首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Developing a readily available biosensor with excellent performances is the main focus of many research groups. Recently, major breakthroughs in miniaturization of molecular analysis have produced DNA and protein microarrays. The aim of our group is to develop a sensitive technique for analyzing signals on protein microarray by applying the surface plasmon resonance (SPR) method. This new detection technique for specific molecular binding utilizes rolling circles amplification (RCA) post-signal processing method [Nat. Genet. 19 (1998) 225-232] and optical visualization by nanogold particle-labeled molecules on a micro-structured chip surface. By covalent bonding of the RCA primer to the detection antibody guarantees that the linkage between the analyte and the amplified RCA product is maintained during the assay. Experimental results show that RCA has significantly enhanced sensitivity compared to conventional methods. This combination of an easily detectable signal with chip technology should have the potential to become a successful commercial application.  相似文献   

2.
In this paper we describe the use of a commercial surface plasmon resonance (SPR) imaging instrument for monitoring the binding of biomolecules on user-defined regions of interest of a microarray. By monitoring the angle shift of the SPR-dip using a continuous angle-scanning mode instead of monitoring the change in reflectivity at a fixed angle, a linear relationship with respect to the mass density change on the surface will remain over a wide dynamic angle range of 8 degrees. Peptides (2.4 kDa) and proteins (150 kDa) were both spotted on the same sensor chip to illustrate that both, low and high molecular weight ligands with initial large differences in off-set SPR angles, can be applied within the same experiment. By using a fluorescently labeled antibody, SPR results can be confirmed by means of fluorescence microscopy after completion of a SPR experiment. SPR imaging in angle-scanning operation provides sensitive, accurate, and label-free detection of analyte binding on microarrays containing different molecular weight ligands.  相似文献   

3.
Biomolecular interaction analysis mass spectrometry (BIA/MS) is a two-dimensional analytical technique that quantitatively and qualitatively detects analytes of interests. In the first dimension, surface plasmon resonance (SPR) is utilized for detection of biomolecules in their native environment. Because SPR detection is non-destructive, analyte(s) retained on the SPR-active sensor surface can be analyzed in a second dimension using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The qualitative nature of the MALDI-TOF MS analysis complements the quantitative character of SPR sensing and overcomes the shortcomings of the SPR detection stemming from the inability to differentiate and characterize multi-protein complexes and non-specific binding. In this work, the benefit of performing MS analysis following SPR sensing is established. Retrieval and detection of four markers present in biological fluids (cystatin C, beta-2-microglobulin, urinary protein 1 and retinol binding protein) was explored to demonstrate the effectiveness of BIA/MS in simultaneous detection of clinically related biomarkers and delineation of non-specific binding. Furthermore, the BIA/MS limit of detection at very low SPR responses was investigated. Finally, detection of in-vivo assembled protein complexes was achieved for the first time using BIA/MS.  相似文献   

4.
We propose a surface modification procedure to construct DNA arrays for use in surface plasmon resonance (SPR) imaging studies for the highly sensitive detection of a K-ras point mutation, enhanced with hydrogel nanospheres. A homobifunctional alkane dithiol was adsorbed on Au film to obtain the thiol surface, and ethyleneglycol diglycidylether (EGDE) was reacted to insert the ethyleneglycol moiety, which can suppress nonspecific adsorption during SPR analysis. Then streptavidin (SA) was immobilized on EGDE using tosyl chloride activation. Biotinylated DNA ligands were bound to the SA surface via biotin-SA interaction to fabricate DNA arrays. In SPR analysis, the DNA analyte was exposed on the DNA array and hybridized with the immobilized DNA probes. Subsequently, the hydrogel nanospheres conjugated with DNA probes were bound to the DNA analytes in a sandwich configuration. The DNA-carrying nanospheres led to SPR signal enhancement and enabled us to discriminate a K-ras point mutation in the SPR difference image. The application of DNA-carrying hydrogel nanospheres for SPR imaging assays was a promising technique for high throughput and precise detection of point mutations.  相似文献   

5.
A flexible, non-gel-based single nucleotide polymorphism (SNP) detection method is described. The method adopts thermostable ligation for allele discrimination and rolling circle amplification (RCA) for signal enhancement. Clear allelic discrimination was achieved after staining of the final reaction mixtures with Cybr-Gold and visualisation by UV illumination. The use of a compatible buffer system for all enzymes allows the reaction to be initiated and detected in the same tube or microplate well, so that the experiment can be scaled up easily for high-throughput detection. Only a small amount of DNA (i.e. 50 ng) is required per assay, and use of carefully designed short padlock probes coupled with generic primers and probes make the SNP detection cost effective. Biallelic assay by hybridisation of the RCA products with fluorescence dye-labelled probes is demonstrated, indicating that ligation-RCA (L-RCA) has potential for multiplexed assays.  相似文献   

6.
Protein-protein interactions are pivotal to most, if not all, physiological processes, and understanding the nature of such interactions is a central step in biological research. Surface Plasmon Resonance (SPR) is a sensitive detection technique for label-free study of bio-molecular interactions in real time. In a typical SPR experiment, one component (usually a protein, termed ''ligand'') is immobilized onto a sensor chip surface, while the other (the ''analyte'') is free in solution and is injected over the surface. Association and dissociation of the analyte from the ligand are measured and plotted in real time on a graph called a sensogram, from which pre-equilibrium and equilibrium data is derived. Being label-free, consuming low amounts of material, and providing pre-equilibrium kinetic data, often makes SPR the method of choice when studying dynamics of protein interactions. However, one has to keep in mind that due to the method''s high sensitivity, the data obtained needs to be carefully analyzed, and supported by other biochemical methods. SPR is particularly suitable for studying membrane proteins since it consumes small amounts of purified material, and is compatible with lipids and detergents. This protocol describes an SPR experiment characterizing the kinetic properties of the interaction between a membrane protein (an ABC transporter) and a soluble protein (the transporter''s cognate substrate binding protein).  相似文献   

7.
Sensitive detection assays are a prerequisite for the analysis of small amounts of samples derived from biological material. There is a great demand for highly sensitive and robust detection techniques to analyze biomolecules. The combination of catalytic active DNA (DNAzyme) with a peroxidase activity with rolling circle amplification (RCA) is a promising alternative to common detection systems. The rolling circle amplification leads to a product with tandemly linked copies of DNAzymes. The continuous signal generation of the amplified DNAzymes results in an increased sensitivity. The combination of two amplification reactions, namely RCA and DNAzymes, results in increased signal intensity by a factor of 10(6). With this approach the labeling of samples can be avoided. The advantage of the introduced assay is the usage of nucleic acids as biosensors for the detection of biomolecules. Coupling of the analyte molecule to the detection molecules allows the direct detection of the analyte molecule. The described label-free hotpot assay has a broad potential field of applications. The hotpot assay can be adapted to detect and analyze RNA, DNA and proteins down to femtomolar concentrations in a miniaturized platform with a total reaction solution of 50 nl. The applicability of the assay for diagnostics and research will be shown with a focus on high throughput systems using a nano-well platform.  相似文献   

8.
We demonstrated a simple and efficient strategy, which based on the enzymatically biocatalytic precipitates amplified antibody-antigen interaction, for improving the response signals of surface plasmon resonance (SPR) immunosensing. The antibody-antigen-alkaline phosphatase (AP) labeled secondary antibody sandwich were successfully prepared and characterized by SPR, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The SPR signal amplification was accomplished through probing resonance angle shift and Faradaic electron impedance of [Fe(CN)(6)](3-/4-) redox pair after the enzymatically biocatalytic products precipitating on the immunosensing electrode surface. As a result, the accumulation of the enzymatically biocatalytic precipitates leads to significantly resonance angle shift and increase of electron transfer impedance of [Fe(CN)(6)](3-/4-) probe. The precipitates-enhanced sandwich SPR immunoassay for mouse immunoglobulin G (m-IgG) can easily detect solution protein concentrations in the linear range of 0.02-40 ng mL(-1) and with a detection limit of 200 fg mL(-1), which is more than four-orders and 10 times better compared with the values using streptavidin-biotinylated protein complex and biotinylated HRP biocatalyzation amplification methods. Moreover, this method is generally applicable to other sandwich immunoassays and also can be expanded to monitor other antibody-antigen interaction for immunosensing detection at low concentrations.  相似文献   

9.
The inability of surface plasmon resonance (SPR) spectroscopy to detect extremely small refractive index changes has hindered its applications in ultrasensitive DNA analysis. In this study we report a signal amplification strategy that uses DNA-templated polyaniline deposition, suitable for DNA hybridization analysis with charge neutral peptide nucleic acid (PNA) being probes. Under acidic conditions, protonated aniline monomers are adsorbed on DNA backbones through electrostatic interaction. The microenvironment provided by the DNA facilitates oxidative aniline polymerization initialized by H2O2 in the presence of horseradish peroxide. Under optimal conditions, the detection limit is lowered from 5 nM for conventional SPR detection to 0.1 pM. The significant sensitivity improvement is attributed to the in-situ polymer chain growth along DNA strands, which introduces drastic refractive index increases. This signal amplification approach does not involve secondary hybridization processes. The detection sensitivity obtained is much better than that of gold nanoparticle-based amplification involving a secondary hybridization process and labeled DNA detection probes.  相似文献   

10.
SPR biosensing coupled to a digital microfluidic microstreaming system   总被引:1,自引:0,他引:1  
This article reports on a proof-of-concept system composed of a droplet based surface plasmon resonance (SPR) system coupled to a surface acoustic wave (SAW) microfluidic plateform. It is now well established that surface based binding analyses such as SPR are highly influenced by the transport of analyte to the sensing surface. Further, obtaining reliable equilibrium in flow cells to realize quantification studies is not straightforward. An original solution compared to generally used pressure driven flows is then proposed to favourably cope with these issues. Efficiency of SAW microstreaming coupled to SPR biosensing is considered, in order to improve the accuracy of kinetic parameter estimation in mass transport limited regime and to realize reliable quantification studies. First, the droplet based SPR technique and its advantages are presented. Then, the integration of the microstreaming on the system is discussed. Streptavidin binding is then monitored in static mode and under SAW streaming mode.  相似文献   

11.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

12.
Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.  相似文献   

13.
A surface plasmon resonance (SPR)-immunosensor for detection of benzo[a]pyrene (BaP) is developed by using a model BaP-hapten compound, BaP-bovine serum albumin conjugate (BaP-BSA), and an anti-BaP-BSA monoclonal antibody. BaP-BSA conjugate is immobilized on a gold thin-film sensor chip by means of simple physical adsorption. The number of BaP-hapten units in BaP-BSA conjugate is estimated to be 28 from the difference in molecular weight (MW) between BaP-BSA conjugate and BSA based on the results of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) measurement. Anti-BaP-BSA antibody on contact with the BaP-BSA conjugate immobilized sensor chip causes an increase in the incident angle of the sensor chip. Binding of anti-BaP-BSA antibody with surface-immobilized BaP-BSA conjugate is inhibited by the presence of BaP in analyte solution, because of the inhibition effect of BaP. The SPR immunosensor for BaP functioning with the indirect competitive immunoreaction of anti-BaP-BSA antibody between the analyte (BaP) in testing solution and the BaP-BSA conjugate immobilized on the sensor chip provides a rapid determination (response time: ca. 15 min) of BaP in the concentration range of 0.01-1000 ppb. The antibody anchored to the sensor chip by antigen-antibody binding is removed on treatment with a pepsin solution (pH 2.0) for few minutes. The SPR sensor chip is found to be reusable for more than 20 times with a little decrease (<7%) in the sensor response. Detection of BaP by direct competitive immunoreactions is also carried out by enzyme-linked immunosorbent assay (ELISA). The concentration of BaP could be determined as low as 0.01 ppb and 2 ppb using the SPR sensor and the ELISA method, respectively. The SPR sensor is found to detect BaP selectively in the presence of 2-hydroxybiphenyl (HBP); the incident angle shift of the SPR sensor for BaP is found to be same irrespective to the presence or the absence of a same concentration (as much as 30 ppb) of HBP together.  相似文献   

14.
An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria.  相似文献   

15.
滚环DNA扩增的原理、应用和展望   总被引:2,自引:0,他引:2  
滚环DNA扩增 (rollingcircleDNAamplification ,RCA)是一种等温信号扩增方法 ,其线性扩增倍数为 1 0 5,指数化扩增能力大于 109,产生的扩增产物连接在固相支持物 (如玻片、微孔板等 )表面的DNA引物或抗体上。RCA是一种适合在芯片上 (on chip)进行信号扩增的新技术 ,它既能提供研究分析的敏感性和特异性 ,又能保持立体分析的多元性。RCA亦是一种痕量的分子检测方法 ,可用于极其微量的生物大分子和生物标志的检测与研究  相似文献   

16.
Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultaneous detection of multiple analytes (multi-analyte detection). In addition, we report application of a recently developed multichannel SPR sensor based on spectroscopy of surface plasmons and wavelength division multiplexing of sensing channels to multi-analyte detection.  相似文献   

17.
The goal of this work is to explore the amplification effect of aptamer–gold nanoparticles (Au NPs) conjugates for ultrasensitive detection of large biomolecules by surface plasmon resonance (SPR). A novel sandwich immunoassay is designed to demonstrate the amplification effect of aptamer–Au NPs conjugates by using human immunoglobulin E (IgE) as model analyte. Human IgE, captured by immobilized goat anti-human IgE on SPR gold film, is sensitively detected by SPR spectroscopy with a lowest detection limit of 1 ng/ml after anti-human IgE aptamer–Au NPs conjugates is used as amplification reagent. Meanwhile, the non-specific adsorption of aptamer–Au NPs conjugates on goat anti-human IgE is confirmed by SPR spectroscopy and then it is minimized by treating aptamer–Au NPs conjugates with 6-mercaptohexan-1-ol (MCH). These results confirm that aptamer–Au NPs conjugates is a powerful sandwich element and an excellent amplification reagent for SPR-based sandwich immunoassay.  相似文献   

18.

Background

State of the art molecular diagnostic tests are based on the sensitive detection and quantification of nucleic acids. However, currently established diagnostic tests are characterized by elaborate and expensive technical solutions hindering the development of simple, affordable and compact point-of-care molecular tests.

Methodology and Principal Findings

The described competitive reporter monitored amplification allows the simultaneous amplification and quantification of multiple nucleic acid targets by polymerase chain reaction. Target quantification is accomplished by real-time detection of amplified nucleic acids utilizing a capture probe array and specific reporter probes. The reporter probes are fluorescently labeled oligonucleotides that are complementary to the respective capture probes on the array and to the respective sites of the target nucleic acids in solution. Capture probes and amplified target compete for reporter probes. Increasing amplicon concentration leads to decreased fluorescence signal at the respective capture probe position on the array which is measured after each cycle of amplification. In order to observe reporter probe hybridization in real-time without any additional washing steps, we have developed a mechanical fluorescence background displacement technique.

Conclusions and Significance

The system presented in this paper enables simultaneous detection and quantification of multiple targets. Moreover, the presented fluorescence background displacement technique provides a generic solution for real time monitoring of binding events of fluorescently labelled ligands to surface immobilized probes. With the model assay for the detection of human immunodeficiency virus type 1 and 2 (HIV 1/2), we have been able to observe the amplification kinetics of five targets simultaneously and accommodate two additional hybridization controls with a simple instrument set-up. The ability to accommodate multiple controls and targets into a single assay and to perform the assay on simple and robust instrumentation is a prerequisite for the development of novel molecular point of care tests.  相似文献   

19.
Cholesterol oxidase (ChOx) has been covalently immobilized onto 1-fluoro-2-nitro-4-azidobenzene (FNAB) modified poly-(3-hexylthiophene) (P3HT) self-assembled monolayer (SAM) onto gold coated glass plates. These ChOx/FNAB/P3HT/Au bio-electrodes have been characterized using contact angle (CA) measurements, UV-vis spectroscopy, electrochemical impedance technique, cyclic voltammetric technique and atomic force microscopic (AFM) technique, respectively. The ChOx/FNAB/P3HT/Au bio-electrodes were utilized for the estimation of cholesterol concentration in standard solutions using surface plasmon resonance (SPR) technique. It is shown that this SPR biosensor has linearity from 50 to 500 mg/dl of cholesterol in solution with detection limit of 50 mg/dl, sensitivity of 1.0 4 m degrees /(mg dl), reusability of around 15 times and a shelf-life of about 10 weeks when stored at 4 degrees C.  相似文献   

20.
Surface plasmon resonance (SPR) has recently gained attention as a label-free method for the detection of biological molecules binding onto functionalised surfaces. It is one of the most sensitive detection method for monitor variations in the thickness and refractive index in ultra-thin films. Here, the adsorption processes of oligonucleotides onto gold substrates have been investigated in aqueous buffer solution using SPR imaging measurements. The hybridization of a thiol-modified, single stranded oligonucleotide anchored to a gold surface via thiol group, with its complementary sequence has been observed and characterised monitoring the hybridization process by SPR equipment. In situ investigation of smallest changes in SPR imaging measurements dynamically performed in liquid phase in the presence of DNA complementary probes was performed. Infrared spectroscopy and scanning electron microscopy characterisation of the functionalised gold surfaces of the biosensor were compared with the images obtained by SPR experimental apparatus.  相似文献   