首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
Next to the identification of proteins and the determination of their expression levels, the analysis of post-translational modifications (PTM) is becoming an increasingly important aspect in proteomics. Here, we review mass spectrometric (MS) techniques for the study of protein glycosylation at the glycopeptide level. Enrichment and separation techniques for glycoproteins and glycopeptides from complex (glyco-)protein mixtures and digests are summarized. Various tandem MS (MS/MS) techniques for the analysis of glycopeptides are described and compared with respect to the information they provide on peptide sequence, glycan attachment site and glycan structure. Approaches using electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) of glycopeptides are presented and the following fragmentation techniques in glycopeptide analysis are compared: collision-induced fragmentation on different types of instruments, metastable fragmentation after MALDI ionization, infrared multi-photon dissociation, electron-capture dissociation and electron-transfer dissociation. This review discusses the potential and limitations of tandem mass spectrometry of glycopeptides as a tool in structural glycoproteomics.  相似文献   

2.
Although peptide mass fingerprinting is currently the method of choice to identify proteins, the number of proteins available in databases is increasing constantly, and hence, the advantage of having sequence data on a selected peptide, in order to increase the effectiveness of database searching, is more crucial. Until recently, the ability to identify proteins based on the peptide sequence was essentially limited to the use of electrospray ionization tandem mass spectrometry (MS) methods. The recent development of new instruments with matrix-assisted laser desorption/ionization (MALDI) sources and true tandem mass spectrometry (MS/MS) capabilities creates the capacity to obtain high quality tandem mass spectra of peptides. In this work, using the new high resolution tandem time of flight MALDI-(TOF/TOF) mass spectrometer from Applied Biosystems, examples of successful identification and characterization of bovine heart proteins (SWISS-PROT entries: P02192, Q9XSC6, P13620) separated by two-dimensional electrophoresis and blotted onto polyvinylidene difluoride membrane are described. Tryptic protein digests were analyzed by MALDI-TOF to identify peptide masses afterward used for MS/MS. Subsequent high energy MALDI-TOF/TOF collision-induced dissociation spectra were recorded on selected ions. All data, both MS and MS/MS, were recorded on the same instrument. Tandem mass spectra were submitted to database searching using MS-Tag or were manually de novo sequenced. An interesting modification of a tryptophan residue, a "double oxidation", came to light during these analyses.  相似文献   

3.
A novel ProteinChip-interfaced tandem mass spectrometer was employed to identify collagen binding proteins from biosurfactant produced by Lactobacillus fermentum RC-14. On-chip tryptic digestion of the captured collagen binding proteins resulted in rapid sequence identification of five novel tryptic peptide sequences via collision-induced dissociation tandem mass spectrometry.  相似文献   

4.
A novel ProteinChip-interfaced tandem mass spectrometer was employed to identify collagen binding proteins from biosurfactant produced by Lactobacillus fermentum RC-14. On-chip tryptic digestion of the captured collagen binding proteins resulted in rapid sequence identification of five novel tryptic peptide sequences via collision-induced dissociation tandem mass spectrometry.  相似文献   

5.
Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation (~8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup was demonstrated by the analysis of <15 microg depleted human serum proteome by a combination of SDS-PAGE and SPE-LC-MS/MS. A total of 88 unique gene products spanning 3 orders of magnitude in serum protein concentration were identified using stringent database search criteria.  相似文献   

6.
Electrospray ionization mass spectrometry, a leading method for the quantification of biomolecules, is useful for the analysis of posttranslational modifications of proteins. Here we describe a mass spectrometric approach for determining levels of acetylation at individual lysine residues within the amino-terminal tail of histone H4. Because of the high density of acetylatable lysine residues within this short span of amino acids, collision-induced dissociation tandem mass spectrometry was required. In addition, it was necessary to develop an algorithm to determine the fraction of acetylation at specific lysine residues from fragment ions containing more than one lysine residue. This is the first report of direct measurement of endogeneous levels of acetylation at individual lysine residues within the amino-terminal tail of yeast histone H4 and is the first use of tandem mass spectrometry for quantification of peptides containing multiple sites of modification.  相似文献   

7.
With the recent quick expansion of DNA and protein sequence databases, intensive efforts are underway to interpret the linear genetic information of DNA in terms of function, structure, and control of biological processes. The systematic identification and quantification of expressed proteins has proven particularly powerful in this regard. Large-scale protein identification is usually achieved by automated liquid chromatography-tandem mass spectrometry of complex peptide mixtures and sequence database searching of the resulting spectra [Aebersold and Goodlett, Chem. Rev. 2001, 101, 269-295]. As generating large numbers of sequence-specific mass spectra (collision-induced dissociation/CID) spectra has become a routine operation, research has shifted from the generation of sequence database search results to their validation. Here we describe in detail a novel probabilistic model and score function that ranks the quality of the match between tandem mass spectral data and a peptide sequence in a database. We document the performance of the algorithm on a reference data set and in comparison with another sequence database search tool. The software is publicly available for use and evaluation at http://www.systemsbiology.org/research/software/proteomics/ProbID.  相似文献   

8.
We describe an integrated workstation for the automated, high-throughput, and conclusive identification of proteins by reverse-phase chromatography electrospray ionization tandem mass spectrometry. The instrumentation consists of a refrigerated autosampler, a submicrobore reverse-phase liquid chromatograph, and an electrospray triple quadrupole mass spectrometer. For protein identification, enzymatic digests of either homogeneous polypeptides or simple protein mixtures were generated and loaded into the autosampler. Samples were sequentially injected every 32 min. Ions of eluting peptides were automatically selected by the mass spectrometer and subjected to collision-induced dissociation. Following each run, the resulting tandem mass spectra were automatically analyzed by SEQUEST, a program that correlates uninterpreted peptide fragmentation patterns with amino acid sequences contained in databases. Protein identification was established by SEQUEST_SUMMARY a program that combines the SEQUEST scores of peptides originating from the same protein and ranks the cumulative results in a short summary. The workstation's performance was demonstrated by the unattended identification of 90 proteins from the yeast Saccharomyces cerevisiae, which were separated by high-resolution two-dimensional PAGE. The system was found to be very robust and identification was reliably and conclusively established for proteins if quantities exceeding 1-5 pmol were applied to the gel. The level of automation, the throughput, and the reliability of the results suggest that this system will be useful for the many projects that require the characterization of large numbers of proteins.  相似文献   

9.
Although only a few years old, the combination of a linear ion trap with an Orbitrap analyzer has become one of the standard mass spectrometers to characterize proteins and proteomes. Here we describe a novel version of this instrument family, the Orbitrap Elite, which is improved in three main areas. The ion transfer optics has an ion path that blocks the line of sight to achieve more robust operation. The tandem MS acquisition speed of the dual cell linear ion trap now exceeds 12 Hz. Most importantly, the resolving power of the Orbitrap analyzer has been increased twofold for the same transient length by employing a compact, high-field Orbitrap analyzer that almost doubles the observed frequencies. An enhanced Fourier Transform algorithm-incorporating phase information-further doubles the resolving power to 240,000 at m/z 400 for a 768 ms transient. For top-down experiments, we combine a survey scan with a selected ion monitoring scan of the charge state of the protein to be fragmented and with several HCD microscans. Despite the 120,000 resolving power for SIM and HCD scans, the total cycle time is within several seconds and therefore suitable for liquid chromatography tandem MS. For bottom-up proteomics, we combined survey scans at 240,000 resolving power with data-dependent collision-induced dissociation of the 20 most abundant precursors in a total cycle time of 2.5 s-increasing protein identifications in complex mixtures by about 30%. The speed of the Orbitrap Elite furthermore allows scan modes in which complementary dissociation mechanisms are routinely obtained of all fragmented peptides.  相似文献   

10.
At present, mass spectrometry provides a rapid and sensitive means for making conclusive protein identifications from complex mixtures. Sequencing tryptic peptides derived from proteolyzed protein samples, also known as the "Bottom Up" approach, is the mass spectrometric gold standard for identifying unknowns. An alternative technology, "Top Down" characterization, is emerging as a viable option for protein identifications, which involves analyzing the intact unknowns for accurate mass and amino acid sequence tags. In this paper, both characterization methods were employed to more comprehensively differentiate two early-eluting peaks in a process-scale size-exclusion chromatography (SEC) step for a recombinant, immunoglobulin gamma-1 (IgG-1) fusion protein. The contents of each SEC peak were enzymatically digested, and the resulting peptides were mapped using reversed-phase (RP) HPLC-ion trap MS. Many low-level UV signals were observed among the fusion protein-related peptide peaks. These unknowns were collected, concentrated, and analyzed using nanoelectrospray (nanoES) collision-induced dissociation (CID) tandem (MS/MS) mass spectrometry for identification. The peptide sequencing experiments resulted in the identification of twenty host cell-related proteins. Following peptide mapping, the contents of the two SEC peaks were protein mass profiled using on-line RP HPLC coupled to a high-resolution, quadrupole time-of-flight (Qq/TOF) MS. Unknown proteins were also collected, concentrated, and dissociated using nanoES CID MS/MS. Intact protein CID experiments and accurate molecular weight information allowed for the identification of three full length host cell-derived proteins and numerous clips from these and additional proteins. The accurate molecular weight values allowed for the assignment of N- and C-terminal processing, which is difficult to conclusively access from peptide mapping data. The peptide-mapping experiments proved to be far more effective for making protein identifications from complex mixtures, whereas the protein mass profiling was useful for assessing modifications and distinguishing protein clips from full length species.  相似文献   

11.
Juárez P  Sanz L  Calvete JJ 《Proteomics》2004,4(2):327-338
The protein composition of the crude venom of Sistrurus barbouri was analyzed by two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis. Proteins were separated by reversed phase high-performance liquid chromatography and characterized by N-terminal sequence analysis. The molecular mass and number of cysteine residues of the purified proteins were determined by matrix-associated laser desorption/ionization-time of flight mass spectrometry. Selected protein bands were subjected to in-gel tryptic digestion and peptide mass fingerprinting. Analysis of the tandem mass spectrometry spectra of selected doubly-charged peptide ions was done by collision-induced dissociation in a quadrupole-linear ion trap instrument. Our results show that the venom proteome of the pigmy rattlesnake S. barbouri is composed of proteins belonging to a few protein families, which can be structurally characterized by their disulfide bond contents.  相似文献   

12.
We have applied proteomic analysis to the degeneration of photoreceptors. In the rd1 mouse, a recessive mutation in the PDE6B gene leads to rapid loss of rods through apoptosis. By 5 wk postnatal, virtually all rod photoreceptors have degenerated, leaving one row of cones that degenerates secondarily. In order to assess comparative protein expression, proteins extracted from whole retina were resolved on a two-dimensional gel and identified by mass spectrometry combined with database screening. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry coupled to peptide mass fingerprinting was sufficient to identify most of the proteins, the remaining being identified with additional sequence information obtained by nano-electrospray ionization tandem mass spectrometry or liquid chromatography tandem mass spectrometry. The study revealed 212 spots, grouped into 109 different proteins. Differential analysis showed loss of proteins involved in the rod-specific phototransduction cascade, as well as induction of proteins from the crystallin family, in response to retinal degeneration. Identification of such pathways may contribute to new therapeutic approaches.  相似文献   

13.
A novel universal neuropeptide display approach in the mass range of 300-5000 Da was developed to complement two-dimensional gel electrophoresis in the analysis of peptides and small proteins from brain tissue samples. For the analysis of neuropeptides we utilized on-line nanoscale capillary reversed phase liquid chromatography and electrospray ionization quadrupole-time of flight mass spectrometry. The method was employed for the analysis of a large number of peptides from three specific rat brain regions. Approximately 1500 peptides from each brain region were detected in the same analysis. Several of these peptides were sequenced using collision-induced dissociation and identified by database search tools. In addition, a method for comparing peptide elution profiles between samples was developed, to provide two- and three-dimensional computer graphics of the profiles and to pinpoint differences for statistical measurements. Among the characterized peptides were fragments from proteins such as hemoglobin, alpha-synuclein, stathmin, cyclophilin, actin, NADH dehydrogenase, cytochrome c oxidase and prosomatostatin, as well as the bioactive neuropeptides W-hemorphin-4, and LW-hemorphin-7. The present study showed that the combination of nanoscale reversed phase liquid chromatography and high-resolution tandem mass spectrometry provides a novel and powerful approach to investigate a large number of peptides and protein fragments in the brain.  相似文献   

14.
Sample pretreatment was optimized to obtain high sequence coverage for human serum albumin (HSA, 66.5 kDa) when using nano-electrospray ionization quadrupole time-of-flight mass spectrometry (nESI–Q-TOF–MS). Use of the final method with trypsin, Lys-C, and Glu-C digests gave a combined coverage of 98.8%. The addition of peptide fractionation resulted in 99.7% coverage. These results were comparable to those obtained previously with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF–MS). The sample pretreatment/nESI–Q-TOF–MS method was also used with collision-induced dissociation to analyze HSA digests and to identify peptides that could be employed as internal mass calibrants in future studies of modifications to HSA.  相似文献   

15.
Proteomics is the study of proteins, their time- and location-dependent expression profiles, as well as their modifications and interactions. Mass spectrometry is useful to investigate many of the questions asked in proteomics. Database search methods are typically employed to identify proteins from complex mixtures. However, databases are not often available or, despite their availability, some sequences are not readily found therein. To overcome this problem, de novo sequencing can be used to directly assign a peptide sequence to a tandem mass spectrometry spectrum. Many algorithms have been proposed for de novo sequencing and a selection of them are detailed in this article. Although a standard accuracy measure has not been agreed upon in the field, relative algorithm performance is discussed. The current state of the de novo sequencing is assessed thereafter and, finally, examples are used to construct possible future perspectives of the field.  相似文献   

16.
Delahunty CM  Yates JR 《BioTechniques》2007,43(5):563, 565, 567 passim
Large-scale biology emerged out of the efforts to sequence genomes of important organisms. Based on resources created by whole genome sequencing, large-scale analyses of messenger RNA (mRNA) and protein expression are now possible. With the availability of large amounts of genomic sequence information, a convenient method for the identification and analysis of proteins based on proteolytic digestion into peptides emerged. Processes to fragment peptides using collision-activated dissociation (CAD) in tandem mass spectrometers and computer algorithms to match the tandem mass spectra of peptides to sequences in databases enable rapid identification of amino acid sequences, and hence proteins, present in mixtures. The inherent complexity of the peptide mixtures has necessitated improvements in methodology for mass spectrometry (MS) analysis of peptides.  相似文献   

17.
Protein-nucleic acid complexes are commonly studied by photochemical cross-linking. UV-induced cross-linking of protein to nucleic acid may be followed by structural analysis of the conjugated protein to localize the cross-linked amino acids and thereby identify the nucleic acid binding site. Mass spectrometry is becoming increasingly popular for characterization of purified peptide-nucleic acid heteroconjugates derived from UV cross-linked protein-nucleic acid complexes. The efficiency of mass spectrometry-based methods is, however, hampered by the contrasting physico-chemical properties of nucleic acid and peptide entities present in such heteroconjugates. Sample preparation of the peptide-nucleic acid heteroconjugates is, therefore, a crucial step in any mass spectrometry-based analytical procedure. This study demonstrates the performance of four different MS-based strategies to characterize E. coli single-stranded DNA binding protein (SSB) that was UV-cross-linked to a 5-iodouracil containing DNA oligomer. Two methods were optimized to circumvent the need for standard liquid chromatography and gel electrophoresis, thereby dramatically increasing the overall sensitivity of the analysis. Enzymatic degradation of protein and oligonucleotide was combined with miniaturized sample preparation methods for enrichment and desalting of cross-linked peptide-nucleic acid heteroconjugates from complex mixtures prior to mass spectrometric analysis. Detailed characterization of the peptidic component of two different peptide-DNA heteroconjugates was accomplished by matrix-assisted laser desorption/ionization mass spectrometry and allowed assignment of tryptophan-54 and tryptophan-88 as candidate cross-linked residues. Sequencing of those peptide-DNA heteroconjugates by nanoelectrospray quadrupole time-of-flight tandem mass spectrometry identified tryptophan-54 and tryptophan-88 as the sites of cross-linking. Although the UV-cross-linking yield of the protein-DNA complex did not exceed 15%, less than 100 pmole of SSB protein was required for detailed structural analysis by mass spectrometry.  相似文献   

18.
Timely classification and identification of bacteria is of vital importance in many areas of public health. Mass spectrometry-based methods provide an attractive alternative to well-established microbiologic procedures. Mass spectrometry methods can be characterized by the relatively high speed of acquiring taxonomically relevant information. Gel-free mass spectrometry proteomics techniques allow for rapid fingerprinting of bacterial proteins using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or, for high-throughput sequencing of peptides from protease-digested cellular proteins, using mass analysis of fragments from collision-induced dissociation of peptide ions. The latter technique uses database searching of product ion mass spectra. A database contains a comprehensive list of protein sequences translated from protein-encoding open reading frames found in bacterial genomes. The results of such searches allow the assignment of experimental peptide sequences to matching theoretical bacterial proteomes. Phylogenetic profiles of sequenced peptides are then used to create a matrix of sequence-to-bacterium assignments, which are analyzed using numerical taxonomy tools. The results thereof reveal the relatedness between bacteria, and allow the taxonomic position of an investigated strain to be inferred.  相似文献   

19.
Timely classification and identification of bacteria is of vital importance in many areas of public health. Mass spectrometry-based methods provide an attractive alternative to well-established microbiologic procedures. Mass spectrometry methods can be characterized by the relatively high speed of acquiring taxonomically relevant information. Gel-free mass spectrometry proteomics techniques allow for rapid fingerprinting of bacterial proteins using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or, for high-throughput sequencing of peptides from protease-digested cellular proteins, using mass analysis of fragments from collision-induced dissociation of peptide ions. The latter technique uses database searching of product ion mass spectra. A database contains a comprehensive list of protein sequences translated from protein-encoding open reading frames found in bacterial genomes. The results of such searches allow the assignment of experimental peptide sequences to matching theoretical bacterial proteomes. Phylogenetic profiles of sequenced peptides are then used to create a matrix of sequence-to-bacterium assignments, which are analyzed using numerical taxonomy tools. The results thereof reveal the relatedness between bacteria, and allow the taxonomic position of an investigated strain to be inferred.  相似文献   

20.
Desorption electrospray ionization (DESI) was utilized to monitor the presence of targeted central carbon metabolites within bacterial cell extracts and the quench supernatant of Escherichia coli. The targeted metabolites were identified through tandem mass spectrometry (MS/MS) product ion scans using collision-induced dissociation in the negative ion mode. Picogram detection limits were achieved for a majority of the metabolites during MS/MS analysis of standard metabolite solutions. In a [U-(13)C]glucose pulse experiment, where uniformly labeled glucose was fed to E. coli, the corresponding fragment ions from labeled metabolites in extracts were generally observed. There was evidence of matrix effects including moderate suppression by other metabolites within the spectra of the labeled and unlabeled extracts. To improve the specificity and sensitivity of detection, optimized in situ ambient chemical reactions using DESI and extractive electrospray ionization (EESI) were carried out for targeted compounds. This study provides the first indication of the potential to perform in situ targeted metabolomics of a bacterial sample via ambient ionization mass spectrometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号