首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It is of great significance to develop an effective method for methyl parathion (MP) detection. Herein, a novel nitrogen-doped titanium carbide quantum dots (N-Ti3C2 QDs) was prepared and used to construct a simple and sensitive fluorescence sensing platform of MP by making use of inner filter effect (IFE). The prepared N-Ti3C2 QDs can exhibit strong blue fluorescence at 434 nm. Meanwhile, MP could hydrolyze to produce p-nitrophenol (p-NP) under alkaline conditions, which showed a characteristic ultraviolet-visible (UV-visible) absorption peak at 405 nm, resulting in the fluorescence of N-Ti3C2 QDs is effectively quenched by p-NP. In addition, the investigation of time-resolved fluorescence decays indicated that the corresponding quenching mechanism of p-NP on N-Ti3C2 QDs is due to the IFE. After optimizing the conditions, the as-developed fluorescence sensing platform displayed wide detection range (0.1–30 μg mL−1) and low detection limit (0.036 μg mL−1) for MP, and it was also successfully applied for MP analysis in real water samples, thus it is expected that this simple, sensitive and enzyme-free sensing platform shows great applications.  相似文献   

2.
The sensitive and reliable detection of Hg2+ and CN as harsh environmental contaminants are of great importance. In view of this, a novel ‘on–off–on’ fluorescent probe based on nitrogen-rich silicon quantum dots (NR-SiQDs) has been designed for sensitive detection of Hg2+ and CN ions in aqueous medium. NR-SiQDs were synthesized using a facile, one-step, and environment friendly procedure in the presence of 3-aminopropyl trimethoxysilane (APTMS) and ascorbic acid (AA) as precursors, with l -asparagine as a nitrogen source for surface modification. The NR-SiQDs exhibited strong fluorescence emission at 450 nm with 42.34% quantum yield, satisfactory salt tolerance, and superior photostability and pH stability. The fluorescence emission was effectively quenched using Hg2+ (turn-off) due to the formation of a nonfluorescent stable NR-SiQDs/Hg2+ complex, whereas after the addition of cyanide ions (CN), Hg2+ ions could be leached from the surface of the NR-SiQDs and the fluorescence emission intensity of the quenched NR-SiQDs fully recovered (turn-on) due to the formation of highly stable [Hg(CN)4]2− species. After optimizing the response conditions, the obtained limits of detection were found to be 53 nM and 0.46 μM for Hg2+ and CN, respectively. Finally, the NR-SiQD-based fluorescence probe was utilized to detect Hg2+ and CN ions in water samples and satisfactory results were obtained, suggesting its potential application for environmental monitoring.  相似文献   

3.
The use of bacterial cells to produce fluorescent semiconductor nanoparticles (quantum dots, QDs) represents a green alternative with promising economic potential. In the present work, we report for the first time the biosynthesis of CdS QDs by acidophilic bacteria of the Acidithiobacillus genus. CdS QDs were obtained by exposing A. ferrooxidans, A. thiooxidans and A. caldus cells to sublethal Cd2+ concentrations in the presence of cysteine and glutathione. The fluorescence of cadmium-exposed cells moves from green to red with incubation time, a characteristic property of QDs associated with nanocrystals growth. Biosynthesized nanoparticles (NPs) display an absorption peak at 360 nm and a broad emission spectra between 450 and 650 nm when excited at 370 nm, both characteristic of CdS QDs. Average sizes of 6 and 10 nm were determined for green and red NPs, respectively. The importance of cysteine and glutathione on QDs biosynthesis in Acidithiobacillus was related with the generation of H2S. Interestingly, QDs produced by acidophilic bacteria display high tolerance to acidic pH. Absorbance and fluorescence properties of QDs was not affected at pH 2.0, a condition that totally inhibits the fluorescence of QDs produced chemically or biosynthesized by mesophilic bacteria (stable until pH 4.5–5.0). Results presented here constitute the first report of the generation of QDs with improved properties by using extremophile microorganisms.  相似文献   

4.
A flow injection chemiluminescence (FI–CL) method was developed for the determination of cyanide (CN) based on the recovered CL signal by Cu2+ inhibiting a glutathione (GSH)‐capped CdTe quantum dot (QD) and hydrogen peroxide system. In an alkaline medium, strong CL signals were observed from the reaction of CdTe QDs and H2O2, and addition of Cu2+ could cause significant CL inhibition of the CdTe QDs–H2O2 system. In the presence of CN, Cu2+ can be removed from the surface of CdTe QDs via the formation of particularly stable [Cu(CN)n](n‐1)– species, and the CL signal of the CdTe QDs–H2O2 system was efficiently recovered. Thus, the CL signals of CdTe QDs–H2O2 system were turned off and turned on by the addition of Cu2+ and CN, respectively. Further, the results showed that among the tested ions, only CN could recover the CL signal, which suggested that the CdTe QDs–H2O2–Cu2+ CL system had highly selectivity for CN. Under optimum conditions, the CL intensity and the concentration of CN show a good linear relationship in the range 0.0–650.0 ng/mL (R2 = 0.9996). The limit of detection for CN was 6.0 ng/mL (3σ). This method has been applied to detect CN in river water and industrial wastewater with satisfactory results. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Core–shell structured quantum dot (QD)–silica fluorescent nanoparticles have attracted a great deal of attention due to the excellent optical properties of QDs and the stability of silica. In this study, core–shell structured CdTe/CdS@SiO2@CdTe@SiO2 fluorescent nanospheres were synthesized based on the Stöber method using multistep silica encapsulation. The second silica layer on the CdTe QDs maintained the optical stability of nanospheres and decreased adverse influences on the probe during subsequent processing. Red‐emissive CdTe/CdS QDs (630 nm) were used as a built‐in reference signal and green‐emissive CdTe QDs (550 nm) were used as a responding probe. The fluorescence of CdTe QDs was greatly quenched by added S2?, owing to a S2?‐induced change in the CdTe QDs surface state in the shell. Upon addition of Cd2+ to the S2?‐quenched CdTe/CdS@SiO2@CdTe@SiO2 system, the responding signal at 550 nm was dramatically restored, whereas the emission at 630 nm remained almost unchanged; this response could be used as a ratiometric ‘off–on’ fluorescent probe for the detection of Cd2+. The sensing mechanism was suggested to be: the newly formed CdS‐like cluster with a higher band gap facilitated exciton/hole recombination and effectively enhanced the fluorescence of the CdTe QDs. The proposed probe shows a highly sensitive and selective response to Cd2+ and has potential application in the detection of Cd2+ in environmental or biological samples.  相似文献   

6.
Glibenclamide (GB), as a sulfonylurea‐based medication is commonly prescribed for the treatment of type 2 diabetes. Due to its increasing consumption, there is a need to develop a simple, fast, and reliable detection method to follow its concentration in pharmaceutical and biological samples. Herein, a novel fluorometric method is developed for the sensitive measurement of GB. The method is based on the enhancing effect of GB on the fluorescence emission of mercaptopropionic acid (MPA) capped cadmium telluride quantum dots (CdTe QDs). QDs were synthesized in aqueous solution and were characterized by fluorescence spectroscopy, transmission electron microscopy (TEM), X‐ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT‐IR). Fluorescence intensity of QDs was enhanced by adding GB in a very low concentration. The effect of operative factors such as pH, buffer, contact time and concentration of CdTe QDs were investigated and in the optimized condition, a linear increase was achieved for the emission intensity of QDs by increasing GB concentration in the range 49–345 ng mL?1, with a detection limit of 17.84 ng mL?1. The offered method has an acceptable precision (relative standard deviations were < 2.8%) and was satisfactorily applied for the determination of GB in pharmaceutical products and human urine samples.  相似文献   

7.
A rapid and sensitive immunoassays of mercury (Hg) in biological samples was developed using quantum dots (QDs) and magnetic beads (MBs) as fluorescent and separated probes, respectively. A monoclonal antibody (mAb) that recognizes an Hg detection antigen (BSA-DTPA-Hg) complex was produced by the injection of BALB/c mice with an Hg immunizing antigen (KLH-DTPA-Hg). Then the ascites monoclonal antibodies were purified. The Hg monoclonal antibody (Hg-mAb) is conjugated with MBs to separate Hg from biological samples, and the other antibody, which is associated with QDs, is used to detect the fluorescence. The Hg in biological samples can be quantified using the relationship between the QDs fluorescence intensity and the concentration of Hg in biological samples following magnetic separation. In this method, the detection linear range is 1–1000 ng/mL, and the minimum detection limit is 1 ng/mL. The standard addition recovery rate was 94.70–101.18%. The relative standard deviation values were 2.76–7.56%. Furthermore, the Hg concentration can be detected in less than 30 min, the significant interference of other heavy metals can be avoided, and the simultaneous testing of 96 samples can be performed. These results indicate that the method could be used for rapid monitoring Hg in the body.  相似文献   

8.
Mercaptopropionic acid (MPA)–capped cadmium telluride (CdTe) quantum dot (QDs) fluorescent probes were synthesized in aqueous solution and used for the determination of salicylic acid. The interaction between the MPA–capped CdTe QDs and salicylic acid was studied using fluorescence spectroscopy and some parameters that could modify the fluorescence were investigated to optimize the measurements. Under optimum conditions, the quenched fluorescence intensity of MPA–capped CdTe QDs was linearly proportional to the concentration of salicylic acid in the range of 0.5–40 µg mL–1 with a coefficient of determination of 0.998, and the limit of detection was 0.15 µg mL–1. The method was successfully applied to the determination of salicylic acid in pharmaceutical products, and satisfactory results were obtained that were in agreement with both the high pressure liquid chromatography (HPLC) method and the claimed values. The recovery of the method was in the range 99 ± 3% to 105 ± 9%. The proposed method is simple, rapid, cost effective, highly sensitivity and eminently suitable for the quality control of pharmaceutical preparation. The possible mechanisms for the observed quenching reaction was also discussed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
The synthesis of small-sized quantum dots (QDs) (1–10 nm) via the green route has garnered great interest regarding their prospective use in many biological applications (diagnosis, drug delivery and in vivo sensing); this is difficult to achieve using chemical synthesis methods, which produce larger size QD particles and also require hazardous reagents. Here, we synthesized biogenic cadmium sulphide (CdS) QDs using green tea extract as the reducing agent to produce particles that were homogeneous and a smaller size of 2–4 nm. We also elucidated the (a) protein binding, (b) antibacterial use and (c) sensing applications of biogenic CdS QDs in this present work. The biosynthesized CdS QDs were found to have extensive antibacterial activity against both Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial strains. The introduction of QDs in biological medium can lead to the formation of protein–QD complexes; therefore we investigated the binding interaction of CdS QDs with the carrier protein human serum albumin (HSA) in vitro. The synthesized CdS QDs quenched the intrinsic fluorescence of HSA through a static quenching mechanism and the binding constant (Kb) was in the order of 104 M−1. It was also observed that the presence of biogenic CdS QDs affected the HSA–ligand interactions in vitro. The synthesized CdS made highly effective sensors for tetracycline, rifampicin, and bilirubin with limit of detection (LOD) values of 99, 141 and 29 ng/ml, respectively.  相似文献   

10.
In this study, we developed a novel simple fluorescence resonance‐energy transfer (FRET) system between two‐color CdTe quantum dots (QDs) assisted by cetyltrimethylammonium bromide (CTAB). Mercaptopropionic (MPA)‐capped CdTe QDs serving as both donors and acceptors were successfully synthesized by changing the refluxing time in aqueous solution. CTAB micelles formed in water and minimized the distance between the donors and acceptors significantly by electrostatic interactions, improving FRET efficiency. Several factors that affected the fluorescence spectra of the FRET system were investigated. The prepared FRET system was feasible as an effective fluorescent probe to detect Hg(II) in aqueous solution. At pH 7.0, a linear relationship between the quenched fluorescence intensity of orange‐emitting acceptors (QDs(A)) and Hg(II) concentration was acquired in the range 5–250 nmol/L with a detection limit of 1.95 nmol/L. The developed method showed excellent analytical performance for Hg(II) with high sensitivity and acceptable selectivity, reproducibility and stability. This finding indicated that the method has a promising potential application for environmental monitoring. This study demonstrated the great promise of QDs for expedient, low‐cost and high‐sensitivity detection of Hg(II).  相似文献   

11.
d ‐penicillamine‐capped cadmium telluride quantum dots (DPA‐capped CdTe QDs) were synthesized as the new fluorescent semiconductor nanocrystal in aqueous solution. Fourier transmission infrared spectroscopy, X‐ray diffraction, transmission electron microscopy, ultraviolet‐visible and photoluminescence spectroscopy were used for characterization of the QDs. Based on the quenching effect of Cu2+ ions on the fluorescence intensity of DPA‐capped CdTe QDs, a new fluorometric sensor for copper(II) detection was developed that showed good linearity over the concentration range 5 × 10–9–3 × 10–6 m with the detection limit 0.4 × 10–9 m . Owing to the strong affinity of the DPA to copper(II), the sensor showed appropriate selectivity for copper(II) compared with conventional QDs. The DPA‐capped CdTe QDs was successfully applied for determination of Cu2+ concentration in river, well and tap waters with satisfactory results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
The interactions of N‐acetyl‐L‐cysteine‐capped CdTe quantum dots (QDs) with bovine serum albumin (BSA) and bovine hemoglobin (BHb) were investigated by isothermal titration calorimetry (ITC), fluorescence, synchronous fluorescence, fluorescence lifetime, ultraviolet–visible absorption, and circular dichroism techniques. Fluorescence data of BSA–QDs and BHb–QDs revealed that the quenching was static in every system. While CdTe QDs changed the microenvironment of tryptophan in BHb, the microenvironment of BSA kept unchanged. Adding CdTe QDs affected the skeleton and secondary structure of the protein (BSA and BHb). The ITC results indicated that the interaction between the protein (BSA and BHb) and QDs‐612 was spontaneous and the predominant force was hydrophobic interaction. In addition, the binding constants were determined to be 1.19 × 105 L mol?1 (BSA–QDs) and 2.19 × 105 L mol?1 (BHb–QDs) at 298 K. From these results, we conclude that CdTe QDs have a larger impact on the structure of BHb than BSA.  相似文献   

13.
In the present work, an improved class of protein functionalized fluorescent 2D Ti3C2 MXene quantum dots (MXene QDs) was prepared using a hydrothermal method. Exfoliated 2D Ti3C2 sheets were used as the starting precursor and transport protein bovine serum albumin (BSA) was used to functionalize the MXene QDs. BSA-functionalized MXene QDs exhibited excellent photophysical property and stability at various physiological parameters. High-resolution transmission electron microscopy analysis showed that the BSA@MXene QDs were quasispherical in shape with a size of ~2 nm. The fluorescence intensity of BSA@MXene QDs was selectively quenched in the presence of Fe3+ ions. The mechanism of fluorescence quenching was further substantiated using time-resolved fluorescence and Stern–Volmer analysis. The sensing assay showed a linear response within the concentration range 0–150 μM of Fe3+ ions with excellent limit of detection. BSA@MXene QDs probe showed good selectivity toward ferric ions even in the presence of other potential interferences. The practical applicability of BSA@MXene QDs was further tested in real samples for Fe3+ ion quantification and the sensor had good recovery rates. The cytotoxicity studies of the BSA@MXene QDs toward the human glioblastoma cells revealed that BSA@MXene QDs are biocompatible at lower doses and showed significant cytotoxicity at higher dosages.  相似文献   

14.
A rapid, simple and sensitive label‐free fluorescence method was developed for the determination of trace amounts of an important drug, heparin. This new method was based on water‐soluble glutathione‐capped CdTe quantum dots (CdTe QDs) as the luminescent probe. CdTe QDs were prepared according to the published protocol and the sizes of these nanoparticles were verified through transmission electron microscopy (TEM), X‐ray diffraction (XRD) and dynamic light scattering (DLS) with an average particle size of about 7 nm. The fluorescence intensity of glutathione‐capped CdTe QDs increased with increasing heparin concentration. These changes were followed as the analytical signal. Effective variables such as pH, QD concentration and incubation time were optimized. At the optimum conditions, with this optical method, heparin could be measured within the range 10.0–200.0 ng mL?1 with a low limit of detection, 2.0 ng mL?1. The constructed fluorescence sensor was also applied successfully for the determination of heparin in human serum. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
A swim tunnel is to fish as a treadmill is to humans, and is a device used for indirect measuring of the metabolic rate. This study aims to explore the fish stress (if any) during the critical swimming test routines (fish handling, confinement, and swimming) using heart rate (fH, heartbeat per minute) bio-loggers in farmed Atlantic salmon (Salmo salar L.). In addition, the recovery dynamics of exercised fish using fH were explored for 48 h post swim tests. Continuous fH data were acquired following the surgical implantation and throughout the trials, such as during fish handling, swim tests (critical swimming speed, Ucrit), and 48 h post swim tests. After 3 weeks of surgical recovery, fH stabilized at 46.20 ± 1.26 beats min−1, equalizing a ~38% reduction in fH recorded post-surgical tachycardia (74.13 ± 1.44 beats min−1). Interestingly, fH was elevated by ~200% compared to baseline levels not only due to the Ucrit (92.04 ± 0.23 beats min−1) but also due to fish handling and confinement in the swim tunnel, which was 66% above the baseline levels (77.48 ± 0.34 beats min−1), suggesting fish stress. Moreover, significantly higher plasma cortisol levels (199.56 ± 77.17 ng mL−1) corresponding to a ~300% increase compared to baseline levels (47.92 ± 27.70 ng mL−1) were identified after Ucrit, predicting post-swim test stress (physiological exhaustion). These findings reinforce the importance of fish acclimation in the swim tunnel prior to the swimming tests. However, fH dropped over the course of the 48-h post-swim test, but remained comparatively higher than the basal levels, suggesting fish should be given at least 48 h to recover from handling stress for better fish welfare. This study further explored the influence of fish tagging on Ucrit, which resulted in reduced swimming capabilities of tagged fish (1.95 ± 0.37 body lengths s−1) compared to untagged fish (2.54 ± 0.42 body length s−1), although this was not significant (p = 0.06), and therefore future tagging studies are warranted.  相似文献   

16.
CdTe quantum dots (QDs) capped with different stabilizers, i.e. thioglycolic acid (TGA), 3‐mercaptopropionic acid (MPA) and glutathione (GSH) were investigated as fluorescent probes for the determination of Cu2+. The stabilizer was shown to play an important role in both the sensitivity and selectivity for the determination of Cu2+. TGA‐capped CdTe QDs showed the highest sensitivity, followed by the MPA and GSH‐capped CdTe QDs, respectively. The TGA‐ and MPA‐capped CdTe QDs were not selective for Cu2+ that was affected by Ag+. The GSH‐capped CdTe QDs were insensitive to Ag+ and were used to determine Cu2+ in water samples. Under optimal conditions, quenching of the fluorescence intensity (F0/F) increased linearly with the concentration of Cu2+ over a range of 0.10–4.0 µg/mL and the detection limit was 0.06 µg/mL. The developed method was successfully applied to the determination of Cu2+ in water samples. Good recoveries of 93–104%, with a relative standard deviation of < 6% demonstrated that the developed simple method was accurate and reliable. The quenching mechanisms were also described. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The suggested study adheres to a particular protocol to ensure that the process is environmentally friendly and sustainable. It is worth mentioning that several tools have been adopted as prospective measures of the method greenness. Fortunately, the established analytical method is identified as white by the white analytical chemistry (WAC) concept, which uses the red/ green/blue color scheme (RGB 12 tool) to combine ecological and functional factors for the first time in studying of the cited drug. Amlodipine (AMD), a cardiovascular treating agent, belongs to the dihydropyridine class of oral calcium channel-blocking agents. This article presents a novel, simple, green, one-pot-processed, fast, and ultrasensitive fluorimetric approach for monitoring and assessment of AMD using molecular-size-dependent fluorescence augmentation of the light scattering-driven signal of eosin, a biological stain at a wavelength of 415 nm. This enhancement was directly proportional to the size of the produced complex. The linearity range was from 30 to 900 ng mL−1, with corresponding sensitivity limits (detection and quantitation levels) of 9.2 and 28 ng mL−1, respectively. The planned approach was also successfully used to track AMD content in bulk, dosage forms, and bio-fluids (human plasma and urine). The developed method's eco-friendliness was established by different eco-rating metric tools.  相似文献   

18.
Cysteamine (CA)‐capped CdTe quantum dots (QDs) (CA–CdTe QDs) were prepared by the reflux method and utilized as an efficient nano‐sized fluorescent sensor to detect mercury (II) ions (Hg2+). Under optimum conditions, the fluorescence quenching effect of CA–CdTe QDs was linear at Hg2+ concentrations in the range of 6.0–450 nmol/L. The detection limit was calculated to be 4.0 nmol/L according to the 3σ IUPAC criteria. The influence of 10‐fold Pb2+, Cu2+ and Ag+ on the determination of Hg2+ was < 7% (superior to other reports based on crude QDs). Furthermore, the detection sensitivity and selectivity were much improved relative to a sensor based on the CA–CdTe QDs probe, which was prepared using a one‐pot synthetic method. This CA–CdTe QDs sensor system represents a new feasibility to improve the detection performance of a QDs sensor by changing the synthesis method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Novel direct and indirect competitive fluorescence‐linked immunosorbent assays (c FLISA and ic FLISA) for detection of ochratoxin A (OTA) were described using CdTe quantum dots (QDs) as fluorescent label. CdTe QDs were successfully synthesized, which had an emission wavelength of 615 nm. The high purity monoclonal antibody against OTA was prepared through cell thawing and the octylic acid‐ammonium sulfate method. The OTA MAbs were successfully coupled with CdTe QDs, and which also retained the original biological activity. The 50% inhibition values (IC50) of the c FLISA and ic FLISA were 0.630 ng/mL, 0.234 ng/mL, the limits of detection (LOD) were 7.06 × 10–3 and 4.15 × 10–3 ng/mL, and detection ranges were 7.06 × 10–3 ? 18.34 ng/mL and 4.15 × 10–3 ? 4.88 ng/mL, in‐order. The recoveries were 96.0–104.7% along with coefficients of variation (CVs) below 10%. The FLISA provided novel method for determination of OTA and the potential of MAb–CdTe QDs for the establishment of fluorescent immunochromatographic test strip.

  相似文献   


20.
In this study, CdS quantum dots (QDs) capped with mercaptosuccinic acid (MSA) were prepared in one step. The size, shape, component and spectral properties of MSA‐capped CdS QDs were characterized by transmission electron microscopy (TEM), photoluminescence (PL) and infrared (IR) spectrometry. The results showed that the prepared QDs with an average diameter of 6 nm have favorable fluorescence, which is greatly influenced by the pH of the environment. The interaction of some heavy metal ions including Ag+, Hg2+, Cu2+, Ni2+ and Co2+ with MSA‐capped CdS QDs was investigated in different buffering pH media. Based on the fluorescence quenching of the QDs in the presence of each of the metal ions, the feasibility of their determinations was examined according to the Stern–Volmer equation. The investigations showed that Hg(II) ions can be determined in the presence of many co‐existing metal ions at a buffering pH of 5. This method was satisfactorily applied to the measurement of Hg(II) ions in some environmental samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号