首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
In this article, a novel, label-free, and inherent electroactive redox immunosensor for carcinoembryonic antigen (CEA) based on gold nanoparticles (AuNPs) and Nile blue A (NB) hybridized electrochemically reduced graphene oxide (NB–ERGO) is proposed. The composite of NB–graphene oxide (NB–GO) was prepared by π–π stacking interaction. Then, chronoamperometry was adopted to simultaneously reduce HAuCl4 and nanocomposites of NB–GO for synthesizing AuNPs/NB–ERGO. The immunosensor was fabricated by capturing CEA antibody (anti-CEA) at this nanocomposite modified electrode. The immunosensor determination was based on the fact that, due to the formation of antigen–antibody immunocomplex, the decreased response currents of NB were directly proportional to the concentrations of CEA. Under optimal conditions, the linear range of the proposed immunosensor was estimated to be from 0.001 to 40 ng ml−1 and the detection limit was estimated to be 0.00045 ng ml−1. The proposed immunosensor was used to determine CEA in clinical serum samples with satisfactory results. The proposed method may provide promising potential application in clinical immunoassays with the properties of facile procedure, stability, high sensitivity, and selectivity.  相似文献   

2.
Prostate-specific antigen (PSA), as the specificity of prostate cancer markers, has been widely used in prostate cancer diagnosis and screening. In this study, we fabricated an electrochemical immunosensor for PSA detection using the amino-functionalized graphene sheet–ferrocenecarboxaldehyde composite materials (NH2-GS@FCA) and silver hybridized mesoporous silica nanoparticles (Ag@NH2-MCM48). Under optimal conditions, the fabricated immunosensor showed a wide linear range with PSA concentration (0.01–10.0 ng·ml−1). Low detection limit (2 pg·ml−1) proved the high sensitivity. In addition, the immunosensor possessed good stability and reproducibility. Moreover, the application to PSA analysis in serum samples yielded satisfactory results.  相似文献   

3.
In this work, a novel thiol aromatic aldehyde was synthesized. It can be used as a substrate to directly immobilize antibodies on a gold electrode, for which no additional chemical cross-linker is required. It was also applied as a linker to prepare Fe3O4@Au/PAMAM/Ab2–horseradish peroxidase bioconjugates, which introduced multiple enzymes onto a sensing interface owing to the high surface-to-volume ratio of Fe3O4@Au nanoparticles and many functional groups of the poly(amidoamine) dendrimer (PAMAM). The introduced multiple enzymes greatly improved the detection signal. Under optimal conditions, the proposed electrochemical immunosensor exhibited desirable performance for detection of IgG in the range 0.005–50 ng ml−1 with a detection limit of 3 pg ml−1 based on a signal-to-noise ratio of 3. It has great potential application in the area of clinical analysis.  相似文献   

4.
Accurate and highly sensitive evaluation of the sirtuin 1 (SirT1) level is becoming increasingly important for understanding the contribution of SirT1 in metabolism pathways. Here, a novel electrochemical immunoassay of SirT1 based on crosslinked hyperbranched azo-polymer decorated with gold colloids (Au–HAP) as sensing platform and titanium dioxide (TiO2)–Au nanocomposites to immobilize secondary antibody–horseradish peroxidase (Ab2–HRP) as electrochemical labels has been designed. Greatly enhanced sensitivity was achieved by exploiting the excellent conductivity of Au nanoparticle, the amplification effect of Au–HAP and TiO2–Au, and the favorable catalytic ability of HRP. The nanocomposites of Au–HAP and TiO2–Au could attach numerous capture antibodies on the surface for significant immune recognition efficiency. Meanwhile, the TiO2–Au-labeled Ab2–HRP using an HRP–thionine–H2O2 (hydrogen peroxide) detection system could further induce signal readout. Under optimal conditions, the signal intensity was linearly related to the concentration of SirT1 in the range of 1–500 ng ml−1, and the limit of detection was 0.28 ng ml−1. The developed biosensor exhibits attractive performance for the analysis of SirT1, with rapid response, high sensitivity, and high accuracy, and could become a promising technique for protein detection.  相似文献   

5.
A label-free electrochemical immunosensor based on Nafion/carbon nanotubes (CNTs)/charged pyridinecarboxaldehyde composite film was developed for the detection of hepatitis B surface antigen. Nafion/CNTs/charged pyridinecarboxaldehyde nanocomposites were prepared by dispersing charged pyridinecarboxaldehyde and CNTs in Nafion solution. The nanocomposites were cast on the electrode surface to form aldehyde-terminated composite film that can covalently bind antibody on the film without using other reagent. The immunosensor response was linearly changed with hepatitis B surface antigen concentration in the range from 0.1 to 25 ng ml−1 with a detection limit (signal/noise ratio = 3) of 0.04 ng ml−1. Some important advantages such as simple preparation, good stability, reproducibility, and selectivity of the immunosensor were achieved.  相似文献   

6.
In this study, a novel sensitive electrochemiluminescence (ECL) immunosensor was constructed by carboxyl graphene (GR) for enhancing luminol–O2 system emission. Here, carboxyl GR was used to enhance the ECL intensity of luminol that had excellent electron transfer ability and good solubility. The sensing platform was constructed by depositing carboxyl GR on electrodes and immobilizing antibodies on the surface of carboxyl GR through amidation. The specific immunoreaction between α-fetoprotein (AFP) and antibodies resulted in a decrease of ECL intensity, and the intensity decreased linearly with AFP concentrations in the range of 5 pg ml−1 to 14 ng ml−1 with a detection limit of 2.0 pg ml−1. The proposed immunosensor exhibits high specificity, good reproducibility, and longtime stability. It may become a promising technique for protein detection.  相似文献   

7.
In this study, a novel tracer, horseradish peroxidase (HRP) functionalized gold nanorods (Au NRs) nanocomposites (HRP–Au NRs), was designed to label the signal antibodies for sensitive electrochemical measurement of alpha-fetoprotein (AFP). The preparation of HRP–Au NRs nanocomposites and the labeling of secondary antibody (Ab2) were performed by one-pot assembly of HRP and Ab2 on the surface of Au NRs. The immunosensor was fabricated by assembling carbon nanotubes (CNTs), Au NRs, and capture antibodies (Ab1) on the glassy carbon electrode. In the presence of AFP antigen, the labels were captured on the surface of the Au NRs/CNTs via specific recognition of antigen–antibody, resulting in the signal intensity being clearly increased. Differential pulse voltammetry (DPV) was employed to record the response signal of the immunosensor in phosphate-buffered saline (PBS) containing hydrogen peroxide (H2O2) and 3,3′,5,5′-tetramethylbenzidine (TMB). Under optimal conditions, the signal intensity was linearly related to the concentration of AFP in the range of 0.1–100 ng ml−1, and the limit of detection was 30 pg ml−1 (at signal/noise [S/N] = 3). Furthermore, the immunoassay method was evaluated using human serum samples, and the recovery obtained was within 99.0 and 102.7%, indicating that the immunosensor has potential clinical applications.  相似文献   

8.
In this work, a multiplexed electrochemical immunosensor was developed for sensitive detection of carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) using silver nanoparticles (Ag NPs) or gold nanoparticles (Au NPs) coated-carbon nanospheres (CNSs) as labels. CNSs were employed as the carrier for the immobilization of nanoparticles (Ag NPs or Au NPs), thionine (Thi), and secondary antibodies (Ab2) due to their good monodispersity and uniform structure. Au NPs reduced graphene oxide (rGO) nanocomposites were used as sensing substrate for assembling two primary antibodies (Ab1). In the presence of target proteins, two labels were attached onto the surface of the rGO/Au NPs nanocomposites via a sandwich immunoreaction. Two distinguishable peaks, one at +0.16 V (corresponding to Ag NPs) and another at −0.33 V (corresponding to Thi), were obtained in differential pulse voltammetry (DPV). The peak difference was approximately 490 mV, indicating that CEA and AFP can be simultaneously detected in a single run. Under optimal conditions, the peak currents were linearly related to the concentrations of CEA or AFP in the range of 0.01–80 ng ml−1. The detection limits of CEA and AFP were 2.8 and 3.5 pg ml−1, respectively (at a signal-to-noise ratio of 3). Moreover, when the immunosensor was applied to serum samples, the results obtained were in agreement with those of the reference method, indicating that the immunosensor would be promising in the application of clinical diagnosis and screening of biomarkers.  相似文献   

9.
This paper reports a label-free electrochemical immunosensor for the determination of aflatoxin B1 (AFB1), which is based on a gold electrode modified by a biocompatible film of carbon nanotubes/poly(diallyldimethylammoniumchloride)/Pd–Au nanoparticles (CNTs/PDDA/Pd–Au). The nanocomposite was characterized by transmission electron microscopy and the electrochemical behavior of modified electrodes was investigated by cyclic voltammetry. The CNTs/PDDA/Pd–Au nanocomposites film showed good electron transfer ability, which ensured high sensitivity to detect AFB1 in a range from 0.05 to 25 ng mL−1 with a detection limit of 0.03 ng mL−1 obtained at 3σ (where σ is the standard deviation of the blank solution, n = 10). The proposed immunosensor provides a simple tool for AFB1 detection. This strategy can be extended to any other antigen detection by using the corresponding antibodies.  相似文献   

10.
An electrochemical immunosensor for quantitative detection of α-fetoprotein (AFP) in human serum was developed using graphene sheets (GS) and thionine (TH) as electrode materials and mesoporous silica nanoparticles (MSNs) loaded with ferroferric oxide (Fe3O4) nanoparticles and horseradish peroxidase (HRP) as labels for signal amplification. In this study, the compound of GS and TH (GS–TH) was used as a substrate for promoting electron transfer and immobilization of primary antibody of AFP (Ab1). MSNs were used as a carrier for immobilization of secondary antibody of AFP (Ab2), Fe3O4, and HRP. The synergistic effect occurred between Fe3O4 and HRP and greatly improved the sensitivity of the immunosensor. This method could detect AFP over a wide concentration range from 0.01 to 25 ng ml−1 with a detection limit of 4 pg ml−1. This strategy may find wide potential application in clinical analysis or detection of other tumor markers.  相似文献   

11.
A new polymer bearing aldehyde groups was designed and synthesized by grafting 4-pyridinecarboxaldehyde onto poly(epichlorohydrin). Antibodies can be directly immobilized on the surface of the polymer film through the covalent bonding of aldehyde groups of the film with amino groups of antibodies. In this study, human immunoglobulin G (IgG) was used as a model analyte for the fabrication of an electrochemical impedance immunosensor. Using the proposed immunosensor, IgG in the range from 0.1 to 80 ng ml−1 was detected with a detection limit of 0.07 ng ml−1 (signal/noise [S/N] = 3). In addition, the electrochemical impedance immunosensor displays good stability and reproducibility.  相似文献   

12.
A novel immunosensor for α-1-fetoprotein based on dialdehyde cellulose/ionic liquid composite film as a matrix has been developed. Microcrystalline cellulose was activated by sodium metaperiodate to produce dialdehyde cellulose. Antibodies can be immobilized on the electrode by a one-step method through covalent bonding of the aldehyde groups of dialdehyde cellulose with the amino groups of antibodies, in which no additional chemical cross-linking step is required. Moreover, ionic liquid added can improve the conductivity of the sensing interface and, therefore, can enhance the electrochemical signal. In this work, α-1-fetoprotein was detected within the range from 0.1 to 60 ng ml−1 with a detection limit of 0.07 ng ml−1 (signal/noise = 3). The proposed immunosensor had good specificity and reproducibility. It was used to determine real samples with satisfactory results.  相似文献   

13.
A localized surface plasmon resonance immunoassay has been developed to determine prolactin hormone in human serum samples. Gold nanoparticles were synthesized, and the probe was prepared by electrostatic adsorption of antibody on the surfaces of gold nanoparticles. The pH and the antibody-to-gold nanoparticle ratio, as the factors affecting the probe functions, were optimized. The constructed nanobiosensor was characterized by dynamic light scattering. The sensor was applied for the determination of prolactin antigen concentration based on the amount of localized surface plasmon resonance peak shift. A linear dynamic range of 1–40 ng ml−1, a detection limit of 0.8 ng ml−1, and sensitivity of 10 pg ml−1 were obtained. Finally, the nanobiosensor was applied for the determination of prolactin in human control serum sample.  相似文献   

14.
A novel strategy for the fabrication of sensitive immunosensor to detect α-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml−1 with a detection limit of 0.6 ng ml−1. The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

15.
A new electrochemical immunoassay of alpha-fetoprotein (AFP) was developed on an organic–inorganic hybrid nanostructure-functionalized carbon electrode by coupling with magnetic bionanolabels. Multi-walled carbon nanotubes (CNTs), single-stranded DNA, thionine and AFP were utilized for the construction of the immunosensor, while the core–shell Fe3O4-silver nanocomposites were employed for the label of horseradish peroxidase-anti-AFP conjugates (HRP-anti-AFP-AgFe). Electrochemical measurement toward AFP was carried out by using magnetic bionanolabels as traces and H2O2 as enzyme substrate with a competitive-type immunoassay mode. Experimental results indicated that the immunosensors with carbon nanotubes and DNA exhibited better electrochemical responses than those of without carbon nanotubes or DNA. Under optimal conditions, the electrochemical immunosensor by using HRP-anti-AFP-AgFe as signal antibodies exhibited a linear range of 0.001–200 ng mL−1 AFP with a low detection limit of 0.5 pg mL−1 at 3sB. Both intra- and inter-assay coefficients of variation were 7.3%, 9.4%, 8.7% and 10.2%, 7.8%, 9.4% toward 0.01, 30, 120 ng mL−1 AFP, respectively. The specificity and stability of the electrochemical immunoassay were acceptable. In addition, the methodology was validated for 12 clinical serum specimens including 9 positive specimens and 3 normal specimens, receiving a good correlation with the results obtained from the referenced electrochemiluminescence assay.  相似文献   

16.
This work reports a novel signal amplification strategy based on three-dimensional ordered macroporous C60-poly(3,4-ethylenedioxythiophene)-1-butyl-3-methylimidazolium hexafluorophosphate (3DOM C60-PEDOT-[BMIm][BF6]) for ultrasensitive detection of thrombin by cascade catalysis of Au-PEDOT@SiO2 microspheres and alcohol dehydrogenase (ADH). Au-PEDOT@SiO2 microspheres were constructed not only as nanocarriers to anchor the large amounts of secondary thrombin aptamers but also as nanocatalysts to catalyze the oxidation of ethanol efficiently. Significantly, the electrochemical signal was greatly enhanced based on cascade catalysis: First, ADH catalyzed the oxidation of ethanol to acetaldehyde with the concomitant generation of NADH in the presence of β-nicotinamide adenine dinucleotide hydrate (NAD+). Then, gold nanoparticles (AuNPs) as nanocatalysts could effectively catalyze NADH to produce NAD+ with the help of PEDOT as redox probe. Under the optimal conditions, the proposed aptasensor exhibits a linear range of 2 × 10−13 to 2 × 10−8 M with a low detection limit of 2 × 10−14 M for thrombin detection and shows high sensitivity and good specificity.  相似文献   

17.
A label-free amperometric immunosensor for fast and sensitive assay of human serum chorionic gonadotropin (hCG) is presented. hCG was immobilized on nanoporous gold (NPG) foils and using hydroquinone (HQ) redox species as indicator. The variation of amperometric response to the concentration of hCG, the target antigen, was evaluated by cyclic voltammetry in phosphate-buffered solution. Taking advantage of dual-amplification effects of the NPG foils and graphene sheets (GSs), the immunosensor exhibited a specific response to hCG in the range of 0.5–40.00 ng ml−1 with a detection limit of 0.034 ng ml−1 under optimal conditions. It was demonstrated that our proposed method possesses good accuracy, acceptable precision, and reproducibility. The NPG showed a better sensitizing effect and stability as immobilization matrices.  相似文献   

18.
A signal amplificatory electrochemical immunoassay with biotin-streptavidin conjunction and multienzymatic-based substrate recycling was developed in this work. Biotinylated secondary antibody (bio-IgG) was preliminarily assembled onto the immunosensor interface based on the sandwich format. Streptavidin was then loaded based on biotin-streptavidin conjunction. Owing to four identical binding sites of streptavidin to biotin, amounts of biotinylated alkaline phosphatase (bio-AP) were attached, and this improved the catalytic performance of the proposed immunosensor. Under the enzyme catalysis of AP, the electroinactive p-aminophenylphosphate (PAPP) substrate was rapidly hydrolyzed into the electroactive p-aminophenol (PAP) product, which next oxidized at the electrode surface into p-quinoneimine (PQI). In the presence of diaphorase (DI), PQI was reduced back to PAP, leading to a reversible cycle of PAP. Then the oxidized state of DI was regenerated into its reduced native state by its natural substrate, nicotinamide adenine dinucleotide (NADH). With the several amplification factors mentioned above, a wider linear ranged from 10−14 to 10−5 g ml−1 was acquired with a relatively low detection limit of 3.5 × 10−5 g ml−1 for human IgG. In addition, the nonspecific adsorption of proposed immunosensor was also investigated here.  相似文献   

19.
This work presents a cloud-point extraction process using the micelle-mediated extraction method for simultaneous preconcentration and determination of Sb(III) and Sb(V) species in biological and environmental samples as a prior preconcentration step to their spectrophotometric determination. The analytical system is based on the selective reaction between Sb(III) and 3-dichloro-6-(3-carboxy-2-hydroxy-1-naphthylazo)quinoxaline (DCHNAQ) in the presence of cetyltrimethylammonium bromide (CTAB) and potassium iodide at pH 4.5. Total Sb concentration was determined after reduction of Sb(V) to Sb(III) in the presence of potassium iodide and ascorbic acid. The optimal reaction conditions and extraction were studied, and the analytical characteristics of the method (e.g., limits of detection and quantification, linear range, preconcentration, improvement factors) were obtained. Linearity for Sb(III) was obeyed in the range of 0.2–20 ng ml−1. The detection and quantification limits for the determination of Sb(III) were 0.055 and 0.185 ng ml−1, respectively. The method has a lower detection limit and wider linear range, inexpensive instrument, and low cost, and is more sensitive compared with most other methods. The interference effect of some anions and cations was also studied. The method was applied to the determination of Sb(III) in the presence of Sb(V) and total antimony in blood plasma, urine, biological, and water samples.  相似文献   

20.
In this work, a novel sandwich-type electrochemical immunosensor has been developed for simultaneous detection of carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) based on metal ion labels. Gold nanoparticles decorated multiwall carbon nanotubes (AuNPs@MWCNTs) were used as carriers to immobilize secondary antibodies and distinguishable electrochemical tags of Pb2+ and Cd2+ to amplify the signals. Due to the intrinsic property of high surface-to-volume ratio, the AuNPs@MWCNTs could load numerous secondary antibodies and labels. Therefore, the multiplexed immunoassay exhibited good sensitivity and selectivity. Experimental results revealed that this sandwich-type immunoassay displayed an excellent linear response, with a linear range of 0.01 to 60 ng mL–1 for both analytes and detection limits of 3.0 pg mL–1 for CEA and 4.5 pg mL–1 for AFP (at a signal-to-noise ratio of 3). The method was successfully applied for the determination of AFP and CEA levels in clinical serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号