首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
A renewable three-dimensional chemically modified carbon ceramic electrode (CCE) containing nickel powder and K4[Mo(CN)8] was constructed by sol-gel technique. The electrochemical properties and stability of modified electrode was evaluated by cyclic voltammetry in pH range 4-10. The redox couple of [Mo(CN)8] (4-/3-) was shown both as a solute in electrolyte solution and as a component of a carbon based conducting composite electrode. The apparent electron transfer rate constant (ks) and transfer coefficient (alpha) were determined by cyclic voltammetry and they were about 17.1 and 0.57 s(-1), respectively. The catalytic activity of the modified CCE toward insulin oxidation was investigated at pH range of 3-8 by cyclic votammetry. The modified electrode showed excellent electrocatalytic activity toward insulin electroxidation at physiological pH value. The modified electrode was used for insulin detection chronoamperometrically at pH 7. Under optimized condition in amperometry method, the concentration calibration range, detection limit and sensitivity were 0.5-500 nM, 0.45 nM and 6140 nA/microM, respectively. Flow injection amperometric determination of insulin at pH 7.4, at this modified electrode yielded a calibration curve with the following characteristics, linear dynamic range 100-500 pM; sensitivity 8.1 nA/nM and detection limit 40 pM (based on S/N = 3). The inherent stability at wide pH range, high sensitivity, low detection limit, low cost and ease of preparation are of advantageous of this insulin sensor. This sensor indicates great promise for monitory insulin in chromatographic effluents.  相似文献   

2.
This work describes a new electrochemical sensor for hydrogen peroxide based on tin pentacyanonitrosylferrate (SnPCNF)-modified carbon ceramic electrode (CCE). The modified electrode was constructed by using a sol-gel technique involving two steps: construction of CCE containing metallic tin (Sn) powder and then electrochemical creation of SnPCNF film on the surface of CCE. The modified electrode was characterized by energy-dispersive X-ray, Fourier transform infrared, scanning electron microscopy, and cyclic voltammetry (CV) techniques. The charge transfer coefficient (α) and charge transfer rate constant (ks) for the modifying film were calculated. The electrocatalytic activity of the modified electrode toward the reduction of hydrogen peroxide was studied by CV and chronoamperometry. A linear calibration curve was obtained over the hydrogen peroxide concentration range of 0.5 to 69.4 μM using a hydrodynamic amperometric technique. The limit of detection (for a signal-to-noise ratio of 3) and sensitivity were found to be 92 nM and 0.89 μA/μM, respectively. Furthermore, the diffusion coefficient of hydrogen peroxide (D) and catalytic rate constant (kcat) were calculated.  相似文献   

3.
This work describes the electrochemical and electrocatalytic properties of carbon ceramic electrode (CCE) modified with lead nitroprusside (PbNP) nanoparticles as a new electrocatalyst material. The structure of deposited film on the CCE was characterized by energy dispersive X-ray (EDX), Fourier transform infrared (FTIR), and scanning electron microscopy (SEM). The cyclic voltammogram (CV) of the PbNP modified CCE showed two well-defined redox couples due to [Fe(CN)5NO]3−/[Fe(CN)5NO]2− and PbIV/PbII redox reactions. The modified electrode showed electrocatalytic activity toward the oxidation of l-cysteine and was used as an amperometric sensor. Also, to reduce the fouling effect of l-cysteine and its oxidation products on the modified electrode, a thin film of Nafion was coated on the electrode surface. The sensor response was linearly changed with l-cysteine concentration in the range of 1 × 10−6 to 6.72 × 10−5 mol L−1 with a detection limit (signal/noise ratio [S/N] = 3) of 0.46 μM. The sensor sensitivity was 0.17 μA (μM)−1, and some important advantages such as simple preparation, fast response, good stability, interference-free signals, antifouling properties, and reproducibility of the sensor for amperometric determination of l-cysteine were achieved.  相似文献   

4.
A three-dimensional (3D) continuous and interconnected network graphene foam (GF) was synthesized by chemical vapor deposition using nickel foam as a template. The morphologies of the GF were observed by scanning electron microscopy. X-ray diffraction and Raman spectroscopy were used to investigate the structure of GF. The graphene with few layers and defect free was closely coated on the backbone of the 3D nickel foam. After etching nickel, the GF was transferred onto indium tin oxide (ITO) glass, which acted as an electrode to detect uric acid using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The GF/ITO electrode showed a high sensitivity for the detection of uric acid: approximately 9.44 mA mM−1 in the range of 25 nM–0.1 μM and 1.85 mA mM−1 in the range of 0.1–60 μM. The limit of detection of GF/ITO electrode for uric acid is 3 nM. The GF/ITO electrode also showed a high selectivity for the detection of uric acid in the presence of ascorbic acid. This electrode will have a wide range of potential application prospects in electrochemical detection.  相似文献   

5.
This study reports the synthesis and characterization of a novel nanostructure-based electrode for electrochemical studies and determination of captopril (CP). At first manganese titanate nanoceramics were synthesized by the sol–gel method. The structural evaluations of the pure nanopowders were investigated by different techniques such as X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Then it was used to prepare a new nanostructured manganese titanate carbon paste electrode (MnTiO3/CPE). The characterization of the modified sensor was carried out by comprehensive techniques such as electrochemical impedance spectroscopy (EIS), SEM, and voltammetry. Subsequently, the modified electrode was used for CP catalytic oxidation in the presence of para-aminobenzoic acid (PABA) as a mediator. The results showed that PABA has high catalytic activity for CP oxidation. The electrochemical behavior of CP was studied by cyclic voltammetry (CV), linear sweep voltammetry (LSV), chronoamperometry (CHA), and differential pulse voltammetry (DPV) techniques. Under the optimized conditions, the catalytic oxidation peak current of CP showed two linear dynamic concentration ranges of 1.0 × 10−8 to 1.0 × 10−7 and 1.0 × 10−7 to 1.0 × 10−6, with a detection limit of 1.6 nM (signal/noise = 3), using the DPV technique. Finally, the proposed method was successfully applied for determination of CP in pharmaceutical and biological samples.  相似文献   

6.
Cytochrome c was immobilized covalently onto nickel oxide nanoparticles/carboxylated multiwalled carbon nanotubes/polyaniline composite (NiO-NPs/cMWCNT/PANI) electrodeposited on gold (Au) electrode. An amperometric H2O2 biosensor was constructed by connecting this modified Au electrode along Ag/AgCl as reference and Pt wire as counter electrode to the galvanostat. The modified Au electrode was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and Fourier transform infra-red spectroscopy (FTIR). Cyclic voltammetric (CV) studies of the electrode at different stages demonstrated that the modified Au electrode had enhanced electrochemical oxidation of H2O2, which offered a number of attractive features to develop an amperometric biosensor based on split of H2O2. There was a good linear relationship between the current (mA) and H2O2 concentration in the range 3–700 μM. The sensor had a detection limit of 0.2 μM (S/N = 3) with a high sensitivity of 3.3 mA μM?1 cm?2. The sensor gave accurate and satisfactory results, when employed for determination of H2O2 in different fruit juices.  相似文献   

7.
A new electrochemical sensor for the determination of norepinephrine (NE), acetaminophen (AC) and tryptophan (Trp) is described. The sensor is based on carbon paste electrode (CPE) modified with 3,4-dihydroxybenzaldehyde-2,4-dinitrophenylhydrazone (DDP) and takes the advantages of carbon nanotubes (CNTs), which makes the modified electrode highly sensitive for the electrochemical detection of these compounds. Cyclic voltammetry (CV) at various scan rates was used to investigate the redox properties of the modified electrode. The apparent charge transfer rate constant, k(s), and transfer coefficient, α, for electron transfer between DDP and CNT paste electrode were calculated. The mediated oxidation of NE at the modified electrode was investigated by CV and the values of k, α and diffusion coefficient (D) were calculated. Under the optimum pH of 7.0, the oxidation of NE occurs at a potential about 215 mV less positive than that of the unmodified CPE. Differential pulse voltammetry (DPV) of NE at the modified electrode exhibited two linear dynamic ranges with a detection limit (3σ) of 77±2 nM. DPV was used for simultaneous determination of NE, AC and Trp at the modified electrode, and quantitation of NE in some real samples by the standard addition method.  相似文献   

8.

Metformin (Mf) plays a major role in controlling insulin level of individuals at risk of developing diabetes mellitus. Overdose of Mf can cause lactic acidosis, diarrhoea, cough, or hoarseness, etc. These particulars point out the identification for selective and sensitive methods of Mf determination. In the present work, graphene nanoflakes-polymethylene blue (GNF-PMB) nano-composites were developed onto fluorine-doped tin oxide (SnO2/F) coated glass substrates for electrochemical sensing of Mf using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The developed sensor shows quick response time (10 s), linearity as 10–103 µM, LOD (0.1 nM), and good shelf life (10 weeks). Attempts have been made to utilize this electrode for estimation of Mf in urine samples. Configured as a highly responsive, reproducible Mf sensor, it combines the electrical properties of GNF and stable electron transfer of PMB. The newly developed Mf sensor presents a promising candidate in point-of-care diagnosis.

  相似文献   

9.
The electrochemical behavior of insulin at glassy carbon (GC) electrode modified with nickel oxide nanoparticles and guanine was investigated. Cyclic voltammetry technique has been used for electrodeposition of nickel oxide nanoparticles (NiOx) and immobilization of guanine on the surface GC electrode. In comparison to glassy carbon electrode modified with nickel oxide nanoparticles and bare GC electrode modified with adsorbed guanine, the guanine/nickel oxide nanoparticles/modified GC electrode exhibited excellent catalytic activity for the oxidation of insulin in physiological pH solutions at reduced overpotential. The modified electrode was applied for insulin detection using cyclic voltammetry or hydrodynamic amperometry techniques. It was found that the calibration curve was linear up to 4muM with a detection limit of 22pM and sensitivity of 100.9pA/pM under the optimized condition for hydrodynamic amperometry using a rotating disk modified electrode. In comparison to other electrochemical insulin sensors, this sensor shows many advantages such as simple preparation method without using any special electron transfer mediator or specific reagent, high sensitivity, excellent catalytic activity at physiological pH values, short response time, long-term stability and remarkable antifouling property toward insulin and its oxidation product. Additionally, it is promising for the monitoring of insulin in chromatographic effluents.  相似文献   

10.
A highly sensitive electrochemical glucose sensor has been developed by the co-immobilization of glucose oxidase (GOx) and horseradish peroxidase (HRP) onto a gold electrode modified with biocompatible cyclic bisureas–gold nanoparticle conjugate (CBU–AuNP). A self-assembled monolayer of mercaptopropionic acid (MPA) and CBU–AuNP was formed on the gold electrode through a layer-by-layer assembly. This modified electrode was used for immobilization of the enzymes GOx and HRP. Both the HRP and GOx retained their catalytic activity for an extended time, as indicated by the low value of Michaelis–Menten constant. Analytical performance of the sensor was examined in terms of sensitivity, selectivity, reproducibility, lower detection limit, and stability. The developed sensor surface exhibited a limit of detection of 100 nM with a linear range of 100 nM to 1 mM. A high sensitivity of 217.5 μA mM−1 cm−2 at a low potential of −0.3 V was obtained in this sensor design. Various kinetic parameters were calculated. The sensor was examined for its practical clinical application by estimating glucose in human blood sample.  相似文献   

11.
Measurement of the uric acid level in the body can be improved by biosensing with respect to the accuracy, sensitivity and time consumption. This study has reported the immobilization of uricase onto graphene oxide (GO) and its function for electrochemical detection of uric acid. Through chemical modification of GO using 1-ethyl-3-(dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysulfosuccinimide (NHS) as cross-linking reagents, the enzyme activity of the immobilized uricase was much comparable to the free enzyme with 88% of the activity retained. The modified GO-uricase (GOU) was then subjected to electrocatalytic detection of uric acid (UA) via cyclic voltammetry (CV). For that reason, a glassy carbon electrode (GCE) was modified by adhering the GO along with the immobilized uricase to facilitate the redox reaction between the enzyme and the substrate. The modified GOU/GCE outperformed a bare electrode through the electrocatalytic activity with an amplified electrical signal for the detection of UA. The electrocatalytic response showed a linear dependence on the UA concentration ranging from 0.02 to 0.49 mM with a detection limit of 3.45 μM at 3σ/m. The resulting biosensor also exhibited a high selectivity towards UA in the presence of other interference as well as good reproducibility.  相似文献   

12.
Novel nickel and copper oxide nanoparticle modified polyaniline (PANI) nanofibers (NiO/CuO/PANI) were fabricated and used as a non-enzymatic sensor for detecting glucose. PANI nanofibers were prepared through electrodeposition, whereas nickel and copper oxide nanoparticles were deposited on PANI nanofibers by electrodeposition and electrochemical oxidation in situ. The morphology and structure of NiO/CuO/PANI nanocomposites were characterized by field emission scanning electron microscopy (FE–SEM), X-ray diffraction (XRD), Raman spectroscopy, and Fourier transform infrared (FT–IR). The as-prepared NiO/CuO/PANI electrode was employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electrocatalytic activity compared with the PANI, CuO/PANI, and NiO/PANI electrodes. Consequently, an amperometric electrode of glucose was achieved under 0.6 V versus Ag/AgCl with a wide linear range from 20 to 2500 μM (R2 = 0.9978) and a low detection limit of 2.0 μM (signal/noise [S/N] = 3). This electrode can effectively analyze glucose concentration in human serum samples, avoiding interference, and is a promising non-enzymatic glucose sensor due to its low overpotential, high sensitivity, good selectivity and stability, fast response, and low cost.  相似文献   

13.
A commercial lysine oxidase (LyOx) from Trichoderma viride was immobilized covalently onto gold nanoparticles (AuNPs) and platinum nanoparticles (PtNPs) electrodeposited onto Au electrode using 3-aminopropyltriethoxy silane (3-APTES) and glutaraldehyde cross linking chemistry. A lysine biosensor was fabricated using LyOx/3-APTES/AuNPs-PtNPs/Au electrode as a working electrode, Ag/AgCl (3 M KCl) as standard electrode and Pt wire as auxiliary electrode connected through a potentiostat. The enzyme electrode was characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The cumulative effect of AuNPs and PtNPs showed excellent electrocatalytic activity at low applied potential for detection of H2O2, a product of LyOx reaction. The sensor showed its optimum response within 4 s, when polarized at 0.2 V vs. Ag/AgCl in 0.1 M phosphate buffer, pH 7.5 at 30 °C. The linear range and detection limit of the sensor were 1.0–600 μM and 1.0 μM (S/N = 3), respectively. Biosensor measured lysine level in sera, milk and amino acid tablet, which correlated well with those by standard HPLC method. The enzyme electrode lost 50% of its initial activity after 200 uses over a period of 4 months.  相似文献   

14.
A nonenzymatic electrochemical sensor device was fabricated for glucose detection based on nickel nanoparticles (NiNPs)/straight multi-walled carbon nanotubes (SMWNTs) nanohybrids, which were synthesized through in situ precipitation procedure. SMWNTs can be easily dispersed in solution after mild sonication pretreatment, which facilitates the precursor of NiNPs binding to their surface and results in the homogeneous distribution of NiNPs on the surface of SMWNTs. The morphology and component of the nanohybrids were characterized by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD), respectively. Cyclic voltammetry (CV) and amperometry were used to evaluate the catalytic activity of the NiNPs/SMWNTs nanohybrids modified electrode towards glucose. It was found that the nanohybrids modified electrode showed remarkably enhanced electrocatalytic activity towards the oxidation of glucose in alkaline solution compared to that of the bare glass carbon electrode (GCE), the NiNPs and the SMWNTs modified electrode, attributing to the synergistic effect of SMWNTs and Ni2+/Ni3+ redox couple. Under the optimal detection conditions, the as-prepared sensors exhibited linear behavior in the concentration range from 1 μM to 1 mM for the quantification of glucose with a limit of detection of 500 nM (3σ). Moreover, the NiNPs/SMWNTs modified electrode was also relatively insensitive to commonly interfering species such as ascorbic acid (AA), uric acid (UA), dopamine (DA), galactose (GA), and xylose (XY). The robust selectivities, sensitivities, and stabilities determined experimentally indicated the great potential of NiNPs/SMWNTs nanohybrids for construction of a variety of electrochemical sensors.  相似文献   

15.
A novel non-enzymatic electrochemiluminescence (ECL) sensor based on palladium nanoparticles (PdNPs)–functional carbon nanotubes (FCNTs) was discovered for glucose detection. PdNPs were homogeneously modified on FCNTs using a facile spontaneous redox reaction method. Their morphologies were characterized by transmission electron microscopy (TEM). Based on ECL experimental results, the PdNPs–FCNTs–Nafion film modified electrode displayed high electrocatalytic activity towards the oxidation of glucose. The free radicals generated by the glucose oxidation reacted with the luminol anion (LH), and enhanced the ECL signal. Under the optimized conditions, the linear response of ECL intensity to glucose concentration was valid in the range from 0.5 to 40 μmol L−1 (r2 = 0.9974) with a detection limit (S/N = 3) of 0.09 μmol L−1. In addition, the modified electrode presented high resistance towards the poisoning of chloride ion, high selectivity and long-term stability. In order to verify the sensor reliability, it was applied to the determination of glucose in glucose injection samples. The results indicated that the proposed approach provided a highly sensitive, more facile method with good reproducibility for glucose determination, promising the development of a non-enzymatic ECL glucose sensor.  相似文献   

16.
In this study, a novel electrochemical sensor for quantification of ascorbic acid with amperometric detection in physiological conditions was constructed. For this purpose, cobalt and nickel ferrites were synthesized using microwave and ultrasound assistance, characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, and X-ray powder diffraction (XRPD), and used for modification of glassy carbon paste electrode (GCPE). It was shown that introducing these nanoparticles to the structure of GCPE led to increasing analytical performance. Co ferrite modified GCPE (CoFeGCPE) showed better characteristics toward ascorbic acid sensing. The limit of detection (LOD) obtained by sensor was calculated to be 0.0270 mg/L, with linear range from 0.1758 to 2.6010 mg/L. This sensor was successfully applied for practical analysis, and the obtained results demonstrated that the proposed procedure could be a promising replacement for the conventional electrode materials and time-consuming and expensive separation methods.  相似文献   

17.
Edge plane pyrolytic graphite electrode (EPPGE) modified with single-wall carbon nanotubes (SWNTs) has been used as a sensor to determine triamcinolone, abused by athletes for doping. A comparison of the voltammetric behavior between SWNTs modified EPPGE and fullerene – C60-modified EPPGE indicated that SWNTs modified EPPGE is more sensitive. The electrode exhibited an effective catalytic response with good reproducibility and stability. The effect of several parameters such as pH, square wave frequency and steroid concentration were studied. The square wave voltammetric response of the electrode to triamcinolone is linear in the range 0.1–25 nM with a detection limit and sensitivity of 8.9 × 10−10 M and 2.06 μA nM−1, respectively. The method was applied for the determination of triamcinolone in several commercially available pharmaceuticals and real urine samples obtained from patients undergoing pharmacological treatment with triamcinolone. A comparison of the observed results with HPLC analysis indicated a good agreement. The product obtained after reduction of triamcinolone was also characterized using 1H NMR and GC–MS and the site of reduction is found to be carbonyl group at position 20. The method described is rapid, simple and accurate and can be easily applied for detecting cases of doping.  相似文献   

18.
This paper demonstrated the selective determination of folic acid (FA) in the presence of important physiological interferents, ascorbic acid (AA) and uric acid (UA) at physiological pH using electropolymerized film of 5-amino-2-mercapto-1,3,4-thiadiazole (p-AMT) modified glassy carbon (GC) electrode. Bare GC electrode fails to determine the concentration of FA in the presence of AA and UA due to the surface fouling caused by the oxidized products of AA and FA. However, the p-AMT film modified electrode not only separates the voltammetric signals of AA, UA and FA with potential differences of 170 and 410 mV between AA–UA and UA–FA, respectively but also shows higher oxidation current for these analytes. The p-AMT film modified electrode displays an excellent selectivity towards the determination of FA even in the presence of 200-fold AA and 100-fold UA. Using amperometric method, we achieved the lowest detection of 75 nM UA and 100 nM each AA and FA. The amperometric current response was increased linearly with increasing FA concentration in the range of 1.0 × 10−7–8.0 × 10−4 M and the detection limit was found to be 2.3 × 10−10 M (S/N = 3). The practical application of the present modified electrode was successfully demonstrated by determining the concentration of FA in human blood serum samples.  相似文献   

19.
Glassy carbon (GC) electrode was modified using multi-wall carbon nanotubes (MWCNTs), quercetin (Q) and Nafion® in this sequence. The thus modified electrode was used for the detection of dopamine (DA) in the presence of equimolar ascorbic acid (AA). It is demonstrated in this study that MWCNTs can increase the current response of DA by five-fold and Q can reduce the oxidation overpotential of DA by about 60 mV, compared to these parameters obtained with a bare GC electrode. It is also shown that a layer of Nafion® can virtually eliminate the interference of AA for the detection of DA. The GC/MWCNTs/Q/Nafion® electrode (hereafter also called composite electrode) shows a current density of about 900 μA cm−2 for DA, compared to the value of 80 μA cm−2 of the GC electrode and to the value of 390 μA cm−2 of the GC/MWCNTs electrode. The 11-fold enhancement in the sensitivity of the GC electrode for DA determination is attributed to the composite modification of the electrode, and is substantiated through various cyclic voltammetric experiments. Cyclic voltammetry (CV) and linear sweep voltammetry were used to characterize the electrodes. Calibration curves of batch and flow systems were obtained by amperometry for the detection of DA. Additionally, the composite modified electrode was tested with a human serum sample for the determination of DA and was found to be promising at our preliminary experiments.  相似文献   

20.
A sensitive label-free electrochemical aptasensor was successfully fabricated for thrombin detection with nafion@graphene as platform. With electrostatic interaction between nafion and methylene blue (MB), positive charged MB was successfully assembled on nafion@graphene modified electrode surface, which provided amounts of redox probes for electrochemical aptasensor. In the presence of thrombin, the thrombin aptamer (TBA) on the electrode surface would catch the target on the electrode interface, which made a barrier for electrons and inhibits the electro-transfer, resulting in the decreased differential pulse voltammetry signals of MB. As a result, the proposed approach showed a high sensitivity and a wider linearity to thrombin in the range 0.01–50 nM with a detection limit of 6 pM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号