首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

The simultaneous, rapid and reliable measurement of a wide steroid panel is a powerful tool to unravel physiological and pathological hormone status. Clinical laboratories are currently dominated by high-throughput immunoassays, but these methods lack specificity due to cross-reactivity and matrix interferences. We developed and validated an isotopic dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method for the simultaneous measurement of cortisol, corticosterone, 11deoxycortisol, androstenedione, deoxycorticosterone (DOC), testosterone, 17OHprogesterone, dehydroepiandrosterone (DHEA) and progesterone in serum, and compared it to routine immunoassays employed in our laboratory. We also established adult reference intervals in 416 healthy subjects.

Methods

0.9 ml of serum were spiked with labelled internal standards (IS) and extracted on C18 cartridges. Eluate was injected into a two-dimensional LC-system, purified in a perfusion column and separated on a C8 column during a 21 min gradient run. Analytes were revealed by atmospheric pressure chemical ionization (APCI) followed by multiple reaction monitoring (MRM) analysis.

Results

Of the four immunoassays compared with the ID-LC-MS/MS method, only the results of ElecsysE170 for cortisol, testosterone in males and progesterone > 1 ng/ml were in agreement with ID-LC-MS/MS. ElecsysE170 for testosterone in females and progesterone < 1 ng/ml, Immulite2000 for androstenedione, DSL-9000 for DHEA and 17OHP Bridge for 17OHprogesterone, respectively, showed poor agreement. Reference intervals and steroid age and fertility related fluctuations were established.

Conclusion

Our ID-LC-MS/MS method proved to be reliable and sensitive in revealing steroid circulating concentrations in adults and in highlighting the limits of routine immunoassays at low concentrations.  相似文献   

2.
Steroid 21-hydroxylase activity of the microsome-enriched fraction of follicular linings from equine ovaries has been demonstrated by gas chromatography-mass spectrometry. The 21-hydroxylated metabolites were quantified by isotope dilution with deuterated analogues. The two most abundant potential substrates for follicular steroid 21-hydroxylase, progesterone (P) and 17-hydroxyprogesterone (17OHP), were converted respectively to 11-deoxycorticosterone (DOC) and 11-deoxycortisol with corresponding apparent specific activities of 308 and 24 pmol/mg protein/h and apparent Km values of 1.1 and 6.4 microM. Competitive inhibition of the P-to-DOC conversion was exerted by 17OHP and pregnenolone. Hence, the ovarian follicle of the mare is an extraadrenal site of preferential DOC biosynthesis by an enzyme having steroid 21-hydroxylase activity.  相似文献   

3.
Adrenal steroid profiling, including 17α-OH progesterone (17OHP), 11-deoxycortisol (S), Δ4-androstenedione (Δ4-A) and cortisol (F) in blood spots by tandem mass spectrometry, is used for newborn screening to detect congenital adrenal hyperplasia (CAH). Pre-analytical sample processing is critical for assay specificity and accuracy; however, it is laborious and time-consuming. This study describes the development and validation of a new Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method for the simultaneous quantification of five steroids: 17OHP, S, Δ4-A, F and cortisone (E) in blood spots from newborns. Whole blood was eluted from a 5.00 mm dried blood spot by an aqueous solution containing the deuterium-labeled internal standards d8-17OHP and d4-cortisol. The steroids extracted from blood spot into aqueous solution were subsequently purified via Extelut mini NT1 column using diethylether. The extracts were evaporated and quantified using LC-MS/MS. The detection limit was 0.25 ng/mL for 17OHP and S, 0.4 ng/mL for Δ4-A and 0.5 ng/mL for F and E. The limit of quantification was 0.5 ng/mL for 17OHP, S and Δ4-A and 1 ng/mL for F and E. Precision for 17OHP, S, Δ4-A at concentrations of 0.5, 2, and 8 ng/mL (n=5) in fortified steroid free serum samples was 1.3-3.5% (intra-assay CV) and 7-14.8% (inter-assay CV). Precision for F and E at concentrations of 5 and 20 ng/mL was 1.5-4.8% (intra-assay, CV%) and 6-15% (inter-assay, CV%). Accuracy was calculated at concentrations of 0.5, 2, and 8 ng/mL for 17OHP, S and Δ4-A and ranged from -0.3 to 0.2%, while for F and E it ranged from -3.2 to 0.2%. Relative recoveries at concentration 2 ng/mL and 8 ng/mL for 17OHP, S, Δ4-A and at 5 ng/mL and 20 ng/mL for F and E ranged from 55% to 80%. Reference intervals were estimated for all steroids in newborns (on day 3). The steroid profile assay herein described is sensitive, specific and accurate and involves a simple pre-analytical sample manipulation; it is therefore suitable for routine analysis and provides data for samples within normal range as well as those with elevated levels. For the first time to our knowledge, cortisone levels are reported in dried blood spots from newborns.  相似文献   

4.
An adrenocortical tumor secreting weak mineralocorticoids   总被引:1,自引:0,他引:1  
An adrenocortical carcinoma (15.5 g) secreting excessive amounts of steroids with weak mineralocorticoid activity in a 25-year-old woman was studied with particular reference to its in vivo and in vitro secretions of steroids. Severe hypertension, occasional low serum potassium and suppressed PRA were the major clinical findings, and were improved with removal of the tumor. In the preoperative stage, plasma levels of 11-deoxycorticosterone, 18-hydroxy-11-deoxycorticosterone, corticosterone and 18-hydroxycorticosterone were all increased. However, the plasma level of aldosterone was repeatedly normal. Although plasma levels of pregnenolone, 17-hydroxypregnenolone, progesterone and 17-hydroxyprogesterone were very high, those of other late step steroids, i.e. 11-deoxycortisol, cortisol, dehydroepiandrosterone, androstenedione and testosterone were almost normal. From these findings, a major etiological role of weak mineralocorticoids such as 11-deoxycorticosterone, 18-hydroxycorticosterone and corticosterone in her hypertension was suggested. Pregnenolone and 17-hydroxypregnenolone in tumor tissue were increased, but 11-deoxycorticosterone, corticosterone, aldosterone, cortisol and adrenal androgens such as dehydroepiandrosterone, androstenedione and testosterone were below normal or low normal. In vitro production of 11-deoxycorticosterone, aldosterone or cortisol by the tumor tissue slices was very low and scarcely responded to synthetic ACTH.  相似文献   

5.
Rauh M  Gröschl M  Rascher W  Dörr HG 《Steroids》2006,71(6):450-458
Plasma 17 alpha-hydroxyprogesterone (17-OHP), androstenedione and testosterone measurements are important for the diagnosis and monitoring of hyperandrogenic disorders, most importantly for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency. The reliability of immunoassays has proved questionable especially for newborns and children. In order to reduce the analytical interferences due to cross-reactivity or matrix effects, to improve accuracy and shorten the analysis time, we have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with atmospheric pressure chemical ionization (APCI) for simultaneous measurement. An on-line extraction cartridge with column-switching technique and liquid chromatography over a Chromolith RP 18 e column allow a rapid and easy quantification. The lowest limit of detection was 0.03-0.06 microg/L. Our method has proved linear up to 250 microg/L (r=0.999). Recoveries (S.D.) of 17-OHP, androstenedione and testosterone in plasma were 100% (5), 102% (2) and 92% (4), respectively. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for 17-OHP (excluding neonate samples) was y=1.942 x+0.255 nmol/L (r=0.695; n=97). In comparison to our values, the immunoassay generally overestimates steroid concentration. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for testosterone was y=0.963 x+0.035 nmol/L (r=0.955; n=107). Preliminary reference intervals for children were determined as a function of age and sex. The sensitivity and specificity of the LC-MS/MS method offer advantages over routine immunoassays due to the elimination of interferences especially for newborns, high throughput and short chromatographic run time.  相似文献   

6.
OBJECTIVE: To evaluate adrenal steroid hormone secretion in response to corticotropin-releasing factor (CRF) or to adrenocorticotropin hormone in women with hypothalamic amenorrhea. DESIGN: Controlled clinical study. SETTING: Department of Reproductive Medicine and Child Development, Section of Gynecology and Obstetrics, University of Pisa, Italy. PATIENT(S): Fifteen women with hypothalamic amenorrhea were enrolled in the study. Eight normal cycling women were used as control group. INTERVENTION(S): Blood samples were collected before and after an injection of ovine CRF (0.1 microg/kg iv bolus) or after synthetic ACTH (0.25 mg iv). MAIN OUTCOME MEASURE(S): Plasma levels of ACTH, 17-hydroxypregnenolone (17OHPe), progesterone (P), dehydroepiandrosterone (DHEA), 17-hydroxyprogesterone (17OHP), cortisol (F), 11-deoxycortisol (S) and androstenedione (A). RESULT(S): Basal plasma concentrations of ACTH, cortisol, 11-deoxycortisol, DHEA and 17OHPe were significantly higher in patients than in controls, whereas plasma levels of progesterone and 17-OHP were significantly lower in patients than in controls. In amenorrheic women the ratio of 17-OHPe/DHEA, of 17-OHPe/17-OHP and of 11-deoxycortisol/cortisol were significantly higher than in controls, while a significant reduction in the ratio of 17-OHP/androstenedione, of 17-OHP/11-deoxycortisol was obtained. In response to corticotropin-releasing factor test, plasma levels of ACTH, cortisol, 17-OHP, 11-deoxycortisol, DHEA and androstenedione were significantly lower in patients than in controls. In response to adrenocorticotropin hormone, plasma levels of 17-OHP, androstenedione and androstenedione/cortisol were significantly higher in patients than in controls. CONCLUSIONS: Patients suffering for hypothalamic amenorrhea showed an increased activation of hypothalamus-pituitary-adrenal (HPA) axis, as shown by the higher basal levels and by augmented adrenal hormone response to corticotropin-releasing factor administration. These data suggest a possible derangement of adrenal androgen enzymatic pathway.  相似文献   

7.
The effects of R 76,713 on steroidogenesis were studied in primary cultures of four different human cell types, i.e. ovarian granulosa cells, adipose stromal cells, testicular cells and adrenal cells. In human granulosa cells aromatization of [1 beta, 2 beta-3H]androstenedione (as measured by the release of tritiated water) showed a Km (Michaelis constant) of 78 nM. R 76,713 competitively inhibited aromatization with a Ki (dissociation constant of the enzyme-inhibitor complex) of 1.6 nM. In human adipose stromal cells aromatization was measured by following the conversion of androstenedione to estrone and 17 beta-estradiol. In this system a Km for aromatization of androstenedione of 10.8 nM was found. R 76,713 again showed competitive kinetics with a Ki-value of 0.14 nM. In human testicular cells the synthesis of the androgens testosterone, androstenedione and dehydroepiandrosterone was only inhibited by drug concentrations exceeding 10(-6) M. At 10(-5) M of R 76,713, steroid concentrations were lowered to 56, 64 and 81% of the control for testosterone, androstenedione and dehydroepiandrosterone respectively. Concomitantly, a slight increase in the levels of pregnenolone (138% of the control) and progesterone (133% of the control) was seen. In human adrenal cells the synthesis of cortisol and aldosterone was slightly affected by R 76,713 also at concentrations exceeding 10(-6) M. At 10(-5) M of R 76,713 the concentrations of cortisol and aldosterone were lowered to respectively 59 and 51% of the control. At the same drug concentration the precursors 11-deoxycortisol and 11-deoxycorticosterone rose to 189 and 147% of the control. These results show that in primary cultures of human cells, R 76,713 is a very potent aromatase inhibitor with a selectivity of at least 1000-fold compared to other steps in steroidogenesis.  相似文献   

8.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

9.
Gröschl M  Rauh M 《Steroids》2006,71(13-14):1097-1100
Saliva analysis is an accepted non-invasive alternative to plasma in pediatric endocrinology. Although commercial saliva collectors are available, the reliability of these devices for the analysis of salivary hormones has not been proved. We investigated the recovery and linearity of salivary steroids (cortisol, cortisone, 17-hyroxyprogesterone, testosterone, androstenedione) being relevant in endocrine research and therapy control. Pooled saliva was spiked with ascending concentrations of the steroids and applied onto a variety of absorbents, such as the cotton and the polyester (PE) Salivette (Sarstedt), the foam-tip applicator (Whatman) and strips of blood-spot collection paper (Whatman). Analysis was performed by LC-MS/MS. Best results were achieved using the PE Salivette, yielding recoveries (%) of 99.8 (cortisol), 98.7 (cortisone), 91.8 (17OHP), 96.3 (testosterone), 98.9 (androstendione) with a volume recovery of 98+/-1%. Using the blood-spot paper, recoveries (%) were 92.0 (cortisol), 89.1 (cortisone), 72.0 (17OHP), 70.3 (testosterone) and 77.1 (androstendione). The recovery of glucocorticoids was significantly higher compared to androgens (p<0.001). The recovery of liquid volume was 95+/-2%. The cotton Salivette yielded weak recoveries of 88.7 (cortisol), 86.2 (cortisone), 60.9 (17OHP), 62.0 (testosterone) and 72.4 (androstendione). The recovery of the glucocorticoids differed significantly from the androgens (p<0.001). Liquid recovery was most variable with 89+/-8%. The weakest recoveries were found in the foam-tips being 76.2 for cortisol, only 41.8 for cortisone, 31.1 for 17OHP, 38.5 for testosterone and 36.1 for androstendione. The volume recovery here was 97+/-1%. We assume only the PE version of the Salivette suitable for salivary steroid analysis. The weak recovery from the cotton version is a severe problem due to lacking comparability with values obtained with the polyester wads and the weak homogeneity as observed over a physiological concentration range.  相似文献   

10.
PM01218 is a novel marine-derived alkaloid and has shown potent growth inhibitory activity against several human cancer cell lines. A rapid and sensitive high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed and validated to quantify PM01218 in mouse and rat plasma. The lower limit of quantitation (LLOQ) was 0.05 ng/mL. The calibration curve was linear from 0.05 to 100 ng/mL (R(2)>0.999). The assay was specifically based on the multiple reaction monitoring (MRM) transitions at m/z 278.4-->184.2, no endogenous material interfaced with the analysis of PM01218 and its internal standard from blank mouse and rat plasma. The mean intra- and inter-day assay accuracy remained below 15 and 8%, respectively, for all calibration standards and QC samples. The intra- and inter-day assay precision was less than 12.8 and 8.5% for all QC levels, respectively. The utility of the assay was demonstrated by pharmacokinetics studies of i.v. (bolus) PM01218 on SD rats.  相似文献   

11.
Steroidogenesis was studied in guinea-pig glomerulosa-fasciculata cells maintained in primary culture for up to 7 days. The basal secretion which remained stable for the first 2 days in culture rapidly rose to reach a plateau on day 4 at levels 6-7-fold higher than those observed during the first 2 days of culture while the maximal response to ACTH in terms of cortisol and androstenedione secretion was fairly stable throughout the 7-day period. Exposure of glomerulosa-fasciculata cells to ACTH caused a stimulation of pregnenolone, 17-hydroxypregnenolone, progesterone, 17-hydroxyprogesterone, corticosterone, 11-deoxy-corticosterone, 11-deoxycortisol, cortisol, dehydroepiandrosterone, androstenedione, 11 beta-hydroxyandrostenedione and aldosterone while, after 48 h of incubation, a marked accumulation of end-products, namely cortisol and 11 beta-hydroxyandrostenedione, was observed. The half-maximal steroidogenic response to ACTH occurred at concentrations varying between 1.7 x 10(-11) and 1.1 x 10(-10) mol/l for the 12 steroids examined. Addition of 8-bromoadenosine 3', 5'-cyclic monophosphate stimulated steroid secretion in a dose-dependent manner. Maximal response to 8-bromoadenosine 3', 5'-cyclic monophosphate was obtained at 1 mmol/l, and no further rise of steroid secretion was observed after addition of ACTH. Incubation of glomerulosa-fasciculata cells with labeled corticosterone, cortisol and androstenedione indicates that only androstenedione can be converted into 11 beta-hydroxyandrostenedione, thus suggesting that this end-product is a good parameter of the C-19 steroid production by guinea-pig glomerulosa-fasciculata cells in primary culture. The present data confirm that guinea-pig glomerulosa-fasciculata cells in primary culture provide an interesting model for the study of the regulation of C-19 steroid formation by the adrenals.  相似文献   

12.
A sensitive and selective reversed-phase liquid chromatographic assay for tenofovir in human plasma has been developed and validated. Tenofovir was isolated from a 200 microl plasma sample using protein precipitation with trichloroacetic acid. The fluorescent 1,N(6)-etheno derivative is formed at 98 degrees C in the buffered extract with chloroacetaldehyde. This derivative was analysed using gradient ion-pair liquid chromatography and fluorescence detection at 254 nm for excitation and 425 nm for emission. In the evaluated concentration range (20-1000 ng/ml), the intra-day precision was 4% and the inter-day precision was 5-6%. An accuracy of between 97 and 110% was determined. The lower limit of quantification was 20 ng/ml with an inter-day precision of 11%, an intra-day precision of 12% and an accuracy of 103%. The assay is subject to interference from co-administered abacavir. The usefulness of the assay was demonstrated for samples obtained from an HIV-infected patient treated with tenofovir.  相似文献   

13.
A simple, sensitive and rapid method for the analysis of lumefantrine in rat plasma using liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) was developed. Detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The method included a chromatographic run of 5 min using a C18 analytical column and the calibration curve was linear over the concentration range of 2–500 ng/mL with a correlation coefficient (r) of 0.996 or better. The intra- and inter-day assay precision ranged from 1.5 to 7.5% and 5.5 to 7.7%, respectively, and intra- and inter-day assay accuracy was between 91.3–109.7% and 97.0–104.7%, respectively. The method was successfully applied for the pharmacokinetic study in rats.  相似文献   

14.
We have examined the metabolism in vitro of [4-14C]pregnenolone by the following organs of 2.4-year-old rats: submandibular gland, stomach, duodenum, liver, lung, heart, spleen, kidney, skin, prostate, testis and adrenal. All tissues converted pregnenolone to progesterone, the highest yields being observed with adrenal, testis and skin. Androgen formation was intense in the testis and absent in the adrenal. Moreover, 17-hydroxylation of pregnenolone occurred moderately in kidney, skin and submandibular gland and markedly in duodenum and stomach, which also produced high amounts of dehydroepiandrosterone and/or 5-androstene-3β,17β-diol. Extratesticular synthesis of androstenedione and testosterone was very low. A significant formation of 20-dihydropregnenolone was observed in all tissues but stomach, duodenum and steroidogenic endocrines. Corticosteroids were not synthesized extraadrenally, except a small amount of 11-deoxycorticosterone in the testis. These results indicate that key steroid-biosynthetic enzymes, such as 3β-hydroxysteroid dehydrogenase/Δ5′Δ4 isomerase, 17β- and 20-hydroxysteroid dehydrogenases and steroid 17-monooxygenase/17,20-lyase are also expressed extraglandularly in the rat.  相似文献   

15.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

16.
Slices of an adreno-cortical adenoma which had been obtained at operation from an 11-year-old girl with clinical signs of virilism were incubated with each of the following steroids: [1,2-3H]progesterone, [4-14C]pregnenolone, [1,2-3H]testosterone, [4-14C]androstenedione and [7-3H]dehydroepiandrosterone, respectively. Isolation and identification of the free radioactive metabolites were achieved by gel column chromatography on Sephadex LH-20, thin-layer chromatography, radio gas chromatography and isotope dilution. After incubation of progesterone, the following metabolites were identified: 11beta-hydroxyprogesterone, 16alpha-hydroxyprogesterone, 17alpha-hydroxyprogesterone, 21-deoxycortisol, corticosterone and cortisol. Pregnenolone was metabolized to 17alpha-hydroxypregnenolone, progesterone, dehydroepiandrosterone, androstenedione and 11beta-hydroxyandrostenedione. When testosterone was used as substrate, 11beta-hydroxytestosterone, androstenedione and 11beta-hydroxyandrostenedione were found as metabolites, whereas androstenedione was metabolized to testosterone and 11beta-hydroxyandrostenedione. After incubation of dehydroepiandrosterone, only androstenedione and 11beta-hydroxyandrostenedione were isolated and identified. From these results, it appears that cortisol was formed in the adenoma tissue via 21-deoxycortisol and corticosterone. Delta4-3oxo steroids of the C19-series arose exclusively from pregnenolone via 17alpha-hydroxypregnenolone and dehydroepiandrosterone, and not from progesterone and 17alpha-hydroxyprogesterone. Calculated on the amounts of metabolites formed, the highest enzyme activities were those of the 11beta-hydroxylase and the 17alpha-hydroxylase. It is interesting to note that only traces of testosterone were detected after incubation of androstenedione, whereas testosterone yielded large amounts of androstenedione.  相似文献   

17.
The metabolism of 7-(3)H-pregnenolone was studied in vitro using 16 human breast carcinomas. All mammary tumors transformed pregnenolone to progesterone. All estrogen receptor poor tumors and 4 out of 8 estrogen receptor rich tumors converted pregnenolone to 17-hydroxypregnenolone. Five estrogen receptor poor tumors showed the presence of 17,20-lyase as evidenced by formation of dehydroepiandrosterone and androstenedione. In two estrogen receptor poor tumors, conversions of pregnenolone to progesterone, 17-hydroxy pregnenolone, dehydroepiandrosterone, androstenedione and finally to estradiol was documented, providing a hypothetical pathway for steroid metabolism in human breast cancer. The conversion of pregnenolone to 17-hydroxypregnenolone was significantly less in receptor rich tumors and was totally absent in 4 receptor rich tumors with estrogen receptors of over 45 fmol/mg protein.  相似文献   

18.
A new chromatographic system for the steroid precursor separation and a sensitive radioimmunoassay system for the subsequent measurement of 18-hydroxy-11-deoxycorticosterone and 18-hydroxycorticosterone has been developed. 18-Hydroxy-11-deoxycorticosterone and 18-hydroxycorticosterone were extracted with methylene chloride and separated from cross-reacting steroids by Sephadex LH-20 column chromatography. Anti-18-hydroxy-11-deoxycorticosterone and anti-18-hydroxycorticosterone antibodies raised in rabbits were used. The lower detection limit of the assay is 0.03 nmol/l and 0.128 nmol/l for 18-hydroxy-11-deoxycorticosterone and 18-hydroxycorticosterone, respectively. Normal values for this assay in 128 healthy neonates and infants aged 0-5 months were established as a basis for the early hormonal diagnosis of aldosterone synthase deficiency types I and II. Its application for the diagnosis of aldosterone synthase deficiency is demonstrated in two patients with homozygous mutation/deletion in the encoding CYP11B2 gene.  相似文献   

19.
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 μL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.  相似文献   

20.
A LC-tandem mass spectrometry method to quantify the quinazoline-based thymidylate synthase inhibitors BGC945 and BGC638 in mouse plasma was developed. BGC945 and BGC638 were extracted from mouse plasma using protein precipitation with acetonitrile. Chromatography was performed on a Fluophase RP 5 microm, 100 mmx2.0mm i.d. column using a gradient of ammonium acetate and acetonitrile as a mobile phase with a flow rate of 0.2 mLmin(-1). The injection volume for each sample was 20 microL with a total run time of 7.5 min. This method was validated in the range 25-4000 nM (r2=0.99). The analytical assay performance showed that the method was accurate (mean intra- and inter-day assay R.E. were below 12% and 11%, respectively), reproducible (mean intra- and inter-day R.S.D. were less than 13% and 5% for all quality control levels, respectively) and sensitive (lower limit of quantification was 25 nM) in the range studied. This validated method has been used to define the first pharmacokinetic report of BGC945 and BGC638 in mice.  相似文献   