首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Although genome databases have become the key for proteomic analyses, de novo sequencing remains essential for the study of organisms whose genomes have not been completed. In addition, post-translational modifications present a challenge in database searching. Recognition of the b or y-ion series in a peptide MS/MS spectrum as well as identification of the b1 - and yn-1 -ions can facilitate de novo analyses. Therefore, it is valuable to identify either amino-acid terminus. In previous work, we have demonstrated that peptides modified at the epsilon-amino group of lysine as a t-butyl peroxycarbamate derivative undergo free radical promoted peptide backbone fragmentation under low-energy collision-induced dissociation (CID) conditions. Here we explore the chemistry of the N-terminal amino group modified as a t-butyl peroxycarbamate. The conversion of N-terminal amines to peroxycarbamates of simple amino acids and peptides was studied with aryl t-butyl peroxycarbonates. ESI-MS/MS analysis of the peroxycarbamate adducts gave evidence of a product ion corresponding to the neutral loss of the N-terminal side chain (R), thus identifying this residue. Further fragmentation (MS3) of product ions formed by N-terminal residue side-chain loss (-R) exhibited an m/z shift of the b-ions equal to the neutral loss of R, therefore labeling the b-ion series. The study was extended to the analysis of a protein tryptic digest where the SALSA algorithm was used to identify spectra containing these neutral losses. The method for N-terminus identification presented here has the potential for improvement of de novo analyses as well as in constraining peptide mass mapping database searches.  相似文献   

2.
Over the past decade peptide sequencing by collision induced dissociation (CID) has become the method of choice in mass spectrometry-based proteomics. The development of alternative fragmentation techniques such as electron transfer dissociation (ETD) has extended the possibilities within tandem mass spectrometry. Recent advances in instrumentation allow peptide fragment ions to be detected with high speed and sensitivity (e.g., in a 2D or 3D ion trap) or at high resolution and high mass accuracy (e.g., an Orbitrap or a ToF). Here, we describe a comprehensive experimental comparison of using ETD, ion-trap CID, and beam type CID (HCD) in combination with either linear ion trap or Orbitrap readout for the large-scale analysis of tryptic peptides. We investigate which combination of fragmentation technique and mass analyzer provides the best performance for the analysis of distinct peptide populations such as N-acetylated, phosphorylated, and tryptic peptides with up to two missed cleavages. We found that HCD provides more peptide identifications than CID and ETD for doubly charged peptides. In terms of Mascot score, ETD FT outperforms the other techniques for peptides with charge states higher than 2. Our data shows that there is a trade-off between spectral quality and speed when using the Orbitrap for fragment ion detection. We conclude that a decision-tree regulated combination of higher-energy collisional dissociation (HCD) and ETD can improve the average Mascot score.  相似文献   

3.
Zhu Z  Becklin RR  Desiderio DM  Dalton JT 《Biochemistry》2001,40(36):10756-10763
The ligand-binding domain (LBD) of the human androgen receptor (hAR LBD), encompassing amino acids (AAs) 647-919, was expressed in Escherichia coli with an N-terminal polyhistidine tag (His(10)-hAR LBD) from a pET-16b vector. The overexpressed protein was initially insoluble in inclusion bodies, and was subsequently solubilized in 8 M guanidine hydrochloride (GdnHCl). The solubilized His(10)-hAR LBD was purified to apparent homogeneity by metal ion affinity chromatography in the presence of 6 M GdnHCl. The isolated protein migrated as a single band in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with an apparent molecular mass of 33-34 kDa, as expected from the plasmid construct. Immunoblot analysis with C-terminal antibodies raised against a peptide corresponding to the last 19 AAs (AAs 901-919) of hAR revealed that the purified protein contained an immunoreactive epitope present within the AR and was of the appropriate size. Further characterization, using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS), showed a single protein species of average mass 34 580 Da, confirming the size and purity of the purified His(10)-hAR LBD. Detailed tryptic peptide mapping analysis, using MALDI/TOF-MS, identified a total of eight peptides with a 30% coverage of the LBD, including the last tryptic peptide in the hAR sequence. These data confirm that the purified protein was the intact hAR LBD. AA sequencing of these tryptic peptides, using an HPLC-coupled electrospray ionization ion trap mass spectrometer (LC/ESI-ITMS and MS/MS), unambiguously confirmed that the peptides were from the hAR LBD. The purified His(10)-hAR LBD in 6 M GdnHCl could be renatured as determined by ligand-binding activity, with a similar equilibrium dissociation constant (K(d)) for [(3)H]-mibolerone and a similar steroid specificity to the AR isolated from rat ventral prostate.  相似文献   

4.
An N-terminal hexahistidine-tagged full-length human androgen receptor protein (His(6)-hAR) was overexpressed and purified to apparent homogeneity in the presence of dihydrotestosterone (DHT) in our previous studies. In-gel trypsin digestion of the purified DHT-bound His(6)-hAR, and tryptic peptide mapping using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS), detected a total of 17 peptides (21% coverage of hAR) with 9 peptides originating from the ligand-binding domain (LBD, 31% coverage of LBD). Amino acid sequencing analysis of the tryptic peptides from a separate in-gel digestion of the His(6)-hAR, using HPLC-coupled electrospray ionization ion trap mass spectrometry (LC/ESI-ITMS and MS/MS), unambiguously confirmed 21 peptides with 19% coverage of the hAR, of which 11 peptides originated from the LBD (35% coverage of LBD). These 21 peptides included 11 out of the 17 peptides detected by MALDI/TOF-MS. In addition, a novel serine phosphorylation site (Ser(308)) within the N-terminal transactivation domain of hAR was identified.  相似文献   

5.
An ion trap is a powerful analyzer because of its high resolution, high sensitivity, and multistage mass analysis (MSn) capabilities. Multiple fragmentation analysis provides useful information regarding peptide sequence and biomolecular structure; however, this approach is limited by an inherent low mass cutoff (LMCO) derived from collision-induced dissociation (CID). To avoid the LMCO for application of an ion trap to iTRAQ, we optimized the qz value, which is a parameter that is proportional to the applied fundamental AC radio frequency voltage of a tandem mass spectrometry (MS/MS) event. Considering that many ion trap MS analyses employ CID as the MS/MS method, this method can be a practical one without any instrumental changes.  相似文献   

6.
In proteomics multi-dimensional fractionation techniques are widely used to reduce the complexity of peptide mixtures subjected to mass spectrometric analysis. Here, we describe the sequential use of strong cation exchange and reversed phase liquid chromatography in the separation of peptides generated by a relatively little explored metallo-endopeptidase with Lys-N cleavage specificity. When such proteolytic peptides are subjected to low-pH strong cation exchange we obtain fractionation profiles in which peptides from different functional categories are well separated. The four categories we distinguish and are able to separate to near completion are (I) acetylated N-terminal peptides; (II) singly phosphorylated peptides containing a single basic (Lys) residue; (III) peptides containing a single basic (Lys) residue; and (IV) peptides containing more than one basic residue. Analyzing these peptides by LC-MS/MS using an ion trap with both collision as well as electron transfer-induced dissociation provides unique optimal targeted strategies for proteome analysis. The acetylated peptides in category I can be identified confidently by both CID and ETcaD, whereby the ETcaD spectra are dominated by sequence informative Z-ion series. For the phosphorylated peptides in category II and the "normal" single Lys containing peptides in category III ETcaD provides unique straightforward sequence ladders of c'-ions, from which the exact location of possible phosphorylation sites can be easily determined. The later fractions, category IV, require analysis by both ETcaD and CID, where it is shown that electron transfer dissociation performs relatively well for these multiple basic residues containing peptides, as is expected. We argue that the well resolved separation of functional categories of peptides observed is characteristic for Lys-N-generated peptides. Overall, the combination of Lys-N proteolysis, low-pH strong cation exchange, and reversed phase separation, with CID and ETD induced fragmentation, adds a new very powerful method to the toolbox of proteomic analyses.  相似文献   

7.
We report on the effectiveness of CID, HCD, and ETD for LC-FT MS/MS analysis of peptides using a tandem linear ion trap-Orbitrap mass spectrometer. A range of software tools and analysis parameters were employed to explore the use of CID, HCD, and ETD to identify peptides (isolated from human blood plasma) without the use of specific "enzyme rules". In the evaluation of an FDR-controlled SEQUEST scoring method, the use of accurate masses for fragments increased the number of identified peptides (by ~50%) compared to the use of conventional low accuracy fragment mass information, and CID provided the largest contribution to the identified peptide data sets compared to HCD and ETD. The FDR-controlled Mascot scoring method provided significantly fewer peptide identifications than SEQUEST (by 1.3-2.3 fold) and CID, HCD, and ETD provided similar contributions to identified peptides. Evaluation of de novo sequencing and the UStags method for more intense fragment ions revealed that HCD afforded more contiguous residues (e.g., ≥ 7 amino acids) than either CID or ETD. Both the FDR-controlled SEQUEST and Mascot scoring methods provided peptide data sets that were affected by the decoy database used and mass tolerances applied (e.g., identical peptides between data sets could be limited to ~70%), while the UStags method provided the most consistent peptide data sets (>90% overlap). The m/z ranges in which CID, HCD, and ETD contributed the largest number of peptide identifications were substantially overlapping. This work suggests that the three peptide ion fragmentation methods are complementary and that maximizing the number of peptide identifications benefits significantly from a careful match with the informatics tools and methods applied. These results also suggest that the decoy strategy may inaccurately estimate identification FDRs.  相似文献   

8.
We investigated the interaction between a thiol protease inhibitor, cystatin, and its target enzyme, papain, by hydrogen-deuterium (H/D) exchange in conjunction with successive analysis by collision-induced dissociation (CID) in an rf-only hexapole ion guide with electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS). The deuterium incorporation into backbone amide hydrogens of cystatin was analyzed at different time points in the presence or absence of papain, examining the mass of each fragment produced by hexapole-CID. In the absence of papain, amide hydrogens in short amino-terminal fragments, such as b10(2+) and b12(2+), were highly deuterated within 1 min. Although fewer fragments were observed for the cystatin-papain complex in the hexapole-CID spectra, significant reductions in initial deuterium content were recognized throughout the sequence of cystatin. This suggests that complex formation restricted the flexibility of the whole cystatin molecule. Detailed analyses revealed that a marked reduction in deuterium content in the region of residues 1-10 persisted for hours, suggesting that the flexible N-terminal region was tightly fixed in the binding pocket with hydrogen bonds. Our results are consistent with those of previous studies on the structure and inhibition mechanism of cystatin. We demonstrated here that enzyme-inhibitor interactions can be characterized by H/D exchange in combination with CID in a hexapole ion guide using ESI-FTICR MS rapidly and using only a small amount of sample.  相似文献   

9.
At least four mRNAs for oat phytochrome A (phyA) are present in etiolated oat tissue. The complete amino acid sequences of two phyA isoforms (A3 and A4) and the N-terminal amino acid sequence of a third isoform (A5) were deduced from cDNA sequencing (Hershey et al., 1985). In the present study, heterogeneity of phyA on a protein level was studied by tryptic mapping using electrospray ionization mass-spectrometry (ESIMS). The total tryptic digest of iodoacetamide-modified phyA was fractionated by gel filtration chromatography followed by reversed-phase high-performance liquid chromatography. ESIMS was used to identify peptides. Amino acid sequences of the peptides were confirmed or determined by collision-induced dissociation mass spectrometry (CID MS), MS/MS, or by subdigestion of the tryptic peptides followed by ESIMS analysis. More than 97% of the phyA3 sequence (1,128 amino acid residues) was determined in the present study. Mass-spectrometric analysis of peptides unique to each form showed that phyA purified from etiolated oat seedling is represented by three isoforms A5, A3, and A4, with ratio 3.4:2.3:1.0. Possible light-induced changes in phytochrome in vivo phosphorylation site at Ser7 (Lapko VN et al., 1997, Biochemistry 36:10595-10599) as well at Ser17 and Ser598 (known as in vitro phosphorylation sites) were also analyzed. The extent of phosphorylation at Ser7 appears to be the same for phyA isolated from dark-grown and red-light illuminated seedlings. In addition to Ser7, Ser598 was identified as an in vivo phosphorylation site in oat phyA. Ser598 phosphorylation was found only in phyA from the red light-treated seedlings, suggesting that the protein phosphorylation plays a functional role in the phytochrome A-mediated light-signal transduction.  相似文献   

10.
Trypsin cleaves exclusively C-terminal to arginine and lysine residues   总被引:2,自引:0,他引:2  
Almost all large-scale projects in mass spectrometry-based proteomics use trypsin to convert protein mixtures into more readily analyzable peptide populations. When searching peptide fragmentation spectra against sequence databases, potentially matching peptide sequences can be required to conform to tryptic specificity, namely, cleavage exclusively C-terminal to arginine or lysine. In many published reports, however, significant numbers of proteins are identified by non-tryptic peptides. Here we use the sub-parts per million mass accuracy of a new ion trap Fourier transform mass spectrometer to achieve more than a 100-fold increased confidence in peptide identification compared with typical ion trap experiments and show that trypsin cleaves solely C-terminal to arginine and lysine. We find that non-tryptic peptides occur only as the C-terminal peptides of proteins and as breakup products of fully tryptic peptides N-terminal to an internal proline. Simulating lower mass accuracy led to a large number of proteins erroneously identified with non-tryptic peptide hits. Our results indicate that such peptide hits in previous studies should be re-examined and that peptide identification should be based on strict trypsin specificity.  相似文献   

11.
Egnaczyk GF  Greis KD  Stimson ER  Maggio JE 《Biochemistry》2001,40(39):11706-11714
The assembly of the beta-amyloid peptide (Abeta) into amyloid fibrils is essential to the pathogenesis of Alzheimer's disease. Detailed structural information about fibrillogenesis has remained elusive due to the highly insoluble, noncrystalline nature of the assembled peptide. X-ray fiber diffraction, infrared spectroscopy, and solid-state NMR studies performed on fibrils composed of Abeta peptides have led to conflicting models of the intermolecular alignment of beta-strands. We demonstrate here the use of photoaffinity cross-linking to determine high-resolution structural constraints on Abeta monomers within amyloid fibrils. A photoreactive Abeta(1-40) ligand was synthesized by substituting L-p-benzoylphenylalanine (Bpa) for phenylalanine at position 4 (Abeta(1-40) F4Bpa). This peptide was incorporated into synthetic amyloid fibrils and irradiated with near-UV light. SDS-PAGE of dissolved fibrils revealed the light-dependent formation of a covalent Abeta dimer. Enzymatic cleavage followed by mass spectrometric analysis demonstrated the presence of a dimer-specific ion at MH(+) = 1825.9, the predicted mass of a fragment composed of the N-terminal Abeta(1-5) F4Bpa tryptic peptide covalently attached to the C-terminal Abeta(29-40) tryptic peptide. MS/MS experiments and further chemical modifications of the cross-linked dimer led to the localization of the photo-cross-link between the ketone of the Bpa4 side chain and the delta-methyl group of the Met35 side chain. The Bpa4-Met35 intermolecular cross-link is consistent with an antiparallel alignment of Abeta peptides within amyloid fibrils.  相似文献   

12.
Lee YH  Kim MS  Choie WS  Min HK  Lee SW 《Proteomics》2004,4(6):1684-1694
Recently, various chemical modifications of peptides have been incorporated into mass spectrometric analyses of proteome samples, predominantly in conjunction with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS), to facilitate de novo sequencing of peptides. In this work, we investigate systematically the utility of N-terminal sulfonation of tryptic peptides by 4-sulfophenyl isothiocyanate (SPITC) for proteome analysis by capillary reverse-phase liquid chromatography/tandem mass spectrometry (cRPLC/MS/MS). The experimental conditions for the sulfonation were carefully adjusted so that SPITC reacts selectively with the N-terminal amino groups, even in the presence of the epsilon-amino groups of lysine residues. Mass spectrometric analyses of the modified peptides by cRPLC/MS/MS indicated that SPITC derivatization proceeded toward near completion under the experimental conditions employed here. The SPITC-derivatized peptides underwent facile fragmentation, predominantly resulting in y-series ions in the MS/MS spectra. Combining SPITC derivatization and cRPLC/MS/MS analyses facilitated the acquisition of sequence information for lysine-terminated tryptic peptides as well as arginine-terminated peptides without the need for additional peptide pretreatment, such as guanidination of lysine amino group. This process alleviated the biased detection of arginine-terminated peptides that is often observed in MALDI MS experiments. We will discuss the utility of the technique as a viable method for proteome analyses and present examples of its application in analyzing samples having different levels of complexity.  相似文献   

13.
Protein phosphorylation modulates a myriad of biological functions, and its regulation is vital for proper cellular activity. Mass spectrometry is the enabling tool for phosphopeptide analysis, where recent instrumentation advances in both speed and sensitivity in linear ion trap and orbitrap technologies may yield more comprehensive phosphoproteomic analyses in less time. Protein phosphorylation analysis by MS relies on structural information derived through controlled peptide fragmentation. Compared with traditional, ion-trap-based collision-induced dissociation (CID), a more recent type of fragmentation termed HCD (higher energy collisional dissociation) provides beam type CID tandem MS with detection of fragment ions at high resolution in the orbitrap mass analyzer. Here we compared HCD to traditional CID for large-scale phosphorylation analyses of murine brain under three separate experimental conditions. These included a same-precursor analysis where CID and HCD scans were performed back-to-back, separate analyses of a phosphotyrosine peptide immunoprecipitation experiment, and separate whole phosphoproteome analyses. HCD generally provided higher search engine scores with more peptides identified, thus out-performing CID for back-to-back experiments for most metrics tested. However, for phosphotyrosine IPs and in a full phosphoproteome study of mouse brain, the greater acquisition speed of CID-only analyses provided larger data sets. We reconciled our results with those in direct contradiction from Nagaraj N, D'Souza RCJ et al. (J. Proteome Res. 9:6786, 2010). We conclude, for large-scale phosphoproteomics, CID fragmentation with rapid detection in the ion trap still produced substantially richer data sets, but the back-to-back experiments demonstrated the promise of HCD and orbitrap detection for the future.  相似文献   

14.
The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.  相似文献   

15.
The phosphorylation sites of two phosphorylated proteins, bovine β-casein and myelin basic protein (MBP), were identified by high performance liquid chromatography-electrospray ionization-quadrupole ion trap mass spectrometry (HPLC-ESI-QITMS). The tryptic digest of each protein was separated by HPLC, the molecular weight of each peptide was determined by ESI-QITMS on line, and MS/MS spectrum of each peptide was simultaneously obtained by the combination of collision-induced desorption (CID) technique and tandem mass spectrometry (MS/MS) of QITMS. The phosphorylated peptide was identified by looking into whether the difference between the observed and predicted molecular weights of a peptide is 80 u or its integral multiple. Then the phosphorylation site was identified through manual interpretation of the MS/MS spectrum of the phosphorylated peptide or automatic SEQUEST data base-searching.  相似文献   

16.
毛细管区带电泳/串联质谱联用法鉴定多肽和蛋白质   总被引:11,自引:3,他引:8  
建立了毛细管区带电泳-串联质谱联用(CZE/MS/MS)对多肽和蛋白质高灵敏度鉴定方法,对Met-脑啡肽和Leu-脑啡肽的混合物进行了分析,用CZE/MS/MS方法验证了各自的序列,同样对细胞色素c的胰蛋白酶酶解产物用CZE/MS/MS方法进行了肽质谱分析,几科所有肽段的序列及其与在分子中的位置都得到了确定,通过SEQUEST软件进行蛋白质序列数据库搜索得到准确的鉴定结果,所消耗的样品量均在低皮可  相似文献   

17.
We have previously shown that streptozotocin (STZ) inhibits O-GlcNAc-selective N-acetyl-beta-d-glucosaminidase (O-GlcNAcase), the enzyme that removes O-GlcNAc from proteins. In light of this observation, we explored the possibility that the diabetogenic toxin alloxan, an O-GlcNAc transferase (OGT) inhibitor, might also inhibit O-GlcNAcase. Alloxan inhibited islet O-GlcNAcase with a dose-response much like that of STZ. Similar to STZ, islet O-GlcNAcase was more susceptible to alloxan inhibition than was brain O-GlcNAcase. Alloxan directly inhibited recombinant O-GlcNAcase activity with a dose-response very similar to that of STZ. Subsequent LC/MS/MS analysis revealed that alloxan modified the tryptic digest pattern of the enzyme. One tryptic peptide LGCFEIAK(894-901) was modified by alloxan. Two other tryptic peptides, LDQVSQFGCR(158-167) and SFALLFDDIDHNMCAADK(168-185), both N-terminal active site peptides, were absent after alloxan treatment. Together, these data demonstrate that alloxan is an inhibitor of O-GlcNAc-selective N-acetyl-beta-d-glucosaminidase, with inhibition corresponding to an altered tryptic digest pattern of N-terminal active site peptides.  相似文献   

18.
The use and applicability of silica based capillary monolithic reversed-phase columns in proteomic analysis has been evaluated by liquid chromatography-mass spectrometry (LC-MS). Chromatographic performance of the monolithic capillaries was evaluated with a tryptic digest of cytochrome C showing very good resolution and reproducibility in addition to the known advantages of a low pressure drop over a time period of 6 months. Monoliths were subsequently tested for their suitability to separate proteins and peptides from samples typically encountered in proteomic research such as in-gel digested tryptic peptide mixtures or fractions of proteolytically digested human serum. The monolithic capillaries also proved useful in the analysis of phospholipid species in bronchoalveolar lavage fluid. Compared to particle-filled conventional capillary columns, rapid and highly efficient separation of peptides and proteins was achieved using these bimodal pore size distribution columns, and good quality collision induced dissociation (CID) mass spectra were obtained on an ion trap mass spectrometer. These novel monolithic separation media are thus a promising addition to the methodological toolbox of proteomics research.  相似文献   

19.
We have developed a new and sensitive LC-MS platform, Extended Range Proteomic Analysis (ERPA), which is able to achieve very high sequence coverage and comprehensive characterization of post-translational modifications in complex proteins. This new platform provides advantages of both the top-down and bottom-up proteomic approaches by combining (i) digestion of the protein with an enzyme, such as Lys-C, which cuts less frequently than trypsin, leading to on average a higher molecular weight peptide size, (ii) high-performance LC separation of the resulting fragments, (iii) a new data acquisition strategy using the LTQ-FTMS, a hybrid mass spectrometer that couples a linear ion trap with a Fourier transform ion cyclotron resonance (FTICR) cell, for analysis of peptides in the range of 0.5 to 10 kDa, and (iv) new data analysis methods for assigning large peptide structures and determining the site of attachment of post-translational modifications as well as structural features from the accurate precursor mass together with MS(2) and MS(3) fragmentations. The LC retention of the Lys-C fragments is increased, relative to a tryptic digest, due to the generally greater hydrophobicity of the larger peptides, a result that is particularly important for peptides containing hydrophilic modifications such as glycosylation and phosphorylation. Furthermore, additional positively charged arginine and lysine residues in the Lys-C fragments enhance the sensitivity of the post-translationally modified phospho- and glycopeptides by at least 10-fold relative to tryptic fragments. In typical operation, the FTICR cell provides a survey scan with the high mass resolution (> 100 000) and accurate mass (<2 ppm) to characterize the higher charge-state precursor ions of the larger peptides. In parallel, the linear ion trap provides MS(2) and MS(3) fragmentation spectra, with a scan speed sufficiently fast for on-line LC-MS. Together, these data provide multiple means to determine or enhance the confidence of assignment of large or complicated peptide. Using ERPA, we demonstrate >95% sequence coverage in the analysis of two heavily phosphorylated and glycosylated proteins, beta-casein at the 50 fmole level and the epidermal growth factor receptor (EGFR) at the 1 pmole level. In summary, the combination of digestion strategy, high-performance separation, and the hybrid LTQ-FTMS instrument enables comprehensive characterization of large proteins, including posttranslational modifications.  相似文献   

20.
We describe an enabling technique for proteome analysis based on isotope-differential dimethyl labeling of N-termini of tryptic peptides followed by microbore liquid chromatography (LC) matrix-assisted laser desorption and ionization (MALDI) mass spectrometry (MS). In this method, lysine side chains are blocked by guanidination to prevent the incorporation of multiple labels, followed by N-terminal labeling via reductive amination using d(0),(12)C-formaldehyde or d(2),(13)C-formaldehyde. Relative quantification of peptide mixtures is achieved by examining the MALDI mass spectra of the peptide pairs labeled with different isotope tags. A nominal mass difference of 6 Da between the peptide pair allows negligible interference between the two isotopic clusters for quantification of peptides of up to 3000 Da. Since only the N-termini of tryptic peptides are differentially labeled and the a(1) ions are also enhanced in the MALDI MS/MS spectra, interpretation of the fragment ion spectra to obtain sequence information is greatly simplified. It is demonstrated that this technique of N-terminal dimethylation (2ME) after lysine guanidination (GA) or 2MEGA offers several desirable features, including simple experimental procedure, stable products, using inexpensive and commercially available reagents, and negligible isotope effect on reversed-phase separation. LC-MALDI MS combined with this 2MEGA labeling technique was successfully used to identify proteins that included polymorphic variants and low abundance proteins in bovine milk. In addition, by analyzing a mixture of two equal amounts of milk whey fraction as a control, it is shown that the measured average ratio for 56 peptide pairs from 14 different proteins is 1.02, which is very close to the theoretical ratio of 1.00. The calculated percentage error is 2.0% and relative standard deviation is 4.6%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号