cells in culture being exposed to heavy ions generated by HIMAC at NIRS and BNL. The applied dose varied from 0.05 Gy up to 2.0 Gy. The subsequent biological effects were evaluated by an induction of apoptosis focusing on the dependencies of (1) the animal strains with different radiation sensitivities, and (2) LET with different nuclei. Of the three mouse strains, SCID, B6 and C3H, used for brain cell culture, SCID was the most sensitive and C3H the least sensitive to both X-ray and carbon ion ( 290 MeV/n) as evaluated by 10% apoptotic criterion. However, the sensitivity differences among the strains were much smaller in case of carbon ion comparing to that of X-ray. Regarding the LET dependency, the sensitivity was compared with using C3H and B6 cells between the carbon (13 keV/micrometers) and neon (70 keV/micrometers) ions. Carbon (290 MeV/n) did not give a detectable LET dependency from the criterion whereas the neon (400 MeV/n) showed 1.4 fold difference for both C3H and B6 cells. Although a LET dependency was examined by using the most sensitive SCID cells, no significant difference was detected.  相似文献   

10.
Organ or tissue equivalent dose, the most important quantity in radiation protection, cannot be measured directly. Therefore it became common practice to calculate the quantity of interest with Monte Carlo methods applied to so-called human phantoms, which are virtual representations of the human body. The Monte Carlo computer code determines conversion coefficients, which are ratios between organ or tissue equivalent dose and measurable quantities. Conversion coefficients have been published by the ICRP (Report No. 74) for various types of radiation, energies and fields, which have been calculated, among others, with the mathematical phantoms ADAM and EVA. Since then progress of image processing, and of clock speed and memory capacity of computers made it possible to create so-called voxel phantoms, which are a far more realistic representation of the human body. Voxel (Volume pixel) phantoms are built from segmented CT and/or MRI images of real persons. A complete set of such images can be joined to a 3-dimensional representation of the human body, which can be linked to a Monte Carlo code allowing for particle transport calculations. A modified version of the VOX_TISS8 human voxel phantom (Yale University) has been connected to the EGS4 Monte Carlo code. The paper explains the modifications, which have been made, the method of coupling the voxel phantom with the code, and presents results as conversion coefficients between organ equivalent dose and kerma in air for external photon radiation. A comparison of the results with published data shows good agreement.  相似文献   

11.
To explore the potential of utilizing Compton scattered x-ray photons for imaging applications, it is critical to accurately evaluate scattered x-ray transmission properties of targeted tissue materials. In this study, scattered x-ray transmission of breast tissue equivalent phantoms was evaluated. Firstly, two validations were carried out using a primary x-ray beam at 80 kVp with both experimental measurement (ion chamber with narrow-beam setup) and analytical calculation (Spektr toolkit). The tungsten-anode x-ray spectrum model was thus validated by measuring and calculating the transmission through increasing thickness of 1100 Aluminum filters. Similarly, the composition models of breast tissue equivalent phantoms (CIRS, 012A) were validated by measuring and calculating x-ray transmission for three different breast compositions (BR30/70, BR50/50, and BR70/30). Following validation, transmission properties of Compton scattered x-ray photons were measured with a GOS based linear array detector at the 90° angle from the primary beam. The same study was performed through three independent approaches: experimental measurement, analytical calculation, and Monte Carlo simulation (GEANT4). For all three methods, the scattered x-ray photon transmission as functions of phantom thickness were determined and fit into exponential functions. The transmission curves from all three methods matched reasonably well, with a maximum difference of 6.3% for the estimated effective attenuation coefficients of the BR50/50 phantom. The relative difference among the three methods of estimated attenuation is under 3.5%. As an initial step to develop a novel Compton scatter-based breast imaging system, the quantitative results from this study paved a fundamental base for future work.  相似文献   

12.
The results of the induction of the point and the deletion mutations by the radiation with broad region of linear energy transfer (LET) ox Escherichia coli cells. The linear-quadratic function for point mutation induction was shown in comparison with linear dependence for deletion mutations. The relative biological effectiveness (RBE) is described as a function of LET by dependence with a local maximum. The greatest RBE coefficients for the lethal effects, gene and deletion mutation induction realize under different LET of heavy charged particles.  相似文献   

13.
Resolving the LET spectrum of environmental radiation in space for assessing dose equivalents creates special problems due to superposition effects. Three components of the radiation field in space, trapped protons, tissue disintegration stars, and neutrons, contribute the bulk of the total dose equivalent. While lack of discrimination of neutron recoil and trapped primary protons does not interfere with correct determination of the combined dose equivalent as such, the simultaneous bursts of several low-energy protons and alpha particles from tissue disintegration stars completely defy LET-resolution with conventional instrumentation. So far, the tissue star dose has been determined only semiquantitatively from nuclear emulsion data. The neutron spectrum in space shows a markedly higher relative fluence in the region beyond 5 MeV than the fission neutron spectrum. Therefore, its LET spectrum centers less heavily on LET values near the proton Bragg Peak. This would call for assigning a QF value of less than 10 to the neutron dose in space. Still more serious shortcomings exist with regard to LET interpretation of heavy primaries.  相似文献   

14.
The dosimetric package used inside Biorack on board STS76, STS81 and STS84 comprises passive detector stacks built from plastic nuclear track detectors (PNTDs), thermoluminescence detectors (TLDs) and one or two active DOSTEL (DOSimetric TELescope) units using planar silicon detectors. Five passive detector stacks were exposed at different places inside the BIORACK incubators and in different stowage positions. DOSTEL units were exposed inside the 22 degrees C incubator in all flights. Mission integrated dose measurements, particle fluence rates and neutron doses are obtained from the passive detector stacks. These results are complemented by time resolved particle counts and dose rates and linear energy transfer (LET) spectra separately for the contribution of the trapped particles and the galactic cosmic rays (GCR) as a result of the DOSTEL measurements. In addition, it was possible to investigate the anisotropy of the radiation field inside Biorack by the use of a second DOSTEL unit on STS84. Since all exposures are during a solar minimum period, the total radiation exposure is of a similar extent for all flights, although position differences in dose rate up to a factor of two are observed. Particle fluence rates show lower variations. Mission averaged mean quality factors (Q) determined from the LET spectra are 2.0+/-0.1; the deduced dose equivalent rates range from 631 to 716 microSv/day.  相似文献   

15.
Peculiarities of induction of single- and double-strand DNA breaks (SSR and DSB) in E. coli cells by ionizing radiation of different LET are discussed. On the basis of the model proposed the dependence of the yield of SSR and different types of DSB upon LET was calculated. It was shown that enzymatic DSB were mainly induced by gamma-radiation. As LET increased the yield of enzymatic DSB decreased and that of direct DSR increased.  相似文献   

16.
A recently developed method for the direct measurement of the restricted dose mean LET (cutoff energy = 500 eV) of an unspecified photon or electron radiation field with the high-pressure ionization chamber has been utilized to investigate the variation of this radiobiologically important parameter outside the primary beam of a clinical 60Co unit. A small high-pressure tissue-equivalent ionization chamber was used, and its characteristics and experimental considerations for the present investigation are reported. Measurement of the restricted dose mean LET at the examined points outside the primary 60Co beam showed an increase of 50% with respect to the restricted dose mean LET of the uncollimated 60Co beam. No significant variation was noted with off-central axis distance, field size, wedge filter, or depth below Perspex slabs. Dose rates at the points of measurement outside the primary 60Co beam were 1-5% of the dose rate in the primary beam.  相似文献   

17.
A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.  相似文献   

18.
Histologic and immunofluorescence methods were used to analyse the presence of fibronectin, chondroitin-4-sulphate and chondroitin-6-sulphate, type III and IV collagens, laminin, and keratins to assess the maturation level of cultured dermal and skin equivalents. In a first phase, fibroblasts in monolayer culture were compared with dermal equivalents in which fibroblasts are embedded in a type I collagen gel. Different fluorescent patterns were observed depending on the culture system used. A sequential appearance of macromolecules was noticed in dermal equivalents. Fibronectin was first detected after 4 days of culture, whereas chondroitin-4-sulphate and chondroitin-6-sulphate and type III collagen were present after 7 days. In contrast, all three macromolecules were detected at 24 h of culture in fibroblastic monolayer cultures. In a second phase, the quality of our skin equivalents was evaluated according to the seeding time of epidermal cells upon dermal equivalents (1, 4, or 7 days). A satisfactory stratification was obtained when keratinocytes were seeded after 4 and 7 days of dermal equivalent culture. Laminin and fibronectin were detected at the dermo-epidermal junction, but type IV collagen was absent. Various keratins, as detected by the AE1, AE2, and AE3 antibodies, were present in the epidermal layer. Following keratinocyte confluence, a change in the organization pattern of type III collagen in the dermal fraction of the skin equivalent was also noticed. Our comparative results show that seeding of epidermal cells on a more mature dermal equivalent leads to improved differentiation status of the epidermal layer.  相似文献   

19.
The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios.  相似文献   

20.
The problem of obtaining Helmholtz equivalents for nonlinear resistive one-ports is considered. Two fundamentally different classes of equivalent are described, one local and the other global. For each, necessary and sufficient conditions are derived for the existence and uniqueness of either the Thévenin equivalent or the Norton equivalent or both. These concepts are illustrated (i) by proving that a cell whose channels and pumps are monotone in the membrane potential will, in the absence of net state changes in these ionophores, possess a unique stable resting potential and (ii) by demonstrating that it is in principle impossible to assign unique equivalent circuits to such ionophores.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号