首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was developed for the simultaneous analysis of nine chlorogenic acids (CGAs), three isomers each of caffeoylquinic acids (CQAs), feruloylquinic acids (FQAs) and dicaffeoylquinic acids (dCQAs), and their two metabolites, caffeic acid (CA) and ferulic acid (FA), in human plasma. In simultaneous multiple reaction monitoring (MRM) measurements using ESI-MS/MS with a negative ion mode, a deprotonated molecular ion derived from each of the 11 molecules was used as a precursor ion while three diagnostic product ions characteristic for each were selected for the qualitative analysis. To obtain maximal intensities for all diagnostic product ions, the collision energy was optimized for each one. LC separation was achieved under conditions of a reversed-phase Inertsil ODS-2 column combined with a gradient elution system using 50mM acetic acid with 3% acetonitrile aqueous solution and 50 mM acetic acid with 100% acetonitrile. In the quantitative analysis, one of the three diagnostic product ions for each of the 11 molecules was selected. Application of simultaneous LC-ESI-MS/MS MRM measurements to analyze the 11 standards spiked into blank human plasma indicated that all diagnostic product ions were detected without any interference, and that the sensitivity, linearity and recovery of this method were acceptable. When using this method to analyze those 11 molecules in the plasma after oral ingestion of 250 ml of a drink containing a green coffee bean extract (300 mg CGAs), all 11 molecules were identified and CQAs, FQAs and FA were quantified. CQAs, FQAs and dCQAs in human plasma were detected for the first time. This method should be useful to understand the biological and pharmacological effects of CGAs, such as improvement of human hypertension.  相似文献   

2.
A specific and sensitive liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the determination of free and total ropivacaine in human plasma. The work-up procedure involved a simple precipitation of plasma proteins with methanol. Etidocaine served as the internal standard. After microscale equilibrium-dialysis, measurement of free ropivacaine levels was performed after direct injection of the dialysate into the chromatograph. The system used a Zorbax eclipse XD8 C8 analytical column packed with 5 microm diameter particles as the stationary phase. The mobile phase consisted of a 15-min gradient (mobile phase A: 0.05% (v/v) trimethylamine in acetonitrile, mobile phase B: 2mM ammonium formate buffer (pH 3)). Mass spectrometric data were acquired in single ion monitoring mode at m/z 275 for ropivacaine and m/z 277 for etidocaine. The drug/internal standard peak area ratios (plasma) or peak areas (dialysate) were linked via a quadratic relationship to concentrations. Precision ranged from 1 to 7.6% accuracy was between 92.6 and 109%. The lower limits of quantitation were 1 microg/l in plasma and 2 microg/l in the dialysate. This method was found suitable for the analysis of plasma samples collected during a clinical trial performed in 30 infants undergoing epidural anaesthesia or continuous psoas compartment block.  相似文献   

3.
A new simple and rapid liquid chromatographic-mass spectrometric technique was designed for the determination of nine benzodiazepines in plasma and oral fluid. Benzodiazepines were extracted from alkalinised spiked and clinical plasma and oral fluid samples using a single step, liquid-liquid extraction procedure with diethyl ether. The chromatographic separation was performed with a Xterra RP18, 5 microm (150 x 2.1 mm i.d.) reversed-phase column using deuterated analogues of the analytes as internal standard. The recovery ranged from 70.3 to 86.9% for plasma and 63.9 to 77.2% for oral fluid. The limits of detection ranged from 0.5 to 1 ng/ml in plasma and 0.1 to 0.2 ng/ml for oral fluid. The method was validated for all the compounds, including linearity and the main precision parameters. The procedure, showed to be sensitive and specific, was applied to real plasma and oral fluid samples. The method is especially useful to analyse saliva samples from drivers undergoing roadside drug controls.  相似文献   

4.
A liquid chromatography-electrospray mass spectrometry method was developed for the quantitation of vinorelbine (VNB) and two metabolites, vinorelbine N-oxide (VNO) and deacetyl vinorelbine (DAV) in human serum. The limits of quantitation (LOQ) reached 0.5 ng/ml for both VNB and VNO and 1 ng/ml for DAV. The method was proved linear in the range of LOQs up to 1000 ng/ml, and extraction recovery was 80% on average for the three compounds. It was applied to the pharmacokinetic monitoring of vinorelbine and, for the first time, to the detection of VNO in the serum of patients suffering from non-small-cell lung cancer.  相似文献   

5.
A method is described for the determination of metabolites of mesocarb in human urine by combining gradient liquid chromatography and electrospray ionization (ESI)-ion trap mass spectrometry. Seven metabolites (two isomers of hydroxymesocarb, p-hydroxymesocarb, two isomers of dihydroxymesocarb and two isomers of trihydroxymesocarb) and parent drug were detected in human urine after the administration of a single oral dose 10 mg of mesocarb (Sydnocarb, two tablets of 5 mg). Various extraction techniques (free fraction, enzyme hydrolyses and acid hydrolyses) and their comparison were carried out for investigation of the metabolism of mesocarb. After extraction procedure the residue was dissolved in methanol and injected into the column HPLC (Zorbax SB-C18 (Narrow-Bore 2.1 x 150 mm i.d., 5 microm particles)) with mobile phase (0.2 ml/min) of methanol/0.2 mM ammonium acetate. Conformation of the results and identification of all metabolites are performed by LC-MS and LC-MS/MS. The major metabolites of mesocarb in urine of the human were p-hydroxylated derivative of the phenylcarbamoyl group of the parent drug (p-hydrohymesocarb) and dihydroxylated derivative of mesocarb (two isomers of dihydroxymesocarb). This analytical method for dihydrohymesocarb was very sensitive for discriminating the ingestion of mesocarb longer than the parent drug or other metabolites in human urine. The dihydroxymesocarb was detected in urine until 168-192 h after administration of the drug.  相似文献   

6.
The determination of neurotransmitters (NTs) and their metabolites facilitates better understanding of complex neurobiology in the central nervous system disorders and has expanding uses in many other fields. We present a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method for the quantification of dopamine (DA), 3,4-dihydroxyphenylacetic acid (DOPAC), homovanillic acid (HVA), norepinephrine (NE), vanillymandelic acid (VMA), 3-methoxy-4-hydroxy phenylglycol (MHPG), 5-hydroxytryptamine (5-HT), 5-hydroxyindole-3-acetic acid (5-HIAA), glutamate (Glu), and γ-aminobutyric acid (GABA). The NTs and their metabolites were dansylated and analyzed by an LC gradient on a C18 column on-line with a tandem mass spectrometer. This method exhibited excellent linearity for all of the analytes with regression coefficients higher than 0.99. The lower limit of quantification (LLOQ) values for DA, DOPAC, HVA, NE, VMA, MHPG, 5-HT, 5-HIAA, Glu, and GABA were 0.57, 0.37, 0.35, 0.40, 0.35, 0.91, 0.27, 0.43, 0.65, and 1.62 pmol/ml, respectively. The precision results were expressed as coefficients of variation (CVs), ranging from 1.5% to 13.6% for intraassay and from 2.9% to 13.7% for the interassay. This novel LC-ESI/MS/MS approach is precise, highly sensitive, specific, and sufficiently simple. It can provide an alternative method for the quantification of the NTs and their metabolites in human plasma.  相似文献   

7.
An analytical method for simultaneous determination of erythromycin propionate and its active metabolite, erythromycin base, in human plasma by high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESI-MS) was developed and validated. Roxithromycin was selected as the internal standard. The samples were directly injected after simple deproteinized procedure only. The separation was achieved on a Johnson Spherigel analytical column packed with 5 microm C18 silica, employing acetonitrile -0.1% formic acid aqueous solution (50:50) as mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 790.7 for erythromycin propionate, m/z 734.7 for erythromycin base and m/z 837.8 for roxithromycin. The correlation coefficients of the calibration curves were better than 0.997 (n=6), in the ranges from 2 ng/ml to 1 microg/ml, and from 1 to 10 microg/ml for erythromycin propionate and base. The method can provide the necessary sensitivity, precision and accuracy to allow the simultaneous determination of both compounds in a patient's plasma following a single administration of erythromycin stinoprate capsule (500 mg erythromycin base equivalent).  相似文献   

8.
Several Streptomyces and Clavibacter species produce a family of tunicamycin-like antibiotics (tunicamycins, streptovirudins, corynetoxins, etc.) that inhibit the polyprenol-P:N-acetylhexosamine-1-P translocase family, thus blocking both bacterial cell wall biosynthesis and eukaryotic protein N-glycosylation. The mechanisms of biosynthesis and resistance to these toxins by the producing bacteria are largely unknown. Electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) mass spectrometric techniques are described that structurally assign tunicamycin N-acylated variants in the picomolar range. A voltage gradient across the ESI inlet port was used to generate fragmentation ions that were structurally diagnostic for the tunicamycins. The application of in-line reversed-phase high-performance liquid chromatography-electrospray MS (LC-ESI-MS) resulted in the identification of eight new tunicamycins. Based on these structural assignments a revised nomenclature for tunicamycins is proposed. Application of the LC-ESI-MS methodology to culture supernatants and cellular extracts of the tunicamycin-producing bacterium, Streptomyces lysosuperificus, confirmed tunicamycin production and showed it to be growth-temperature dependent, but did not detect corynetoxins production in culture by phage-infected Clavibacter toxicus.  相似文献   

9.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of lansoprazole in human plasma using omeprazole as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction using diethyl-ether-dichloromethane (70:30; v/v) and chromatographed on a C(18) analytical column. The mobile phase consisted of acetonitrile-water (90:10; v/v)+10 mM formic acid. The method has a chromatographic total run time of 5 min and was linear within the range 2.5-2000 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precision, calculated from quality control (QC) samples, was less than 3.4%. The accuracy as determined from QC samples was less than 9%. The method herein described was employed in a bioequivalence study of two capsule formulations of lansoprazole.  相似文献   

10.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of Lisinopril in human plasma using Enalaprilat as internal standard. The analyte and internal standard were extracted from the plasma samples by solid-phase extraction using Waters HLB Oasis SPE cartridges and chromatographed on a C8 analytical column. The mobile phase consisted of acetonitrile/water (60:40, v/v) + 20 mM acetic acid + 4.3 mM of triethylamine. The method had a chromatographic total run-time of 6.5 min and was linear within the range 2.00-200 ng/ml. Detection was carried out on a Micromass triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM). The precision (CV%) and accuracy, calculated from limit of quantification (LOQ) samples (n = 8), were 8.9 and 98.9%, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of Lisinopril 20mg.  相似文献   

11.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

12.
An analytical method was developed for the determination of enantiomers of dencichine in plasma. Sample extraction from plasma was achieved by a solid-phase extraction (SPE) procedure using a C(18) cartridge, with carbocisteine as the internal standard. Plasma was deproteinized using inorganic acid and derivatizated before the SPE. Chiral separation of dencichine enantiomers was achieved by pre-column derivatization using o-phthaldialdehyde (OPA) and the chiral thiol N-isobutanoyl-L-cysteine (NIBC) to form diastereoisomeric isoindole derivatives that were separable by ODS column using a gradient solvent programme. The column eluent was monitored using mass spectrometry (MS). The conditions of MS detection were optimized, and selected ion monitoring was used to selectively detect D-dencichine and its arrangement isomer. High sensitivity and selectivity were obtained using this method. The limit of detection was determined to be 10 ng/ml for D-dencichine and 8 ng/ml for L-dencichine in plasma. The linearity was demonstrated over a wide range of concentrations, from 0.5 to 50 microg/ml for both enatiomers. The intra- and inter-day precision (C.V.), studied at four concentrations, was less than 7.0%. No interferences from endogenous amino acids and isomers of dencichine were found. The method was suitable for pharmacokinetic studies of dencichine enantiomers.  相似文献   

13.
A method based on high-performance liquid chromatography with UV detection in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of the antiepileptic drug oxcarbazepine and its main metabolites in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective solid-phase extraction procedure using hydrophilic-lipophilic balance cartridges. The separation was obtained on a reversed-phase column (C(18), 150x4.6 mm I.D., 5 micrometer) using a phosphate buffer-acetonitrile-methanol-triethylamine mixture (final apparent pH* 3.5) as the mobile phase. Under these chromatographic conditions, oxcarbazepine and its metabolites 10,11-dihydro-10-hydroxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine and the internal standard are baseline separated in less than 9 min. The extraction yield values were >94% for all analytes and the precision, expressed by the RSD%, was in the low percentage range. For the entire method, including sample pre-treatment and HPLC determination, the linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.995; the limit of quantitation was 15 ng ml(-1). The method was applied to plasma samples from patients undergoing chronic treatment with oxcarbazepine, both in monotherapy and in polytherapy. Based on the analytical parameters precision, accuracy, limit of quantitation and analysis time the method is suitable for routine application in therapeutic drug monitoring.  相似文献   

14.
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers.  相似文献   

15.
A quantitative assay method by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the simultaneous determination of azelnidipine and its two metabolites, M-1 (aromatized form) and M-2 (hydroxylated form), in human plasma was developed and validated. Plasma samples, each of 1.0mL, were extracted by a single step liquid-liquid extraction using a mixture of ethyl acetate and hexane (1:1, v/v), and analyzed by the LC/ESI-MS/MS method. Three analytes were separated by isocratic elution on a C(18) column, and ionized using a positive ion electrospray ionization source. The ion transitions were monitored in selected reaction monitoring (SRM) mode. The chromatographic run time was 11min per injection, with retention time of 3.6, 10.2 and 6.8min for azelnidipine, M-1 and M-2, respectively. The calibration curves for azelnidipine, M-1 and M-2 well fitted to equations by a weighted (1/X(2)) quadratic regression over the range of 0.5-40.0ng/mL (r(2)>0.9979). The intra- and inter-assay precisions (coefficient of variation: C.V.), calculated from quality control (QC) samples, were less than 8.7 and 8.4%, 3.8 and 4.7%, and 11.9 and 13.9%, respectively, for azelnidipine, M-1 and M-2. The accuracy was within +/-9% for azelnidipine, within +/-7% for M-1 and within +/-16% for M-2. The overall recoveries for azelnidipine, M-1 and M-2 were 68.8-78.6%, 54.3-62.9% and 80.4-89.7%, respectively. All analytes evaluated demonstrated acceptable short-term, long-term, auto-sampler and stock solution stabilities. Furthermore, the method developed was successfully applied to pharmacokinetic studies on azelnidipine, M-1 and M-2 after an oral dose of 16mg CALBLOCK tablets (2mgx8mg tablets) to healthy volunteers.  相似文献   

16.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

17.
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.  相似文献   

18.
A high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its three metabolites O-desmethylvenlafaxine (ODV), N-desmethylvenlafaxine (NDV) and N,O-didesmethylvenlafaxine (DDV) in human plasma has been developed and validated. Estazolam was used as the internal standard. The compounds and internal standard were extracted from plasma by a liquid-liquid extraction. The HPLC separation of the analytes was performed on a Thermo BDS HYPERSIL C18 (250 mm x 4.6 mm, 5 microm, USA) column, using a gradient elution program with solvents constituted of water (ammonium acetate: 30 mmol/l, formic acid 2.6 mmol/l and trifluoroacetic acid 0.13 mmol/l) and acetonitrile (60:40, V/V) at a flow-rate of 1.0 ml/min. All of the analytes were eluted within 6 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer and were detected in the selected ion recording (SIR) mode. Calibration curves in spiked whole blood were linear from 4.0-700 ng/ml, 2.0-900 ng/ml, 3.0-800 ng/ml and 2.0-700 ng/ml for VEN, ODV, NDV and DDV, respectively, all of them with coefficients of determination above 0.9991. The average extraction recoveries for all the four analytes were above 77%. The methodology recoveries were higher than 91%. The limits of detection were 0.4, 0.2, 0.3, and 0.2 ng/ml for VEN, ODV, NDV and DDV, respectively. The intra- and inter-day variation coefficients were less than 11%. The method is accurate, sensitive and reliable for the pharmacokinetic study of venlafaxine as well as therapeutic drug monitoring (TDM).  相似文献   

19.
Liquid chromatography-electrospray ionization mass spectrometry methods are described for the simultaneous quantification of a bis-thiazolium compound (T3), its related prodrug (TE3) and an intermediate compound (mTE3) that appeared during the prodrug/drug conversion process, in human plasma, whole blood and red blood cells (RBCs). The methods involve solid phase extraction (SPE) of the compounds and the internal standard (verapamil) from the three different matrices using OasisHLB columns with an elution solvent of 2x1 ml of acetonitrile containing 1 ml/l trifluoroacetic acid (TFA). HPLC separation was performed on a C18 encapped Xterra column packed with 3.5 microm particles. The mobile phase used a 8 min gradient, from water containing 1 ml/l TFA to acetonitrile containing 1 ml/l TFA, at a flow rate of 400 microl/min. Verapamil and the TE3 compound were characterized by the protonated molecules at m/z 455 and m/z 541, respectively. The mTE3 species was detected through the (M)+ ion at m/z 497. The T3 compound was detected by use of two ions, the quaternary ammonium salt (M2+/2) at m/z 227.3 and by the adduct with TFA (M+TFA)+ at m/z 567.3. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (or whole blood) concentrations in the tested range of 6.4-1282 microg/l (12.8-2564 microg/kg) for T3, 20-2000 microg/l (40-4000 microg/kg) for mTE3 and 10-2000 microg/l (40-4000 microg/kg) for TE3, and to T3 concentrations in RBCs ranging from 12.8 to 2564 microg/kg. Inter-assay precision (in terms of R.S.D.) was below 13.5% and accuracy ranged from 95.4 to 107%. The dilution of the samples (plasma or whole blood) has no influence on the performance of the methods. The extraction recoveries averaged 87% for T3, 53% for mTE3 and 79% for TE3 in plasma; 79% for T3, 57% for mTE3 and 65% for TE3 in blood; and 93% for T3 in RBCs, and was constant across the calibration range. The lower limits of quantitation were 6.4 microg/l for T3, 20 microg/l for mTE3 and 10 microg/l for TE3 in plasma; 12.8 microg/kg for T3 and 40 microg/kg for mTE3 and TE3 in blood; and 12.8 microg/kg for T3 in RBCs. Stability tests under various conditions were also investigated. The three-step SPE procedure (loading, clean-up, and elution) described in this paper to quantify these new anti-malarial compounds in plasma, whole blood and RBCs, can easily be automated by using either robotisation or an automated sample preparation system.  相似文献   

20.
A new method for the determination of tranexamic acid (TA) in human plasma using high performance liquid chromatography with tandem mass spectrometric detection was described. TA and the internal standard, methyldopa, was extracted from a 200 l plasma sample by a one-step deproteination using perchloric acid. Chromatographic separation was performed on an Xtrra MS C18 Column (2.1 mm x 100 mm, 3.5 microm) with the mobile phase consisting of 10% acetonitrile in 2 mM ammonium acetate buffer (pH 3.5) at a flow rate of 0.15 ml/min. The total run time was 5 min for each sample. Detection and quantitation was performed by the mass spectrometer using the multiple reaction monitoring of the precursor-product ion pair m/z 158 --> 95 for TA and m/z 212 --> 166 for methyldopa, respectively. The method was linear over the concentration range of 0.02-10.00 g/ml with lower limit of quantification of 0.02 microg/ml for TA. The intra- and inter-day precision was less than 11% and accuracy ranged -10.88 to 11.35% at the TA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of TA in 12 healthy subjects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号