首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper describes an HPLC method for the determination of tramadol and its major active metabolite, O-desmethyltramadol (ODT), in human plasma. Sample preparation involved liquid-liquid extraction with diethyl ether-dichloromethane-butanol (5:3:2, v/v/v) and back extraction with sulphuric acid. Tramadol, ODT and the internal standard, sotalol, were separated by reversed phase HPLC using 35% acetonitrile and an aqueous solution containing 20 mM sodium phosphate buffer, 30 mM sodium dodecyl sulphate and 15 mM tetraethylammonium bromide pH 3.9. Detection was by fluorescence with excitation and emission wavelengths of 275 and 300 nm, respectively. The method was linear for tramadol (3-768 ng/ml) and ODT (1.5-384 ng/ml) with mean recoveries of 87.2% and 89.8%, respectively. Intra- and inter-day precisions were 10.34% and 8.43% for tramadol and 9.43% and 8.75% for ODT at the respective limits of quantitation (3 and 1.5 ng/ml). Accuracy for tramadol ranged from 96.2% to 105.3%. The method was applied to a pharmacokinetic study of tramadol in human volunteers.  相似文献   

2.
Tramadol, an analgesic agent, and its two main metabolites O-desmethyltramadol (M1) and N-desmethyltramadol (M2) were determined simultaneously in human plasma by a rapid and specific HPLC method. The sample preparation was a simple extraction with ethyl acetate. Chromatographic separation was achieved with a Chromolith Performance RP-18e 50 mm x 4.6 mm column, using a mixture of methanol:water (13:87, v/v) adjusted to pH 2.5 by phosphoric acid, in an isocratic mode at flow rate of 2 ml/min. Fluorescence detection (lambda(ex)=200 nm/lambda(em)=301 nm) was used. The calibration curves were linear (r(2)>0.997) in the concentration range of 2.5-500 ng/ml, 1.25-500 ng/ml and 5-500 ng/ml for tramadol, M1 and M2, respectively. The lower limit of quantification was 2.5 ng/ml for tramadol, 1.25 ng/ml for M1 and 5 ng/ml for M2. The within- and between-day precisions in the measurement of QC samples at four tested concentrations were in the range of 2.5-9.7%, 2.5-9.9% and 5.9-11.3% for tramadol, M1 and M2, respectively. The developed procedure was applied to assess the pharmacokinetics of tramadol and its two main metabolites following administration of 100mg single oral dose of tramadol to healthy volunteers.  相似文献   

3.
In this study, the simultaneous determination of bilastine and montelukast, two recently approved co-formulated antihistaminic medications, was accomplished using a quick, sensitive, environmentally friendly, and reasonably priced synchronous fluorescence spectroscopic approach for the first time. Enhancement of the method's sensitivity down to nanogram levels was achieved by the addition of sodium dodecyl sulfate (1.0% w/v) as a micellar system. According to the results, bilastine and montelukast's fluorescence was measured at 255.3 and 355.3 nm, respectively, using Δλ of 40.0 nm and distilled water as a green diluting solvent. With respect to the concentration ranges of bilastine (5.0–300.0 ng/ml) and montelukast (50.0–1000.0 ng/ml), the method showed excellent linearity (r ≥ 0.9998). The results showed that the suggested method is highly sensitive, with detection limits of 1.42 and 13.74 ng/ml for bilastine and montelukast, respectively. Within-run precisions (intra- and interday) per cent relative standard deviations (RSD) for both analytes were <0.59%. With high percentage recoveries and low percentage RSD values, the designed approach was successfully applied for the simultaneous estimation of the cited medications in their dosage form and human plasma samples. To evaluate the green profile of the suggested method, an analytical GREENNESS metric approach (AGREE) and green analytical procedure index (GAPI) metric tools were used. These two methods for evaluating greenness confirmed that the developed method met the highest number of green requirements, recommending its use as a green substitute for the routine analysis of the studied drugs. The proposed approach was validated according to ICHQ2 (R1) guidelines.  相似文献   

4.
The optimized method for HPLC determination of tramadol and its metabolite O-desmethyl tramadol in human plasma using sotalol as internal standard has been developed and validated by a new approach. The determination by fluorescence detection was performed on re-eluted solution, obtained after liquid–liquid extraction with ethyl acetate of the three analytes from plasma. The chromatographic separation of tramadol under a gradient elution was achieved at a temperature of 15 °C with a RP-18 column, guarded by a C18 precolumn. The mobile phase was a mixed aqueous solution containing ortho-phosphoric acid, triethylamine, acetonitrile and methanol in a complex gradient mode. The quantitative determination of tramadol was performed at different successive pairs of excitation/emission wavelengths (200/300 nm, 200/295 nm, 212/305 nm) with lower limits of quantification: LLOQ = 4.078 ng/ml for tramadol, respectively LLOQ = 3.271 ng/ml for O-desmethyl tramadol. For the LLOQ limits, were calculated the values of the coefficient of variation and difference between mean and the nominal concentration. For tramadol analyte they were CV% = 5.147% and bias% = − 7.273% in the intra-days and CV% = 4.894% and bias% = 0.836% in the between-days assay, respectively for the metabolite O-desmethyl tramadol they were CV% = 11.517% and bias% = 0.337% in the intra-days and CV% = 6.41% and bias% = 3.259% in the between-days assay.

In addition, the stabilities of the analytes were verified in different conditions. Both, tramadol and its metabolite proved to be stable in plasma for four weeks, frozen at − 20 °C, but also for 48 h at 15 °C in the re-eluted solution after liquid–liquid extraction.  相似文献   


5.
In the present study, a first validated and green spectrofluorimetric approach for its assessment and evaluation in different matrices was investigated. After using an excitation wavelength of 345 nm, Roxadustat (ROX) demonstrates a highly native fluorescence at an emission of 410 nm. The influences of experimental factors such as pH, diluting solvents, and different organized media were tested, and the most appropriate solvent choice was ethanol. It was confirmed that there was a linear relationship between the concentration of ROX and the relative fluorescence intensity in the range 60.0–1000.0 ng ml−1, with the limit of detection and limit of quantitation, respectively, being 17.0 and 53.0 ng ml−1. The mean recoveries % [±standard deviation (SD), n = 5] for pharmaceutical preparations were 100.11% ± 2.24%, whereas for plasma samples, they were 100.08 ± 1.08% (±SD, n = 5). The results obtained after the application of four greenness criteria, Analytical Eco-Scale metric, NEMI, GAPI, and AGREE metric, confirmed its eco-friendliness. In addition, the whiteness meter (RGB12) confirmed its level of sustainability. The International Council for Harmonisation (ICH) criteria were used to verify the developed method through the study in both spiked plasma samples and content uniformity evaluation. An appropriate standard for various applications in industry and quality control laboratories was developed.  相似文献   

6.
A simple, rapid, and low-cost technique was developed to allow reliable analysis of the anti-hepatitis C drug sofosbuvir in bulk, tablet form, and spiked human plasma. This method depends on the ability of sofosbuvir to quench the fluorescence of the newly synthesized 2-amino-3-cyano-4,6-dimethylpyridine (reagent 3 ). Elemental analysis and spectral data were used to validate the structure of the synthesized reagent. The newly synthesized reagent exhibited a satisfactory level of fluorescence emission at 365 nm after excitation at 247 nm. All experimental variables that might affect the quenching process were analyzed and optimized. Linearity, range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) were all validated in accordance with the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. The concentration range was shown to be linear between 0.1 and 1.5 μg/mL. The technique was effectively utilized for sofosbuvir analysis in both its tablet dosage form and spiked human plasma, with mean percentage recoveries of 100.13 ± 0.35 and 94.26 ± 1.69, respectively.  相似文献   

7.
Coronavirus disease 2019 (COVID-19) is a contagious viral infection caused by coronavirus 2 (SARS-CoV-2) that causes severe acute respiratory syndrome. It has ravaged several countries and burdened many healthcare systems. As the process of authorizing a novel treatment for human use is extensive and involves multiple phases to obtain safety information and identify potential concerns. Therefore, the fastest and easiest choice was to use United States Food and Drug Administration (US FDA)-approved drugs such as favipiravir and hydroxychloroquine. For the simultaneous estimation of both medications, a simple synchronous spectrofluorimetric approach was established in which both drugs were measured at 372 and 323 nm, respectively in the presence of each other without interference at Δλ 60 nm. The effect of various experimental conditions on synchronous fluorescence intensities were thoroughly investigated and optimized. The maximum synchronous fluorescence intensities were obtained at pH 5.4 using acetate buffer (0.2 M, 0.5 ml) and ethanol as a diluent. Excellent linearity ranges were obtained using 1.0–18.0 ng/ml and 10.0–120.0 ng/ml for favipiravir and hydroxychloroquine, respectively. The approach exhibited high sensitivity with detection limits down to 0.25 ng/ml and 1.52 ng/ml and quantitation limits down to 0.77 ng/ml and 4.62 ng/ml, respectively. Spiking human plasma samples with the studied drugs yielded high % recoveries, allowing a significant bioanalytical application. Moreover, the method was validated according to International Conference on Harmonization guidelines and further applied to commercial pharmaceutical preparations with good results.  相似文献   

8.
Propofol and cisatracurium besylate have been simultaneously determined using a highly sensitive first derivative synchronous spectrofluorometric method. The method is based on measuring first derivative synchronous spectrofluorimetric amplitude at Δλ = 40 nm with a scanning rate of 600 nm/min. The different experimental parameters affecting the fluorescence intensity of the two drugs were carefully studied and optimized. The amplitude–concentration plots were rectilinear over the range 40.0–400.0 ng/mL and 20.0–280.0 ng/mL for propofol and cisatracurium, respectively with lower detection limits of 4.0 and 2.35 ng/mL and quantification limits of 12.1 and 7.1 ng/mL for propofol and cisatracurium, respectively. The proposed method was successfully applied for the determination of the two compounds in synthetic mixtures and in commercial ampoules. The high sensitivity attained using the proposed method allowed the simultaneous determination of both drugs in spiked plasma samples. The mean % recoveries in spiked human plasma (n = 3) were 96.53 ± 0.90 and 96.20 ± 1.64 for each of propofol and cisatracurium, respectively. The method was validated in compliance with International Council of Harmonization (ICH) Guidelines.  相似文献   

9.
Following the sudden widespread of the novel coronavirus (COVID-19) which first appeared in Wuhan city. Remdesivir (REM) was the first medicine licensed by the US Food and Drug Administration (FDA) for COVID-19 infected hospitalized patients. Hence, there was an urgent demand for the optimization of efficient selective and sensitive methods to be developed for the determination of REM in pharmaceuticals as well as biological samples. A sensitive and simple green spectrofluorimetric method has been developed to determine REM in pharmaceutical formulation, in addition to, spiked human plasma. The technique involves measuring the native fluorescence of REM in distilled water at 410 nm followed by excitation at 241 nm, giving a linear relationship over the range 50.00–500.00 ng/mL, and then improving the sensitivity of REM through micellar formation using 2.00% w/v sodium dodecyl sulfate (SDS). A linear relationship has been obtained over the range 10.00–350.00 ng/mL having detection and quantitation limits of 2.34 and 7.10 ng/mL, respectively. Different analytical parameters have been carefully studied. A validation study has been conducted successfully in accordance with the FDA and the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. The developed methods' greenness was assessed utilizing a greenness profile and analytical eco-scale standards. Both methods were discovered to be environmentally friendly and could be successfully used for the determination of the studied drugs in pharmaceutical formulation and human plasma with good accuracy and high precision. As a result, the developed spectrofluorimetric methods could be ideally suited for determination of REM in quality control and medicinal laboratories.  相似文献   

10.
Doxepin hydrochloride (DOX) is a tricyclic antidepressant drug. Three sensitive spectrofluorimetric methods, namely resonance Rayleigh scattering (RRS), frequency doubling scattering (FDS) and second-order scattering (SOS), were developed and validated for their estimation of doxepin in spiked human plasma and formulation using liquid–liquid extraction method through the formation of an ion pair complex with eosin Y at a pH of 4.5. Various factors affecting fluorescence intensity were optimized, and the reaction kinetics was determined using the Arrhenius equation method. Different scattering methods such as RRS, FDS and SOS were developed at maximum scattering wavelengths λex/λem = 567/567 nm for RRS, 720/360 nm for SOS and 260/520 nm for FDS, respectively. The methods exhibited high sensitivities, and the detection limits for DOX were found to be 0.82, 1.20 and 1.03 ng/ml for RRS, FDS and SOS methods, respectively. The FDS method exhibited the highest sensitivity. The methods were validated using the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use guidelines and applied to determine DOX in capsule and spiked human plasma samples.  相似文献   

11.
A simple, selective, and eco-friendly synchronous fluorescence approach was introduced for the first time for the concurrent estimation of the anticancer combination therapy of bicalutamide and resveratrol. The method relies on measuring the synchronous fluorescence spectra of bicalutamide and resveratrol at 269 and 320 nm, respectively, using Δλ of 60 nm with ethanol as a green diluting solvent. The procedure was optimized, and the method was then fully validated. Excellent linearity (R2 > 0.999) with very low detection limits (0.044 and 2.001 ng/ml) were obtained for both drugs, allowing for their analysis in human plasma. The green profile of the suggested approach was evaluated using the green solvents selecting tool (GSST), spider diagram for greenness index assessment, green analytical process index (GAPI), and Analytical GREEnness (AGREE) metric tools. These assessment metrics confirmed that the developed approach met the maximum number of green requirements, recommending its application as a green substitute for the regular analysis of the concerned drugs in human plasma. The simplicity of sample measurement enables and substantially accelerates the analysis, resulting in lower costs, enhanced procedure accuracy, and lower environmental effect.  相似文献   

12.
A simple method is described for the determination of the cyclooxygenase-2 specific inhibitor celecoxib in human serum by HPLC using the demethylated analogue as internal standard. After protein precipitation with acetonitrile, samples were extracted with chloroform. Separation was achieved on a Prontosil C18 AQ column (150x3 mm I.D., 3-microm particle size) at a flow-rate of 0.35 ml/min using water-acetonitrile (40:60, v/v) as the mobile phase. Using fluorescence detection with excitation at 240 nm and emission at 380 nm, the limit of quantification was 12.5 ng/ml for a sample size of 0.5 ml of serum. The assay was linear in the concentration range of 12.5-1500 ng/ml and showed good accuracy and reproducibility. At all concentrations intra- and inter-assay variabilities were below 11% with less than 9% error. The method was applied to the determination of celecoxib for pharmacokinetic studies in man.  相似文献   

13.
Highly sensitive, rapid, accurate and precise synchronous fluorescence spectrofluorimetric method has been developed for simultaneous analysis of a mixture of amlodipine (AMD) and metoprolol (MET). The method relies on measuring the relative synchronous fluorescence intensity of both drugs at Δλ of 90 nm in acetate buffer solution at pH 5. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.2–2 μg/ml and 0.5–10 μg/ml for AMD and MET, respectively. The limits of detection were 50 ng/ml for AMD and 130 ng/ml for MET while the limits of quantitation were 150 ng/ml for AMD and 390 ng/ml for MET. The developed method was applied successfully for the determination of the two drugs in their co‐formulated tablet. The mean percent recoveries were found to be 100.51 and 99.57 for AMD and MET, respectively.  相似文献   

14.
Orciprenaline sulphate (ORP) is a direct‐acting sympathomimetic with mainly beta‐adrenoceptor stimulant activity. It is used as a bronchodilator in the management of reversible airway obstruction. For the first time, a rapid highly sensitive spectrofluorimetric method is described that is relied on measuring the fluorescence spectra of ORP at acidic pH and without addition of any chemical reagents. The relative fluorescence intensity was measured at 310 nm and after excitation at 224 nm. ORP native fluorescence was calibrated in both water and acetonitrile as diluting solvents. The method was designed to estimate the drug in miscellaneous matrices with high accuracy and precision. Linear ranges of calibration curves were 30.0–400.0 ng/ml and 10.0–240.0 ng/ml in water and acetonitrile, respectively. The detection limits were calculated and reached as low as 3.3 and 3.1 ng/ml, respectively, representing the ultra‐sensitivity of the proposed method. This result permitted application of this method for spiked human plasma and urine and was used as a preliminary investigation with good percentage recovery (89.4–106.8%). The application was further extended to analyse ORP in its pharmaceutical formulations. The method was validated in compliance with International Council of Harmonization (ICH) Guidelines.  相似文献   

15.
A new sensitive and instantaneous spectrofluorimetric method for efficient determination of lomefloxacin (LMX) in its pure, dosage form and human plasma was designed. The developed method depends on formation of a metal-chelation compound of LMX as a ligand with zinc(II) in a buffer of acetate (pH 5.5). The following parameters; type of metal, concentration of metal, pH, type of buffer and diluting solvent were optimized. After carefully investigation; 0.2 mM zinc, 2.0 ml acetate buffer (pH 5.5) and water as diluting solvent were set as optimum reaction conditions. Under these conditions, a large increase in the intensity of the fluorescence of LMX was attained at 450 after excitation at 284 nm. The limits of detection and quantification were 5.8 and 1.9 ng ml−1, respectively, with linearity range of 10.0 to 500.0 ng ml−1. The binding mode of LMX and zinc(II) ion (Zn2+) was found to be 2:1, respectively, and confirmed by Job's plot method. Furthermore, it extended to the analysis of LMX in the spiked plasma of humans with percentage recovery (98.70 ± 0.97 to 100.30 ± 1.69%, n = 3).  相似文献   

16.
A novel, highly sensitive method was developed for simultaneous determination of tramadol and its main active metabolite O-demethyltramadol (ODMT) in rat plasma. The method involves a single-step extraction procedure and a specific determination by high-performance liquid chromatography with electrochemical detection, using an ethoxy analogue of tramadol (L-233) as internal standard. The dual-electrode detector was operated in the oxidation-screening mode. Absolute recoveries of tramadol and ODMT were about 80%. Calibration curves were linear over a concentration range of 10–1000 ng/ml for ODMT and 10–10 000 ng/ml for tramadol with intra- and inter-day coefficients of variation not exceeding 10% and 15%, respectively. The limit of quantification for tramadol and ODMT was lower than 15 ng/ml and 10 ng/ml using 100 μl of plasma, respectively. The described method allows an adequate characterization of the plasma vs. time profiles for both compounds.  相似文献   

17.
An innovative, simple, accurate, sensitive, and eco-friendly synchronous fluorescence spectrofluorimetric method has been developed for the simultaneous analysis of montelukast sodium (MON) and fexofenadine hydrochloride (FEX). The method relies on measuring the relative synchronous fluorescence intensity of both drugs using Δλ of 60 nm in methanol at 405 nm for MON and 288 nm for FEX. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.1–2.0 and 2.0–20.0 μg/ml for MON and FEX, respectively. The limits of detection were 0.018 and 0.441 μg/ml, and the limits of quantitation were 0.055 and 1.336 μg/ml for MON and FEX, respectively. The developed method was applied successfully for the determination of the two drugs in their newly released fixed-dose combination prescribed for the treatment of allergic rhinitis. The mean per cent recoveries were found to be 100.680 ± 0.890 and 100.110 ± 0.940 for MON and FEX, respectively. Furthermore, the method was found to be eco-friendly green as was evaluated according to the Green Analytical Procedure Index tool guidelines and analytical eco-scale.  相似文献   

18.
Antiepileptic drugs are among the most common medications that require therapeutic drug monitoring (TDM). Indeed, TDM provides a realistic approach to adjust drug doses for epilepsy based on plasma concentrations to optimize its clinical outcome. The most common technique for TDM is high-performance liquid chromatography, which has a very low green profile among analytical techniques. Perampanel (PER) is an inherently fluorescent compound that its fluorophore readily allows sensitive and quantitative measurements. This paper describes the development and validation of a sensitive, specific, and eco-friendly spectrofluorimetric method for the determination of PER. Experimental parameters affecting fluorescence intensity of the compound, including solvent dilution, temperature, and excitation wavelength, were studied and optimized. The developed spectrofluorimetric method was established in acetonitrile at λex = 295 nm and λem = 431 nm over a concentration range of 5–60 ng/ml. The adopted method was applied for the determination of PER in human plasma; it was effective in the range of 15–50 ng/ml. The proposed method was found to be sensitive and specific for PER and can be applied successfully in TDM of PER and in quality control laboratories.  相似文献   

19.
A stereospecific method for simultaneous quantitation of the enantiomers of tramadol (T) and its active metabolites O-demethyl tramadol (M1) and O-demethyl-N-demethyl tramadol (M5) in human plasma is reported. After the addition of penbutolol (IS), plasma (0.5 ml) samples were extracted into methyl tert-butyl ether, followed by back extraction into an acidic solution. The separation was achieved using a Chiralpak AD column with a mobile phase of hexanes:ethanol:diethylamine (94:6:0.2) and a flow rate of 1 ml/min. The fluorescence of analytes was then detected at excitation and emission wavelengths of 275 and 300 nm, respectively. All the six enantiomeric peaks of interest plus three unknown metabolite peaks and IS peak (a total of 10 peaks) eluted within 23 min, free from endogenous interference. The assay was validated in the plasma concentration range of 2.5-250 ng/ml, with a lower limit of quantitation of 2.5 ng/ml, for all the six analytes. The extraction efficiency (n=5) was close to 100% for both T and M1 enantiomers and 85% for M5 and IS enantiomers. The application of the assay was demonstrated by simultaneous measurement of plasma concentrations of T, M1, and M5 enantiomers in a healthy volunteer after the administration of 50 mg oral doses of racemic T.  相似文献   

20.
A valid, sensitive and rapid spectrofluorimetric method has been developed and validated for determination of both tadalafil (TAD) and vardenafil (VAR) either in their pure form, in their tablet dosage forms or spiked in human plasma. This method is based on measurement of the native fluorescence of both drugs in acetonitrile at λem 330 and 470 nm after excitation at 280 and 275 nm for tadalafil and vardenafil, respectively. Linear relationships were obtained over the concentration range 4–40 and 10–250 ng/mL with a minimum detection of 1 and 3 ng/mL for tadalafil and vardenafil, respectively. Various experimental parameters affecting the fluorescence intensity were carefully studied and optimized. The developed method was applied successfully for the determination of tadalafil and vardenafil in bulk drugs and tablet dosage forms. Moreover, the high sensitivity of the proposed method permitted their determination in spiked human plasma. The developed method was validated in terms of specificity, linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), precision and accuracy. The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from the comparison methods, as revealed by statistical analysis of the obtained results using Student's t‐test and the variance ratio F‐test. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号