首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

2.
Most current assays of HDL functional properties are cell-based. We have developed a fluorometric biochemical assay based on the oxidation of dihydrorhodamine 123 (DHR) by HDL. This cell-free assay assesses the intrinsic ability of HDL to be oxidized by measuring increasing fluorescence due to DHR oxidation over time. The assay distinguishes the oxidative potential of HDL taken from different persons, and the results are reproducible. Direct comparison of this measurement correlated well with results obtained using a validated cell-based assay (r(2) = 0.62, P < 0.001). The assay can be scaled from a 96-well format to a 384-well format and, therefore, is suitable for high-throughput implementation. This new fluorometric method offers an inexpensive, accurate, and rapid means for determining the oxidative properties of HDL that is applicable to large-scale clinical studies.  相似文献   

3.
4.
5.
The miniaturization of gene transfer assays to either 384- or 1536-well plates greatly economizes the expense and allows much higher throughput when transfecting immortalized and primary cells compared with more conventional 96-well assays. To validate the approach, luciferase and green fluorescent protein (GFP) reporter gene transfer assays were developed to determine the influence of cell seeding number, transfection reagent to DNA ratios, transfection time, DNA dose, and luciferin dose on linearity and sensitivity. HepG2, CHO, and NIH 3T3 cells were transfected with polyethylenimine (PEI)–DNA in both 384- and 1536-well plates. The results established optimal transfection parameters in 384-well plates in a total assay volume of 35 μl and in 1536-well plates in a total assay volume of 8 μl. A luciferase assay performed in 384-well plates produced a Z′ score of 0.53, making it acceptable for high-throughput screening. Primary hepatocytes were harvested from mouse liver and transfected with PEI DNA and calcium phosphate DNA nanoparticles in 384-well plates. Optimal transfection of primary hepatocytes was achieved on as few as 250 cells per well in 384-well plates, with CaPO4 proving to be 10-fold more potent than PEI.  相似文献   

6.
p56(lck) is a lymphocyte-specific tyrosine kinase that plays an important role in both T-cell maturation and activation. We have developed a homogeneous assay in which p56(lck) catalyzes the transfer of the gamma-phosphate group from [gamma-(33)P]ATP to a biotinylated peptide substrate. The labeled peptide is then captured on a streptavidin-coated scintillation proximity assay (SPA) bead or imaging proximity bead. The SPA is counted in a microplate scintillation counter and the imaging proximity assay is counted in a charge-coupled device-based imaging system called LEADseekertrade mark, recently launched as a homogeneous imaging system by Amersham Pharmacia Biotech. We show, via time-dependence assays and inhibitor studies, that this assay can be performed in 1536-well microplate format using imaging proximity as the method of detection. The results compare favorably with the same assay performed in 384-well microplate format using both SPA and imaging proximity as the detection methods. From this study, we conclude that a kinase assay can be performed in 384- and 1536-well format using imaging as the detection method, with significant time savings over standard scintillation counting. In addition, we show cost saving advantages of 1536- over 384-well format in terms of reagent usage, higher throughput, and waste disposal.  相似文献   

7.
8.
Fluorescence polarization (FP) is an established technique for the study of biological interactions and is frequently used in the high-throughput screening (HTS) of potential new drug targets. This work describes the miniaturization of FP receptor assays to 1536-well formats for use in HTS. The FP assays were initially developed in 384-well microplates using CyDye-labeled nonpeptide and peptide ligands. Receptor expression levels varied from approximately 1 to 10 pmols receptor per mg protein, and ligand concentrations were in the 0.5- to 1.0-nM range. The FP assays were successfully miniaturized to 1536-well formats using Cy3B-labeled ligands, significantly reducing reagent consumption, particularly the receptor source, without compromising assay reliability. Z' factor values determined for the FP receptor assays in both 384- and 1536-well formats were found to be > 0.5, indicating the assays to be robust, reliable, and suitable for HTS purposes.  相似文献   

9.
Miniaturization of high-throughput screening (HTS) assays has several obvious advantages, including increased throughput and lower cost by reduction in reagent consumption. Although absorbance assays are widely used in research laboratories, their application for HTS in a low-volume format has been met with mixed success because they are difficult to miniaturize. Challenges for the miniaturization of absorbance assays include low signal due to short path lengths and meniscus distortions in small well sizes. Here we describe a method to miniaturize absorbance assays to standard, white, low-volume 384-well and 1536-well microplates using a fluorometric plate reader for detection. The premise of this absorbance assay is based on the fluorescent properties of white microplates and the ability of a colored product to quench the fluorescence signal from the plate by absorbing either the excitation light or the emission light. This method was applied to the detection of inorganic phosphate using Quinaldine red and Malachite green dyes and to the monitoring of alkaline phosphatase hydrolysis of p-nitrophenyl phosphate. These assays can be carried out in low volumes, give robust screening statistics, and can be accomplished with a simple, inexpensive fluorometric plate reader.  相似文献   

10.
The 1,536-well microplate format has widely supplanted the 384-well microplate format for high-throughput screening and for IC(50) assays. Previously, liquid chromatography/mass spectrometry (LC/MS) analyses of such samples required manual transfers of the wells of interest from a 1,536-well plate into a 384-well plate. Because this manual transfer introduced a source of potential error, it became clear that a more appropriate solution would be to sample directly from the 1,536-well plates. Currently, commercially available 1,536-well plate auto samplers are not compatible with Waters LC/MS systems. The authors have modified their CTC PAL autosampler to support injection from up to twenty-four 1,536-well plates. This allows them to cherry-pick any sample from up to 36,864 wells on the autosampler. Because of its success at this Institute, sampling from 1,536-well plates has not only become the preferred method for LC/MS analysis from IC(50) plates but also become the standard format used for the handling of and the sampling from large combinatorial libraries.  相似文献   

11.
We have developed a simple, homogeneous bead-based immunoassay for use with fluorometric microvolume assay technology (FMAT). The FLISA (fluorescence-linked immunosorbent assay) can be easily adapted from existing immunoassays, is comparable to traditional ELISAs with respect to linear dynamic range and sensitivity, and can be readily performed in 96- and 384-well plates. Additionally, the FLISA utilizes 100-fold less primary antibody than the conventional immunoassay. The scanner uses a helium/neon laser to image and measure bead-bound fluorescence while the background fluorescence is ignored. Consequently, no wash steps are required to remove unbound antibody, ligand, and fluorophore. Furthermore, the instrument is capable of detecting two different fluorescent dyes, allowing for multiplexed assays based on color. Fluorescent bead-based immunoassays were developed for the cytokines IL-6 and IL-8, and their use in both one-color and two-color FLISAs is demonstrated. Although no wash steps were employed, the FLISA was able to accurately measure the concentrations of IL-6 and IL-8 in the growth media of cytokine-stimulated HUVEC cells. In addition, a simulated high-throughput two-color FLISA positively identified those wells in a 384-well plate that contained different amounts of IL-6 and/or IL-8 peptide. The homogeneous, multiplex and multiplate format of the FLISA reduces hands-on time and reagent usage, and is therefore ideally suited for high-throughput screening.  相似文献   

12.
Although fluorescence imaging plate reader (FLIPR)-based assays have been widely used in high-throughput screening, improved efficiencies in throughput and fidelity continue to be investigated. This study presents an offline compound addition protocol coupled with a testing strategy using mixtures of compounds in a 384-well format to identify antagonists of the neurokinin-1 receptor expressed in the human astrocytoma cell line (U373 MG). Substance P evoked a concentration-dependent increase in intracellular cellular Ca(2+) with an EC(50) value of 0.30 +/- 0.17 nM, which was inhibited by neurokinin-1 (NK1) antagonists L-733,060 and L-703,606. Test compounds, as mixtures of 10 compounds/well, were added to the cells offline using an automated dispensing unit and incubated prior to performing the assay in the FLIPR. Using the offline protocol, a higher through put of ~200,000 compounds was achieved in an 8-h working day, and several novel structural classes of compounds were identified as antagonists for the NK1 receptor. These studies demonstrate that the offline compound addition format using a mixture of compounds in a 384-well FLIPR assay provides an efficient platform for screening and identifying modulators for G-protein-coupled receptors.  相似文献   

13.
Phosphatidylinositol 4-kinases (PI 4-kinases) catalyze the conversion of phosphatidylinositol to phosphatidylinositol 4-phosphate (PtdIns4P). The four known mammalian PI 4-kinases, PI4KA, PI4KB, PI4K2A, and PI4K2B have roles in intracellular lipid and protein trafficking. PI4KA and PI4KB also assist in the replication of several positive-sense RNA viruses. The identification of selective inhibitors of these kinases would be facilitated by assays suitable for high-throughput screening. We describe a homogeneous and nonisotopic assay for PI 4-kinase activity based on the bioluminescent detection of the ADP produced by kinase reactions. We have evaluated this assay with known nonselective inhibitors of PI 4-kinases and show that it performs similar to radiometric assay formats previously described in the literature. In addition, this assay generates Z-factor values of >0.7 for PI4KA in a 384-well format, demonstrating its suitability for high-throughput screening applications.  相似文献   

14.
DNA helicases are responsible for the unwinding of double-stranded DNA, facilitated by the binding and hydrolysis of 5'-nucleoside triphosphates. These enzymes represent an important class of targets for the development of novel anti-infective agents particularly because opportunity exists for synergy with existing therapies targeted at other enzymes involved in DNA replication. Unwinding reactions are conventionally monitored by low throughput, gel-based radiochemical assays; to overcome the limitations of low throughput to achieve comprehensive characterization of adenosine triphosphate (ATP)-dependent unwinding by viral and bacterial helicases and the screening for unwinding inhibitors, we have developed and validated homogeneous time-resolved fluorescence energy transfer (TRET) assays. Rapid characterization and screening of DNA helicase has been performed in 96- and 384-well plate densities, and the ability to assay in 1536-well format also demonstrated. We have successfully validated and are running full high throughput runs using 384-well TRET helicase assays, culminating in the identification of a range of chemically diverse inhibitors of viral and bacterial helicases. For screening in mixtures, we used a combination of quench correction routines and confirmatory scintillation proximity (SP) assays to eliminate false-positives due to the relatively high levels of compound quenching (unlike other Ln(3+)-based assays). This strategy was successful yet emphasised the need for further improvements in helicase assays.  相似文献   

15.
To take advantage of the growing knowledge of cellular signaling pathways, modern-day drug discovery faces an increasing challenge to develop assays to screen for compounds that modulate protein-protein interactions. One bottleneck in achieving this goal is a lack of suitable and robust assay technologies amenable to a high-throughput format. In this report, we describe how we utilized Alphascreen trade mark technology to develop a high-throughput assay to monitor ligand binding to a member of the tumor necrosis factor receptor superfamily. We expressed a fusion protein consisting of the extracellular domain of the OX40 receptor with the constant domains of human IgG. In the presence of OX40 ligand, we determined a binding affinity constant consistent with reported values and optimized the protocol to develop a simple, homogeneous, and sensitive binding assay in a 384-well format. Finally, we assessed if this system could identify small peptides capable of inhibiting the OX40 receptor and ligand interaction. The results showed that the assay was able to detect such peptides and could be used to launch a high-throughput screening campaign for small molecules able to prevent OX40 receptor activation.  相似文献   

16.
Monoamine transporters regulate the concentration of neurotransmitters in the synapse following neurotransmission and are very important drug targets in the pharmaceutical industry. Because of the labor-intensive nature of functional uptake assays using radioactive substrates, high-throughput screening for monoamine transporter inhibitors has been limited to radioligand binding assays. In this article, the authors describe the development of a 384-well, high-throughput functional screening assay for norepinephrine transporter inhibitors using the FLIPR(Tetra) and a recently identified fluorescent substrate, 4-(4-dimethylaminostyryl)- N-methyl-pyridinium (ASP(+)).  相似文献   

17.
AequoScreen, a cellular aequorin-based functional assay, has been optimized for luminescent high-throughput screening (HTS) of G protein-coupled receptor (GPCRs). AequoScreen is a homogeneous assay in which the cells are loaded with the apoaequorin cofactor coelenterazine, diluted in assay buffer, and injected into plates containing the samples to be tested. A flash of light is emitted following the calcium increase resulting from the activation of the GPCR by the sample. Here we have validated a new plate reader, the Hamamatsu Photonics FDSS6000, for HTS in 96- and 384-well plates with CHO-K1 cells stably coexpressing mitochondrial apoaequorin and different GPCRs (AequoScreen cell lines). The acquisition time, plate type, and cell number per well have been optimized to obtain concentration-response curves with 4000 cells/well in 384-well plates and a high signal:background ratio. The FDSS6000 and AequoScreen cell lines allow reading of twenty 96- or 384-well plates in 1 h with Z' values of 0.71 and 0.78, respectively. These results bring new insights to functional assays, and therefore reinforce the interest in aequorin-based assays in a HTS environment.  相似文献   

18.
Sphingosine kinases (SphKs), of which there are two isoforms, SphK1 and SphK2, have been implicated in regulation of many important cellular processes. We have developed an assay for monitoring SphK1 and SphK2 activity in real time without the need for organic partitioning of products, radioactive materials, or specialized equipment. The assay conveniently follows SphK-dependent changes in 7-nitro-2-1,3-benzoxadiazol-4-yl (NBD)-labeled sphingosine (Sph) fluorescence and can be easily performed in 384-well plate format with small reaction volumes. We present data showing dose-proportional responses to enzyme, substrate, and inhibitor concentrations. The SphK1 and SphK2 binding affinities for NBD-Sph and the IC50 values of inhibitors determined were consistent with those reported with other methods. Because of the versatility and simplicity of the assay, it should facilitate the routine characterization of inhibitors and SphK mutants and can be readily used for compound library screening in high-throughput format.  相似文献   

19.
A scintillation proximity assay for rna detection   总被引:2,自引:0,他引:2  
  相似文献   

20.
A homogenous high-throughput assay has been developed to measure the binding between nuclear receptors and test compounds. This assay applies a fluorescence polarization (FP) detection method using human glucocorticoid receptor (GR) as a model system. Crude receptor extract, which requires no additional purification, is used in the assay. The binding conditions (i.e., DMSO tolerance, temperature, stability, and variability) have been investigated and validated. At the optimized conditions, a signal-to-background ratio of 2:1 and a Z'-factor of 0.7 was achieved in a 384-well format. Several known strong and weak GR ligands have been evaluated in this system. Possible interference of fluorescent compounds and methods to identify false positives are also discussed. This FP-based assay system can potentially be used for many soluble nuclear receptors in high-throughput binding assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号