首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract. The use of three techniques for determining yield turgor in excised Salix leaves was investigated. These were the osmotic-solutions technique, the psychrometer technique, and the pressure-chamber technique. The application of the osmotic-solutions technique to a range of leaf types was discussed and the appropriate corrections for volume changes and the contribution of apoplastic water were detailed. It was concluded that the osmotic-solutions technique is not satisfactory for use with slowly growing and/or very elastic leaves. The psychrometer and pressure-chamber techniques were both simple compared with the osmotic-solutions technique, and gave values for yield turgor in the range of 0·3–0·5 MPa. A disadvantage of the psychrometer technique for field applications is that it requires one psychrometer chamber per sample. The pressure-chamber technique was modified for use as a field technique where multiple sampling could be easily and inexpensively achieved. Particular care was required with this technique to prevent water loss from the leaf during stress relaxation, but simple and effective procedures for doing so were found. The modified pressure-chamber technique described here, is recommended as the preferred technique for measuring the yield turgor of leaves in experiments where many simultaneous estimates of yield turgor are to be made.  相似文献   

2.
A new technique is described for the radioassay of gas-producing reactions. The technique is simple and rapid and is useful for the determination of enzyme activities on a routine basis. The technique involves a closed reaction system and gas-solid scintillation counting with scintillator plastic.  相似文献   

3.
黄勇 《微生物学通报》2007,34(1):0169-0172
细菌病仍然是目前危害人类和动物的重要疾病。细菌突变技术是重要的细菌学研究技术,包括传统的物理、化学、生物学等方法及现代的基因突变技术。基因突变技术是目前细菌学研究的重点,不同的基因突变技术采用的策略不同。细菌基因突变技术的开发和应用为细菌疫苗研制、细菌基因功能研究和基因治疗提供了新的技术手段。  相似文献   

4.
A technique is described for obtaining most probable number estimates of the number of cells of a bacterial strain(s) when it is present in low numbers in the soil. The technique is based on the bacteriophage response that is elicited when a known number of bacteriophage for the bacterium of interest is incubated with soil dilutions in a nutrient broth. The technique was evaluated for use with gram-negative bacteria.  相似文献   

5.
Flapless technique is a surgical approach of implant placement without raising a mucoperiosteal flap. Such approach has many advantages: shorter surgical treatment, minimal bleeding, postoperative discomfort for the patient is reduced; possibility of immediate loading of the inserted implant, faster procedure of implant placement and by that less time is needed for the complete implant-prosthetic restoration. Purpose of this pilot study was radiographic assessment of flapless technique and determination of its clinical values in comparison with two-stage dental implant technique through computerized densitometric analysis. The sample consisted of 10 patients with missing teeth in the premolar region in the upper jaw. An implant was placed in that position. In the first group of 5 patients the implants were inserted with the flapless technique, and in the other group of 5 patients implant insertion was done with a two-stage technique. All inserted implants were loaded with metal-ceramic crowns 3 months after placement. The patients were followed for 18 months through clinical follow-ups and radiovisiographical (RVG) images made after 3, 12 and 18 months. After comparing the average densities, the results showed similar decrease of density in both groups, conventional two-stage technique showed 3.24 and flapless technique 1.23. It can be concluded that flapless technique in everyday clinical usage has the same result as the two-stage dental implant technique.  相似文献   

6.
The solid-phase technique for the detection of antibodies and antigens has been developed and named the bacteriosorption test. The test is based on binding staphylococci containing protein A with the Fc-regions of IgG-antibodies attached to antigens immobilized on polystyrene. The possibilities of this technique have been analyzed with the use of diphtheria toxoid, house-dust allergen and homologous rabbit antisera. In the detection of antibodies the proposed test is not inferior to the passive hemagglutination test, and its sensitivity in the detection of antigens by the sandwich technique reaches 0.05-0.1 micrograms/ml. The specificity of the technique has been experimentally confirmed by the inhibition of the reaction with soluble antigen and staphylococcal protein A. The variability factor of the technique does not exceed 10%.  相似文献   

7.
Purpose:To demonstrate a capsulorhexis technique using predominantly shearing forces with a cystotome on a virtual reality simulator and on a human eye.Method:Our technique involves creating the initial anterior capsular tear with a cystotome to raise a flap. The flap left unfolded on the lens surface. The cystotome tip is tilted horizontally and is engaged on the flap near the leading edge of the tear. The cystotome is moved in a circular fashion to direct the vector forces. The loose flap is constantly swept towards the centre so that it does not obscure the view on the tearing edge.Results:Our technique has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. The capsulorhexis flap is moved away from the tear leading edge allowing better visualisation of the direction of tear. This technique offers superior control of the capsulorhexis by allowing the surgeon to change the direction of the tear to achieve the desired capsulorhexis size.Conclusions:The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis techniques. The shearing forces technique is a suitable alternative and in some cases a far better technique in achieving the desired capsulorhexis.  相似文献   

8.
We have developed a microagglutination test for typing rhesus monkey erythrocytes that is sensitive, accurate and easy to perform. The technique requires only microliter quantities of antiserum and cells, and agglutination is easily detected using an inverted microscope. An advantage of this technique is that the typing plates can be stored at -70 degrees C without loss of activity. The results of typing over 400 rhesus blood samples with this technique were 95% concordant with results using the standard microtitre agglutination technique. Preliminary results indicate that this test is also adaptable to typing human blood.  相似文献   

9.
Summary. We have developed a microagglutination test for typing rhesus monkey erythrocytes that is sensitive, accurate and easy to perform. The technique requires only μ1 quantities of antiserum and cells, and agglutination is easily detected using an inverted microscope. An advantage of this technique is that the typing plates can be stored at -70°C without loss of activity. The results of typing over 400 rhesus blood samples with this technique were 95% concordant with results using the standard microtitre agglutination technique. Preliminary results indicate that this test is also adaptable to typing human blood.  相似文献   

10.
噬菌体展示技术是(Phage Display Techniques,PDT)一种将外源肽或蛋白基因与噬菌体特定蛋白基因在其表面进行融合表达的新技术。该技术已在生命科学的各个领域得到广泛应用,近几年,在展示系统及筛选方法这两个关键环节上有了长足进展,就这两方面做一综述。  相似文献   

11.
A technique for the differential staining of sister chromatids with basic fuchsin is described. The resulting staining pattern is the reverse of that obtained with a similar technique using Giemsa dye.  相似文献   

12.
The substantial expansion of investigations into the higher nervous activity of man quite understandably results in constantly increasing interest in matters of technique in such investigations. Along with unceasing searches for new approaches to research technique, there is re-examination and improvement of the old ones, in accordance with the latest progress in science. There is nothing surprising in the fact that considerable attention is given, in the literature of the past few years, to one of the most widely-employed methods of investigation of human higher nervous activity - the motor technique with verbal reinforcement. The lively exchange of opinions with respect to certain problems involved in the application of this technique will doubtless be fruitful in the further development of physiology, psychology, and medicine.  相似文献   

13.
The spot-plate method for determining in vitro antibiotic susceptibility is a modified version of the standard tube dilution technique, with the same principle of twofold dilution. Results of the spot-plate method are compared with those of the standard tube dilution technique. It is proposed that the spot-plate method is an equally accurate, but more rapid and economical, technique for determining in vitro antibiotic susceptibility.  相似文献   

14.
R F Vining 《Steroids》1980,36(2):149-159
A technique for the rapid extraction of steroids from serum prior to their radioimmunoassay is described. The technique is based on the use of mini-columns filled with kieselguhr (Extrelut; Merck). The columns provide a means of achieving a rapid and precise extraction without the problem of emulsion formation and without the necessity to accurately measure organic solvent volumes. The technique is inexpensive, time saving and at least as precise as most conventionally extracted steroid assays. The results achieved correlate well with those of a conventionally extracted assay.  相似文献   

15.
A new cell kinetic approach is presented from which the duration of the S and G2 + M phases can be estimated. The technique involves an analysis of the spatial distribution of labelled cells in sections or sheets of epithelium (i.e. an analysis of clustered labelled cells). The technique is largely independent of the absolute number of labelled cells and hence is not influenced by factors which affect the absolute number of labelled cells. The technique is described and experimental data from dorsal murine skin are presented. The technique has also been simulated mathematically so that the phase durations and their variances could be estimated. The advantages of the technique are: it is technically simple; it provides at least two independent estimates of the phase durations; unlabelled cells need not be counted (compare with LI or PLM analysis); it is independent of variations in the absolute yield of labelled cells, and it is applicable if the LI is low and the S phase is short (where the PLM technique tends to fail).  相似文献   

16.
The results of the analysis of 1209 serum samples, made with a view to detecting those containing HBsAg, are presented. This analysis was made by the radioimmunoassay (RIA) on a polyethylene film, by the standard RIA technique with the use of a diagnostic kit obtained from Abbott Laboratories (USA) and by the passive hemagglutination (PHA) test. The RIA film technique was found to have the sensitivity of about 2 ng/ml HBsAg, which is similar to the sensitivity of the kit from Abbott Laboratories and exceeds the sensitivity of the PHA test approximately 50-fold. The percentage of detected HBsAg-positive sera, yielded by analysis with the use of the RIA film technique and the standard RIA technique, is the same. The RIA technique make it possible to detect more positive sera than the PHA test by about 2.5%.  相似文献   

17.
Foda HM 《Plastic and reconstructive surgery》2003,112(5):1408-17; discussion 1418-21
The droopy tip is a common nasal deformity in which the tip is inferiorly rotated. Five hundred consecutive rhinoplasty cases were studied to assess the incidence and causes of the droopy tip deformity and to evaluate the role of three alar cartilage-modifying techniques--lateral crural steal, lateral crural overlay, and tongue in groove--in correcting such a deformity. The external rhinoplasty approach was used in all cases. Only one of the three alar cartilage-modifying techniques was used in each case, and the degree of tip rotation and projection was measured both preoperatively and postoperatively. The incidence of droopy tip was 72 percent, and the use of an alar cartilage-modifying technique was required in 85 percent of these cases to achieve the desired degree of rotation. The main causes of droopy tip included inferiorly oriented alar cartilages (85 percent), overdeveloped scrolls of upper lateral cartilages (73 percent), high anterior septal angle (65 percent), and thick skin of the nasal lobule (56 percent). The lateral crural steal technique increased nasal tip rotation and projection, the lateral crural overlay technique increased tip rotation and decreased tip projection, and the tongue-in-groove technique increased tip rotation without significantly changing the amount of projection. The lateral crural overlay technique resulted in the highest degrees of rotation, followed by the lateral crural steal and finally the tongue-in-groove technique. According to these results, the lateral crural steal technique is best indicated in cases with droopy underprojected nasal tip, the lateral crural overlay technique in cases of droopy overprojected nasal tip, and the tongue-in-groove technique in cases where the droopy nasal tip is associated with an adequate amount of projection.  相似文献   

18.
The technique of repairing defects of the skull with titanium is described. The skull contour can be accurately reproduced. The technique is simpler than wiring or suturing methods. The material is inert, radiolucent, and rigid.  相似文献   

19.
We have investigated the use of an avidin-biotin-immunoglucose oxidase (AB-GO) technique for single and double antigen localization in conjunction with the avidin-biotin-immunoperoxidase (AB-P) technique in fixed, embedded specimens, using sequential monoclonal and polyclonal antibodies of the same species. The optimal technique for double labeling requires the first antibody to be applied and localized with the AB-P technique using 3,3'-diaminobenzidine (DAB) as the chromogen, followed by an optional elution step and/or incubation with mild detergent (0.01% Triton). The second antigen is localized with the AB-GO technique with nitro blue tetrazolium (NBT) as a chromogen. Effects of antigen concentration, intermediate elution steps, and the relative efficiency of the two methodologies are described.  相似文献   

20.
A new optical measurement technique based on spectral scanning is described for the determination of oxygen saturation of whole blood. The principles of this technique are outlined, together with a calibration procedure used to test its feasibility in vitro. The preliminary results show that the accuracy of the new technique is of the order ± 2% over the full range of oxygen saturation. This degree of accuracy is comparable with commercial CO-oximeters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号