首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated in common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The calculated mass sensitivity according to the mechanical properties of the cantilever sensor is approximately 50 pg/Hz; this mass corresponds to an approximate sensitivity of approximately 100 Escherichia coli cells. The sensor is able to detect active growth of E. coli cells within 1 h. The starting number of E. coli cells initially attached to the sensor cantilever was, on average, approximately 1,000 cells. Furthermore, this method allows the detection of selective growth of E. coli within only 2 h by adding antibiotics to the nutritive layers. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of selective bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing.  相似文献   

2.
A rapid biosensor for the detection of bacterial growth was developed using micromechanical oscillators coated in common nutritive layers. The change in resonance frequency as a function of the increasing mass on a cantilever array forms the basis of the detection scheme. The calculated mass sensitivity according to the mechanical properties of the cantilever sensor is ~50 pg/Hz; this mass corresponds to an approximate sensitivity of ~100 Escherichia coli cells. The sensor is able to detect active growth of E. coli cells within 1 h. The starting number of E. coli cells initially attached to the sensor cantilever was, on average, ~1,000 cells. Furthermore, this method allows the detection of selective growth of E. coli within only 2 h by adding antibiotics to the nutritive layers. The growth of E. coli was confirmed by scanning electron microscopy. This new sensing method for the detection of selective bacterial growth allows future applications in, e.g., rapid antibiotic susceptibility testing.  相似文献   

3.
Detection of Escherichia coli in blood using flow cytometry   总被引:3,自引:0,他引:3  
A rapid method for the detection of Escherichia coli in blood has been developed. The method employs blood cell lysis, staining of bacteria with ethidium bromide, and detection of stained bacteria using flow cytometry. The detection protocol requires less than 2 h sample handling time and is not dependent on bacterial growth. This method has been applied to human donor blood specimens seeded with various E. coli concentrations and to two rabbit model systems. Bacterial detection is evident from the in vitro human blood studies at levels of 10 E. coli/ml and from in vivo rabbit model studies at less than 100 E. coli/ml.  相似文献   

4.
Contaminated vegetables have been identified as one of the principal sources of foodborne illnesses. Escherichia coli is one of the bacteria that can contaminate vegetables and cause serious foodborne disease. The development of simple and rapid assays for detection of E. coli would enable official agencies and food industries to identify contaminated foodstuffs in a timelier manner. In this work, we detected E. coli contamination in four types of vegetables using a 24 h procedure. This method is very specific, rapid and simple to use in the laboratory. Indeed, the enrichment, DNA isolation and polymerase chain reaction (PCR) amplification procedures described here can also be used for detection of E. coli in other foods.

PRACTICAL APPLICATIONS


Foodborne disease remains an important public health threat worldwide; one of the most important food safety hazards is associated with raw vegetables. Several studies have found that products can support the growth of enteric bacterial pathogens such as Salmonella , Shigella and Escherichia coli . Culture techniques are universally recognized as the standard method for detecting pathogenic bacteria in foods. Bacteria are detected and subsequently identified by growth on solid selective culture media and by analysis of metabolic properties or serotyping. This process is lengthy and may last 5–10 days or more. In our investigation, the polymerase chain reaction (PCR) detection of E. coli in vegetables was realized within 24 h. The pre-enrichment step used in this study did not have any inhibiting effect on the PCR. Therefore, it became possible to rapidly and directly detect E. coli in raw vegetables by the PCR technique just by heating samples.  相似文献   

5.
AIM: Calibration of impedance measurement was performed vs the Association Fran?oise de Normalisation (AFNOR) MPN method with a view to rapid enumeration of Escherichia coli in live marine bivalve molluscs. METHODS AND RESULTS: Linear regression models between log10 MPN and detection time (DT) were adjusted for several shellfish types, growth media, and impedance instruments (BacTrac and Malthus systems). Escherichia coli concentrations could be estimated from DT using a single regression line for BacTrac 4100 with M1 medium (R2 = 87.8%) and Malthus with M2 medium (R2 = 86.7%), and two regression lines for BacTrac 4110 with M2 medium (R2 = 86.4 and 88.2%). The uncertainty of the predicted bacterial concentration was around +/-0.43 log unit for duplicate sample analysis. The impedance signal was attributable to E. coli in 99% of cases. All cultures containing E. coli produced an impedance signal with BacTrac 4100 and BacTrac 4110, whereas 5.6% did not exhibit a signal with Malthus. CONCLUSIONS: Impedance measurement is a possible alternative to the MPN method for rapid quantitative estimation of E. coli in live bivalve shellfish. SIGNIFICANCE AND IMPACT OF THE STUDY: The impedance method reduces analysis handling time considerably and is much easier to use than the MPN method. Moreover, results can be obtained within 5-10 h, allowing rapid intervention to ensure public health protection in case of shellfish contamination.  相似文献   

6.
A rapid microtiter methionine assay was developed using a methionine auxotroph E. coli strain. The bacterial strain was first grown on rich media to promote extensive bacterial growth and the cells were depleted to exhaust all endogenous methionine. After depletion, cells were transferred to minimal media with increasing concentrations of methionine and microtiter plates were incubated at 37C for 6 h. Methionine microtiter standard curves yielded linear growth responses to increasing concentrations of methionine in the range of 0 to 26.8 μM. Addition of different antibiotic and antifungal agents to the media did not significantly alter the linear growth response observed in the microtiter assay. This microtiter plate E. coli methionine assay has potential as a rapid in vitro assay method for quantifying methionine.  相似文献   

7.
Escherichia coli, Salmonella spp. and Staphylococcus aureus are frequent co-visitors of contaminated foods to cause food-borne diseases. To achieve rapid detection of three organisms by multiplex PCR, a selective co-enrichment broth was considered to design using response surface methodology (RSM) in this work. NaCl, LiCl and KSCN as selective bacterial inhibitors were selected to optimize their concentrations for a matched composition of bacterial biomass with uniform amplification of three targets. Central composite design was employed to collect the data and fit the responses. Three quadratic polynomial models were derived by computer simulation. A statistical analysis was carried out to explore the effects of the variables on the composition of bacterial biomass and PCR amplification yields. In the end, a novel broth (ESS-3 broth) of NaCl 1.60%, LiCl 0.70%, KSCN 0.10% was formulated to allow co-enrichment of the target pathogens and suppress growth of some non-target pathogens. The simultaneous detection of E. coli, Salmonella spp. and S. aureus was developed on a rapid, convenient and sensitive method consisting of selective co-enrichment in ESS-3 broth, DNA extraction with the boiling method and robust test by multiplex PCR. Our work provided broader application of RSM for the simultaneous detection of other combinations of multiple pathogens.  相似文献   

8.
Multiplex PCR assay (m-PCR) with three sets of primers was developed for simultaneous identification of Campylobacter jejuni and C. coli. Poultry faecal samples were enriched in Preston broth for 24 h and streaking on selective media was performed before and after enrichment. m-PCR was applied on bacterial cultures harvested from media plates. The data showed a selective effect of Preston broth which favoured the growth of C. coli. Identification of the species by the hippurate hydrolysis test and by the m-PCR was performed on 294 isolates of Campylobacter. The efficiency of the identification by the biochemical test is only 34% in comparison to 100% efficiency with the PCR. The use of our m-PCR in combination with the culture method allowed reliable detection and identification of C. jejuni and C. coli within 3-4 d.  相似文献   

9.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

10.
AIMS: The effect of phage concentration on the activity of adenylate kinase (AK) released from the cells lysed during infection was investigated in order to optimize a bioluminescent phage-mediated method for bacterial enumeration. METHODS AND RESULTS: The number of bacteria lysed by phages specific to Salmonella enteritidis and E. coli was determined using a bioluminescent method for the detection of AK released. In order to optimize the assay, the effect of phage concentration and time of infection on the amount of AK released was investigated. The release of AK was greatest at a multiplicity of infection (moi) of 10-100. CONCLUSION: The amount of AK released from Salmonella enteritidis and E. coli G2-2 cells by specific phages, SJ2 and AT20, respectively, depended on the type of bacteria, the stage of growth, the nature of phage, moi and time. SIGNIFICANCE AND IMPACT OF THE STUDY: An assay is described which allows detection of E. coli and Salmonella Enteritidis within 2 h at levels of 103 cfu ml-1.  相似文献   

11.
利用多重PCR技术建立快速检测化妆品中三种致病菌的方法。根据已报道的大肠杆菌phoA基因、铜绿假单胞菌外膜蛋白基因oprL和金黄色葡萄球菌特异性序列SmaI选择特异性引物,对人工染菌化妆品进行多重PCR检测。结果显示,三种致病菌的基因组DNA均可与各自引物特异性结合,扩增产物大小分别为622 bp、504 bp和426 bp。该方法用于人工污染的化妆品中,大肠杆菌的检出限浓度为103 CFU/mL,铜绿假单胞菌和金黄色葡萄球菌的检出限浓度为105 CFU/mL。作者建立的多重PCR方法可同时快速、特异地对化妆品中三种致病菌进行检测,在化妆品行业具有较大的应用价值。  相似文献   

12.
R. ARMON AND Y. KOTT. 1993. A rapid, simple and sensitive direct bacteriophage presence detection method for 500 ml drinking water samples has been developed. The method includes a glass device consisting of a jar containing the water sample and an immersible probe filled with solidified soft agar containing bacterial host cells. Host bacteria in logarithmic phase were added to the experimental volume and the probe was submerged. The entire device was incubated in a water bath at 36C.
Plaques of somatic bacteriophage infecting Escherichia coli strain CN13, could be detected within 3 h. Male-specific bacteriophages infecting E. coli F+ amp were detected within 6 h. Bacteriophage infecting the anaerobe Bacteroides fragilis subsp. fragilis HSP40 were detected after 8 h. Application of this device and the associated technique, enabled a one-step detection of 1 pfu of E. coli or Bact. fragilis specific bacteriophage in 500 ml drinking water samples.  相似文献   

13.
【目的】探索一种无创、快速、可靠、经济地鉴定绿脓杆菌的新方法。【方法】利用光声光谱技术分别对大肠杆菌、绿脓杆菌在35°C下培养24 h后产生的挥发性代谢产物(Bacterial volatile compounds,BVCs)进行连续检测,获得各细菌挥发性气体的光声光谱图谱,并用“逆向思维”的方法对其检测结果进行分析。【结果】利用光声光谱技术对绿脓杆菌、大肠杆菌的挥发性代谢产物进行检测分析,发现绿脓杆菌产生了较高浓度的氰化氢(HCN),而大肠杆菌并未检测出HCN,据此可以对绿脓杆菌进行初步鉴定。【结论】光声光谱技术为绿脓杆菌的鉴定提供了一种简单、快速、经济的方法。为加速其在临床中的应用,提出了“三步走”方案:建立“大数据”、完善“比对算法”、创建“自动检测-比对-校对-鉴定”系统。  相似文献   

14.
Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.  相似文献   

15.
AIMS: Enzyme substrates based on 4-methylumbelliferone are widely used for the detection of Escherichia coli and enterococci in water, by detection of beta-glucuronidase and beta-glucosidase activity respectively. This study aimed to synthesize and evaluate novel umbelliferone-based substrates with improved sensitivity for these two enzymes. METHODS AND RESULTS: A novel beta-glucuronide derivative based on 6-chloro-4-methylumbelliferone (CMUG) was synthesized and compared with 4-methylumbelliferyl-beta-D-glucuronide (MUG) using 42 strains of E. coli in a modified membrane lauryl sulfate broth. Over 7 h of incubation, the fluorescence generated from the hydrolysis of CMUG by E. coli was over twice that from MUG, and all of the 38 glucuronidase-positive strains generated a higher fluorescence with CMUG compared with MUG. Neither substrate caused inhibition of bacterial growth in any of the tested strains. Four beta-glucosidase substrates were also synthesized and evaluated in comparison with 4-methylumbelliferyl-beta-D-glucoside (MU-GLU) using 42 strains of enterococci in glucose azide broth. The four substrates comprised beta-glucoside derivatives of umbelliferone-3-carboxylic acid and its methyl, ethyl and benzyl esters. Glucosides of the methyl, ethyl and benzyl esters of umbelliferone-3-carboxylic acid, were found to be superior to MU-GLU for the detection of enterococci, especially after 18 h of incubation, while umbelliferone-3-carboxylic acid-beta-D-glucoside was inferior. However, the variability in detectable beta-glucosidase activity among the different strains of enterococci in short-term assays using the three carboxylate esters (7 h incubation) may compromise their use for rapid detection and enumeration of these faecal indicator bacteria. CONCLUSIONS: The beta-glucuronidase substrate CMUG appears to be a more promising detection system than the various beta-glucosidase substrates tested. SIGNIFICANCE AND IMPACT OF THE STUDY: The novel substrate CMUG showed enhanced sensitivity for the detection of beta-glucuronidase-producing bacteria such as E. coli, with a clear potential for application in rapid assays for the detection of this indicator organism in natural water and other environmental samples.  相似文献   

16.
Staining bacteria with esterified fluorogenic substrates followed by flow cytometric analysis offers a means for rapid detection of metabolically active bacteria. Flow cytometry (FCM) was used to assess carboxyfluorescein diacetate (CFDA) and carboxyfluorescein diacetate succinimidyl ester (CFDA/SE) as indicators of bacterial activity for cultured bacteria, including Aeromonas hydrophila, Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus epidermidis and bacteria from environmental waters. In theory, CFDA/SE should be a better indicator of metabolic bacterial activity compared to CFDA due to greater intracellular retention of the fluorescent product. Qualitative and quantitative analysis of exponential phase cultures, mixtures of active and inactive cells and bacteria from environmental waters revealed CFDA was successful in detecting active bacteria, whereas CFDA/SE was not. CFDA/SE labelled inactive cells with intensities equal to that of the active population and could not even discriminate between bacteria in exponential phase growth and a fixed cell preparation. We propose that the specific mode of action of the succinimidyl ester (SE) group in combination with the nonenzymatic aqueous hydrolysis of the CFDA moiety results in the nonspecific labelling of all cells, irrespective of their metabolic state. This study shows that CFDA/SE is a poor marker of bacterial activity.  相似文献   

17.
The goal of this study was develop a rapid high-throughput method for the assessment of the bacterial adhesion to tissue culture cells and test this method by investigation of the adhesion and growth of pathogenic and non-pathogenic Escherichia coli strains in the presence of HeLa human epithelial cells. Fifteen strains of E. coli were transformed with a plasmid carrying the entire lux operon of Photorhabdus luminescens to make them bioluminescent. By using the Time-to-Detection approach and bioluminescence imaging in microplate format, the adherence and growth of bacteria in tissue culture medium in the presence of HeLa cells was monitored. It was observed that Eagle's minimal essential medium (EMEM) supplemented with 10% fetal bovine serum (FBS) significantly inhibited growth of E. coli. However, in the presence of HeLa cells the detected growth of E. coli was similar to the growth observed in LB medium. It was established that the initial number of E. coli cells present in the microplate directly correlated with the time necessary for the bioluminescence signal to reach the threshold level, hence allowing the accurate assessment of the adhered cells within 8-10 h. Neither bacterial adherence nor growth kinetics correlated with the pathogenicity of the strain though they were strain-specific. The developed approach provided new information on the interaction of E. coli with epithelial cells and could be used for both pathogenicity research and for the screening of potential therapeutic agents for the ability to minimize pathogen colonization of human tissues.  相似文献   

18.
A new chemiluminescent in situ hybridization (CISH) method provides simultaneous detection, identification, and enumeration of culturable Escherichia coli cells in 100 ml of municipal water within one working day. Following filtration and 5 h of growth on tryptic soy agar at 35 degrees C, individual microcolonies of E. coli were detected directly on a 47-mm-diameter membrane filter using soybean peroxidase-labeled peptide nucleic acid (PNA) probes targeting a species-specific sequence in E. coli 16S rRNA. Within each microcolony, hybridized, peroxidase-labeled PNA probe and chemiluminescent substrate generated light which was subsequently captured on film. Thus, each spot of light represented one microcolony of E. coli. Following probe selection based on 16S ribosomal DNA (rDNA) sequence alignments and sample matrix interference, the sensitivity and specificity of the probe Eco16S07C were determined by dot hybridization to RNA of eight bacterial species. Only the rRNA of E. coli and Pseudomonas aeruginosa were detected by Eco16S07C with the latter mismatch hybridization being eliminated by a PNA blocker probe targeting P. aeruginosa 16S rRNA. The sensitivity and specificity for the detection of E. coli by PNA CISH were then determined using 8 E. coli strains and 17 other bacterial species, including closely related species. No bacterial strains other than E. coli and Shigella spp. were detected, which is in accordance with 16S rDNA sequence information. Furthermore, the enumeration of microcolonies of E. coli represented by spots of light correlated 92 to 95% with visible colonies following overnight incubation. PNA CISH employs traditional membrane filtration and culturing techniques while providing the added sensitivity and specificity of PNA probes in order to yield faster and more definitive results.  相似文献   

19.
In this paper, we describe a novel method for detecting Escherichia coli (E. coli) O157:H7 by using a quartz crystal microbalance (QCM) immunosensor based on beacon immunomagnetic nanoparticles (BIMPs), streptavidin-gold, and growth solution. E. coli O157-BIMPs were magnetic nanoparticles loaded with polyclonal anti-E. coli O157:H7 antibody (target antibody, T-Ab) and biotin-IgG (beacon antibody, B-Ab) at an optimized ratio of 1:60 (T-Ab:B-Ab). E. coli O157:H7 was captured and separated by E. coli O157-BIMPs in a sample, and the streptavidin-gold was subsequently conjugated to E. coli O157-BIMPs by using a biotin-avidin system. Finally, the gold particles on E. coli O157-BIMPs were enlarged in growth solution, and the compounds containing E. coli O157:H7, E. coli O157-BIMPs, and enlarged gold particles were collected using a magnetic plate. The QCM immunosensor was fabricated with protein A from Staphylococcus aureus and monoclonal anti-E. coli O157:H7 antibody. The compounds decreased the immunosensor's resonant frequency. E. coli O157-BIMPs and enlarged gold particles were used as "mass enhancers" to amplify the frequency change. The frequency shift was correlated to the bacterial concentration. The detection limit was 23 CFU/ml in phosphate-buffered saline and 53 CFU/ml in milk. This method could successfully detect E. coli O157:H7 with high specificity and stability. The entire procedure for the detection of E. coli O157:H7 took only 4 h.  相似文献   

20.
AIMS: A new rapid method was developed to rapidly monitor Escherichia coli counts in foods. MATERIALS AND RESULTS: One ml of modified selective broth with 4-methylumbelliferyl beta-D-glucuronide and 1 ml of food sample were mixed in a sterile test tube and incubated at 37 degrees C. The positive reaction (fluorescence under u.v. light) was monitored at regular 30 min intervals. The positive reaction times in test tubes were compared with actual E. coli numbers from tested samples. The growth of E. coli in test tubes (broth) was much faster than growth on agar. The first experiment was performed to evaluate the rapid correlation method using pure E. coli cultures. The correlation between E. coli counts by the conventional plating method and positive reaction (fluorescence production) times in test tubes was highly agreeable (r(2) = 0 x 95). In the case of low E. coli numbers, such as 2 x 0 log10 cfu ml(-1), the rapid correlation method detected their presence after 10 h incubation. When highly contaminated samples were assayed (8 log10 cfu ml(-1)), the rapid correlation method detected the presence of E. coli after 4 h incubation. In the ground beef experiment, the correlation between fluorescence production time and actual E. coli numbers was also strongly agreeable (r(2) = 0 x 92). CONCLUSIONS: From these results, it is obvious that the new rapid method can rapidly monitor E. coli counts in foods. SIGNIFICANCE AND IMPACT OF THE STUDY: The results indicated that the new method saved about 10-14 h incubation time compared to conventional plating methods. The rapid correlation method required much shorter incubation times compared to conventional plating methods for monitoring E. coli.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号