1.
When the inner cylinder of a fluid-filled Couette viscometer is rotated rapidly, a vortical flow pattern develops when a dimensionless value referred to as the critical Taylor number (Tc) is reached. We have determined its magnitude in our viscometer for three Newtonian fluids and for blood at 37 degrees C, using the inflection point of torque/RPM vs. RPM (sudden rise in apparent viscosity). Its position was identified by least squares line fitting. Because blood was studied, the viscosity used in Tc calculation was the apparent bob shear stress/shear rate ratio at the inflection marking vortical flow onset. For glycerol-water mixtures Tc was 41.8 +/- 0.3 (N = 11), for propylene glycol 42.0 +/- 0.2 (N = 14), for silicone oil 41.8 +/- 0.2 (N = 11). For healthy blood Tc was 40.7 +/- 0.9 (N = 140). This evidence against blood's increased resistance to flow instability was accompanied by a slower rate of rise in torque both above and below Tc compared to the three Newtonian fluids. Newtonian fluids and blood both developed wavy vortical flow at a rotation rate moderately higher than Tc. Blood resisted this unstable flow behavior more than the Newtonian fluids but it also experienced a slower rate of rise in torque with increasing rotation rate above the critical Taylor number. Shear-thinning is the simplest explanation for blood's mildly altered Taylor vortex behavior; blood's resistance to flow instability is otherwise not found to be sufficient to affect its flow stability in man.  相似文献   

2.
Laser Doppler anemometry experiments and finite element simulations of steady flow in a three dimensional model of the carotid bifurcation were performed to investigate the influence of non-Newtonian properties of blood on the velocity distribution. The axial velocity distribution was measured for two fluids: a non-Newtonian blood analog fluid and a Newtonian reference fluid. Striking differences between the measured flow fields were found. The axial velocity field of the non-Newtonian fluid was flattened, had lower velocity gradients at the divider wall, and higher velocity gradients at the non-divider wall. The flow separation, as found with the Newtonian fluid, was absent. In the computations, the shear thinning behavior of the analog blood fluid was incorporated through the Carreau-Yasuda model. The viscoelastic properties of the fluid were not included. A comparison between the experimental and numerical results showed good agreement, both for the Newtonian and the non-Newtonian fluid. Since only shear thinning was included, this seems to be the dominant non-Newtonian property of the blood analog fluid under steady flow conditions.  相似文献   

3.
D Liepsch  S Moravec 《Biorheology》1984,21(4):571-586
In addition to biochemical factors, hydromechanical influences are responsible for atherogenesis and deposits of blood platelets at bends and bifurcations of human arteries. Hence the flow patterns were simulated in a true-to-scale three-dimensional bifurcation of a human renal artery model and of an arterial femoralis with Newtonian and non-Newtonian blood like fluid. Investigations were made with steady and pulsatile flow. The velocity profiles (at physiological Re-numbers) were measured after the bifurcations with a laser-Doppler-anemometer. In previous works Newtonian fluids were used to investigate the flow in bends and bifurcations of rigid and elastic simplified models. In this paper, emphasis is placed on the difference between rigid and elastic models and also Newtonian and non Newtonian flow behavior. Differences between Newtonian and non Newtonian fluids may especially be expected to occur after branches where the flow has local strong convective elements such as in reverse zones and flow separation points.  相似文献   

4.
In this paper, the heat transfer effect on the unsteady boundary layer flow of a Casson fluid past an infinite oscillating vertical plate with Newtonian heating is investigated. The governing equations are transformed to a systems of linear partial differential equations using appropriate non-dimensional variables. The resulting equations are solved analytically by using the Laplace transform method and the expressions for velocity and temperature are obtained. They satisfy all imposed initial and boundary conditions and reduce to some well-known solutions for Newtonian fluids. Numerical results for velocity, temperature, skin friction and Nusselt number are shown in various graphs and discussed for embedded flow parameters. It is found that velocity decreases as Casson parameters increases and thermal boundary layer thickness increases with increasing Newtonian heating parameter.  相似文献   

5.
A steady laminar flow of blood in a uniform tapered tube has been examined. Blood rheology is assumed to be described by a polar fluid. The analytical expressions for velocities (both axial and radial), total angular velocity, wall shear and pressure drop have been obtained. In literature, the parameters N (coupling number) and L (length ratio) have been chosen independently. But, in the present analysis, it is found that they are interrelated. Variation of the flow variables with suspension concentration and tapered angle have been investigated. Some of the theoretical models for the flow through tapered tubes have been critically examined. The pressure-flow relationship has been studied numerically over the flow rate range 0.01-0.1 cc/sec and compared with experimental results. It has been shown that the existing experimental results are for the tapered tubes of larger diameter which correspond to the flow under Newtonian conditions. Finally, some biological implications and future developments of this theory have been indicated.  相似文献   

6.
The fluid dynamic behavior of a Newtonian water/glycerol solution, a non-Newtonian polymer (separan) solution, and bovine blood were compared in the Penn State Electrical Ventricular Assist Device (EVAD). Pulsed doppler ultrasound velocimetry was used to measure velocities in the near wall region (0.95-2.7 mm) along the perimeter of the pump. Mean velocity, turbulence intensity, local and convective acceleration, and shear rate were calculated from the PDU velocity measurements. Flow visualization provided qualitative information about the general flow patterns in the EVAD. Results indicate that water/glycerol does not accurately model the flow characteristics of bovine blood in the EVAD. The non-Newtonian separan solution produced results closer to those of the bovine blood than did the water/glycerol solution. Near wall velocity magnitudes for the separan were similar to those of the bovine blood, but the profile shapes differed for portions of the pump cycle. All three fluids exhibited periods of stagnation. Bovine blood results indicated the presence of a desired rotational washout pattern at midsystole, while results with the other fluids did not show this feature.  相似文献   

7.
Chen J  Lu XY 《Journal of biomechanics》2004,37(12):1899-1911
The non-Newtonian fluid flow in a bifurcation model with a non-planar daughter branch is investigated by using finite element method to solve the three-dimensional Navier–Stokes equations coupled with a non-Newtonian constitutive model, in which the shear thinning behavior of the blood fluid is incorporated by the Carreau–Yasuda model. The objective of this study is to investigate the influence of the non-Newtonian property of fluid as well as of curvature and out-of-plane geometry in the non-planar daughter vessel on wall shear stress (WSS) and flow phenomena. In the non-planar daughter vessel, the flows are typified by the skewing of the velocity profile towards the outer wall, creating a relatively low WSS at the inner wall. In the downstream of the bifurcation, the velocity profiles are shifted towards the flow divider. The low WSS is found at the inner walls of the curvature and the lateral walls of the bifurcation. Secondary flow patterns that swirl fluid from the inner wall of curvature to the outer wall in the middle of the vessel are also well documented for the curved and bifurcating vessels. The numerical results for the non-Newtonian fluid and the Newtonian fluid with original Reynolds number and the corresponding rescaled Reynolds number are presented. Significant difference between the non-Newtonian flow and the Newtonian flow is revealed; however, reasonable agreement between the non-Newtonian flow and the rescaled Newtonian flow is found. Results of this study support the view that the non-planarity of blood vessels and the non-Newtonian properties of blood are an important factor in hemodynamics and may play a significant role in vascular biology and pathophysiology.  相似文献   

8.
S Nandy  J M Tarbell 《Biorheology》1987,24(5):483-500
Wall shear stress has been measured by flush-mounted hot film anemometry distal to an Ionescu-Shiley tri-leaflet valve under pulsatile flow conditions. Both Newtonian (aqueous glycerol) and non-Newtonian (aqueous polyacrylamide) blood analog fluids were investigated. Significant differences in the axial distribution of wall shear stress between the two fluids are apparent in flows having nearly identical Reynolds numbers. The Newtonian fluid exhibits a (peak) wall shear rate which is maximized near the valve seat (30 mm) and then decays to a fully developed flow value (by 106 mm). In contrast, the shear rate of the non-Newtonian fluid at 30 mm is less than half that of the Newtonian fluid and at 106 mm is more than twice that of the Newtonian fluid. It is suggested that non-Newtonian rheology influences valve flow patterns either through alterations in valve opening associated with low shear separation zones behind valve leaflets, or because of variations in the rate of jet spreading. More detailed studies are required to clarify the mechanisms. The Newtonian wall shear stresses for this valve are low. The highest value observed anywhere in the aortic chamber was 2.85 N/m2 at a peak Reynolds number of 3694.  相似文献   

9.
A numerical and experimental investigation of unsteady entry flow in a 90 degrees curved tube is presented to study the impact of the non-Newtonian properties of blood on the velocity distribution. The time-dependent flow rate for the Newtonian and the non-Newtonian blood analog fluid were identical. For the numerical computation, a Carreau-Yasuda model was employed to accommodate the shear thinning behavior of the Xanthan gum solution. The viscoelastic properties were not taken into account. The experimental results indicate that significant differences between the Newtonian and non-Newtonian fluid are present. The numerical results for both the Newtonian and the non-Newtonian fluid agree well with the experimental results. Since viscoelasticity was not included in the numerical code, shear thinning behavior of the blood analog fluid seems to be the dominant non-Newtonian property, even under unsteady flow conditions. Finally, a comparison between the non-Newtonian fluid model and a Newtonian fluid at a rescaled Reynolds number is presented. The rescaled Reynolds number, based on a characteristic rather than the high-shear rate viscosity of the Xanthan gum solution, was about three times as low as the original Reynolds number. Comparison reveals that the character of flow of the non-Newtonian fluid is simulated quite well by using the appropriate Reynolds number.  相似文献   

10.
Choi HW  Barakat AI 《Biorheology》2005,42(6):493-509
Endothelial cell (EC) responsiveness to shear stress is essential for vasoregulation and plays a role in atherogenesis. Although blood is a non-Newtonian fluid, EC flow studies in vitro are typically performed using Newtonian fluids. The goal of the present study was to determine the impact of non-Newtonian behavior on the flow field within a model flow chamber capable of producing flow disturbance and whose dimensions permit Reynolds and Womersley numbers comparable to those present in vivo. We performed two-dimensional computational fluid dynamic simulations of steady and pulsatile laminar flow of Newtonian and non-Newtonian fluids over a backward facing step. In the non-Newtonian simulations, the fluid was modeled as a shear-thinning Carreau fluid. Steady flow results demonstrate that for Re in the range 50-400, the flow recirculation zone downstream of the step is 22-63% larger for the Newtonian fluid than for the non-Newtonian fluid, while spatial gradients of shear stress are larger for the non-Newtonian fluid. In pulsatile flow, the temporal gradients of shear stress within the flow recirculation zone are significantly larger for the Newtonian fluid than for the non-Newtonian fluid. These findings raise the possibility that in regions of flow disturbance, EC mechanotransduction pathways stimulated by Newtonian and non-Newtonian fluids may be different.  相似文献   

11.
This paper presents Computational fluid dynamic (CFD) analysis of blood flow in three different 3-D models of left coronary artery (LCA). A comparative study of flow parameters (pressure distribution, velocity distribution and wall shear stress) in each of the models is done for a non-Newtonian (Carreau) as well as the Newtonian nature of blood viscosity over a complete cardiac cycle. The difference between these two types of behavior of blood is studied for both transient and steady states of flow. Additionally, flow parameters are compared for steady and transient boundary conditions considering blood as non-Newtonian fluid. The study shows that the highest wall shear stress (WSS), velocity and pressure are found in artery having stenosis in all the three branches of LCA. The use of Newtonian blood model is a good approximation for steady as well as transient blood flow boundary conditions if shear rate is above 100 s-1. However, the assumption of steady blood flow results in underestimating the values of flow parameters such as wall shear stress, pressure and velocity.  相似文献   

12.
Endovascular coiling aims to isolate the aneurysm from blood circulation by altering hemodynamics inside the aneurysm and triggering blood coagulation. Computational fluid dynamics (CFD) techniques have the potential to predict the post-operative hemodynamics and to investigate the complex interaction between blood flow and coils. The purpose of this work is to study the influence of blood viscosity on hemodynamics in coiled aneurysms. Three image-based aneurysm models were used. Each case was virtually coiled with a packing density of around 30%. CFD simulations were performed in coiled and untreated aneurysm geometries using a Newtonian and a Non-Newtonian fluid models. Newtonian fluid slightly overestimates the intra-aneurysmal velocity inside the aneurysm before and after coiling. There were numerical differences between fluid models on velocity magnitudes in coiled simulations. Moreover, the non-Newtonian fluid model produces high viscosity (>0.007>0.007 [Pa s]) at aneurysm fundus after coiling. Nonetheless, these local differences and high-viscous regions were not sufficient to alter the main flow patterns and velocity magnitudes before and after coiling. To evaluate the influence of coiling on intra-aneurysmal hemodynamics, the assumption of a Newtonian fluid can be used.  相似文献   

13.
The fundamental study of blood flow past a circular cylinder filled with an oxygen source is investigated as a building block for an artificial lung. The Casson constitutive equation is used to describe the shear-thinning and yield stress properties of blood. The presence of hemoglobin is also considered. Far from the cylinder, a pulsatile blood flow in the x direction is prescribed, represented by a time periodic (sinusoidal) component superimposed on a steady velocity. The dimensionless parameters of interest for the characterization of the flow and transport are the steady Reynolds number (Re), Womersley parameter (alpha), pulsation amplitude (A), and the Schmidt number (Sc). The Hill equation is used to describe the saturation curve of hemoglobin with oxygen. Two different feed-gas mixtures were considered: pure O(2) and air. The flow and concentration fields were computed for Re=5, 10, and 40, 0< or =A< or =0.75, alpha=0.25, 0.4, and Schmidt number, Sc=1000. The Casson fluid properties result in reduced recirculations (when present) downstream of the cylinder as compared to a Newtonian fluid. These vortices oscillate in size and strength as A and alpha are varied. Hemoglobin enhances mass transport and is especially important for an air feed which is dominated by oxyhemoglobin dispersion near the cylinder. For a pure O(2) feed, oxygen transport in the plasma dominates near the cylinder. Maximum oxygen transport is achieved by operating near steady flow (small A) for both feed-gas mixtures. The time averaged Sherwood number, Sh, is found to be largely influenced by the steady Reynolds number, increasing as Re increases and decreasing with A. Little change is observed with varying alpha for the ranges investigated. The effect of pulsatility on Sh is greater at larger Re. Increasing Re aids transport, but yields a higher cylinder drag force and shear stresses on the cylinder surface which are potentially undesirable.  相似文献   

14.
Pulsatile flow in an axisymmetric rigid-walled model of an abdominal aorta aneurysm was analyzed numerically for various aneurysm dilations using physiologically realistic resting waveform at time-averaged Reynolds number of 300 and peak Reynolds number of 1607. Discretization of the governing equations was achieved using a finite element scheme based on the Galerkin method of weighted residuals. Comparisons with previously published work on the basis of special cases were performed and found to be in excellent agreement. Our findings indicate that the velocity fields are significantly affected by non-Newtonian properties in pathologically altered configurations. Non-Newtonian fluid shear stress is found to be greater than Newtonian fluid shear stress during peak systole. Further, the maximum shear stress is found to occur near the distal end of AAA during peak systole. The impact of non-Newtonian blood flow characteristics on pressure compared to Newtonian model is found insignificant under resting conditions. Viscous and inertial forces associated with blood flow are responsible for the changes in the wall that result in thrombus deposition and dilation while rupture of AAA is more likely determined by much larger mechanical stresses imposed by pulsatile pressure on the wall of AAA.  相似文献   

15.
The effects of polar nature of blood and pulsatility on flow through a stenosed tube have been analysed by assuming blood as a micropolar fluid. Linearized solutions of basic equations are obtained through consecutive applications of finite Hankel and Laplace transforms. The analytical expressions for axial and particle angular velocities, wall shear stress, resistance to flow and apparent viscosity have been obtained. The axial velocity profiles for Newtonian and micropolar fluids have been compared. The interesting observation of this analysis is velocity, in certain parts of cycle, for micropolar fluid is higher than Newtonain fluid. Variation of apparent viscosity eta a with tube radius shows both inverse Fahraeus-Lindqvist and Fahraeus-Lindqvist effects. Finally, the resistance to flow and wall shear stress for normal and diseased blood have been computed and compared.  相似文献   

16.
S Moravec  D Liepsch 《Biorheology》1983,20(6):745-759
Together with biochemical factors, fluid mechanical factors play a role in atherogenesis and the deposition of blood platelets at bends and bifurcations in human arteries. Hence, flow patterns were investigated in a simplified 3-dimensional model of a human renal artery bifurcation using Newtonian (aqueous glycerol) and non-Newtonian (aqueous solution of polyacrylamide) fluids. Studies were carried out in steady as well as pulsatile flow at inflow Reynolds numbers of 498 and 951 with flow rate ratios main tube V1: right branch V4: left branch V3 of 1: 0.25: 0.25 and 1: 0.18: 0.18 respectively. The velocity distribution proximal and distal to the bifurcations was measured using a laser-Doppler anemometer. In steady flow, zones of flow separation and reverse flow were observed distal to the bifurcations. In pulsatile flow using non-Newtonian fluids, there was a significant enlargement of these zones. Differences between the Newtonian and non-Newtonian fluids occurred especially distal to the bifurcations. Shear stresses along all measuring positions were computed from the velocity gradients.  相似文献   

17.
D Liepsch  G Thurston  M Lee 《Biorheology》1991,28(1-2):39-52
We studied several non-Newtonian fluids to determine how closely they simulate the flow behavior of human blood. The viscous and viscoelastic properties of these fluids were compared with human blood samples in steady flow and transient flow Couette viscometers and in an oscillatory tube flow viscoelasticity analyzer. We examined: 1) A polyacrylamide suspension (Separan AP30 and AP45) to which we added 4% isopropanol and 0.01% magnesium chloride. 2) A suspension of 2% Dextran with 16% by weight biconcave disc-shaped particles simulating red blood cells. 3) 40% ghost cells prepared according to Dodge in Tri (hydroxymethyl) aminomethane. These ghost cells were used to simulate the two-phase flow behavior of blood. 4) A suspension of 5% Dextran (70,000) with 12% polystyrene particles (diameter of 1 micron) and 10 mMol calcium chloride. All these fluids closely approximate the flow behavior of blood and can be used in a variety of different experimental situations. To measure velocity distribution using a laser-Doppler-anemometer, we used fluids #1 and #3 in a rigid T-junction simulating the first septal branch of the left descending coronary artery. The measurements were done in steady and pulsatile flow experiments at different flow rate ratios. The fluids showed large differences in velocity profiles compared to Newtonian fluids.  相似文献   

18.
Magnetic field influence on unsteady free convection flow of a second grade fluid near an infinite vertical flat plate with ramped wall temperature embedded in a porous medium is studied. It has been observed that magnitude of velocity as well as skin friction in case of ramped temperature is quite less than the isothermal temperature. Some special cases namely: (i) second grade fluid in the absence of magnetic field and porous medium and (ii) Newtonian fluid in the presence of magnetic field and porous medium, performing the same motion are obtained. Finally, the influence of various parameters is graphically shown.  相似文献   

19.
A two-fluid model for blood flow through a stenosed tube has been developed. The model consists of a core (suspension of RBCs) and peripheral plasma layer. The core is assumed to be represented by a polar fluid and the plasma layer by a Newtonian fluid. The flow is assumed to be steady and laminar, and the fluids incompressible. The flow variables are computed for normal blood and for the cases of polycythemia, plasma cell dyscrasias and for Hb SS diseases. Resistance to flow has been computed for different stenosis length and for different stenosis height. Shear stress distribution along the axial distance has been computed for different stenosis height. The impact of size effects (particle size to tube diameter) on blood diseases is discussed.  相似文献   

20.
D N Ku  D Liepsch 《Biorheology》1986,23(4):359-370
To study the fundamentals of hemodynamics in arteries, the flow parameters: pulsatility, elasticity and non-Newtonian viscoelasticity were considered in detail in a 90 degrees-T-bifurcation of a rigid and elastic model. The velocity distribution 2.5 mm behind the bifurcation in the straight tube was measured with a laser-Doppler-anemometer. The fluid used was an aqueous glycerine solution and a viscoelastic Separan mixture. Flow visualization studies were done with a sheet of laser light in the plane of the bifurcation. The velocity distribution was measured for both steady and pulsatile flows with a laser-Doppler-anemometer in a backward scattered way. From the velocity measurements the shear gradients were calculated. Substantial differences were found in the flow behavior of Newtonian and non-Newtonian fluids, especially behind the bifurcation in the main tube, where secondary flows and flow separation started. Also, differences due to the elastic and rigid wall could be seen. Very high shear gradients were found in the flow between main flow and the separation zone which can lead to a damage of the blood cells.  相似文献   