1.
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.  相似文献   

2.
Data of 3,097 blood culture sets processed with the BacT/Alert system in 1997 were compared to those of 3,158 blood culture sets processed with BACTEC 9240 in 1999. Agents responsible for bloodstream infections (BSI) were detected in 15.9% and 20.0% of blood cultures in 1997 and 1999, respectively. The incidence of BSI was 9.3 (1997) vs. 11.3 (1999) per 1,000 admissions. In both years, S. aureus was the most frequent isolate, followed by E. coli. Overall, the mean detection time (MDT) obtained with the BACTEC 9240 was significantly shorter than that of the BacT/Alert. Significant MDT differences were found for all organisms, except for Enterobacteriaceae (12.7 vs. 10.6 h). With both systems, over 95% positive samples were detected within 3 days, indicating that a 4-day incubation protocol may disclose most BSI agents. Thus, the added speed of the BACTEC 9240 allowed a particularly fast clinical management of septic patients.  相似文献   

3.
Living tissue engineering for regenerative therapy cannot withstand the usual pharmacopoeia methods of purification and terminal sterilization. Consequently, these products must be manufactured under aseptic conditions at microbiologically controlled environment facilities. This study was proposed to validate BacT/ALERT(?)3D automated culture system for microbiological control of epithelial cell culture medium (ECCM). Suspensions of the nine microorganisms recommended by the European Pharmacopoeia (Chap. 2.6.27: "Microbiological control of cellular products"), plus one species from oral mucosa and two negative controls with no microorganisms were prepared in ECCM. They were inoculated in FA (anaerobic) and SN (aerobic) culture bottles (Biomérieux, Lyon, France) and incubated in a BacT/ALERT(?)3D automated culture system. For each species, five sets of bottles were inoculated for reproducibility testing: one sample was incubated at the French Health Products Agency laboratory (reference) and the four others at Cell and Tissue Bank of Lyon, France. The specificity of the positive culture bottles was verified by Gram staining and then subcultured to identify the microorganism grown. The BacT/ALERT(?)3D system detected all the inoculated microorganisms in less than 2 days except Propionibacterium acnes which was detected in 3 days. In conclusion, this study demonstrates that the BacT/ALERT(?)3D system can detect both aerobic and anaerobic bacterial and fungal contamination of an epithelial cell culture medium consistent with the European Pharmacopoeia chapter 2.6.27 recommendations. It showed the specificity, sensitivity, and precision of the BacT/ALERT(?)3D method, since all the microorganisms seeded were detected in both sites and the uncontaminated medium ECCM remained negative at 7 days.  相似文献   

4.
BACKGROUND: In February 2004, FDA approved a supplement to our biologics license for Carticel, autologous cultured chondrocytes, to use the BacT/ALERT microbial detection system as an alternative to the compendial sterility test for lot release. This article provides a roadmap to our approval process. The approval represents more than 4 years of development and validation studies comparing the Steritest compact system to the BacT/ALERT microbial detection system. METHODS: For this study, freshly cultured chondrocytes were prepared from a characterized cell bank. Microbial isolates were prepared from either American Type Culture Collection (ATCC) strains or from in-house contaminants. For each test condition, a suspension of chondrocyte cells and test organisms was inoculated into both aerobic media (SA standard adult culture bottles, FA FAN, tryptic soy broth) and anaerobic media (SN standard adult culture bottles, FN FAN, fluid thioglycollate media) and tested for sterility using the Steritest compact system (Millipore, Bedford, MA, USA) and the BacT/ALERT microbial detection system (bioMerieux, Durham, NC, USA). Negative control bottles were inoculated with chondrocytes and no microorganisms. All bottles were incubated for 14 days and read daily. Bacterial growth was determined by either visual examination of Steritest canisters or detection of a positive by the BacT/ALERT system. A gram stain and streak plate were used to confirm positive bottles and negative bottles after 14 days. RESULTS: The detection of a positive by either the Steritest compact system or the BacT/ALERT system was summarized for each organism in each validation study. Data generated from studies reducing the incubation temperature from 35 degrees C to 32 degrees C improved detection times in the automated method compared with the compendial method. Other improvements included the use of FAN aerobic and anaerobic media to absorb the gentamicin contained in the culture media of prepared chondrocyte samples. Chondrocytes alone did not generate positive results in either the compendial method or the automated method. DISCUSSION: Data from validation studies support the use of the BacT/ALERT microbial detection system as an alternative sterility test for Carticel.  相似文献   

5.
We compared the performance of the BacT/ALERT automated blood culture system with real-time, quantitative volatile organic compound (VOC) detection by selected ion flow tube-mass spectrometry (SIFT-MS). Blood samples from healthy donors were artificially infected with 5 or 100 CFU of organisms commonly causing bacteremia. Positive results by SIFT-MS analysis of headspace gases were recorded for 53/60 (88.3%) bottles at 8h, and 58/60 (96.6%) bottles at 24 h. We conclude that SIFT-MS is a sensitive method for the detection of microbial VOCs. Furthermore, profiles of the VOCs detected may allow simultaneous identification of infecting organisms.  相似文献   

6.
BackgroundBlood volume may profoundly affect the isolation of microorganisms in blood cultures. The effect of blood volume in standard anaerobic bottles of the BacT/ALERT 3D system was investigated.MethodsAdult patients who visited the emergency department and referred for blood culture (n = 824) were enrolled from June to September 2013. Two sets of blood cultures were obtained from each patient. One set consisted of 5 mL that was collected in a standard aerobic bottle (SA5), 5 mL that was collected in a standard anaerobic bottle (SN5), and 10 mL that was collected in a standard anaerobic bottle (SN10). The growth of clinically significant pathogens and the time to detection (TTD) were compared between the SN5 and SN10 samples.ResultsIncreasing the volume of blood collected from 5 to 10 mL yielded a 14.7% improvement in the isolation of microorganisms. There was a statistically significant difference in the isolation of pathogens (14 vs. 30, P = 0.023) between the SN5 and SN10 samples. Gram-positive microorganisms were detected earlier in the SN10 samples than the SN5 samples (P = 0.052). The mean TTD of all pathogens was 13.5 h for the SN5 samples and 12.9 h for the SN10 samples (P = 0.099).ConclusionIncreased blood volume in the SN bottle yielded a significantly higher pathogen detection rate. However, there was no difference in the frequency of earlier detection or TTD between the SN5 and SN10 samples.  相似文献   

7.
To achieve faster bacteremia diagnosis, selected ion flow tube mass spectrometry (SIFT-MS) measured metabolic gases in the headspaces of BacT/ALERT blood culture bottles. Pseudomonas aeruginosa, Streptococcus pneumoniae, Escherichia coli, Staphylococcus aureus and Neisseria meningitidis growth and trace gas patterns were detected from 10 colony forming units after 6 h.  相似文献   

8.
Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.  相似文献   

9.
This study evaluates the effect of preincubation on delayed-entry samples for fastidious organisms including the HACEK group, Streptococcus species, Neisseria meningitidis, Haemophilus species and Corynebacterium species for the BacT/ALERT 3D System (bioMérieux) using the FA (aerobic) medium.Bottles were inoculated with two different concentrations (0.5 McFarland and a 1:100,000 dilution) of each organism and either loaded into the system immediately or stored at 4 °C, room temperature (RT) or 37 °C for 24 hours (h) prior to loading.The detection rate (DR) was 92.5% for bottles loaded immediately for both concentrations with a mean time to detection (TTD) of 26.7 h (standard deviation (SD): 14.7 h) for the low concentration and 9.21 h (SD: 5.3 h) for the high concentration. Preincubation at 4 °C did not affect the DR for either of the two concentrations in comparison to no preincubation. The DR at RT was 90.0% for the low concentration and 83.6% for the high concentration. At 37 °C the DR was 76.3% and 66.3% for the low and the high concentrations respectively. The average TTD was inversely correlated with the preincubation temperature. An incubation of four days was sufficient, with the exception of Eikenella corrodens and Gemella sanguinis. The serotype of Streptococcus pneumoniae or Neisseria meningitidis did not influence the TTD. Kingella kingae remained undetected.For the retrieval of the above mentioned bacteria we recommend storage of bottles at room temperature. In case of erroneous storage at 37 °C subcultivation is advisable.All cases with a negative result on day four should be reevaluated and eventually new material for alternative diagnostic procedures should be retrieved.  相似文献   

10.
Mobiluncus curtisii was isolated from the blood of a 35-year-old man with a medical history of ulcerative colitis who was admitted unconscious to the Intensive Care Unit (ICU). A CT scan revealed massive intracerebral hemorrhage in the left hemisphere. Temperature remained constant over 38.5 degrees C; therefore, two sets of blood cultures were collected. One anaerobic bottle BacT/ALERT SN (bioMerieux, France) was detected as positive after 5 days of incubation and a Gram stain confirmed a gram variable curved-shaped rod. The patient died 18 h after being admitted to the hospital.  相似文献   

11.
张国荣  彭松庆  张秋 《中国微生态学杂志》2012,24(8):750+759-750,759
目的对手工法双相血培养瓶和BACTEC9120全自动血培养仪的阳性率作回顾性分析。方法将血液标本同时接种双相血培养基和BACTEC9120全自动血培养仪配套血瓶中,将阳性结果移种血平板,如为阴性再移种巧克力平板。结果370例血培养,双相血培养瓶阳性25例,阳性率为6.76%(25/370),树脂需氧(儿童)瓶BACTEC9120报警显示阳性59例,阳性率为15.9%(59/370),阳性标本移种到血平板及巧克力平板阳性54例,阳性率为14.6%(54/370),假阳性5例,假阳性率为1.4%(5/370),共有29例树脂需氧(儿童)瓶阳性,而双相血培养瓶为阴性,P〈0.001。结论BACTEC9120全自动血培养仪提高阳性率,缩短阳性的报告时间优于传统的双相血培养基。  相似文献   

12.

Background

Mycobacterium species are grown using specific media that increase laboratory cost, thus hampering their diffusion in resource-limited countries. Preliminary data suggested that versatile blood agar may be also used for mycobacterial culture.

Methodology

We examined the growth of 41 different Mycobacterium species on 5% blood agar. Over a 24-month period we analysed isolation of mycobacteria after parallel inoculation of clinical specimens into both a reference automated system (BACTEC 9000 MB broth) and 5% blood agar slant tubes, after NaOH decontamination, and compared the cost of performing 1,000 analyses using these two techniques.

Conclusions

Mycobacterium reference species cultured on blood agar, with the exception of Mycobacterium ulcerans. Inoculation of 1,634 specimens yielded 95 Mycobacterium isolates. Blood agar performed significantly more efficiently than BACTEC 9000 MB broth (94 vs 88 isolates, P = 0.03). Decontamination of Candida albicans in 5 specimens by addition of amphotericin B in blood agar yielded one more M. tuberculosis isolate that could not be isolated in BACTEC broth. Uneven distribution of time to culture positivity for M. tuberculosis had a median (range) of 19±5 days using blood agar and 26±6 days using BACTEC 9000 MB broth. Cost for 1,000 analyses in France was estimated to be of 1,913 euros using the blood agar method and 8,990 euros using the BACTEC 9000 MB method. Blood agar should be regarded as a first-line medium for culturing Mycobacterium species. It saves time, is cost-effective, is more sensitive than, and at least as rapid as the automated method. This is of particular importance for resource-limited countries in which the prevalence of tuberculosis is high.  相似文献   

13.
Evaluation of Radiometric System for Detecting Bacteremia   总被引:21,自引:4,他引:17       下载免费PDF全文
An automated radiometric system (BACTEC, Johnston Laboratories) for detection of bacteremia was evaluated in parallel with a standard blood culture system in use in our laboratory. Of 1,445 blood cultures from 484 patients with possible bacteremia, 106 sets of cultures (excluding 39 presumed contaminated), representing 56 patients, were positive by both methods. The conventional system yielded 85 positive cultures from 48 patients, whereas the BACTEC system yielded 84 positive cultures from 43 patients. The BACTEC system failed to detect 22 cultures that were positive in the conventional system, and the conventional system failed to detect 21 cultures that were positive in the BACTEC system. The detection efficiency was generally equivalent in the two systems except for the lower detection rates of anaerobes and Enterobacter aerogenes by the BACTEC system and the lower detection rates of Torulopsis glabrata and, possibly, Pseudomonas sp. (group IVD) in the conventional system. The BACTEC system had a slight advantage over the conventional system in the time interval to detection of positivity. Approximately 20% of the positive cultures detected by the BACTEC system were detected on the first day of incubation compared with 7% by the conventional system. The recovery rates and detection times of anaerobes were less efficient by the BACTEC system than by the conventional system. It does not appear that the radiometric method has much advantage over available conventional methods.  相似文献   

14.
In order to evaluate the Organon Teknika MB/BacT system used for testing indirect susceptibility to the alternative drugs ofloxacin (OFLO), amikacin (AMI), and rifabutin (RIF), and to the usual drugs of standard treatment regimes such as rifampin (RMP), isoniazid (INH), pyrazinamide (PZA), streptomycin (SM), ethambutol (EMB), and ethionamide (ETH), cultures of clinical specimens from 117 patients with pulmonary tuberculosis under multidrug-resistant investigation, admitted sequentially for examination from 2001 to 2002, were studied. Fifty of the Mycobacterium tuberculosis cultures were inoculated into the gold-standard BACTEC 460 TB (Becton Dickinson) for studying resistance to AMI, RIF, and OFLO, and the remaining 67 were inoculated into Lowenstein Jensen (LJ) medium (the gold standard currently used in Brazil) for studying resistance to RMP, INH, PZA, SM, EMB, and ETH. We observed 100% sensitivity for AMI (80.8-100), RIF (80.8-100), and OFLO (78.1-100); and 100% specificity for AMI (85.4-100), RIF (85.4-100), and OFLO (86.7-100) compared to the BACTEC system. Comparing the results obtained in LJ we observed 100% sensitivity for RMP (80-100), followed by INH-95% (81.8-99.1), EMB-94.7% (71.9-99.7), and 100% specificity for all drugs tested except for PZA-98.3 (89.5-99.9) at 95% confidence interval. The results showed a high level of accuracy and demonstrated that the fully automated, non-radiometric MB/BacT system is indicated for routine use in susceptibility testing in public health laboratories.  相似文献   

15.
目的评价全自动血培养仪BacT/Aler3D的临床应用情况。方法对BacT/Aler3D全自动血培养仪检测的1853份标本,其检出的阳性率、病原菌种类及阳性检出时间进行了评估。结果1853份血培养分离出病原菌189株,阳性率为10.2%,分离出病原菌23种,最快检出时间为2h,24h以内阳性率为68.5%,48h内阳性率为87.3%,72h以内阳性率为92.3%。结论BacT/Aler3D全自动血培养仪提高血培养的阳性率,检出的细菌种类多,污染机会少,缩短阳性检出时间,而且操作简便,结果快速、准确。  相似文献   

16.
《Cytotherapy》2022,24(3):320-333
BackgroundAutomated growth-based methods for sterility testing of cell-therapy products should be qualified to demonstrate that they are equivalent to, or better than, the conventional reference method. The aim of the present study was to assess the ability of the BACTEC FX40 system to detect low microbial contamination and to confirm the suitability of the method in the presence of seven different human mesenchymal cell–based products, according to Ph. Eur. 2.6.27. Additionally, a study to select the best vial to detect fungus contamination was performed.MethodsMicroorganisms representing Gram-negative, Gram-positive, aerobic, anaerobic, spore-forming, slow-growing bacteria, yeast and mold were prepared in either Dulbecco's PBS or seven biological matrices containing approximately 5, 10, and 15 colony-forming units (CFU) per sample. These preparations were inoculated to the specific media required for each test method: (i) BACTEC aerobic and anaerobic vials; (ii) aerobic and anaerobic media for direct inoculation; and (iii) Trypcase soy 3P or Brucella blood agar plates. Colonies from cultures were identified using MALDI-TOF mass spectrometry.ResultsThe BACTEC FX40 system, in both Dulbecco's PBS and the biological matrices with a 5-CFU inoculum, detected most of the microorganisms significantly faster than the conventional method, despite the presence of a matrix containing gentamicin and several matrices containing 10% DMSO. Conversely, it showed an extremely delayed detection of Candida albicans compared with the conventional method. The addition of a Mycosis IC/F (MYC) vial decreased radically the time to detection (TTD) of C. albicans (28.2 ± 1.8 h) compared with the conventional method (36 h).ConclusionsWhen a MYC vial was added to the standard aerobic and anaerobic vials to test each sample, BACTEC FX40 was shown to be a superior alternative sterility method for cell-therapy products contaminated with low inocula, with a faster TTD for microbial growth compared with the conventional method (5 versus 14 days). The studies were carried out in different cell-based matrices with sensitivities and specificities of 100% for all the tested strains at 15-, 10- and 5-CFU inoculum, with the exception of Kocuria rhizophila at 5 CFU (90.48% sensitivity and 100% specificity).  相似文献   

17.
Cell therapy products represent a new trend of treatment in the field of immunotherapy and regenerative medicine. Their biological nature and multistep preparation procedure require the application of complex release criteria and quality control. Microbial contamination of cell therapy products is a potential source of morbidity in recipients. The automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However the standard 2-week cultivation period is too long for some cell-based treatments and alternative methods have to be devised. We tried to verify whether a shortened cultivation of the supernatant from the mesenchymal stem cell (MSC) culture obtained 2 days before the cell harvest could sufficiently detect microbial growth and allow the release of MSC for clinical application. We compared the standard Ph. Eur. cultivation method and the automated blood culture system BACTEC (Becton Dickinson). The time to detection (TTD) and the detection limit were analyzed for three bacterial and two fungal strains. The Staphylococcus aureus and Pseudomonas aeruginosa were recognized within 24 h with both methods (detection limit ~10 CFU). The time required for the detection of Bacillus subtilis was shorter with the automated method (TTD 10.3 vs. 60 h for 10–100 CFU). The BACTEC system reached significantly shorter times to the detection of Candida albicans and Aspergillus brasiliensis growth compared to the classical method (15.5 vs. 48 and 31.5 vs. 48 h, respectively; 10–100 CFU). The positivity was demonstrated within 48 h in all bottles, regardless of the size of the inoculum. This study validated the automated cultivation system as a method able to detect all tested microorganisms within a 48-h period with a detection limit of ~10 CFU. Only in case of B. subtilis, the lowest inoculum (~10 CFU) was not recognized. The 2-day cultivation technique is then capable of confirming the microbiological safety of MSC and allows their timely release for clinical application.  相似文献   

18.
目的分析本院80~100岁高龄患者血液感染常见革兰阴性杆菌的种类及其耐药状况,为本院合理使用抗生素提供依据。方法采用BacT/Alert 3D血培养仪对血液标本进行阳性鉴定;VITEK-2Compact全自动微生物鉴定仪进行鉴定;K-B纸片扩散法对抗菌药物进行敏感性测定;使用WHONET 5.4分析软件分析数据。结果本院高龄患者血液培养阳性标本中共分离出革兰阴性杆菌108株,以肠杆菌科细菌为主,其次为非发酵菌,前者主要为大肠埃希菌52株(48.15%)和肺炎克雷伯菌37株(34.26%),后者主要包括铜绿假单胞菌10株(9.26%)和鲍曼不动杆菌8株(7.41%)。其中大肠埃希菌和肺炎克雷伯菌对亚胺培南的耐药率分别为1.92%和13.51%,两者对氨苄西林、氨苄西林/舒巴坦、头孢唑林、头孢呋辛的耐药率均高于50.00%;铜绿假单胞菌和鲍曼不动杆菌对亚胺培南的耐药率分别为20.00%和25.00%,后者对其他抗菌药物的耐药率均高于前者。结论碳青酶烯类抗生素可作为本院高龄患者常见革兰阴性杆菌所致血液感染的首选药物;但在治疗中应考虑细菌的耐药特点及患者的代谢特点合理选择抗生素。  相似文献   

19.
In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35 degrees C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 micro g/ml, Isoniazid - 0.2 micro g/ml, Pyrazinamide - 100 micro g/ml, Ethambutol - 2.5 micro g/ml, Ethionamide - 1.25 micro g/ml, and Streptomycin - 2 micro g/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.  相似文献   

20.
AIMS: To compare the detection capabilities of the non-radiometric MGIT (Mycobacteria Growth Indicator Tubes) and radiometric BACTEC 460TB culture systems (Becton Dickinson, Cowley, Oxford, UK) for recovering Mycobacterium avium subsp. paratuberculosis from milk. METHODS AND RESULTS: Ultra heat treated (UHT) milk samples spiked with different levels of M. paratuberculosis (10-107 cells ml-1) were inoculated into MGIT and BACTEC media (containing recommended supplements) with and without prior chemical decontamination of the milk samples with 0.75% (w/v) cetylpyridinium chloride for 5 h. Time for the detection of growth in days was recorded for each culture system, and a M. paratuberculosis count for each milk sample was calculated from BACTEC readings using a published formula. Correlation between MGIT and BACTEC detection times was 0.6983. Both culture systems were capable of detecting 10-100 M. paratuberculosis cells ml-1 in milk within 30-40 days when no decontamination treatment was applied, but only 102-103 cells ml-1 or greater when chemical decontamination was applied before culture. CONCLUSIONS, SIGNIFICANCE AND IMPACT OF STUDY: The non-radiometric MGIT system could be substituted for the radiometric BACTEC system for the culture of M. paratuberculosis from milk without loss of detection sensitivity. Chemical decontamination before culture caused a significant reduction in numbers of viable M. paratuberculosis in all spiked milk samples resulting in decreased detection capability for both culture systems.  相似文献   