首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
IMAC in combination with mass spectrometry is a promising approach for global analysis of protein phosphorylation. Nevertheless this approach suffers from two shortcomings: inadequate efficiency of IMAC and poor fragmentation of phosphopeptides in the mass spectrometer. Here we report optimization of the IMAC procedure using (32)P-labeled tryptic peptides and development of MS/MS/MS (MS3) for identifying phosphopeptide sequences and phosphorylation sites. The improved IMAC method allowed recovery of phosphorylated tryptic peptides up to approximately 77% with only minor retention of unphosphorylated peptides. MS3 led to efficient fragmentation of the peptide backbone in phosphopeptides for sequence assignment. Proteomics of mitochondrial phosphoproteins using the resulting IMAC protocol and MS3 revealed 84 phosphorylation sites in 62 proteins, most of which have not been reported before. These results revealed diverse phosphorylation pathways involved in the regulation of mitochondrial functions. Integration of the optimized batchwise IMAC protocol with MS3 offers a relatively simple and more efficient approach for proteomics of protein phosphorylation.  相似文献   

2.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

3.
This paper reports on the selectivity behaviour of tryptic peptides on a Cu(2+)-loaded immobilised metal ion affinity chromatography (IMAC) support. Ovalbumin was chosen as a model protein for investigation of the selection and separation of histidine-containing peptides by IMAC off-line coupled with capillary electrophoresis and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF). Two of five histidine-containing peptides in addition to some non-histidine-containing peptides from a tryptic digest of ovalbumin were captured by IMAC. To separate and purify the selected peptides, the IMAC sample was analysed by capillary zone electrophoresis (CZE). The sample was not separated by capillary zone electrophoresis, therefore, micellar electrokinetic chromatography (MEKC) using 10-75 mM SDS was used. Analysis of IMAC sample by MEKC, using low concentrations of SDS (10 mM) was characterised by MALDI-TOF. When using SDS at 75 mM, the migration times of reversed-phase fractions of the IMAC sample, were used to identify the peaks. One of the two selected histidine-containing peptides with two histidine residues was identified, analysing the sample by CZE or MEKC.  相似文献   

4.
The applicability of a trypsin-based monolithic bioreactor coupled on-line with LC/MS/MS for rapid proteolytic digestion and protein identification is here described. Dilute samples are passed through the bioreactor for generation of proteolytic fragments in less than 10 min. After digestion and peptide separation, electrospray ionization tandem mass spectrometry is used to generate a peptide map and to identify proteolytic peptides by correlating their fragmentation spectra with amino acid sequences from a protein database. By digesting picomoles of proteins sufficient data from ESI and MS/MS were obtained to unambiguously identify proteins alone and in serum samples. This approach was also extended to locate mutation sites in beta-lactoglobulin A and B variants.  相似文献   

5.
Two-dimensional liquid chromatography (2D-LC) coupled on-line with electrospray ionization tandem mass spectrometry (2D-LC-ESI-MS/MS) is a new platform for analysis and identification of proteome. Peptides are separated by 2D-LC and then performed MS/MS analysis by tandem MS/MS. The MS/MS data are searched against database for protein identification. In one 2D-LC-ESI-MS/MS run, we obtained not only the structural information of peptides directly from MS/MS, but also the retention time of peptides eluted from LC. Information on the chromatographic behavior of peptides can assist protein identification in the new platform for proteomics. The retention time of the matching peptides of the identified protein was predicted by the hydrophobic contribute of each amino acid on reversed-phase liquid chromatography (RPLC). By using this strategy proteins were identified by four types of information: peptide mass fingerprinting (PMF), sequence query, and MS/MS ions searched and the predicted retention time. This additional information obtained from LC could assist protein identification with no extra experimental cost.  相似文献   

6.
A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 microl portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis HLB column (1 mm x 50 mm, 30 microm) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 microm). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x2) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degrees C. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos formulation (encapsulated 15 mg tablet) and an Actos 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos 15 mg tablet.  相似文献   

7.
The possibility of mass spectrometric sequencing of peptides without the need for the conventional MS/MS analysis has been demonstrated experimentally. The peptide hydrolysate was fractionated by reversephase chromatography on a microbore column. The eluate fraction was injected into the mass spectrometer via an electrospray ion source that directly coupled a liquid chromatography instrument to a time-of-flight mass spectrometer (HPLC-MS). Fragmentation of the peptides eluted from the column was performed in the mass spectrometer interface by varying the voltage difference between the mass spectrometer nozzle and skimmer. A restricted set of intensive peaks of y-ions, which corresponded to sequential cleavage of all amino acids from the peptide, was obtained. The ratios of the y-ion peak intensities to the background were (5?100)/1. The presence of Lys and Arg in the peptides provided for a substantial increase of informative peak intensity in the mass spectra. The mass spectra of short peptides (up to 10 residues) were processed manually, whereas the Proteos hardware and software system was used to process the fragmentation results for a long N-terminal peptide of the human hemoglobin α-chain.  相似文献   

8.
Phosphopeptides can be difficult to detect and sequence by mass spectrometry (MS) due to low ionization efficiency and suppression effects in the MS mode, and insufficient fragmentation in the tandem MS (MS/MS) mode, respectively. To address this problem, we have developed a technique called Phosphatase-directed Phosphorylation-site Determination (PPD), which combines on-target phosphatase reactions, MALDI MS/MS of IMAC beads on target, and hypothesis-driven MS (HD-MS). In this method, on-target dephosphorylation experiments are conducted on IMAC-bound phosphopeptides, because dephosphorylated peptides have, in general, higher MS sensitivities than the corresponding phosphopeptides. The detected dephosphorylated peptides are sequenced by MS/MS, which identifies the potentially phosphorylated peptide and the total number of Ser, Thr, or Tyr residues that could hypothetically be phosphorylated within that peptide. On the basis of this information, a mass list containing every possible phosphorylation state of each observed peptide (where 1 HPO(3) = 80 Da) is used to direct MALDI-MS/MS on the phosphorylated peptides bound to IMAC beads at each theoretical mass from the list. If the peptide is present, the resulting MS/MS spectrum reveals the exact site(s) of phosphorylation in the peptide. We have demonstrated the applicability of PPD to the detection of in vivo phosphorylation sites on the Drosophila Stem Loop Binding Protein (dSLBP), and the complementarity of this new technique to conventional MS phosphorylation site mapping methods, since the phosphorylation sites in dSLBP could not be detected by other methods.  相似文献   

9.
Phosphorylation is a reversible posttranslational protein modification which plays a pivotal role in intracellular signaling. Despite extensive efforts, phosphorylation site mapping of proteomes is still incomplete motivating the exploration of alternative methods that complement existing workflows. In this study, we compared tandem mass spectrometry (MS/MS) on matrix assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) and nano‐electrospray ionization (nESI) Orbitrap instruments with respect to their ability to identify phosphopeptides from complex proteome digests. Phosphopeptides were enriched from tryptic digests of cell lines using Fe‐IMAC column chromatography and subjected to LC‐MS/MS analysis. We found that the two analytical workflows exhibited considerable orthogonality. For instance, MALDI‐TOF MS/MS favored the identification of phosphopeptides encompassing clear motif signatures for acidic residue directed kinases. The extent of orthogonality of the two LC‐MS/MS systems was comparable to that of using alternative proteases such as Asp‐N, Arg‐C, chymotrypsin, Glu‐C and Lys‐C on just one LC‐MS/MS instrument. Notably, MALDI‐TOF MS/MS identified an unexpectedly high number and percentage of phosphotyrosine sites (~20% of all sites), possibly as a direct consequence of more efficient ionization. The data clearly show that LC‐MALDI MS/MS can be a useful complement to LC‐nESI MS/MS for phosphoproteome mapping and particularly so for acidic and phosphotyrosine containing peptides.  相似文献   

10.
Alaska pollock skin as aquatic by-product was usually discarded in food processing. Iron deficiency has been a nutritional problem for a long period. In this study, Alaska pollock skin was used to generate iron-chelating peptides after being treated by commercial enzymes. Sequential chromatography, including immobilized metal affinity chromatography (IMAC) and reversed phase high performance liquid chromatography (RP-HPLC), was used for capturing and purifying iron-chelating peptides. One tripeptide, with high iron-chelating activity, was obtained and identified by electrospray ionization tandem mass spectrometry (LC–ESI-MS/MS). The amino acid sequence of the iron-chelating peptide was identified to be Ser-Cys-His (MW: 345 Da). These results show that Alaska pollock skin could be utilized to generate iron-chelating peptides as an iron supplement in functional food industry.  相似文献   

11.
This study explored an alternative way to enrich and pre-purify biological samples containing nucleoside mono-, di- and triphosphates. These compounds were trapped by immobilised metal affinity chromatography (IMAC) on a Poros 20 MC IMAC-column, which was conditioned with Fe3+. The IMAC-column was implemented in a column switching set-up separating nucleoside mono-, di- and triphosphates on a Hypersil ODS 35 mm x 0.3 mm capillary column hyphenated to electrospray mass spectrometry resulting in the first miniaturised column switching liquid chromatography-mass spectrometry (LC-MS) system for nucleotides.  相似文献   

12.
In this study we systematically analyzed the elution condition of tryptic peptides and the characteristics of identified peptides in reverse phase liquid chromatography and electrospray tandem mass spectrometry (RPLC-MS/MS) analysis. Following protein digestion with trypsin, the peptide mixture was analyzed by on-line RPLC-MS/MS. Bovine serum albumin (BSA) was used to optimize acetonitrile (ACN) elution gradient for tryptic peptides, and Cytochrome C was used to retest the gradient and the sensitivity of LC-MS/MS. The characteristics of identified peptides were also analyzed. In our experiments, the suitable ACN gradient is 5% to 30% for tryptic peptide elution and the sensitivity of LC-MS/MS is 50 fmol.Analysis of the tryptic peptides demonstrated that longer (more than 10 amino acids) and multi-charge state ( 2, 3) peptides are likely to be identified, and the hydropathicity of the peptides might not be related to whether it is more likely to be identified or not. The number of identified peptides for a protein might be used to estimate its loading amount under the same sample background. Moreover, in this study the identified peptides present three types of redundancy, namely identification, charge, and sequence redundancy, which may repress low abundance protein identification.  相似文献   

13.
We describe a simple, fast, sensitive, and nonisotopic bioanalytical technique for the detection of tyrosine-phosphorylated peptides and the determination of sites of protein tyrosine phosphorylation. The technique employs a protein tyrosine phosphatase micro enzyme reactor coupled on-line to either capillary electrophoresis or liquid chromatography and electrospray ionization mass spectrometry instruments. The micro enzyme reactor was constructed by immobilizing genetically engineered, metabolically biotinylated human protein tyrosine phosphatase beta onto the inner surface of a small piece of a 50-microns inner diameter, 360-microns outer diameter fused silica capillary or by immobilization of the phosphatase onto 40-90-microns avidin-activated resins. By coupling these reactors directly to either a capillary electrophoresis column or a liquid chromatography column, we were able to rapidly perform enzymatic dephosphorylation and separation of the reaction products. Detection and identification of the components of the reaction mixture exiting these reactors were done by mass analysis with an on-line electrospray ionization mass spectrometer. Tyrosine-phosphorylated peptides, even if present in a complex peptide mixture, were identified by subtractive analysis of peptide patterns generated with or without phosphatase treatment. Two criteria, namely a phosphatase-induced change in hydropathy and charge, respectively, and a change in molecular mass by 80 Da, were used jointly to identify phosphopeptides. We demonstrate that, with this technique, low picomole amounts of a tyrosine-phosphorylated peptide can be detected in a complex peptide mixture generated by proteolysis of a protein and that even higher sensitivities can be realized if more sensitive detection systems are applied.  相似文献   

14.
A proteome of a model organism, Caenorhabditis elegans, was analyzed by an integrated liquid chromatography (LC)-based protein identification system, which was constructed by microscale two-dimensional liquid chromatography (2DLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS/MS) on a high-resolution hybrid mass spectrometer with an automated data analysis system. Soluble and insoluble protein fractions were prepared from a mixed growth phase culture of the worm C. elegans, digested with trypsin, and fractionated separately on the 2DLC system. The separated peptides were directly analyzed by on-line ESI-MS/MS in a data-dependent mode, and the resultant spectral data were automatically processed to search a genome sequence database, wormpep 66, for protein identification. The total number of proteins of the composite proteome identified in this method was 1,616, including 110 secreted/targeted proteins and 242 transmembrane proteins. The codon adaptation indices of the identified proteins suggested that the system could identify proteins of relatively low abundance, which are difficult to identify by conventional 2D-gel electrophoresis (GE) followed by an offline mass spectrometric analysis such as peptide mass fingerprinting. Among the approximately 5,400 peptides assigned in this study, many peptides with post-translational modifications, such as N-terminal acetylation and phosphorylation, were detected. This expression profile of C. elegans, containing 571 hypothetical gene products, will serve as the basic data of a major proteome set expressed in the worm.  相似文献   

15.
We report the use of microbore reverse-phase high performance liquid chromatography connected on-line to an electrospray mass spectrometer for the separation/detection of peptides derived by proteolytic digestion of proteins separated by polyacrylamide gel electrophoresis. A small fraction (typically 10% of the total) of the peptides eluting from the column was diverted through a flow-splitting device into the ion source of the mass spectrometer, whereas the majority of the peptide samples was collected for further analyses. We demonstrate the feasibility of obtaining reproducible peptide maps from submicrogram amounts of protein applied to the gel and good correlation of the signal detected by the mass spectrometer with peptide detection by UV absorbance. Furthermore, independently verifiable peptide masses were determined from subpicomole amounts of peptides directed into the mass spectrometer. The method was used to analyze the 265-kDa and the 280-kDa isoforms of the enzyme acetyl-CoA carboxylase isolated from rat liver. The results provide compelling evidence that the two enzyme isoforms are translation products of different genes and suggest that these approaches may be of general utility in the definitive comparison of protein isoforms. We furthermore illustrate that knowledge of peptide masses as determined by this technique provides a major advantage for error-free data interpretation in chemical high-sensitivity peptide sequence analysis.  相似文献   

16.
Identification of peptides from a complex mixture can be difficult because of the wide concentration range and the different ionization efficiencies of peptides during analysis by electrospray ionization (ESI) mass spectrometry (MS). Preconcentration methods are necessary to allow low-abundance and low-intensity peptides to reach the ionization threshold of the mass spectrometer. Here we demonstrate peptide enrichment based on electroimmobilization. Peptides are immobilized without the use of solid support or chemical binding by application of an electric field along a microflow stream in an electrocapture cell. Once enriched/preconcentrated inside the cell, they are released by removal of the electric field and via an interface with an electrospray emitter are submitted to online mass spectrometric analysis. Tandem mass spectrometric analysis of a peptide mixture containing hemoglobin, myoglobin, bovine serum albumin (BSA), and cytochrome c was successful. Amplification factors up to 16-fold were achieved with improvement of the signal-to-noise values for the preconcentrated sample. The limit of detection for one of the preconcentrated peptides was 3.6 fmol.  相似文献   

17.
A selective fluorescence reaction for peptides and chromatographic analysis   总被引:1,自引:0,他引:1  
Kabashima T  Yu Z  Tang C  Nakagawa Y  Okumura K  Shibata T  Lu J  Kai M 《Peptides》2008,29(3):356-363
A novel and selective fluorescence reaction is proposed for the quantitative determination of peptides by reversed-phase liquid chromatography (RPLC). A single fluorescent product was formed when a peptide was heated at 120 degrees C for 20 min in a neutral aqueous medium (pH 7.0) containing catechol, sodium periodate, and sodium borate. The fluorescent products of four peptides such as Leu-Gly, Ala-Leu-Gly, Tyr-Gly-Gly-Phe-Leu, and Leu-Leu-Leu were easily separated on a reversed-phase column by gradient elution of methanol in a mobile phase containing sodium borate (pH 7.0), and then quantitatively detected by fluorimetry. The lower limits (S/N=3) of the detection for the tested peptides were 0.5-1.0 pmol per an injection volume (40 microl). In addition, the fluorescent products of phenylalanine amide and Leu-Leu-Leu were identified by electrospray ionization-time of flight-mass spectrometry (ESI-TOF/MS) for the elucidation of their chemical structures.  相似文献   

18.
A method for the quantification of two peptide HIV-1 fusion inhibitors (enfuvirtide, T-20 and tifuvirtide, T-1249) and one metabolite of enfuvirtide (M-20) in human plasma has been developed and validated, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS). The analytes were extracted from plasma by solid-phase extraction (SPE) on vinyl-copolymer cartridges. Chromatographic separation of the peptides was performed on a Symmetry 300 C(18) column (50mmx2.1mm I.D., particle size 3.5 microm), using a water-acetonitrile gradient containing 0.25% (v/v) formic acid. The triple quadrupole mass spectrometer was operated in the positive ion-mode and multiple reaction monitoring (MRM) was used for peak detection. Deuterated (d60) enfuvirtide and (d50) tifuvirtide were used as internal standards. The assay was linear over a concentration range of 20-10,000 ng/ml for enfuvirtide and tifuvirtide and of 20-2000 ng/ml for M-20. Intra- and inter-assay precisions and deviations from the nominal concentrations were 相似文献   

19.
The nonenzymatic digestion of proteins by microwave D-cleavage is an effective technique for site-specific cleavage at aspartic acid (D). This specific cleavage C-terminal to D residues leads to inherently large peptides (15-25 amino acids) that are usually relatively highly charged (above +3) when ionized by electrospray ionization (ESI) due to the presence of several basic amino acids within their sequences. It is well-documented that highly charged peptide ions generated by ESI are well-suited for electron transfer dissociation (ETD), which produces c- and z-type fragment ions via gas-phase ion/ion reactions. In this paper, we describe the sequence analysis by ETD tandem mass spectrometry (MS/MS) of multiply charged peptides generated by microwave D-cleavage of several standard proteins. Results from ETD measurements are directly compared to CID MS/MS of the same multiply charged precursor ions. Our results demonstrate that the nonenzymatic microwave D-cleavage technique is a rapid (<6 min) and specific alternative to enzymatic cleavage with Lys-C or Asp-N to produce highly charged peptides that are amenable to informative ETD.  相似文献   

20.
Yu Y  Hu J  Miyaguchi Y  Bai X  Du Y  Lin B 《Peptides》2006,27(11):2950-2956
Animal blood is potentially an untapped source of drugs and value-added food production. More than 400 million pigs are slaughtered each year but porcine blood is usually discarded in China. This study describes the isolation and characterization of angiotensin I-converting enzyme (ACE) inhibitory peptides derived from porcine hemoglobin. The most active hydrolysate was obtained from the peptic digestion of porcine hemoglobin. After the purification of ACE-inhibitory peptides with Sephadex LH-20 gel chromatography and reversed-phase high-performance liquid chromatography (RP-HPLC) on C(18) column, two active fractions were obtained. They were analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS). They were LGFPTTKTYFPHF and VVYPWT, corresponding to the 34-46 fragment of the alpha chain and the 34-39 fragment of the beta chain of porcine hemoglobin, with IC(50) values of 4.92 and 6.02 microM, respectively. They were the first found from porcine hemoglobin; in particular, LGFPTTKTYFPHF was a novel ACE-inhibitory peptide. In addition, the purified ACE inhibitors both competitively inhibited ACE, and maintained inhibitory activity even after incubation with gastrointestinal proteases. This suggests that these peptides might have a potential antihypertensive effect.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号